Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid interactive efficient buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Optimal Energy Dispatch Controller for Fuel Cell-Integrated Multi-Zone Building

Stationary fuel cells provide potential opportunities for energy savings when integrated with buildings. Through smart dispatch of both electrical power and heat generated by the fuel cells and managing the building loads, the buildings can achieve more efficient operation. In this paper, we develop an optimal energy dispatch controller to operate a fuel cell-integrated building. The controller leverages the inherent thermal storage and the dispatchable fuel cell to reduce its operating cost and to allow the building to participate in grid services. The proposed controller is implemented on two types of commercial buildings, a large office building and a large hotel, and the effectiveness of the controller is demonstrated through simulations. The results also indicate that the potential saving varies significantly with different system parameters, including season, fuel prices, and equipment sizing, which provide helpful insights for building operators and other stake holders.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

URBANopt: An Open-Source Software Development Kit for Community and Urban District Energy Modeling: Preprint

Urban building modeling tools are developing rapidly; these tools use emerging simulation workflows for specific urban environmental design tasks, such as assessing the impacts of energy efficiency technologies at a district scale. However, with the emergence of new environmental design tasks, addressing all possible use cases and tasks is challenging and cannot be covered by a single tool. Urban-scale analysis at this level of complexity often requires linking multiple emerging tools, rather than using a single tool, to adequately evaluate a variety of possible fields in urban environmental design. To achieve this, flexible platforms are needed to support multiple input formats (e.g., geometric and non-geometric building properties), enabling the mapping of such inputs to underlying simulation engines. This paper provides an overview of the open-source URBANopt Software Development Kit (SDK) for modeling high-performance buildings and energy systems at a district scale. URBANopt's flexible SDK is composed of several modules that can be customized to integrate with other tools and generate new workflows to perform urban environmental design tasks, such as capturing interactions between individual buildings, district energy systems, distributed energy resources, and the electric distribution grid. We describe the functionality of the core SDK modules in URBANopt (called Core Gem, GeoJSON Gem, and Scenario Gem) and discuss the flexibility of these modules as a means of integration with a variety of tools. We also document and demonstrate technical details of writing and combining new modules to create customized workflows. Finally, we present a case study that uses the URBANopt SDK to model a hypothetical mixed-use urban project and simulate various scenarios to meet district energy performance goals.

buildings↗

Intelligent Buildings of the Future: Cyberaware, Deep Learning Powered, and Human Interacting

This study discuss, intelligent buildings are quickly becoming cohesive and integral entities of cyber-physical ecosystems. Modern buildings adapt to internal and external elements and thrive on ever increasing data sources such as ubiquitous smart devices and sensors while mimicking various approaches previously known in software, hardware, and bio inspired systems. This article provides an overview of intelligent buildings of the future from a range of perspectives. First, a brief overview of prospects of U.S. and world energy consumption, concepts of smart buildings as integral entities of smart grids is presented. This is followed by a discussion of the role of connectivity and interoperability as well as current issues and solutions in the areas of security, resilience, and humans in realm of intelligent buildings. The article dives into detail about the intelligence aspect of intelligent buildings of the future. The learning and predictive Artificial Intelligence (AI) techniques behind many of the concepts of intelligent buildings are reviewed, including the latest techniques such as deep learning. As a concrete application of AI in the realm of intelligent buildings, prediction of energy consumption/load/demand, which is a much researched application of AI in the realm of intelligent buildings, is elaborated. The discussion is focused on most recent advancements of AI based demand prediction and the overview consists of existing research and a case study conducted by the authors for deep learning based demand prediction. Then, the article discusses the role of humans in intelligent buildings. Different types of human-building interactions are identified. Further, the article presents how each type of human-building interaction can benefit the overall control of intelligent buildings. The section is concluded by elaborating a case study conducted by the authors to achieve effective and efficient human-building interaction. The article is concluded with compilation of future insights based on latest technological advancements in U.S. industry and government.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sustainable Campus with PEV and Microgrid

