Absolute atomic oxygen and nitrogen densities in radio-frequency driven atmospheric pressure cold plasmas: Synchrotron vacuum ultra-violet high-resolution Fourier-transform absorption measurements

Reactive atomic species play a key role in emerging cold atmospheric pressure plasma applications, in particular, in plasma medicine. Absolute densities of atomic oxygen and atomic nitrogen were measured in a radio-frequency driven non-equilibrium plasma operated at atmospheric pressure using vacuum ultra-violet (VUV) absorption spectroscopy. The experiment was conducted on the DESIRS synchrotron beamline using a unique VUV Fourier-transform spectrometer. Measurements were carried out in plasmas operated in helium with air-like N{sub 2}/O{sub 2} (4:1) admixtures. A maximum in the O-atom concentration of (9.1 {+-} 0.7) Multiplication-Sign 10{sup 20} m{sup -3} was found at admixtures of 0.35 vol. %, while the N-atom concentration exhibits a maximum of (5.7 {+-} 0.4) Multiplication-Sign 10{sup 19} m{sup -3} at 0.1 vol. %.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Rietveld analysis and Fourier transform infrared spectra of the solid solutions [Eu{sub 2-x}M{sub x}][Sn{sub 2-x}M{sub x}]O{sub 7-3x/2} (M = Mg or Zn)

Two series of mixed oxides with formula [Eu{sub 2-x}M{sub x}][Sn{sub 2-x}M{sub x}]O{sub 7-3x/2} (M = Mg or Zn) have been synthesized. The study by X-ray diffraction and Fourier transform infrared spectroscopy shows that the solids obtained are new non-stoichiometric solid solutions with the pyrochlore type structure. For both series a decrease of the cell parameter is observed when the degree of substitution, x, increases. The structural refinements (X-ray studies) were achieved in the space group Fd-3m, no. 227 (origin at center -3m) by using the Fullprof software. The Rietveld refinements show that the divalent cations M{sup 2+} (Mg{sup 2+}, Zn{sup 2+}) substitute isomorphically for Eu{sup 3+} and Sn{sup 4+} ions producing vacancies in the anionic sublattice.

36 MATERIALS SCIENCE↗

Fourier transform infrared identification of the ν{sub 5}(σ{sub u}) fundamental of SiC{sub 5}Si

The Fourier transform infrared spectrum of SiC{sub 5}Si was observed by trapping the vapor from the Nd:YAG laser ablation of sintered Si/C rods in solid Ar at ∼20 K. Measurements of {sup 13}C and {sup 29,30}Si isotopic shifts have enabled the identification of the ν{sub 5}(σ{sub u}) vibrational fundamental of the linear isomer of SiC{sub 5}Si at 1590.8 ± 0.2 cm{sup −1}. The results are in excellent agreement with the predictions of density functional theory calculations at the B3LYP/cc-pVDZ level. A second fundamental, ν{sub 4}(σ{sub u}), can only be tentatively identified at 2021.0 cm{sup −1}, because its isotopic shifts are overlapped by absorptions from other species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reaction dynamics of O({sup 1}D) + HCOOD/DCOOH investigated with time-resolved Fourier-transform infrared emission spectroscopy

We investigated the reaction dynamics of O({sup 1}D) towards hydrogen atoms of two types in HCOOH. The reaction was initiated on irradiation of a flowing mixture of O{sub 3} and HCOOD or DCOOH at 248 nm. The relative vibration-rotational populations of OH and OD (1 ≦ v ≦ 4, J ≤ 15) states were determined from time-resolved IR emission recorded with a step-scan Fourier-transform spectrometer. In the reaction of O({sup 1}D) + HCOOD, the rotational distribution of product OH is nearly Boltzmann, whereas that of OD is bimodal. The product ratio [OH]/[OD] is 0.16 ± 0.05. In the reaction of O({sup 1}D) + DCOOH, the rotational distribution of product OH is bimodal, but the observed OD lines are too weak to provide reliable intensities. The three observed OH/OD channels agree with three major channels of production predicted with quantum-chemical calculations. In the case of O({sup 1}D) + HCOOD, two intermediates HOC(O)OD and HC(O)OOD are produced in the initial C−H and O−D insertion, respectively. The former undergoes further decomposition of the newly formed OH or the original OD, whereas the latter produces OD via direct decomposition. Decomposition of HOC(O)OD produced OH and OD with similar vibrational excitation, indicating efficient intramolecular vibrational relaxation, IVR. Decomposition of HC(O)OOD produced OD with greater rotational excitation. The predicted [OH]/[OD] ratio is 0.20 for O({sup 1}D) + HCOOD and 4.08 for O({sup 1}D) + DCOOH; the former agrees satisfactorily with experiments. We also observed the v{sub 3} emission from the product CO{sub 2}. This emission band is deconvoluted into two components corresponding to internal energies E = 317 and 96 kJ mol{sup −1} of CO{sub 2}, predicted to be produced via direct dehydration of HOC(O)OH and secondary decomposition of HC(O)O that was produced via decomposition of HC(O)OOH, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast dose kernel interpolation using Fourier transform with application to permanent prostate brachytherapy dosimetry

