Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “freezing level”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Controlled freezing of biological samples

Apparatus consists of thermocouple connected to semiconductor reference junction. Junction is connected to amplifier that boosts signal by 1,000. High-level signal is displayed on recorder and fed into second amplifier where it is compared with signal from potentiometer of programmed dc reference in bag-temperature programer. Difference in signals indicates output voltage. Remaining circuitry provides zero-phase, time-proportion control of heaters such that heater power is directly proportional to error signal.

Cygnarowicz, T. A.↗

Water Phase Change Heat Exchanger System Level Analysis for Low Lunar Orbit

In low Lunar orbit (LLO) the thermal environment is cyclic - extremely cold in the eclipse and as warm as room temperature near the subsolar point. Phase change material heat exchangers (PCHXs) are the best option for long term missions in these environments. The Orion spacecraft will use a n-pentadecane wax PCHX for its envisioned mission to LLO. Using water as a PCM material is attractive because its higher heat of fusion and greater density result in a lighter, more compact PCHX. To assess the use of a water PCHX for a human spacecraft in a circular LLO, a system level analysis was performed for the Orion spacecraft. Three cases were evaluated: 1) A one-to-one replacement of the wax PCHX on the internal thermal control loop with a water PCHX (including the appropriate control modifications), 2) reducing the radiator return setpoint temperature below Orion's value to enhance PCHX freezing, and 3) placing the water PCM on the external loop. The model showed that the water PCHX could not be used as a drop-in replacement for the wax PCHX. It did not freeze fully during the eclipse owing to its low freezing point. To obtain equivalent performance, 40% more radiator area than the Orion baseline was required. The study shows that, although water PCHXs are attractive at a component level, system level effects mean that they are not the best choice for LLO.

Navarro, Moses↗

Structure and Origins of Trends in Hydrological Measures over the western United States

This study examines, at 1/8 degree spatial resolution, the geographic structure of observed trends in key hydrologically relevant variables across the western United States (U.S.) over the period 1950-1999, and investigates whether these trends are statistically significantly different from trends associated with natural climate variations. A number of variables were analyzed, including late winter and spring temperature, winter-total snowy days as a fraction of winter-total wet days, 1st April Snow Water Equivalent (SWE) as a fraction of October through March precipitation total (P{sub ONDJFM}), and seasonal (January-February-March; JFM) accumulated runoff as a fraction of water year accumulated runoff. The observed changes were compared to natural internal climate variability simulated by an 850-year control run of the CCSM3-FV climate model, statistically downscaled to a 1/8 degree grid using the method of Constructed Analogues. Both observed and downscaled temperature and precipitation data were then used to drive the Variable Infiltration Capacity (VIC) hydrological model to obtain the hydrological variables analyzed in this study. Large trends (magnitudes found less than 5% of the time in the long control run) are common in the observations, and occupy substantial part of the area (37-42%) over the mountainous western U.S. These trends are strongly related to the large scale warming that appears over 89% of the domain. The strongest changes in the hydrologic variables, unlikely to be associated with natural variability alone, have occurred at medium elevations (750 m to 2500 m for JFM runoff fractions and 500 m-3000 m for SWE/PONDJFM) where warming has pushed temperatures from slightly below to slightly above freezing. Further analysis using the data on selected catchments across the simulation domain indicated that hydroclimatic variables must have changed significantly (at 95% confidence level) over at least 45% of the total catchment area to achieve a detectable trend in measures accumulated to the catchment scale.

54 ENVIRONMENTAL SCIENCES↗

A Daily Surface Melt Product From Passive Microwave Swath Observations for Arctic Sea Ice Studies

Most passive microwave sea ice data products are produced with daily gridded brightness temperatures. However, a single polar-orbiting passive microwave instrument makes many measurements per day where swaths overlap in the polar regions. These level 1 swath brightness temperature observations can be used to derive information on sub-daily sea ice processes. One such process is the rapid transition of snow and ice between freezing and melting due to diurnal freeze-thaw cycling or brief warming events in the pre-melt season. Here, a new method utilizing the sub-daily variability in swath-to-swath observations is used to produce daily, binary maps of the melting status on Arctic Sea ice using Level 1C brightness temperatures from the Special Sensor Microwave Imager and Sounder (SSM/I-SSMIS) data record. The resulting data set will enable investigations of the frequency, inter-annual variability, and spatial extent of brief surface melting events occurring in the winter and shoulder seasons outside of the traditional summer melt season.

