Experimental investigation of unsteady flow dynamics in therminol-66 using edge tone-induced oscillations

Recent research has demonstrated that flow oscillations induced by a wedge positioned opposite the jet outlet in edge tones can be effectively utilized for flow measurement purposes. This highlights the necessity for developing advanced instrumentation capable of precise flow measurements in experimental setups exposed to radiation and in challenging fluids such as molten salts. Here, this study contributes to the existing body of knowledge by conducting experiments using Therminol-66, an effective surrogate for FLiBe under appropriate temperature conditions for nuclear applications, across a broad range of Reynolds numbers from 17,700 to 555,000. Experiments were conducted with Therminol-66 at approximately 368.8 K under atmospheric pressure, with varying flow rates. A reliable correlation was established between the generated frequencies, corresponding flow rates, and device geometry parameters. The data were subjected to non-dimensional analysis to reveal the interrelationships among flow rate, fluid properties, device geometry, and their impact on the acoustic tones produced by the edge tone device. These findings contribute to the development of precise flow measurement instrumentation for use in challenging environments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Planar Particle Imaging and Doppler Velocimetry System and Method

A planar velocity measurement system (100) is operative to measure all three velocity components of a flowing fluid (106) across an illuminated plane (108) using only a single line of sight. The fluid flow is seeded with small particles which accurately follow the flow field fluctuations. The seeded flow field is illuminated with pulsed laser light source (102) and the positions of the particles in the flow are recorded on CCD cameras (122,124). The in-plane velocities are measured by determining the in-plane particle displacements. The out-of-plane velocity component is determined by measuring the Doppler shift of the light scattered by the particles. Both gas and liquid velocities can be measured, as well as two-phase flows.

Wernet, Mark P.↗

Flow Visualization of Liquid Hydrogen Line Chilldown Tests

We present experimental measurements of wall and fluid temperature during chill-down tests of a warm cryogenic line with liquid hydrogen. Synchronized video and fluid temperature measurements are used to interpret stream temperature profiles versus time. When cold liquid hydrogen starts to flow into the warm line, a sequence of flow regimes, spanning from all-vapor at the outset to bubbly with continuum liquid at the end can be observed at a location far downstream of the cold inlet. In this paper we propose interpretations to the observed flow regimes and fluid temperature histories for two chilldown methods, viz. trickle (i.e. continuous) flow and pulse flow. Calculations of heat flux from the wall to the fluid versus wall temperature indicate the presence of the transition/nucleate boiling regimes only. The present tests, run at typical Reynolds numbers of approx O(10 (exp 5)), are in sharp contrast to similar tests conducted at lower Reynolds numbers where a well-defined film boiling region is observed.

Line chill down↗

Forecasting high-dimensional spatio-temporal systems from sparse measurements

This paper introduces a new neural network architecture designed to forecast high-dimensional spatio-temporal data using only sparse measurements. The architecture uses a two-stage end-to-end framework that combines neural ordinary differential equations (NODEs) with vision transformers. Initially, our approach models the underlying dynamics of complex systems within a low-dimensional space; and then it reconstructs the corresponding high-dimensional spatial fields. Many traditional methods involve decoding high-dimensional spatial fields before modeling the dynamics, while some other methods use an encoder to transition from high-dimensional observations to a latent space for dynamic modeling. In contrast, our approach directly uses sparse measurements to model the dynamics, bypassing the need for an encoder. This direct approach simplifies the modeling process, reduces computational complexity, and enhances the efficiency and scalability of the method for large datasets. We demonstrate the effectiveness of our framework through applications to various spatio-temporal systems, including fluid flows and global weather patterns. Although sparse measurements have limitations, our experiments reveal that they are sufficient to forecast system dynamics accurately over long time horizons. Our results also indicate that the performance of our proposed method remains robust across different sensor placement strategies, with further improvements as the number of sensors increases. This robustness underscores the flexibility of our architecture, particularly in real-world scenarios where sensor data is often sparse and unevenly distributed.