Market penetration of electric vehicles (EVs) is gaining momentum, as is the move towards increasingly distributed, clean and renewable electricity sources. EV charging shifts a significant portion of transportation energy use onto building electricity meters. Hence, integration strategies for energy-efficiency in buildings and transport sectors are of increasing importance. This paper focuses on a portion of that integration: the analysis of an optimal interaction of EVs with a building-serving transformer, and coupling it to a microgrid that includes PV, a fuel cell and a natural gas micro-turbine. The test-case is the Nanyang Technological University (NTU), Singapore campus. The system under study is the Laboratory of Clean Energy Research (LaCER) Lab that houses the award winning Microgrid Energy Management System (MG-EMS) project. The paper analyses three different case scenarios to estimate the number of EVs that can be supported by the building transformer serving LaCER. An approximation of the actual load data collected for the building into different time intervals is performed for a transformer loss of life (LOL) calculation. The additional EV loads that can be supported by the transformer with and without the microgrid are analyzed. The numbers of possible EVs that can be charged at any given time under the three scenarios are also determined. The possibility of using EV fleet at NTU campus to achieve demand response capability and intermittent PV output leveling through vehicle to grid (V2G) technology and building energy management systems is also explored.

Singh, Reshma↗

Numerical Simulations of A Conceptual MSR-EES Shoulder Recession

The present study demonstrates our in-house material response solver, Icarus's capability to simulate the ablative conditions, including pyrolysis effects due to the interaction between hypersonic boundary layers and the thermal protection system (TPS). A conceptual aeroshell shoulder design, which undergoes mission-relevant flow and material conditions, is selected for the demonstration purpose. LAURA, a structured flow solver, is used to solve flow around the shoulder at several trajectory points of a flight path. The aerothermal dataset obtained from LAURA is used to enforce boundary conditions on the aeroshell wall to simulate ablation processes. The two-layered material system is stacked with HEEET (TPS) and Aluminum (actual material). A set of base parameters, such as the angle of material orientation with respect to the flow direction, convective heat-transfer co-efficient, and aerothermal boundary conditions on the rear end of the HEEET material layer, is selected to conduct a base-case simulation. A small amount of recession was observed, indicating that the design should be fine to go through the selected flow and material conditions. Furthermore, the parameters mentioned above are individually altered and are observed to affect the shoulder design's recession compared to the base case. Verification of our Icarus setup was also carried out using a one-dimensional grid and FIAT, a one-dimensional material-response solver, to build credibility for our results. As the current work is an uncoupled fluid-material-response simulation, a local sharp mesh deformation in the recessed surface near the shoulder corner is observed.

Prakash Shrestha↗

Occupant-driven end use load models for demand response and flexibility service participation of residential grid-interactive buildings

As demand response becomes increasingly used as a tool to support improved grid flexibility, it is important to consider that there are many potential types of energy end uses that may be used to support such flexibility. Residential appliances, often accounting for 30 % or more of residential energy use, are a currently untapped source of demand flexibility, particularly when aggregated together across homes. To date there has been very limited analysis of residential appliances for use as grid-interactive loads. As such, this research uses disaggregated energy end use data for 564 households, to model the electricity demand flexibility potential of the use of residential dishwashers, clothes washers, clothes dryers, ovens, and ranges (oven + stovetop) on both weekdays and weekends. This includes both at the building level, as well as aggregated to the grid level, specifically the Midcontinent Independent System Operator (MISO) region. This study was divided into two parts. Part 1 focuses on determining appliance-level loads, and Part 2, which involves aggregation to the grid. Findings suggest that among the studied appliances, clothes dryers provide the greatest demand reduction potential for most times of the day, followed by dishwashers and clothes washers. The maximum potential reduction for clothes dryers is found to be approximately at 11:00 a.m. and this potential sustains throughout most of the daytime period. When considering the willingness of households to participate, based on a survey of households in the Midwest region, clothes dryers still have the most potential for demand reduction. The availability of appliances for load modulation on weekdays and weekends indicates similar load reduction potential for all appliances. Overall, the results of this study suggest that there is an opportunity for shifting appliance usage to optimize grid efficiency and enhance demand response strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential Energy Savings Due to Phase Change Material in a Building Wall Assembly: An Examination of Two Climates

Phase change material (PCM), placed in an exterior wall, alters the temperature profile within the wall and thus influences the heat transport through the wall. This may reduce the net energy transport through the wall via interactions with diurnal temperature swings in the external environment or reduce the electricity needed to meet the net load through the wall by shifting the time of the peak load to a time when the cooling system operates more efficiently. This study covers a broad range of parameters that can influence the effectiveness of such a merged thermal storage-thermal insulation system. These parameters included climate, PCM location within the wall, amount of PCM, midpoint of the PCM melting and freezing range relative to the indoor setpoint temperature, temperature range over which phase change occurs, and the wall orientation. Two climates are investigated using finite difference and optimization analyses: Phoenix and Baltimore, with two utility rate schedules. Although potential savings for a PCM with optimized properties were greater when the PCM was concentrated near the inside wall surface, other considerations described here lead to a recommendation for a full-thickness application. An examination of the temperature distribution within the walls also revealed the potential for this system to reduce the amount of energy transported through the wall framing. Finally, economic benefits can exceed energy savings when time-of-day utility rates are in effect, reflecting the value of peak load reductions for the utility grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CAPRI: Using a Geometric Foundation for Computational Analysis and Design