Angela C. Bliss↗

Simulating a Mesoscale Convective System Using WRF with a New Spectral Bin Microphysics: Part 1: Hail vs Graupel

A modified Fast Spectral Bin Microphysics scheme (FSBM-2) embedded into the Weather Research and Forecasting Model (WRF) is used to simulate a mesoscale deep convective system observed during the Midlatitude Continental Convective Clouds Experiment (MC3E). FSBM-2 uses modified source codes as compared to the current FSBM (FSBM-1). In contrast to FSBM-1, FSBM-2 can simulate hail of several cm in diameter and includes additional processes such as spontaneous breakup of raindrops and aerosol regeneration by drop evaporation. It is shown that allowing large hail particles of diameters exceeding about 1 cm substantially increases the agreement between the simulated and observed squall-line structures both in the convective and stratiform regions. In contrast, if graupel particles are used to represent high-density hydrometeors in convective areas, the ratio of convective-to-stratiform areas diverges from the ratio seen in observations and maximum radar reflectivities are substantially underestimated. Analysis of snow size distributions in the stratiform area shows an important link between the ice crystals formed by homogeneous freezing in the convective area to ice particle number concentration in the stratiform region. Simulated raindrop size distributions in the stratiform area below the melting level from FSBM-2 show a good agreement with observations. The regeneration of CCN by droplet evaporation and detrainment of these CCN to the stratiform region increases the concentration of CCN there up to 8-9 km altitude; the additional CCN penetrate clouds and produce new droplets, leading to some convection intensification. Key words: Mesoscale convective systems (MCS), squall lines, spectral bin microphysics, large hail, in-cloud nucleation, size distributions of hydrometeors in MCS.

Shpund, Kobby↗

Comparing Satellite- and Ground-Based Observations of Cloud Occurrence Over High Southern Latitudes

The 2B-CLDCLASS-LIDAR R05 (2BCL5) and the raDAR/liDAR (DARDAR) satellite retrievals of cloud occurrence are compared as a function of altitude and latitude. The largest disparities are observed at low altitudes over high southern latitudes. These data sets are cross referenced to ground-based measurements from the Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment (AWARE) campaign at McMurdo Station, Antarctica. Compared with AWARE observations, both 2BCL5 and DARDAR underestimate cloud occurrence below 1.5 km, with 2BCL5 and DARDAR distinguishing roughly one third of cloud occurrences observed by AWARE at 0.5 km. While DARDAR identifies greater cloud occurrences than 2BCL5 below 1.5 km, cloud occurrence values for the two data sets have similar differences relative to ground-based measurements. Therefore, the DARDAR retrievals of greater cloud occurrence at low altitudes are likely due to a larger quantity of false positives associated with radar ground clutter or attenuated lidar retrievals. DARDAR cloud occurrences match better with AWARE than 2BCL5 above 5 km. However, the likely underestimation of ground-based measurements at higher altitudes suggests DARDAR may underestimate high level cloud occurrence. Finally, both data sets indicate the presence of liquid containing clouds at temperatures within the homogeneous freezing regime, despite the fact that the ECMWF-AUX data set implemented in their processing clearly indicates temperatures below -38°C. Finally, using AWARE radiosonde (ECMWF-AUX) temperature data, we find that 2BCL5 detects 13.3% (13.8%) of mixed phase clouds below -38°C, while DARDAR detects 5.7% (6.6%) of mixed phase and 1.1% (1.3%) of liquid phase clouds below -38°C.