Purpose: Boyer and Mok proposed a fast calculation method employing the Fourier transform (FT), for which calculation time is independent of the number of seeds but seed placement is restricted to calculation grid points. Here an interpolation method is described enabling unrestricted seed placement while preserving the computational efficiency of the original method. Methods: The Iodine-125 seed dose kernel was sampled and selected values were modified to optimize interpolation accuracy for clinically relevant doses. For each seed, the kernel was shifted to the nearest grid point via convolution with a unit impulse, implemented in the Fourier domain. The remaining fractional shift was performed using a piecewise third-order Lagrange filter. Results: Implementation of the interpolation method greatly improved FT-based dose calculation accuracy. The dose distribution was accurate to within 2% beyond 3 mm from each seed. Isodose contours were indistinguishable from explicit TG-43 calculation. Dose-volume metric errors were negligible. Computation time for the FT interpolation method was essentially the same as Boyer's method. Conclusions: A FT interpolation method for permanent prostate brachytherapy TG-43 dose calculation was developed which expands upon Boyer's original method and enables unrestricted seed placement. The proposed method substantially improves the clinically relevant dose accuracy with negligible additional computation cost, preserving the efficiency of the original method.

61 RADIATION PROTECTION AND DOSIMETRY↗

Techniques for Handling and Removal of Spectral Channels in Fourier Transform Synchrotron-Based Spectra

Channel spectra are a big problem for those attempting to use synchrotron-based Fourier transform spectra for spectral lineshape studies. Due to the layout of the optical system at the CLS far-infrared beamline, the synchrotron beam undergoes unavoidable multiple reflections on the steering mirrors, beam splitter, several sets of windows, and filters. We present a method for eliminating channel spectra and compare the results of our technique with other methods available in the literature.

43 PARTICLE ACCELERATORS↗

Detection and Signal Processing for Near-Field Nanoscale Fourier Transform Infrared Spectroscopy

Researchers from a broad spectrum of scientific and engineering disciplines are increasingly using scattering-type near-field infrared spectroscopic techniques to characterize materials non-destructively with nanoscale spatial resolution. However, a sub-optimal understanding of a technique's implementation can complicate data interpretation and act as a barrier to entering the field. Here the key detection and processing steps involved in producing scattering-type near-field nanoscale Fourier transform infrared spectra (nano-FTIR) are outlined. The self-contained mathematical and experimental work derives and explains: i) how normalized complex-valued nano-FTIR spectra are generated, ii) why the real and imaginary components of spectra qualitatively relate to dispersion and absorption respectively, iii) a new and generally valid equation for spectra which can be used as a springboard for additional modeling of the scattering processes, and iv) an algebraic expression that can be used to extract an approximation to the sample's local extinction coefficient from nano-FTIR. The algebraic model for weak oscillators is validated with nano-FTIR and attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectra on samples of polystyrene and Kapton and further provides a pedagogical pathway to cementing some of the technique's key qualitative attributes.

36 MATERIALS SCIENCE↗

LABORATORY MEASUREMENTS OF NiH BY FOURIER TRANSFORM DISPERSED FLUORESCENCE

Red and orange bands of laser-induced fluorescence in NiH have been recorded on a Fourier transform interferometer at Doppler resolution. The spectra show strong transitions to low-lying vibronic states which are not thermally populated in a laboratory source, and therefore do not appear in laser excitation spectra, but which would be expected to contribute significantly to any stellar spectrum. The strongest bands belong to the G[{omega}' 5/2]-X {sub 2} {sup 2}{delta}{sub 3/2}, I[{omega}' 3/2]-X {sub 2}, and {sup 2}{delta}{sub 3/2} I[{omega}' 3/2]-W {sub 1} {sup 2}{pi}{sub 3/2} systems. Measurements are reported for {sup 58}NiH, {sup 60}NiH, and {sup 62}NiH.