97 MATHEMATICS AND COMPUTING↗

Design of Fiber Optic Sensors for Measuring Hydrodynamic Parameters

The science of optical hydrodynamics involves relating the optical properties to the fluid dynamic properties of a hydrodynamic system. Fiber-optic sensors are being designed for measuring the hydrodynamic parameters of various systems. As a flowing fluid makes an encounter with a flat surface, it forms a boundary layer near this surface. The region between the boundary layer and the flat plate contains information about parameters such as viscosity, compressibility, pressure, density, and velocity. An analytical model has been developed for examining the hydrodynamic parameters near the surface of a fiber-optic sensor. An analysis of the conservation of momentum, the continuity equation and the Navier-Stokes equation for compressible flow were used to develop expressions for the velocity and the density as a function of the distance along the flow and above the surface. When examining the flow near the surface, these expressions are used to estimate the sensitivity required to perform direct optical measurements and to derive the shear force for indirect optical measurements. The derivation of this result permits the incorporation of better design parameters for other fiber-based sensors. Future work includes analyzing the optical parametric designs of fiber-optic sensors, modeling sensors to utilize the parameters for hydrodynamics and applying different mixtures of hydrodynamic flow. Finally, the fabrication of fiber-optic sensors for hydrodynamic flow applications of the type described in this presentation could enhance aerospace, submarine, and medical technology.

Lyons, Donald R.↗

Comparison of Tomo-PIV Versus Dual Plane PIV on a Synthetic Jet Flow

Particle Imaging Velocimetry (PIV) is a planar velocity measurement technique that has found widespread use across a wide class of engineering disciplines. Tomographic PIV (tomoPIV) is an extension of the traditional PIV technique whereby the velocity across a volume of fluid is measured. TomoPIV provides additional fluid mechanical properties of the flow due to the adjacent planes of velocity information that are extracted. Dual Plane PIV is another approach for providing cross-plane flow field properties. Dual Plane PIV and tomoPIV provide all of the same flow properties, albeit through very different routes with significantly different levels of effort, hence a comparison of their application and performance would prove beneficial in a well-known, highly three dimensional flow field. A synthetic jet flow which has a wide range of flow field features including high velocity gradients and regions of high vorticity was used as a rigorous test bed to determine the capabilities limitations of the Dual Plane PIV and tomoPIV techniques. The results show that compressing 3D particle field information down to a limited number of views does not permit the accurate reconstruction of the flow field. The traditional thin sheet techniques are the best approach for accurate flow field measurements.

Particle Image Velocimetry↗

In-situ thermodynamics measurements at metal oxides-solution interfaces using Flow Adsorption Microcalorimetry.

Mineral-fluid interfaces are the principal sites of geochemical processes near Earth’s surface, hosting chemical reactions that play a fundamental role in (bio)geochemical cycles and in the fate and transport of anthropogenic contaminants, and that effectively control the compositions of soil and water environments. These complex interfaces are critical for our energy and environmental future. The mineral-fluid interface has been studied in an unprecedented level of detail with both experimental and computational approaches, separately and in combination. However, conspicuously missing from studies of the mineral-fluid interface are direct measurements of the energies of ion sorption and exchange. The literature on energetics and enthalpies of exchange, adsorption, dissolution, precipitation, and surface protonation reactions, especially those directly supported by experimental data, remains scarce despite their fundamental nature. The overarching goal of this project is to complete a systematic study of the thermodynamics properties of interfacial reactions at four MO surfaces (Rutile (α-TiO2), Quartz (SiO2), boehmite (γ-AlOOH) and goethite (α-FeOOH)) through the application and construction of novel flow adsorption microcalorimetry techniques and instrumentations. These unique and specialized microcalorimeters will operate at various temperatures and solution chemical compositions allowing for in-situ measurements across metal oxides and ligands of various characteristics. The overall research goal will be accomplished by completing the following three specific objectives (O): O1) Determine the energetics of surface protonation and deprotonation, ion exchange and ligand sorption reactions; O2) Investigate the surface charge thermodynamic properties under a range of temperature and solution chemical compositions; and O3) Develop predictive trends of the interplay between MO structure, surface coverage and surface reactivity. In addition to key thermodynamics parameters, calorimetric measurements provide a wealth of mechanistic information about reactions energetics and kinetics, surface charge characteristics, and structure-reactivity or selectivity relationships, all obtained in-situ and in real-time. This report includes science highlights from various projects completed over the performance period of the project. Also listed are dissemination opportunities, people supported on the grant and the impact on available physical resources and the discipline as a whole.