54 ENVIRONMENTAL SCIENCES↗

The physical squeezed limit: consistency relations at order q{sup 2}

In single-field models of inflation the effect of a long mode with momentum q reduces to a diffeomorphism at zeroth and first order in q. This gives the well-known consistency relations for the n-point functions. At order q{sup 2} the long mode has a physical effect on the short ones, since it induces curvature, and we expect that this effect is the same as being in a curved FRW universe. In this paper we verify this intuition in various examples of the three-point function, whose behaviour at order q{sup 2} can be written in terms of the power spectrum in a curved universe. This gives a simple alternative understanding of the level of non-Gaussianity in single-field models. Non-Gaussianity is always parametrically enhanced when modes freeze at a physical scale k{sub ph, f} shorter than H: f{sub NL} ∼ (k{sub ph, f}/H){sup 2}.

79 ASTRONOMY AND ASTROPHYSICS↗

Space Shuttle Propulsion Finishing Strong

Numerous lessons have been documented from the Space Shuttle Propulsion elements. Major events include loss of the SRB's on STS-4 and shutdown of an SSME during ascent on STS- 51F. On STS-112 only half the pyrotechnics fired to release the vehicle from the launch pad, a testament for redundancy. STS-91 exhibited freezing of a main combustion chamber pressure measurement and on STS-93 nozzle tube ruptures necessitated a low liquid level oxygen cut off of the main engines. A number of on pad aborts were experienced during the early program resulting in delays. And the two accidents, STS-51L and STS-107, had unique heritage in history from early Program decisions and vehicle configuration. Following STS-51L significant resources were invested in developing fundamental physical understanding of solid rocket motor environments and material system behavior. Human rating of solid rocket motors was truly achieved. And following STS-107, the risk of ascent debris was better characterized and controlled. Situational awareness during all mission phases improved, and the management team instituted effective risk assessment practices. These major events and lessons for the future are discussed. The last 22 flights of the Space Shuttle, following the Columbia accident, were characterized by remarkable improvement in safety and reliability. Numerous problems were solved in addition to reduction of the ascent debris hazard. The propulsion system elements evolved to high reliability and heavy lift capability. The Shuttle system, though not a operable as envisioned in the 1970's, successfully assembled the International Space Station (ISS) and provided significant logistics and down mass for ISS operations. By the end of the Program, the remarkable Space Shuttle Propulsion system achieved very high performance, was largely reusable, exhibited high reliability, and is a heavy lift earth to orbit propulsion system. The story of this amazing system is discussed in detail in the paper.

Owen, James W.↗

Shuttle Propulsion System Major Events and the Final 22 Flights

Numerous lessons have been documented from the Space Shuttle Propulsion elements. Major events include loss of the Solid Rocket Boosters (SRB's) on STS-4 and shutdown of a Space Shuttle Main Engine (SSME) during ascent on STS-51F. On STS-112 only half the pyrotechnics fired during release of the vehicle from the launch pad, a testament for redundancy. STS-91 exhibited freezing of a main combustion chamber pressure measurement and on STS-93 nozzle tube ruptures necessitated a low liquid level oxygen cut off of the main engines. A number of on pad aborts were experienced during the early program resulting in delays. And the two accidents, STS-51L and STS-107, had unique heritage in history from early program decisions and vehicle configuration. Following STS-51L significant resources were invested in developing fundamental physical understanding of solid rocket motor environments and material system behavior. And following STS-107, the risk of ascent debris was better characterized and controlled. Situational awareness during all mission phases improved, and the management team instituted effective risk assessment practices. The last 22 flights of the Space Shuttle, following the Columbia accident, were characterized by remarkable improvement in safety and reliability. Numerous problems were solved in addition to reduction of the ascent debris hazard. The Shuttle system, though not as operable as envisioned in the 1970's, successfully assembled the International Space Station (ISS). By the end of the program, the remarkable Space Shuttle Propulsion system achieved very high performance, was largely reusable, exhibited high reliability, and was a heavy lift earth to orbit propulsion system. During the program a number of project management and engineering processes were implemented and improved. Technical performance, schedule accountability, cost control, and risk management were effectively managed and implemented. Award fee contracting was implemented to provide performance incentives. The Certification of Flight Readiness and Mission Management processes became very effective. A key to the success of the propulsion element projects was related to relationships between the MSFC project office and support organizations with their counterpart contractor organizations. The teams worked diligently to understand and satisfy requirements and achieve mission success.