79 ASTRONOMY AND ASTROPHYSICS↗

A prescription of Winograd's discrete Fourier transform algorithm

A detailed and complete description of Winograd's discrete Fourier transform algorithm (DFT) is presented omitting all proofs and derivations. The algorithm begins with the transfer of data from the input vector array to the working array where the actual transformation takes place, otherwise known as input scrambling and output unscrambling. The third array holds constraints required in the transformation stage that are evaluated in the precomputation stage. The algorithm is made up of several FORTRAN subroutines which are not to be confused with practical software algorithmic implementation since they are designed for clarity and not for speed.

Zohar, S.↗

Calibration of the Geostationary Imaging Fourier Transform Spectrometer (GIFTS)

The NASA New Millennium Program's Geostationary Imaging Fourier Transform Spectrometer (GIFTS) requires highly accurate radiometric and spectral calibration in order to carry out its mission to provide water vapor, wind, temperature, and trace gas profiling from geostationary orbit. A calibration concept has been developed for the GIFTS Phase A instrument design. The in-flight calibration is performed using views of two on-board blackbody sources along with cold space. A radiometric calibration uncertainty analysis has been developed and used to show that the expected performance for GIFTS exceeds its top level requirement to measure brightness temperature to better than 1 K. For the Phase A GIFTS design, the spectral calibration is established by the highly stable diode laser used as the reference for interferogram sampling, and verified with comparisons to atmospheric calculations.

Best, F. A.↗

A Discussion of Using a Reconfigurable Processor to Implement the Discrete Fourier Transform

This paper presents the design and implementation of the Discrete Fourier Transform (DFT) algorithm on a reconfigurable processor system. While highly applicable to many engineering problems, the DFT is an extremely computationally intensive algorithm. Consequently, the eventual goal of this work is to enhance the execution of a floating-point precision DFT algorithm by off loading the algorithm from the computing system. This computing system, within the context of this research, is a typical high performance desktop computer with an may of field programmable gate arrays (FPGAs). FPGAs are hardware devices that are configured by software to execute an algorithm. If it is desired to change the algorithm, the software is changed to reflect the modification, then download to the FPGA, which is then itself modified. This paper will discuss methodology for developing the DFT algorithm to be implemented on the FPGA. We will discuss the algorithm, the FPGA code effort, and the results to date.

White, Michael J.↗

Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS): Imaging and Tracking Capability

The geosynchronous-imaging Fourier transform spectrometer (GIFTS) engineering demonstration unit (EDU) is an imaging infrared spectrometer designed for atmospheric soundings. It measures the infrared spectrum in two spectral bands (14.6 to 8.8 microns, 6.0 to 4.4 microns) using two 128 128 detector arrays with a spectral resolution of 0.57/cm with a scan duration of approx. 11 seconds. From a geosynchronous orbit, the instrument will have the capability of taking successive measurements of such data to scan desired regions of the globe, from which atmospheric status, cloud parameters, wind field profiles, and other derived products can be retrieved. The GIFTS EDU provides a flexible and accurate testbed for the new challenges of the emerging hyperspectral era. The EDU ground-based measurement experiment, held in Logan, Utah during September 2006, demonstrated its extensive capabilities and potential for geosynchronous and other applications (e.g., Earth observing environmental measurements). This paper addresses the experiment objectives and overall performance of the sensor system with a focus on the GIFTS EDU imaging capability and proof of the GIFTS measurement concept.

Zhou, D. K.↗

Terahertz spectroscopy with a holographic Fourier transform spectrometer plus array detector using coherent synchrotron radiation

By use of coherent terahertz synchrotron radiation, we experimentally tested a holographic Fourier transform spectrometer coupled to an array detector to determine its viability as a spectral device. Somewhat surprisingly, the overall performance strongly depends on the absorptivity of the birefringent lithium tantalate pixels in the array detector.

