Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flowmeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

210 records · Page 12

Deep-Sea Hydrothermal-Vent Sampler

An apparatus is being developed for sampling water for signs of microbial life in an ocean hydrothermal vent at a depth of as much as 6.5 km. Heretofore, evidence of microbial life in deep-sea hydrothermal vents has been elusive and difficult to validate. Because of the extreme conditions in these environments (high pressures and temperatures often in excess of 300 C), deep-sea hydrothermal- vent samplers must be robust. Because of the presumed low density of biomass of these environments, samplers must be capable of collecting water samples of significant volume. It is also essential to prevent contamination of samples by microbes entrained from surrounding waters. Prior to the development of the present apparatus, no sampling device was capable of satisfying these requirements. The apparatus (see figure) includes an intake equipped with a temperature probe, plus several other temperature probes located away from the intake. The readings from the temperature probes are utilized in conjunction with readings from flowmeters to determine the position of the intake relative to the hydrothermal plume and, thereby, to position the intake to sample directly from the plume. Because it is necessary to collect large samples of water in order to obtain sufficient microbial biomass but it is not practical to retain all the water from the samples, four filter arrays are used to concentrate the microbial biomass (which is assumed to consist of particles larger than 0.2 m) into smaller volumes. The apparatus can collect multiple samples per dive and is designed to process a total volume of 10 L of vent fluid, of which most passes through the filters, leaving a total possibly-microbe-containing sample volume of 200 mL remaining in filters. A rigid titanium nose at the intake is used for cooling the sample water before it enters a flexible inlet hose connected to a pump. As the water passes through the titanium nose, it must be cooled to a temperature that is above a mineral-precipitation temperature of 100 C but below the upper working temperature (230 C) of switching valves and tubes in the apparatus. The sample water then passes into a manifold tube, from whence the switching valves can direct the water through either a bypass tube or any one of the filter arrays, without contamination from a previous sample. Each filter array consists of series of filters having pore sizes decreasing in the direction of flow: 90-, 60-, 15-, and 7-micron prefilters and a large-surface-area 0.2-micron collection filter. All the filter taps are located between the intake and the bypass tube so that each time the bypass tube is used, the entire manifold tube is flushed as well.

Behar, Alberto E.↗

Chamber for Aerosol Deposition of Bioparticles

Laboratory apparatus is depicted that is a chamber for aerosol deposition of bioparticles on surfaces of test coupons. It is designed for primary use in inoculating both flat and three-dimensional objects with approximately reproducible, uniform dispersions of bacterial spores of the genus Bacillus so that the objects could be used as standards for removal of the spores by quantitative surface sampling and/or cleaning processes. The apparatus is also designed for deposition of particles other than bacterial spores, including fungal spores, viruses, bacteriophages, and standard micron-sized beads. The novelty of the apparatus lies in the combination of a controllable nebulization system with a settling chamber large enough to contain a significant number of test coupons. Several companies market other nebulizer systems, but none are known to include chambers for deposition of bioparticles to mimic the natural fallout of bioparticles. The nebulization system is an expanded and improved version of commercially available aerosol generators that include nebulizers and drying columns. In comparison with a typical commercial aerosol generator, this system includes additional, higher-resolution flowmeters and an additional pressure regulator. Also, unlike a typical commercial aerosol generator, it includes stopcocks for separately controlling flows of gases to the nebulizer and drying column. To maximize the degree of uniformity of dispersion of bioaerosol, the chamber is shaped as an axisymmetrical cylinder and the aerosol generator is positioned centrally within the chamber and aimed upward like a fountain. In order to minimize electric charge associated with the aerosol particles, the drying column is made of aluminum, the drying column is in direct contact with an aluminum base plate, and three equally spaced Po-210 antistatic strips are located at the exit end of the drying column. The sides and top of the chamber are made of an acrylic polymer; to prevent accumulation of electric charge on them, they are spray-coated with an anti-static material. During use, the base plate and the sides and top of the chamber are grounded as a further measure to minimize the buildup of electric charge.