Owen, James W.↗

Characteristics and Origins of Frontal Convection During IMPACTS on 25 January 2020

This presentation will discuss the characteristics of frontal convection and its estimation from the ER-2 multifrequency nadir reflectivity and Doppler velocity from a warm-occlusion frontal system that traversed across the Northeast U.S. on 25 January 2020. This system that occurred during the IMPACTS field deployment, brought widespread clouds and precipitation to the Northeast. The system brought primarily rain in most areas of more intense rainfall associated with embedded convection near the frontal band and some freezing rain and/or snowfall in the northern regions or higher terrain due to the pre-existing low-level cold air. The NASA ER-2 instrumented with multifrequency radar and the NASA P-3 with in situ microphysics measurements both collected data from this system. The focus of this presentation is on the estimation of vertical velocity in convective and non-convective regions using the ER-2 nadir Doppler measurements. Vertical velocities are inherently difficult to estimate in frontal systems at mesoscale and below other than from direct in situ measurement because of their small magnitudes and errors in the measurements. Estimates from nadir Doppler measurements such as from the ER-2 are challenging because of both Doppler velocity uncertainties and the need to estimate particle fallspeed since the Doppler measurement is the vertical velocity plus the hydrometeor fallspeed. In the presentation, the vertical velocity estimation, its associated errors, and a possible mitigation scheme are described. The characteristics of the convective and stratiform regions on 25 January 2020 are discussed. The vertical velocity estimated from the nadir Doppler measurements are compared with P-3 in situ measurements. Estimation of vertical velocity is one of the goals for upcoming spaceborne missions such as EarthCare and ACCP.

