Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Demonstration of large field effect in topological insulator films via a high-κ back gate

The spintronics applications long anticipated for topological insulators (TIs) has been hampered due to the presence of high density intrinsic defects in the bulk states. In this work we demonstrate the back-gating effect on TIs by integrating Bi{sub 2}Se{sub 3} films 6–10 quintuple layer (QL) thick with amorphous high-κ oxides of Al{sub 2}O{sub 3} and Y{sub 2}O{sub 3}. Large gating effect of tuning the Fermi level E{sub F} to very close to the band gap was observed, with an applied bias of an order of magnitude smaller than those of the SiO{sub 2} back gate, and the modulation of film resistance can reach as high as 1200%. The dependence of the gating effect on the TI film thickness was investigated, and ΔN{sub 2D}/ΔV{sub g} varies with TI film thickness as ∼t{sup −0.75}. To enhance the gating effect, a Y{sub 2}O{sub 3} layer thickness 4 nm was inserted into Al{sub 2}O{sub 3} gate stack to increase the total κ value to 13.2. A 1.4 times stronger gating effect is observed, and the increment of induced carrier numbers is in good agreement with additional charges accumulated in the higher κ oxides. Moreover, we have reduced the intrinsic carrier concentration in the TI film by doping Te to Bi{sub 2}Se{sub 3} to form Bi{sub 2}Te{sub x}Se{sub 1−x}. The observation of a mixed state of ambipolar field that both electrons and holes are present indicates that we have tuned the E{sub F} very close to the Dirac Point. These results have demonstrated that our capability of gating TIs with high-κ back gate to pave the way to spin devices of tunable E{sub F} for dissipationless spintronics based on well-established semiconductor technology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase gate of one qubit simultaneously controlling n qubits in a cavity

We propose how to realize a three-step controlled-phase gate of one qubit simultaneously controlling n qubits in a cavity or coupled to a resonator. The n two-qubit controlled-phase gates, forming this multiqubit phase gate, can be performed simultaneously. The operation time of this phase gate is independent of the number n of qubits. This phase gate controlling at once n qubits is insensitive to the initial state of the cavity mode and can be used to produce an analogous cnot gate simultaneously acting on n qubits. We present two alternative approaches to implement this gate. One approach is based on tuning the qubit frequency while in the other method the resonator frequency is tuned. Using superconducting qubits coupled to a resonator as an example, we show how to implement the proposed gate with one superconducting qubit simultaneously controlling n qubits selected from N qubits coupled to a resonator (1<n<N). We also give a discussion on realizing the proposed gate with atoms, by using one cavity initially in an arbitrary state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiqubit tunable phase gate of one qubit simultaneously controlling n qubits in a cavity

We propose how to realize a multiqubit tunable phase gate of one qubit simultaneously controlling n qubits with four-level quantum systems in a cavity or coupled to a resonator. Each of the n two-qubit controlled-phase (cp) gates involved in this multiqubit phase gate has a shared control qubit but a different target qubit. In this proposal, the two lowest levels of each system represent the two logical states of a qubit while the two higher-energy intermediate levels are used for the gate implementation. The method presented here operates essentially by creating a single photon through the control qubit, which then induces a phase shift to the state of each target qubit. The phase shifts on each target qubit can be adjusted by changing the Rabi frequencies of the pulses applied to the target qubit systems. The operation time for the gate implementation is independent of the number of qubits, and neither adjustment of the qubit level spacings nor adjustment of the cavity mode frequency during the gate operation is required by this proposal. It is also noted that this approach can be applied to implement certain types of significant multiqubit phase gates (e.g., the multiqubit phase gate consisting of n two-qubit cp gates which are key elements in quantum Fourier transforms). A possible physical implementation of our approach is presented. Our proposal is quite general and can be applied to physical systems such as various types of superconducting devices coupled to a resonator and trapped atoms in a cavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Benchmarking and Fidelity Response Theory of High-Fidelity Rydberg Entangling Gates