58 GEOSCIENCES↗

Numerical Investigation of the Spark Discharge Process in a Crossflow

The present study numerically investigates the spark discharge process under crossflow conditions using a thermal equilibrium plasma solver that fully couples the electromagnetic physics and fluid dynamics in a computational framework. Numerical results are validated by the comparison with experimental data. Here, the spark discharge experiment is performed in a constant volume vessel using an inductive coil ignition system for automotive applications, and the evolution of the spark channel is measured using high-speed imaging. The crossflow in the gap between the spark-plug electrodes is generated by a rotating fan with two different fan speeds, and the flow velocity across the gap is characterized by particle image velocimetry (PIV) measurement. A computational fluid dynamics (CFD) solver is employed to simulate the crossflow and provide the flow field variables (velocity, pressure, temperature) to the plasma solver. The crossflow velocity predicted in the flow simulation agrees well with the PIV data in that the non-uniform velocity profiles at monitoring points are reproduced by the CFD code. With the crossflow initialization in the plasma solver, the simulated spark discharge process from the breakdown to spark discharge matches the experimental data, including the voltage and circuit waveforms and the high-speed images of the spark channel evolution. The stretch of spark channel captured by plasma simulations agrees with the measured data. The plasma simulation reveals that the mean temperature of the spark channel is maintained at 5000 K during the discharge phase, and the temperature varies along the spark channel so that the highest value is obtained at the spark root on the center electrode. Overall, the results presented in this paper are meant to provide valuable information about the properties of the plasma generated by the spark discharge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relating Hydro–Mechanical and Elastodynamic Properties of Dynamically Stressed Tensile–Fractured Rock in Relation to Applied Normal Stress, Fracture Aperture, and Contact Area

We exploit nonlinear elastodynamic properties of fractured rock to probe the micro-scale mechanics of fractures and understand the relation between fluid transport and fracture aperture under dynamic stressing. Experiments were conducted on rough, tensile-fractured Westerly granite subject to triaxial stresses. We measure fracture permeability for steady-state fluid flow with deionized water. Pore pressure oscillations are applied at amplitudes ranging from 0.2 to 1 MPa at 1 Hz frequency. During dynamic stressing we transmit ultrasonic signals through the fracture using an array of piezoelectric transducers (PZTs) to monitor evolution of interface properties. We examine the influence of fracture aperture and contact area by conducting measurements at effective normal stresses of 10–20 MPa. Additionally, the evolution of contact area with stress is characterized using pressure sensitive film. These experiments are conducted separately with the same fracture and map contact area at stresses from 9 to 21 MPa. The measurements are a proxy for “true” contact area for the fracture surface and we relate them to elastic properties using the calculated PZT sensor footprints via numerical modeling of Fresnel zones. We compare the elastodynamic response of the fracture using the stress-induced changes in ultrasonic wave velocities for transmitter-receiver pairs to image spatial variations in contact properties. We show that nonlinear elasticity and permeability enhancement decrease with increasing normal stress. Additionally, post-oscillation wave velocity and permeability exhibit quick recoveries toward pre-oscillation values. Estimates of fracture contact area (global and local) demonstrate that the elastodynamic and permeability responses are dominated by fracture topology.