CAPRI (Computational Analysis Programming Interface) is a software development tool intended to make computerized design, simulation and analysis faster and more efficient. The computational steps traditionally taken for most engineering analysis (Computational Fluid Dynamics (CFD), structural analysis, etc.) are: Surface Generation, usually by employing a Computer Aided Design (CAD) system; Grid Generation, preparing the volume for the simulation; Flow Solver, producing the results at the specified operational point; Post-processing Visualization, interactively attempting to understand the results. It should be noted that the structures problem is more tractable than CFD; there are fewer mesh topologies used and the grids are not as fine (this problem space does not have the length scaling issues of fluids). For CFD, these steps have worked well in the past for simple steady-state simulations at the expense of much user interaction. The data was transmitted between phases via files. In most cases, the output from a CAD system could go IGES files. The output from Grid Generators and Solvers do not really have standards though there are a couple of file formats that can be used for a subset of the gridding (i.e. PLOT3D) data formats and the upcoming CGNS). The user would have to patch up the data or translate from one format to another to move to the next step. Sometimes this could take days. Instead of the serial approach to analysis, CAPRI takes a geometry centric approach. CAPRI is a software building tool-kit that refers to two ideas: (1) A simplified, object-oriented, hierarchical view of a solid part integrating both geometry and topology definitions, and (2) programming access to this part or assembly and any attached data. The connection to the geometry is made through an Application Programming Interface (API) and not a file system.

Haimes, Robert↗

Use of Phase Change Material in a Building Wall Assembly: A Case Study of Technical Potential in Two Climates

Phase change material (PCM), placed in an exterior wall, alters the temperature profile within the wall and thus influences the heat transport through the wall. This may reduce the net energy transport through the wall via interactions with diurnal temperature swings in the external environment or reduce the electricity needed to meet the net load through the wall by shifting the time of the peak load to a time when the cooling system operates more efficiently. This study covers a broad range of parameters that can influence the effectiveness of such a merged thermal storage-thermal insulation system. These parameters included climate, PCM location within the wall, amount of PCM, midpoint of the PCM melting and freezing range relative to the indoor setpoint temperature, temperature range over which phase change occurs, and the wall orientation. Two climates are investigated using finite difference and optimization analyses: Phoenix and Baltimore, with two utility rate schedules. Although potential savings for a PCM with optimized properties were greater when the PCM was concentrated near the inside wall surface, other considerations described here lead to a recommendation for a full-thickness application. An examination of the temperature distribution within the walls also revealed the potential for this system to reduce the amount of energy transported through the wall framing. Finally, economic benefits can exceed energy savings when time-of-day utility rates are in effect, reflecting the value of peak load reductions for the utility grid.

36 MATERIALS SCIENCE↗

Los Angeles Air Force Base Vehicle-to-Grid Demonstration (Final Project Report)

Electrification of non-tactical vehicle fleets represents a key efficiency and energy security objective for the United States Department of Defense. To achieve electrification, the department targeted vehicle-to-grid services as a way to decrease the overall cost of operating the vehicle fleet and achieve rough parity with traditional internal combustion engine vehicle fleets. This report describes efforts to aggregate a fleet of bi-directional electric vehicles and charging stations to provide regulation up and regulation down in the California Independent System Operator ancillary services market. A 29-vehicle electric vehicle demonstration fleet, consisting of mixed purpose and duty vehicles such as sedans, pickups, vans, and medium-duty trucks, was deployed at the Los Angeles Air Force base. The fleet provided frequency regulation to the California Independent System Operator’s wholesale electricity market to determine the capability of recouping some of the additional costs of procuring electric vehicles and their supporting infrastructure. Lawrence Berkeley National Laboratory, with its partner Kisensum, LLC, developed the fleet scheduling, optimization, and control software to allow the vehicle fleet at the air force base to participate in the ancillary services markets. This report focuses on the control software and market interactions, the significant challenges faced and solutions devised to address them, and examines the potential of using the electric vehicle fleet as an energy storage resource for the base buildings, an application known as vehicle-tobuilding, in providing demand response and emergency backup power. The report discusses key findings related to providing frequency regulation to the California Independent System Operator market, electric vehicle fleet performance, compatibility of varying resource parameters of vehicle fleet aggregation, the need for automated methods for communicating hour-ahead energy bidding, challenges related to battery capacity and charge/discharge rates, and monthly settlement revenue.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-driven modeling of dynamic occupant thermostat override behavior for demand response applications