The fidelity of entangling operations is a key figure of merit in quantum information processing, especially in the context of quantum error correction. High-fidelity entangling gates in neutral atoms have seen remarkable advancement recently. A full understanding of error sources and their respective contributions to gate infidelity will enable the prediction of fundamental limits on quantum gates in neutral atom platforms with realistic experimental constraints. In this work, we implement the time-optimal Rydberg controlled-Z (CZ) gate, design a circuit to benchmark its fidelity, and achieve a fidelity, averaged over symmetric input states, of 0.9971 ( 5 ) , downward corrected for leakage error, which together with our recent work [Nature 634, 321–327 (2024)] forms a new state of the art for neutral atoms. The remaining infidelity is explained by an error model, consistent with our experimental results over a range of gate speeds, with varying contributions from different error sources. Further, we develop a fidelity response theory to efficiently predict infidelity from laser noise with nontrivial power spectral densities and derive scaling laws of infidelity with gate speed. Besides its capability of predicting gate fidelity, we also utilize the fidelity response theory to compare and optimize gate protocols, to learn laser frequency noise, and to study the noise response for quantum simulation tasks. Finally, we predict that a CZ gate fidelity of ≳ 0.999 is feasible with realistic experimental upgrades. Published by the American Physical Society 2025

Tsai, Richard Bing-Shiun (ORCID:0000000286758677)↗

Use of dMLC for implementation of dynamic respiratory-gated radiation therapy

Purpose: To simulate and evaluate the use of dynamic multileaf collimators (dMLC) in respiratory gating to compensate for baseline drift.Methods: Tumor motion tracking data from 30 lung tumors over 322 treatment fractions was analyzed with the finite state model. A dynamic respiratory gating window was established in real-time by determining the average positions during the previous two end-of-expiration breathing phases and centering the dMLC aperture on a weighted average of these positions. A simulated dMLC with physical motion constraints was used in dynamic gating treatment simulations. Fluence maps were created to provide a statistical description of radiation delivery for each fraction. Duty cycle was also calculated for each fraction.Results: The average duty cycle was 2.3% greater under dynamic gating conditions. Dynamic gating also showed higher fluences and less tumor obstruction. Additionally, dynamic gating required fewer beam toggles and each delivery period was longer on average than with static gating.Conclusions: The use of dynamic gating showed better performance than static gating and the physical constraints of a dMLC were shown to not be an impediment to dynamic gating.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-185: Gated CBCT Imaging for Positioning Moving Lung Tumor in Lung SBRT Treatment

Purpose: Lung stereo-tactic body radiotherapy(SBRT) treatment requires high accuracy of lung tumor positioning during treatment, which is usually accomplished by free breathing Cone-Beam computerized tomography (CBCT) scan. However, respiratory motion induced image artifacts in free breathing CBCT may degrade such positioning accuracy. The purpose of this study is to investigate the feasibility of gated CBCT imaging for lung SBRT treatment. Methods: Six Lung SBRT patients were selected for this study. The respiratory motion of the tumors ranged from 1.2cm to 3.5cm, and the gating windows for all patients were set between 35% and 65% of the respiratory phases. Each Lung SBRT patient underwent free-breathing CBCT scan using half-fan scan technique. The acquired projection images were transferred out for off-line analyses. An In-house semi-automatic algorithm was developed to trace the diaphragm movement from those projection images to acquire a patient's specific respiratory motion curve, which was used to correlate respiratory phases with each projection image. Afterwards, a filtered back-projection algorithm was utilized to reconstruct the gated CBCT images based on the projection images only within the gating window. Results: Target volumes determined by free breathing CBCT images were 71.9%±72% bigger than the volume shown in gated CBCT image. On the contrary, the target volume differences between gated CBCT and planning CT images at exhale stage were 5.8%±2.4%. The center to center distance of the targets shown in free breathing CBCT and gated CBCT images were 9.2±8.1mm. For one particular case, the superior boundary of the target was shifted 15mm between free breathing CBCT and gated CBCT. Conclusion: Gated CBCT imaging provides better representation of the moving lung tumor with less motion artifacts, and has the potential to improve the positioning accuracy in lung SBRT treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-346: Validation of Beam Accuracy of a Gated Spot-Scanning Proton Therapy System with Real-Time Tumor-Tracking at Hokkaido University