Gerald M. Heymsfield↗

Thermally Conductive Backsheets (TCB) for Reduced Operating Temperatures

The performance of photovoltaic (PV) modules is primarily influenced by the plane of array (POA) irradiance and their operating temperature. The lower the module operating temperature, the higher is its performance. Increasing a module’s operating temperature reduces its power output due to an increase in the semiconductor’s intrinsic carrier density, leading to a reduction in the open-circuit voltage and, subsequently, reducing the maximum power point voltage. Reducing the operating temperature lowers the levelized cost of energy (LCOE) via increased energy production (i.e., more kilowatt hour over the life of the asset) and increased service lifetime (years in the field). The module operating temperature is dictated by the weather parameters and the thermal properties of module construction materials. The primary weather parameters influencing the PV module temperature are: the ambient temperature (directly related), irradiance (directly related), and wind speed (inversely related). The primary thermal properties of module construction materials influencing the PV module temperature are: the optical transmissivity and thermal conductivity of superstrate, the thermal conductivity of substrate, the thermal conductivity of encapsulant and the efficiency of the encapsulated solar cells. The primary goal of this study is to reduce the operating temperature of PV modules using thermally conductive backsheet (TCB) substrates developed by the industry. The temperature of PV modules installed in a large multi-MW plant can also be influenced by their physical locations in the plants due to the influence of wind direction. A thermal mapping of PV plants has also been investigated and presented in this study. The most commonly used PV backsheet material has been polyvinyl fluoride (DuPont trade name “Tedlar”)-based backsheet, which typically has three layers: Tedlar–polyethylene terephthalate (PET)–Tedlar (TPT). The primary goal of this project is to reduce the module operating temperature below the benchmark TPT backsheet temperature using newly developed TCBs by the industry. The overall approach of this project involves six focus areas: i) select and procure one TPT and thirteen promising TCBs available in the industry; ii) construct a large number of 1-cell and 9-cell modules using benchmark TPT and selected TCBs [all other construction materials are fixed and they are: glass superstrate, EVA encapsulant, mono-Si cell and junction box]; iii) to identify best performing TCBs, monitor the long-term field operating temperatures of the constructed modules which are installed in three climatic conditions (hot-low wind [Mesa, AZ], hot-high wind [Maricopa County, AZ] and temperate [Cumberland County, NC]; iv) to identify the most durable TCB, perform extended accelerated reliability testing of modules constructed with best three TCBs and benchmark TPT; v) to predict module temperature, develop physical and empirical thermal models with and without thermal properties of all construction materials in the modules, respectively; and vi) to determine the influence of wind speed and direction on the module operating temperature in a plant, and perform thermal mapping of PV modules in two large PV plants [Maricopa County, AZ and Cumberland County, NC]. The key achievements of this project are listed below: Backsheet selection: 14 backsheets were procured after an extensive literature and industry search. Finally, based on the thermal and other selection criteria, 1 TPT and 4 thermally conductive backsheets were selected for this project. Fabrication of mini modules: 50 one-cell modules were fabricated in year 1 for thermal performance evaluation. The module design was changed to nine-cell module at start of year 2 to mimic commercial design. 20 nine-cell modules were fabricated in year 2 for thermal performance evaluation. 28 four-cell modules were fabricated in year 3 for accelerated stress-testing. Thermal conductivity of backsheets: Year 1 TCBs showed at least 8% higher thermal conductivities than TPT. Year 2 and 3 TCBs showed at least 20% higher thermal conductivities than TPT. Installation of mini PV modules at three sites: 6 one-cell modules and 8 nine-cell modules were installed at AZ-1 site [Mesa, AZ]. 12 one-cell modules and 6 nine-cell modules were installed at each of two powerplants (AZ-2 [Maricopa County, AZ] and NC sites). Nominal operating cell temperatures (NOCT) of mini PV modules: NOCT of TCBs were observed to be lower than TPT with differences as high as 2°C. Comparison of thermal performance: The median operating temperature of one-cell modules was found to be reduced by 2°C by using TCB_A modules compared to TPT modules on several days in a month for few months in a year. The median temperature improvement of 4oC was achieved at several instances on a few days, but not all days, in a year using multiple TCBs compared to TPT. The final project milestone of achieving median temperature improvement of 5oC was achieved at several instances on a few days, but not all days, in a year using TCB_A compared to TPT. Empirical thermal model (without the need of construction material properties): Empirical thermal model for one-cell module was developed based on the input data of irradiance, wind speed and ambient temperatures. The primary input data differentiator for temperature differences between TPT and TCBs appears to be the irradiance level (solar gain). Accelerated durability testing: 20 four-cell modules using 4 backsheets (1 TPT and 3 TCBs) were exposed to Damp Heat 1000 hours (8 modules), UV/Thermal cycling (50 cycles)/Humidity freeze (10 cycles) test sequence (8 modules) and UV Weathering for qualification (8 modules). All the modules with four selected backsheets passed the stress tests per the retest guidelines of IEC 61215 standard for the backsheet change. Simplified comparative LCOE analysis: Using backsheet-specific power degradation levels in the accelerated tests (for TCB_A and TPT only), efficiency, service lifetime and assuming same cost for all backsheets, the LCOE of modules using TCB_A is determined to be lower than TPT. Due to lower operating temperature of TCB_A-based modules compared to TPT-based modules, the operating efficiency and service life of TCB_A-based modules are calculated to be higher than TPT-based modules. Temperature mapping of PV power plants: A distinct temperature difference (as high as 4°C) has been observed between the modules located in various parts of a single PV plant.