43 PARTICLE ACCELERATORS↗

A Fourier transform method for Vsin i estimations under nonlinear Limb-Darkening laws

Star rotation offers us a large horizon for the study of many important physical issues pertaining to stellar evolution. Currently, four methods are widely used to infer rotation velocities, namely those related to line width calibrations, on the fitting of synthetic spectra, interferometry, and on Fourier transforms (FTs) of line profiles. Almost all of the estimations of stellar projected rotation velocities using the Fourier method in the literature have been addressed with the use of linear limb-darkening (LD) approximations during the evaluation of rotation profiles and their cosine FTs, which in certain cases, lead to discrepant velocity estimates. In this work, we introduce new mathematical expressions of rotation profiles and their Fourier cosine transforms assuming three nonlinear LD laws—quadratic, square-root, and logarithmic—and study their applications with and without gravity-darkening (GD) and geometrical flattening (GF) effects. Through an analysis of He I models in the visible range accounting for both limb and GD, we find out that, for classical models without rotationally driven effects, all the Vsin i values are too close to each other. On the other hand, taking into account GD and GF, the Vsin i obtained with the linear law result in Vsin i values that are systematically smaller than those obtained with the other laws. As a rule of thumb, we apply these expressions to the FT method to evaluate the projected rotation velocity of the emission B-type star Achernar (α Eri).

79 ASTRONOMY AND ASTROPHYSICS↗

Fuzzy Logic Classification of Imaging Laser Desorption Fourier Transform Mass Spectrometry Data

The fuzzy logic method is applied to classification of mass spectra obtained with an imaging internal source Fourier transform mass spectrometer (I2LD-FTMS). Traditionally, an operator uses the relative abundance of ions with specific mass-to-charge (m/z) ratios to categorize spectra. An operator does this by comparing the spectrum of m/z versus abundance of an unknown sample against a library of spectra from known samples. Automated positioning and acquisition allow the I2LD-FTMS to acquire data from very large grids, which would require classification of up to 3600 spectra per hour to keep pace with the acquisition. The tedious job of classifying numerous spectra generated in an I2LD-FTMS imaging application can be replaced by a fuzzy rule base if the cues an operator uses can be encapsulated. Appropriate methods for assigning fuzzy membership values for inputs (e.g., mass spectrum abundances) and choice of fuzzy inference operators to translate linguistic antecedent into confidence values for the consequence (or in this case the classification) is followed by using the maximum confidence and a necessary minimum threshold for making a crisp decision. This paper also describes a method for gathering statistics on ions, which are not currently used in the rule base, but which may be candidates for making the rule base more accurate and complete or to form new rule bases based on data obtained from known samples. A spatial method for classifying spectra with low membership values, based on neighboring sample classifications, is also presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Collision Cross Sections Using a Fourier Transform Electrostatic Linear Ion Trap Mass Spectrometer

Collision cross sections (CCSs) were determined from the frequency-domain linewidths in a Fourier transform electrostatic linear ion trap. With use of an ultrahigh-vacuum precision leak valve and nitrogen gas, transients were recorded as the background pressure in the mass analyzer chamber was varied between 4× 10{sup -8} and 7 × 10{sup -7} Torr. The energetic hard-sphere ion–neutral collision model, described by Xu and coworkers, was used to relate the recorded image charge to the CCS of the molecule. In lieu of our monoisotopically isolating the mass of interest, the known relative isotopic abundances were programmed into the Lorentzian fitting algorithm such that the linewidth was extracted from a sum of Lorentzians. Although this works only if the isotopic distribution is known a priori, it prevents ion loss, preserves the high signal-to-noise ratio, and minimizes the experimental error on our homebuilt instrument. Six tetraalkylammonium cations were used to correlate the CCS measured in the electrostatic linear ion trap with that measured by drift-tube ion mobility spectrometry, for which there was an excellent correlation (R{sup 2} ≈ 0.9999). Although the absolute CCSs derived with our method differ from those reported, the extracted linear correlation can be used to correct the raw CCS. With use of [angiotensin II]{sup 2+} and reserpine, the corrected CCSs (334.9 ± 2.1 and 250.1 ± 0.5, respectively) were in good agreement with the reported ion mobility spectrometry CCSs (335 and 254.3, respectively). With sufficient signal-to-noise ratio, the CCSs determined are reproducible to within a fraction of a percent, comparable to the uncertainties reported on dedicated ion mobility instruments. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