Purpose: At Hokkaido University, we have developed a gated spot scanning proton beam therapy system with real-time tumor-tracking under collaborative work with Hitachi Ltd. This system has the ability to gate proton beams from the synchrotron, turning the beam on only when the actual positions of inserted fiducial markers monitored by two fluoroscopic X-ray systems are within the planned positions [Shirato, 2012]. In this research, we validated the accuracy of the proton beams while utilizing external gating signals. Methods: The accuracy of spot positions, spot dose, absolute dose at the center of the SOBP, and range were measured while utilizing external gating signals. The following external gating signals were generated by an arbitrary waveform generator: (1) ON at all times (without gating), (2) an OFF period of 4 s followed by an ON period of 1 s, (3) two ON periods of 0.5 s with a 0.15 s OFF interval, (4) signals recorded during the treatment of real-time tumor-tracking X-ray therapy in Hokkaido University. The spot positions and spot dose were measured by beam monitors in the nozzle. The ranges were measured with a multi-layer ion chamber made by Hitachi Ltd. The absolute dose was measured with a Farmer ionization chamber and a RFA300 water phantom system. Results: The maximum error of the beam position in the isocenter plane was 0.8 mm without the gating signal and 1.0 mm with the gating signal. The maximum error of the spot dose was 0.0029 MU, below the criterion of 0.0032 MU. The maximum error of the absolute dose was 0.4% and the maximum variation of the range was 0.1 mm. Conclusion: It was confirmed with measurements of the beam that the accuracy of the proton beam met the criteria with external gating signals. This research was supported by the Cabinet Office, Government of Japan and the Japan Society for the Promotion of Science (JSPS) through the Funding Program for World-Leading Innovative R and D on Science and Technology (FIRST Program), initiated by the Council for Science and Technology Policy (CSTP)

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-J-01: TG142 Complied Comprehensive Commissioning and Quality Assurance Procedure for Respiratory Gating

Purpose: To develop and establish a comprehensive gating commissioning and quality assurance procedure in compliance with TG142. Methods: Quality assurance tests on three Varian LINACs included beam output and energy constancy, calibration of surrogate, as well as phase and amplitude gating temporal accuracy. A diode array (MapCHECK 2) and film (Gafchromic EBT2) were used to measure the temporal accuracy of phase and amplitude gating windows. A motion simulation device (MotionSim) was used to simulate respiratory motion for both detectors. An end-to-end test was also performed on all three machines. The overall accuracy and uncertainty was analyzed and compared. Results: The end-to-end test using an anthropomorphic lung phantom (CIRS) results in an OSL dose difference reading within 5% (within measurement uncertainty) for both phase and amplitude gated treatment. Film results showed < 1% agreement between profiles for gated delivery and predicted dose. The diode array demonstrated an 80% passing rate for gamma criteria of 2%/0.2 mm, which results in a 111 msec temporal accuracy. However, the diode array is limited by its spatial resolution of measurements, due to its 7.07 mm diode spacing. Film provided higher measuring resolution, thus demonstrated a temporal accuracy of <100 msec. Conclusion: Results showed consistent respiratory gating stability and accuracy. MapCHECK 2 may not be sufficient for the temporal accuracy test in the respiratory gating treatment in order to meet the corresponding tolerance in TG142. One would need to decrease respiratory motion speed from the surrogate or tighten the gating window in order to be within tolerance of 100 msec temporal accuracy per TG-142. The end-to-end test offers insight to the overall accuracy and uncertainties with a gated protocol. Compared to static delivery, respiratory motion increases the overall uncertainty of treatment delivery from 3% to 5% dose difference.

60 APPLIED LIFE SCIENCES↗

SU-E-T-266: Development of Evaluation System of Optimal Synchrotron Controlling Parameter for Spot Scanning Proton Therapy with Multiple Gate Irradiations in One Operation Cycle