14 SOLAR ENERGY↗

Identification and Characterization of Five Cold Stress-Related Rhododendron Dehydrin Genes: Spotlight on a FSK-Type Dehydrin With Multiple F-Segments

Dehydrins are a family of plant proteins that accumulate in response to dehydration stresses, such as low temperature, drought, high salinity, or during seed maturation. We have previously constructed cDNA libraries from Rhododendron catawbiense leaves of naturally non-acclimated (NA; leaf LT 50 , temperature that results in 50% injury of maximum, approximately -7 degrees C) and cold-acclimated (CA; leaf LT 50 approximately -50 degrees C) plants and analyzed expressed sequence tags (ESTs). Five ESTs were identified as dehydrin genes. Their full-length cDNA sequences were obtained and designated as RcDhn 1-5. To explore their functionality vis-a-vis winter hardiness, their seasonal expression kinetics was studied at two levels. Firstly, in leaves of R. catawbiense collected from the NA, CA, and de-acclimated (DA) plants corresponding to summer, winter and spring, respectively. Secondly, in leaves collected monthly from August through February, which progressively increased freezing tolerance from summer through mid-winter. The expression pattern data indicated that RcDhn 1-5 had 6- to 15-fold up-regulation during the cold acclimation process, followed by substantial down-regulation during deacclimation (even back to NA levels for some). Interestingly, our data shows RcDhn 5 contains a histidine-rich motif near N-terminus, a characteristic of metal-binding dehydrins. Equally important, RcDhn 2 contains a consensus 18 amino acid sequence (i.e., ETKDRGLFDFLGKKEEEE) near the N-terminus, with two additional copies upstream, and it is the most acidic (pI of 4.8) among the five RcDhns found. The core of this consensus 18 amino acid sequence is a 11-residue amino acid sequence (DRGLFDFLGKK), recently designated in the literature as the F-segment (based on the pair of hydrophobic F residues it contains). Furthermore, the 208 orthologs of F-segment-containing RcDhn 2 were identified across a broad range of species in GenBank database. This study expands our knowledge about the types of F-segment from the literature-reported single F-segment dehydrins (FSKn) to two or three F-segment dehydrins: Camelina sativa dehydrin ERD14 as F 2 S 2 K n type; and RcDhn 2 as F 3 SK n type identified here. Our results also indicate some consensus amino acid sequences flanking the core F-segment in dehydrins. Implications for these cold-responsive RcDhn genes in future genetic engineering efforts to improve plant cold hardiness are discussed.

09 BIOMASS FUELS↗

Stream ecosystem responses to the 2007 spring freeze in the Southeastern United States: unexpected effects of climate change

Some expected changes in climate resulting from human greenhouse gas emissions are clear and well documented, but others may be harder to predict because they involve extreme weather events or heretofore unusual combinations of weather patterns. One recent example of unusual weather that may become more frequent with climate change occurred in early spring 2007 when a large Arctic air mass moved into the eastern United States following a very warm late winter. In this paper, we document effects of this freeze event on Walker Branch, a well-studied stream ecosystem in eastern Tennessee. The 2007 spring freeze killed newly grown leaf tissues in the forest canopy, dramatically increasing the amount of light reaching the stream. Light levels at the stream surface were sustained at levels considerably above those normal for the late spring and summer months due to the incomplete recovery of canopy leaf area. Increased light levels caused a cascade of ecological effects in the stream beginning with considerably higher (two-three times) rates of gross primary production (GPP) during the late spring and summer months when normally low light levels severely limit stream GPP. Higher rates of stream GPP in turn resulted in higher rates of nitrate (NO3-) uptake by the autotrophic community and lower NO3- concentrations in stream water. Higher rates of stream GPP in summer also resulted in higher growth rates of a dominant herbivore, the snail Elimia clavaeformis. Typically, during summer months net NO3- uptake and snail growth rates are zero to negative; however, in 2007 uptake and growth were maintained at moderate levels. These results show how changes in forest vegetation phenology can have dramatic effects on stream productivity at multiple trophic levels and on nutrient cycling as a result of tight coupling of forest and stream ecosystems. Thus, climate change-induced changes in canopy structure and phenology may lead to large effects on stream ecosystems in the future.