Buildings consume nearly 40% of global energy and produce similar emissions. Whiletechnological advances address efficiency, occupant behavior causes energy use variations up to 300% between identical buildings. This gap between predicted and actual building performance impacts building design, operations, and grid demand management programs. Through analyses of smart thermostat data from 1,400 single-occupant homes, the researchdemonstrates that occupants respond to 8°F thermostat setpoint changes within a median of 15 minutes, while 2°F changes trigger responses within a median of 30 minutes. This highlights an understudied temporal relationship between thermostat setbacks and response time of occupant behaviors. Models of such behavior dynamics are required to incorporate occupant impacts into building performance simulation. A key contribution of this dissertation is the Thermal Frustration Theory (TFT), which positsthat thermal discomfort driven behaviors are caused by the time-accumulation of discomfort, not simply a temperature deviation threshold or a delay from an initiating event. Using a dataset of 634 thermostats, each with 25+ manual setpoint changes, a comparative analysis of TFT and comfort zone and a delayed response theories demonstrated that personalized TFT models better predict when manual setpoint change occur. This was measured by the area under the curve statistical measure (AUC); all three models perform similarly by a Matthews Correlation Coefficient measure. Higher AUC performance is especially important for modeling occupant behavior in demand response programs where false negatives of rare occupant interactions could adversely affect grid stability. EnergyPlus based simulations were conducted with TFT-derived occupant models, demonstrating the ability to identify parameters of known TFT models from only data observable with smart thermostats, even under the presence of noise from routine overrides. Overall, the dissertation highlights that thermostat interactions are neither static,instantaneous, nor driven solely by the environment. Instead, temporal accumulation of discomfort and routine-based behavior play important roles. The methodology and results offer a pathway towards more accurate modeling of human-building interactions for policy assessment, building design, and demand response programs.

Sharma, Kunind [Northeastern University] (ORCID:00↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Increasing the Number of Installed Residential Heat Pump Water Heaters in the USA Through Improved Technology and Utility Programs

Heat pump water heaters (HPWHs) offer an efficient alternative to electric resistance water heaters, but they suffer from limited market penetration. This paper reviews the current state of HPWHs in the USA, focusing on technology developments and programs to increase adoption. What technological improvements are needed to make HPWHs a good fit in more homes? Additionally, what are the best ways of promoting HPWHs to consumers? Improved communication and controls will allow HPWHs to provide demand response and follow dynamic utility rates. To enable fuel-switching, HPWHs are being developed that only need a standard 120V outlet. Split HPWHs can alleviate the cooling and noise that limit the use of HPWHs in small homes, multifamily buildings, and cold climates. Additionally, new utility programs aim to train installers and provide incentives to distributors to increase the number of HPWHs installed. Some utilities offer novel incentive programs that have led to increased customer uptake. Those advances, coupled with improved controls for load shifting and new products such as split HPWHs and HPWHs that can run on 120V power, may finally move the market forward.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Renewable Energy and Efficiency Technologies in Scenarios of U.S. Decarbonization in Two Types of Models: Comparison of GCAM Modeling and Sector-Specific Modeling

Energy system projections from analytic models inform actions ranging from short-term and local decisions, such as technology and infrastructure deployment, to global and long-term negotiations and targets. Computational limits require the designers of these models to trade off between coverage and resolution. Some models, such as the Global Change Analysis Model (GCAM), represent all energy sources and uses but at a relatively coarse level of resolution. GCAM balances global supply and demand of all energy carriers by endogenously projecting prices for energy sources and costs of greenhouse gas mitigation while capturing interlinkages between the energy system, water, agriculture and land use, the economy, and the climate. This global model was used to frame the Long-Term Strategy released by the White House in 2021 and has been used to inform national and global economy-wide decarbonization discussions and strategy development for decades. Other models instead focus on a portion of the energy sector with greater detail and resolution. The Regional Energy Deployment System (ReEDS) electricity-sector model, for example, projects capacity expansion with an emphasis on integration of variable renewable energy into the grid of the future. The Transportation Energy and Mobility Pathway Options (TEMPO) transportation-sector model enables analysis of household choices in adoption, charging, and use of electric vehicles. The Scout buildings-sector model supports detailed consideration of the policies and markets that can accelerate the adoption of energy conservation measures in buildings. Such sector-specific models are instrumental in informing technology research, sectoral planning strategies, and sector-specific aspects of greenhouse gas (GHG) mitigation strategies in the United States. These global and sector-specific modeling approaches can complement each other. The global approach ensures consistent, endogenous energy pricing and resource allocation, which can substantially diverge from current conditions in transformative scenarios, while the sector-specific approach facilitates representation of granular details across spatial, temporal, technological, and market dimensions that enable exploration of particular interactions and trade-offs. This report presents the results of recent work to explore the differences and tradeoffs between these approaches by comparing GCAM with the sector-specific ReEDS, TEMPO, and Scout models. The report compares both model structures and results, and discusses their potential relevance and applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Transactive Energy Network Template Metamodel