Purpose: We have developed a gated spot scanning proton beam therapy system with real-time tumor-tracking. This system has the ability of multiple-gated irradiation in a single synchrotron operation cycle controlling the wait-time for consecutive gate signals during a flat-top phase so that the decrease in irradiation efficiency induced by irregular variation of gate signal is reduced. Our previous studies have shown that a 200 ms wait-time is appropriate to increase the average irradiation efficiency, but the optimal wait-time can vary patient by patient and day by day. In this research, we have developed an evaluation system of the optimal wait-time in each irradiation based on the log data of the real-time-image gated proton beam therapy (RGPT) system. Methods: The developed system consists of logger for operation of RGPT system and software for evaluation of optimal wait-time. The logger records timing of gate on/off, timing and the dose of delivered beam spots, beam energy and timing of X-ray irradiation. The evaluation software calculates irradiation time in the case of different wait-time by simulating the multiple-gated irradiation operation using several timing information. Actual data preserved in the log data are used for gate on and off time, spot irradiation time, and time moving to the next spot. Design values are used for the acceleration and deceleration times. We applied this system to a patient treated with the RGPT system. Results: The evaluation system found the optimal wait-time of 390 ms that reduced the irradiation time by about 10 %. The irradiation time with actual wait-time used in treatment was reproduced with accuracy of 0.2 ms. Conclusion: For spot scanning proton therapy system with multiple-gated irradiation in one synchrotron operation cycle, an evaluation system of the optimal wait-time in each irradiation based on log data has been developed. Funding Support: Japan Society for the Promotion of Science (JSPS) through the FIRST Program.

60 APPLIED LIFE SCIENCES↗

WE-EF-303-05: Development and Commissioning of Real-Time Imaging Function for Respiratory-Gated Spot-Scanning Proton Beam Therapy

Purpose: To realize real-time-image gated proton beam therapy (RGPT) for treating mobile tumors. Methods: The rotating gantry of spot scanning proton beam therapy has been designed to equip two x-ray fluoroscopy devices that enable real-time imaging of the internal fiducial markers during respiration. Three-dimensional position of the fiducial marker located near the tumor can be calculated from the fluoroscopic images obtained from orthogonal directions and therapeutic beam is gated only when the fiducial marker is within the predefined gating window. Image acquisition rate can be selected from discrete value ranging from 0.1 Hz to 30 Hz. In order to confirm the effectiveness of RGPT and apply it clinically, clinical commissioning was conducted. Commissioning tests were categorized to main three parts including geometric accuracy, temporal accuracy and dosimetric evaluation. Results: Developed real-time imaging function has been installed and its basic performances have been confirmed. In the evaluation of geometric accuracy, coincidence of three-dimensional treatment room coordinate system and imaging coordinate system was confirmed to be less than 1 mm. Fiducial markers (gold sphere and coil) were able to be tracked in simulated clinical condition using an anthropomorphic chest phantom. In the evaluation of temporal accuracy, latency from image acquisition to gate on/off signal was about 60 msec in typical case. In dosimetric evaluation, treatment beam characteristics including beam irradiation position and dose output were stable in gated irradiation. Homogeneity indices to the mobile target were 0.99 (static), 0.89 (w/o gating, motion is parallel to direction of scan), 0.75 (w/o gating, perpendicular), 0.98 (w/ gating, parallel) and 0.93 (w/ gating, perpendicular). Dose homogeneity to the mobile target can be maintained in RGPT. Conclusion: Real-time imaging function utilizing x-ray fluoroscopy has been developed and commissioned successfully in order to realize RGPT. Funding Support: This research was partially supported by Japan Society for the Promotion of Science (JSPS) through the FIRST Program. Conflict of Interest: Prof. Shirato has research fund from Hitachi Ltd, Mitsubishi Heavy Industries Ltd and Shimadzu Corporation.

60 APPLIED LIFE SCIENCES↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 06: Patient-specific QA Procedure for Gated VMAT SABR Treatments using 10x Beam in Flattening-Filter Free Mode