54 ENVIRONMENTAL SCIENCES↗

Irrigation scheduling, freeze warning and soil salinity detecting

The author has identified the following significant results. Correlations of multispectral scanner (MSS) digital data differences between vegetated and bare soil areas with salinity levels from the eight saline areas using MSS bands seven and ten in the infrared region were significant. Correlations were derived for Cameron County, Texas. Detection of saline soils may be possible, using either film density readings or multispectral scanner data, when the lower reflectance of vegetation on highly saline soil and the higher reflectance of vegetation on lower saline soil are considered by using film on MSS contrasts between vegetation and bare soil.

Wiegand, C. L.↗

The Safe Removal of Frozen Air from the Annulus of an LH2 Storage Tank

Large Liquid Hydrogen (LH2) storage tanks are vital infrastructure for NASA. Eventually, air may leak into the evacuated and perlite filled annular region of these tanks. Although the vacuum level is monitored in this region, the extremely cold temperature causes all but the helium and neon constituents of air to freeze. A small, often unnoticeable pressure rise is the result. As the leak persists, the quantity of frozen air increases, as does the thermal conductivity of the insulation system. Consequently, a notable increase in commodity boil-off is often the first indicator of an air leak. Severe damage can result from normal draining of the tank. The warming air will sublimate which will cause a pressure rise in the annulus. When the pressure increases above the triple point, the frozen air will begin to melt and migrate downward. Collection of liquid air on the carbon steel outer shell may chill it below its ductility range, resulting in fracture. In order to avoid a structural failure, as described above, a method for the safe removal of frozen air is needed. A thermal model of the storage tank has been created using SINDA/FLUINT modeling software. Experimental work is progressing in an attempt to characterize the thermal conductivity of a perlite/frozen nitrogen mixture. A statistical mechanics model is being developed in parallel for comparison to experimental work. The thermal model will be updated using the experimental/statistical mechanical data, and used to simulate potential removal scenarios. This paper will address methodologies and analysis techniques for evaluation of two proposed air removal methods.

cryogenic insulation↗

Analysis of Seed Sanitization, Rapid Freezer Proficiency, and Veg-03 Water Verification

In order to ensure the well-being of astronauts and experiments on the ISS (International Space Station), seeds need to be free of microbes, the rapid freezer needs to be freezing biological samples evenly and proficiently, and the astronauts need to have accurate watering procedures for Veg-03 (the latest Phytotron for the Veggie (Vegetable Production System) project). Seed flight candidates were sanitized with varying levels of HCL in order to determine the right amount to use for future flight experiments, too much HCL and the seeds will not germinate and too little and they will be contaminated with microorganisms. The rapid freezer was assessed using temperature probes to determine if there is a homogeneous change in temperature in order to ensure the safe freezing of biological organisms. The plant watering procedures given to the astronauts were assessed in order to make sure that Veg-03 experiments are receiving the correct amount of water.

Hollingsworth, Savannah↗

Study of monopropellants for electrothermal thrusters: Design and fabrication task summary report

The feasibility of operating small thrust level electrothermal thrusters with monopropellants other than MIL-grade hydrazine was studied. Analytical study, design, and fabrication of demonstration thrusters was performed, and an evaluation test program was initiated to evaluate monopropellants with freezing points lower than MIL-grade hydrazine, and to determine their applicability to electrothermal thrusters for spacecraft attitude control. Five demonstration thrusters were fabricated to determine the feasibility of operation with monomethylhydrazine, Aerozine-50, 77 percent hydrazine-23 percent hydrazine azide, and a mixture of hydrazine monopropellants consisting of 35 percent hydrazine-50 percent monomethylhydrazine-15 percent ammonia. The present thruster is designed to produce a steady-state thrust level of 0.344 N at 1.724 x 1 million N/M sq feed pressure. Vacuum specific impulse goals were set at 1961 N-s/kg steady-state and 1716 N-s/kg pulsed-mode.

Kuenzly, J. D.↗