While transactive energy, which is defined as an allocation of electricity based on dynamically discovered values or prices, has been extensively studied, its uptake and use has been slow. This report describes a tool, the transactive network template, which should hasten the creation and uptake of transactive energy networks. Some basic principles of transactive energy are familiar from existing wholesale electricity markets. Locational prices are calculated today for zones within bulk electric transmission systems. Locational prices differ while accounting for the locational costs of electricity generation and the losses and constraints incurred when electricity is transmitted from generators and distributed to consumers. A transactive energy network might include these transmission zones. However, current research strives to apply transactive energy also in electricity distribution circuits, buildings, and even for individual generating and consuming devices. At the same time, researchers explore how to apply transactive energy in real time during increasingly shorter time intervals. Automated computational agents become necessary as transactive energy becomes applied to smaller circuit zones and at faster dynamic timescales. A transactive energy network is an example of a multi-agent system. Each zone in the network is represented by its transactive agent, which makes decisions for and acts on behalf of a business entity that is responsible for and manages one of the circuit regions. A transactive energy network is also an example of a decentralized, distributed control system. Control decisions and responsibilities are distributed among the network’s transactive agents. The transactive agents are independent; that is, there typically is no centralized authority or oversight function. Instead, transactive agents exchange transactive signals and thereby negotiate the prices and quantities of electricity that they will exchange. Initially, the circuit regions and responsibilities of transactive agents appear to be very dissimilar. Each circuit region may comprise transmission, distribution, or building-level circuits. Each has a unique position and electrical connectivity within the transactive energy network. Each possesses unique assets that either generate or consume electricity, and these (e.g., renewable energy generator, diesel generator, aggregate utility load, building load, space conditioning, refrigerator, etc.) may further differ in their price flexibility and in their strategies for responding to dynamic electricity prices. Given such diversity, an implementer’s first inclination might be to start from scratch to define all these devices and to engineer their seemingly unique interactions. Given that each implementer’s perspective may be narrow within a transactive energy network, it is unlikely that uniquely engineered systems would interact well. This is where the transactive network template is applicable. The transactive network template is a metamodel that has been developed to guide implementers as they configure their own transactive agent within a network of such agents. The object-oriented design of the transactive network template provides basic code object types that may be used and extended by implementers to represent each of the assets in their circuit region. These objects further facilitate the transactive agent’s necessary computations, which are divided among responsibilities to schedule power usage, balance electric supply and demand, and coordinate the exchange of electricity with the other transactive agents. This report addresses the conceptual transactive network template design. Implementers are directed to more formal design documents and reference implementations. A Python™-based1 reference implementation of the transactive network template has been coded, and three implementations have been configured to represent a national laboratory and two university campuses. Version 2 of the transactive node template generalizes the market class and its methods to facilitate multiple, and more diverse market coordination mechanisms than were facilitated by and demonstrated using Version 1. Version 3 includes new Appendix B, which addresses the designs of methods that would make dynamic prices track approved electricity rates. In the future, the author wishes to make the transactive network template more generally applicable to networks that require more accurate power flow. Development of the transactive network template is jointly funded by the U.S. Department of Energy (DOE) Energy Efficiency and Renewable Energy and the DOE Office of Electricity. In late 2015, one of the first projects to be funded by the DOE Grid Laboratory Modernization Laboratory Consortium was the Clean Energy and Transactive Campus project, led by Pacific Northwest National Laboratory. DOE funds were matched by an investment by the Washington Department of Commerce through its Clean Energy Fund. The transactive network template was developed to guide the implementation of transactive energy networks within this project’s scope.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis for the Addition of a Thermal Energy Storage System to a Central Plant

Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. Here, the results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