Purpose: To develop a highly sensitive patient specific QA procedure for gated VMAT stereotactic ablative radiotherapy (SABR) treatments. Methods: A platform was constructed to attach the translational stage of a Quasar respiratory motion phantom to a pinpoint ion chamber insert and move the ion chamber inside the ArcCheck. The Quasar phantom controller uses a patient-specific breathing pattern to translate the ion chamber in a superior-inferior direction inside the ArcCheck. With this system the ion chamber is used to QA the correct phase of the gated delivery and the ArcCheck diodes are used to QA the overall dose distribution. This novel approach requires a single plan delivery for a complete QA of a gated plan. The sensitivity of the gating QA procedure was investigated with respect to the following parameters: PTV size, exhale duration, baseline drift, gating window size. Results: The difference between the measured dose to a point in the penumbra and the Eclipse calculated dose was under 2% for small residual motions. The QA procedure was independent of PTV size and duration of exhale. Baseline drift and gating window size, however, significantly affected the penumbral dose measurement, with differences of up to 30% compared to Eclipse. Conclusion: This study described a highly sensitive QA procedure for gated VMAT SABR treatments. The QA outcome was dependent on the gating window size and baseline drift. Analysis of additional patient breathing patterns is currently undergoing to determine a clinically relevant gating window size and an appropriate tolerance level for this procedure.

60 APPLIED LIFE SCIENCES↗

Controlled gate networks: theory and application to eigenvalue estimation

We introduce a new scheme for quantum circuit design called controlled gate networks. Rather than trying to reduce the complexity of individual unitary operations, the new strategy is to toggle between all of the unitary operations needed with the fewest number of gates. We present the general theory of controlled gate networks and show that, under quite general conditions, it can significantly reduce the number of two-qubit gates needed to produce linear combinations of unitary operators. The first example we consider is a variational subspace calculation for a two-qubit system. The second example is estimating the eigenvalues of a two-qubit Hamiltonian via the rodeo algorithm (Choi et al. in Phys Rev Lett 127(4):040505, 2021. https://doi.org/10.1103/PhysRevLett.127.040505) using operators that we call controlled reversal gates. We use the Quantinuum H1-2 and IBM Perth devices to realize the quantum circuits. The third example is the application of controlled gate networks to the controlled time evolution of a free nucleon on a three-dimensional lattice. For all of the examples, we show very substantial reductions in the number of two-qubit gates required. Our work demonstrates that controlled gate networks are a useful tool for reducing gate complexity in quantum algorithms for quantum many-body problems such as those relevant to nuclear physics.

Bee-Lindgren, Max [Georgia Institute of Technology↗

Hardware-Conscious Optimization of the Quantum Toffoli Gate

While quantum computing holds great potential in combinatorial optimization, electronic structure calculation, and number theory, the current era of quantum computing is limited by noisy hardware. Many quantum compilation approaches can mitigate the effects of imperfect hardware by optimizing quantum circuits for objectives such as critical path length. Few approaches consider quantum circuits in terms of the set of vendor-calibrated operations (i.e., native gates) available on target hardware. This manuscript expands the analytical and numerical approaches for optimizing quantum circuits at this abstraction level. We present a procedure for combining the strengths of analytical native gate-level optimization with numerical optimization. Although we focus on optimizing Toffoli gates on the IBMQ native gate set, the methods presented are generalizable to any gate and superconducting qubit architecture. Our optimized Toffoli gate implementation demonstrates an 18% reduction in infidelity compared with the canonical implementation as benchmarked on IBM Jakarta with quantum process tomography. Assuming the inclusion of multi-qubit cross-resonance (MCR) gates in the IBMQ native gate set, we produce Toffoli implementations with only six multi-qubit gates, a 25% reduction from the canonical eight multi-qubit implementations for linearly connected qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kilovolt Tri-Gate GaN Junction HEMTs with High Thermal Stability

The lack of reports on the high-temperature performance of tri-gate GaN power HEMTs has raised serious concern on their competitiveness. This work demonstrates the first normally-off tri-gate GaN HEMT that can block kilovolts at 150 °C and zero gate bias. The key enabling device design is a new type of tri-gate, the junction tri-gate, which comprises p-n junction wrapping around AlGaN/GaN fins in the gate region. At 150 °C, the GaN tri-gate junction HEMT (Tri-JHEMT) retains strong gate control and stable threshold voltage, while the traditional tri-gate metal-insulator-semiconductor (MIS) HEMTs fabricated on the same wafer shows a large threshold voltage shift and inferior capabilities of voltage blocking. These results show the excellent thermal stability of GaN Tri-JHEMTs and their great potentials for power electronics applications.