58 GEOSCIENCES↗

Saturn's Magnetosphere and Properties of Upstream Flow at Titan: Preliminary Results

Using Cassini Plasma Spectrometer (CAPS) Ion Mass Spectrometer (IMS) measurements, we present the ion fluid properties and its ion composition of the upstream flow for Titan's interaction with Saturn's magnetosphere. A 3D ion moments algorithm is used which is essentially model independent with only requirement is that ion flow is within the CAPS IMS 2(pi) steradian field-of-view (FOV) and that the ion 'velocity distribution function (VDF) be gyrotropic. These results cover the period from TA flyby (2004 day 300) to T22 flyby (2006 363). Cassini's in situ measurements of Saturn's magnetic field show it is stretched out into a magnetodisc configuration for Saturn Local Times (SLT) centered about midnight local time. Under those circumstances the field is confined near the equatorial plane with Titan either above or below the magnetosphere current sheet. Similar to Jupiter's outer magnetosphere where a magnetodisc configuration applies, one expects the heavy ions within Saturn's outer magnetosphere to be confined within a few degrees of the current sheet while at higher magnetic latitudes protons should dominate. We show that when Cassini is between dusk-midnight-dawn local time and spacecraft is not within the current sheet that light ions (H, 142) tend to dominate the ion composition for the upstream flow. If true, one may expect the interaction between Saturn's magnetosphere, locally devoid of heavy ions and Titan's upper atmosphere and exosphere to be significantly different from that for Voyager 1, TA and TB when heavy ions were present in the upstream flow. We also present observational evidence for Saturn's magnetosphere interaction with Titan's extended H and H2 corona which can extend approx. 1 Rs from Titan.

Sittler, E. C., Jr.↗

The development of laser speckle velocimetry for the study of vortical flows

A new experimental technique commonly known as PIDV (particle image displacement velocity) was developed to measure an instantaneous two dimensional velocity fluid in a selected plane of the flow field. This technique was successfully applied to the study of several problems: (1) unsteady flows with large scale vortical structures; (2) the instantaneous two dimensional flow in the transition region of a rectangular air jet; and (3) the instantaneous flow over a circular bump in a transonic flow. In several other experiments PIDV is routinely used as a non-intrusive measurement technique to obtain instantaneous two dimensional velocity fields.

Krothapalli, A.↗

Flow physics

A discussion is presented on the coupling of computational analysis and experiment. It is believed that this coupling is critical in developing new aerodynamic insights. Additionally, new methods for analyzing and interpreting data are discussed. These methods need to be developed in small-scale research studies and then applied to large-scale technology programs. The specific objectives of this program are threefold: (1) provide definitive data sets for the assessment of numerical simulations to the Navier-Stokes equations; (2) incorporate advanced instrumentation to measure the spatial and temporal structure of fluid flows; and (3) develop true parallelism between computational and experimental research using the 'scientific workstation' concept. The discussion is presented in viewgraph form.

Davis, Sanford↗

Molecular Rayleigh Scattering Techniques Developed for Measuring Gas Flow Velocity, Density, Temperature, and Turbulence

Nonintrusive optical point-wise measurement techniques utilizing the principles of molecular Rayleigh scattering have been developed at the NASA Glenn Research Center to obtain time-averaged information about gas velocity, density, temperature, and turbulence, or dynamic information about gas velocity and density in unseeded flows. These techniques enable measurements that are necessary for validating computational fluid dynamics (CFD) and computational aeroacoustic (CAA) codes. Dynamic measurements allow the calculation of power spectra for the various flow properties. This type of information is currently being used in jet noise studies, correlating sound pressure fluctuations with velocity and density fluctuations to determine noise sources in jets. These nonintrusive techniques are particularly useful in supersonic flows, where seeding the flow with particles is not an option, and where the environment is too harsh for hot-wire measurements.

Mielke, Amy F.↗

Optical and acoustical measuring techniques

The paper reviews the techniques of laser and acoustic Doppler measurement of fluid velocities in confined and free flows. The main mathematical relations are presented, and some systems are studied. Resolution properties of coaxial, bistatic, and pulsed CO2 laser Doppler velocimeter systems are compared. Schematics for pulsed and continuous wave acoustic Doppler systems are discussed. Both of these types of systems benefit from using a bistatic configuration instead of a coaxial system. The pulsed systems avoid contamination of source noise by not sampling until after the source noise has passed the receiver. Comparison of wind velocity measured with a pulsed acoustic Doppler and with a boundary layer profile is made.