Kern, Roger↗

Redesigned Human Metabolic Simulator

A design has been formulated for a proposed improved version of an apparatus that simulates atmospheric effects of human respiration by introducing controlled amounts of carbon dioxide, water vapor, and heat into the air. Denoted a human metabolic simulator (HMS), the apparatus is used for testing life-support equipment when human test subjects are not available. The prior version of the HMS, to be replaced, was designed to simulate the respiratory effects of as many as four persons. It exploits the catalytic combustion of methyl acetate, for which the respiratory quotient (the molar ratio of carbon dioxide produced to oxygen consumed) is very close to the human respiratory quotient of about 0.86. The design of the improved HMS provides for simulation of the respiratory effects of as many as eight persons at various levels of activity. The design would also increase safety by eliminating the use of combustion. The improved HMS (see figure) would include a computer that would exert overall control. The computer would calculate the required amounts of oxygen removal, carbon dioxide addition, water addition, and heat addition by use of empirical equations for metabolic profiles of respiration and heat. A blower would circulate air between the HMS and a chamber containing a life-support system to be tested. With the help of feedback from a mass flowmeter, the blower speed would be adjusted to regulate the rate of flow according to the number of persons to be simulated and to a temperature-regulation requirement (the air temperature would indirectly depend on the rate of flow, among other parameters). Oxygen would be removed from the circulating air by means of a commercially available molecular sieve configured as an oxygen concentrator. Oxygen, argon, and trace amounts of nitrogen would pass through a bed in the molecular sieve while carbon dioxide, the majority of nitrogen, and other trace gases would be trapped by the bed and subsequently returned to the chamber. If, as recommended, the oxygen concentrator were of a rotating twelve-bed design, then variations in the product stream could be made very small. Carbon dioxide would be added directly to the circulating air by simple injection from a supply tank. The rate of injection would be maintained at the required rate by use of a mass flowmeter/controller. In the same way, nitrogen would be added to make up for the small amount of nitrogen lost through the oxygen concentrator. Water vapor would be added to the circulating air by heating the corresponding required flow of water to steam in a heat exchanger. More heat, required to complete the simulation of the thermal effect of respiration, would be added through another heat exchanger. Heat would be supplied to both heat exchangers via a hot-oil loop.

Duffield, Bruce↗

Dual Cryogenic Capacitive Density Sensor

A dual cryogenic capacitive density sensor has been developed. The device contains capacitive sensors that monitor two-phase cryogenic flow density to within 1% accuracy, which, if temperature were known, could be used to determine the ratio of liquid to gas in the line. Two of these density sensors, located a known distance apart, comprise the sensor, providing some information on the velocity of the flow. This sensor was constructed as a proposed mass flowmeter with high data acquisition rates. Without moving parts, this device is capable of detecting the density change within a two-phase cryogenic flow more than 100 times a second. Detection is enabled by a series of two sets of five parallel plates with stainless steel, cryogenically rated tubing. The parallel plates form the two capacitive sensors, which are measured by electrically isolated digital electronics. These capacitors monitor the dielectric of the flow essentially the density of the flow and can be used to determine (along with temperature) the ratio of cryogenic liquid to gas. Combining this information with the velocity of the flow can, with care, be used to approximate the total two-phase mass flow. The sensor can be operated at moderately high pressures and can be lowered into a cryogenic bath. The electronics have been substantially improved over the older sensors, incorporating a better microprocessor, elaborate ground loop protection and noise limiting circuitry, and reduced temperature sensitivity. At the time of this writing, this design has been bench tested at room temperature, but actual cryogenic tests are pending

Youngquist, Robert↗

Semiautomated, Reproducible Batch Processing of Soy

A computer-controlled apparatus processes batches of soybeans into one or more of a variety of food products, under conditions that can be chosen by the user and reproduced from batch to batch. Examples of products include soy milk, tofu, okara (an insoluble protein and fiber byproduct of soy milk), and whey. Most processing steps take place without intervention by the user. This apparatus was developed for use in research on processing of soy. It is also a prototype of other soy-processing apparatuses for research, industrial, and home use. Prior soy-processing equipment includes household devices that automatically produce soy milk but do not automatically produce tofu. The designs of prior soy-processing equipment require users to manually transfer intermediate solid soy products and to press them manually and, hence, under conditions that are not consistent from batch to batch. Prior designs do not afford choices of processing conditions: Users cannot use previously developed soy-processing equipment to investigate the effects of variations of techniques used to produce soy milk (e.g., cold grinding, hot grinding, and pre-cook blanching) and of such process parameters as cooking times and temperatures, grinding times, soaking times and temperatures, rinsing conditions, and sizes of particles generated by grinding. In contrast, the present apparatus is amenable to such investigations. The apparatus (see figure) includes a processing tank and a jacketed holding or coagulation tank. The processing tank can be capped by either of two different heads and can contain either of two different insertable mesh baskets. The first head includes a grinding blade and heating elements. The second head includes an automated press piston. One mesh basket, designated the okara basket, has oblong holes with a size equivalent to about 40 mesh [40 openings per inch (.16 openings per centimeter)]. The second mesh basket, designated the tofu basket, has holes of 70 mesh [70 openings per inch (.28 openings per centimeter)] and is used in conjunction with the press-piston head. Supporting equipment includes a soy-milk heat exchanger for maintaining selected coagulation temperatures, a filter system for separating okara from other particulate matter and from soy milk, two pumps, and various thermocouples, flowmeters, level indicators, pressure sensors, valves, tubes, and sample ports