Ma, Yunwei↗

A gating grid driver for time projection chambers

A simple but novel driver system has been developed to operate the wire gating grid of a Time Projection Chamber (TPC). This system connects the wires of the gating grid to its driver via low impedance transmission lines. When the gating grid is open, all wires have the same voltage allowing drift electrons, produced by the ionization of the detector gas molecules, to pass through to the anode wires. When the grid is closed, the wires have alternating higher and lower voltages causing the drift electrons to terminate at the more positive wires. Rapid opening of the gating grid with low pickup noise is achieved by quickly shorting the positive and negative wires to attain the average bias potential with N-type and P-type MOSFET switches. The circuit analysis and simulation software SPICE shows that the driver restores the gating grid voltage to 90% of the opening voltage in less than 0.20 µs, for small values of the termination resistors. When tested in the experimental environment of a time projection chamber larger termination resistors were chosen so that the driver opens the gating grid in 0.35 µs. In each case, opening time is basically characterized by the RC constant given by the resistance of the switches and terminating resistors and the capacitance of the gating grid and its transmission line. By adding a second pair of N-type and P-type MOSFET switches, the gating grid is closed by restoring 99% of the original charges to the wires within 3 µs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intelligent Gate Drive for Fast Switching and Crosstalk Suppression of SiC Devices

This study presents an intelligent gate drive for silicon carbide (SiC) devices to fully utilize their potential of high switching-speed capability in a phase-leg configuration. Based on the SiC device's intrinsic properties, a gate assist circuit consisting of two auxiliary transistors with two diodes is introduced to actively control gate voltages and gate loop impedances of both devices in a phase-leg configuration during different switching transients. Compared to conventional gate drives, the proposed circuit has the capability of accelerating the switching speed of the phase-leg power devices and suppressing the crosstalk to below device limits. Based on Wolfspeed 1200-V SiC MOSFETs, the test results demonstrate the effectiveness of this intelligent gate drive under varying operating conditions. More importantly, the proposed intelligent gate assist circuitry is embedded into a gate drive integrated circuit, offering a simple, compact, and reliable solution for end-users to maximize benefits of SiC devices in actual power electronics applications.

30 DIRECT ENERGY CONVERSION↗

Multiple modalities converge on a common gate to control K 2P channel function

Members of the K 2P potassium channel family regulate neuronal excitability and are implicated in pain, anaesthetic responses, thermosensation, neuroprotection, and mood. Unlike other potassium channels, K 2P s are gated by remarkably diverse stimuli that include chemical, thermal, and mechanical modalities. It has remained unclear whether the various gating inputs act through separate or common channel elements. Here, we show that protons, heat, and pressure affect activity of the prototypical, polymodal K 2P , K 2P 2.1 (KCNK2/TREK-1), at a common molecular gate that comprises elements of the pore-forming segments and the N-terminal end of the M4 transmembrane segment. We further demonstrate that the M4 gating element is conserved among K 2P s and is employed regardless of whether the gating stimuli are inhibitory or activating. Our results define a unique gating mechanism shared by K 2P family members and suggest that their diverse sensory properties are achieved by coupling different molecular sensors to a conserved core gating apparatus.

59 BASIC BIOLOGICAL SCIENCES↗

Entangling-gate error from coherently displaced motional modes of trapped ions

Entangling gates in trapped-ion quantum computers are most often applied to stationary ions with initial motional distributions that are thermal and close to the ground state, while those demonstrations that involve transport generally use sympathetic cooling to reinitialize the motional state prior to applying a gate. Future systems with more ions, however, will face greater nonthermal excitation due to increased amounts of ion transport and exacerbated by longer operational times and variations over the trap array. In addition, pregate sympathetic cooling may be limited due to time costs and laser access constraints. In this paper, we analyze the impact of such coherent motional excitation on entangling-gate error by performing simulations of Mølmer-Sørenson (MS) gates on a pair of trapped-ion qubits with both thermal and coherent excitation present in a shared motional mode at the start of the gate. Here, we quantify how a small amount of coherent displacement erodes gate performance in the presence of experimental noise, and we demonstrate that adjusting the relative phase between the initial coherent displacement and the displacement induced by the gate or using Walsh modulation can suppress this error. We then use experimental data from transported ions to analyze the impact of coherent displacement on MS-gate error under realistic conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