Cliff, W. C.↗

Experimental and Computational Characterization of a Modified Sioutas Cascade Impactor for Respirable Radioactive Aerosols

Oak Ridge National Laboratory is collecting and characterizing aerosols released when spent nuclear fuel (SNF) rods are fractured in bending. An aerosol collection system was designed and tested to collect respirable sized (<10 μm aerodynamic diameter [AED]) particulates inside a hot cell facility. The setup is a modified version of the commercially available Sioutas cascade impactor, to which additional stages were added to expand the aerosol collection range from 2.5 to ~15 μm AED. To accommodate the additional stages and specific test conditions, the operating flow rate for aerosol collection was reduced, and testing was conducted by using pressure drop measurements, surrogate dust collection, and particle size characterization. The fluid flow distribution within the cascade and its stages was simulated in STAR-CCM+, and the stage-wise pressure drops obtained using the computational fluid dynamics model were then compared to experimental data. Lagrangian particle simulations were also performed, and stage-wise collection statistics were obtained from the simulation for comparison with the experimental data obtained using SNF-surrogate dust particles. The results provide valuable insights into the stage-wise particle collection characteristics of the modified cascade impactor and can also be used to improve the prediction accuracy of the manufacturer-determined analytical correlations.

aerosol modeling↗

Spectroscopic Measurement Techniques for Aerospace Flows

The conditions that characterize aerospace flows are so varied, that a single diagnostic technique is not sufficient for its measurement. Fluid dynamists use knowledge of similarity to help categorize and focus on different flow conditions. For example, the Reynolds number represents the ratio of inertial to viscous forces in a flow. When the velocity scales, length scales, and gas density are large and the magnitude of the molecular viscosity is low, the Reynolds number becomes large. This corresponds to large scale vehicles (e.g Airbus A380), fast moving objects (e.g. artillery projectiles), vehicles in dense fluids (e.g. submarine in water), or flows with low dynamic viscosity (e.g. skydiver in air). In each of these cases, the inertial forces dominate viscous forces, and unsteady turbulent fluctuations in the flow variables are observed. In contrast, flows with small length scales (e.g. dispersion of micro-particles in a solid rocket nozzle), slow moving objects (e.g. micro aerial vehicles), flows with low density gases (e.g. atmospheric re-entry), or fluids with a large magnitude of viscosity (e.g. engine coolant flow), all have low Reynolds numbers. In these cases, viscous forces become very important and often the flows can be steady and laminar. The Mach number, which is the ratio of the velocity to the speed of sound in the medium, also helps to differentiate types of flows. At very low Mach numbers, acoustic waves travel much faster than the object, and the flow can be assumed to be incompressible (e.g. Cessna 172 aircraft). As the object speed approaches the speed of sound, the gas density can become variable (e.g. flow over wing of Learjet 85). When the object speed is higher than the speed of sound (Ma > 1), the presences of shock waves and other gas dynamic features can become important to the vehicle performance (e.g. SR-71 Blackbird). In the hypersonic flow regime (Ma > 5), large changes in temperature begin to affect flow properties, causing real-gas effects to occur (e.g. X-43 Scramjet). At even higher Mach numbers, chemistry and nonequilibrium effects come into play (e.g. Startdust re-entry capsule), further complicating the measurement. These limits can be predicted by calculating the ratio of chemical and thermal relaxation time to the flow time scales. Other non-dimensional numbers can be used to further differentiate types of aerospace flows.

Danehy, Paul M.↗

Microparticle analysis system and method

A device for analyzing microparticles is provided which includes a chamber with an inlet and an outlet for respectively introducing and dispensing a flowing fluid comprising microparticles, a light source for providing light through the chamber and a photometer for measuring the intensity of light transmitted through individual microparticles. The device further includes an imaging system for acquiring images of the fluid. In some cases, the device may be configured to identify and determine a quantity of the microparticles within the fluid. Consequently, a method for identifying and tracking microparticles in motion is contemplated herein. The method involves flowing a fluid comprising microparticles in laminar motion through a chamber, transmitting light through the fluid, measuring the intensities of the light transmitted through the microparticles, imaging the fluid a plurality of times and comparing at least some of the intensities of light between different images of the fluid.

Morrison, Dennis R.↗