Thoerne, Mary↗

Data Reduction Functions for the Langley 14- by 22-Foot Subsonic Tunnel

The Langley 14- by 22-Foot Subsonic Tunnel's data reduction software utilizes six major functions to compute the acquired data. These functions calculate engineering units, tunnel parameters, flowmeters, jet exhaust measurements, balance loads/model attitudes, and model /wall pressures. The input (required) variables, the output (computed) variables, and the equations and/or subfunction(s) associated with each major function are discussed.

Boney, Andy D.↗

Developing Avionics Hardware and Software for Rocket Engine Testing

My summer was spent working as an intern at Kennedy Space Center in the Propulsion Avionics Branch of the NASA Engineering Directorate Avionics Division. The work that I was involved with was part of Rocket University's Project Neo, a small scale liquid rocket engine test bed. I began by learning about the layout of Neo in order to more fully understand what was required of me. I then developed software in LabView to gather and scale data from two flowmeters and integrated that code into the main control software. Next, I developed more LabView code to control an igniter circuit and integrated that into the main software, as well. Throughout the internship, I performed work that mechanics and technicians would do in order to maintain and assemble the engine.

liquid rocket↗

AM Powder Flowability Capabilities at NASA Marshall Space Flight Center (MSFC)

Additive Manufacturing (AM) powder flowability is critical to metal 3D printing, because the more fluid the powder is, the better powder spreads. The NASA MSFC’s Contamination Control Team (CCT) studies density, flow, particle size distribution, and morphology for programs such as Moon-to-Mars Planetary Autonomous Construction Technology (MMPACT), ASTM Proficiency Testing for AM and Powder Metallurgy, and MSFC’s AM team. Examining and measuring powder characteristics is essential for improving flowability of AM powder and ensuring lot-to-lot consistency, which will help to prevent defects in manufactured parts. The CCT uses several methods to characterize AM powder. Optical particle size distribution and morphology analyses determine particle parameters including size, circularity, convexity, and dimensions. The Carney and Hall Flowmeter Funnel measures time it takes powder to flow through a funnel to compare relative flowability (free-flowing and non-free-flowing). In addition to this, the device utilizes a density cup which determines apparent density. Lastly, the Revolution Powder Analyzer measures dynamic powder flowability and behavior over time via digital imaging. Using the CCT’s lab, the team has produced ASTM Powder Proficiency Testing results with flow rates, apparent density, particle size distribution, and tap density on titanium-based and nickel-based powder and compared data with other companies/labs. Morphology data was also collected for various regolith simulant powder for the MMPACT program. Lastly, the CCT used morphology data to examine the flowability of Inconel 718 powder for Selective Laser Melting (SLM) and Directed Energy Deposition (DED) printers at MSFC. The CCT’s essential work in studying and enabling AM powder characterization has helped and will continue to help study new and refined powders in the AM industry.

Additive Manufacturing↗

AM Powder Flowability Capabilities at NASA Marshall Space Flight Center (MSFC)

Additive Manufacturing (AM) powder flowability is critical to metal 3D printing, because the more fluid the powder is, the better powder spreads. AM Powder Flowability Capabilities at NASA MSFC studies density, flow, particle size distribution, and morphology for programs such as Moon-to-Mars Planetary Autonomous Construction Technology (MMPACT), ASTM Proficiency Testing for AM and Powder Metallurgy, and MSFC’s AM team. Examining and measuring powder characteristics is essential for improving flowability of AM powder and ensuring lot-to-lot consistency, which will help to prevent defects in manufactured parts. The Contamination Control Team (CCT) uses several methods to characterize AM powder. Optical particle size distribution and morphology analyses determine particle parameters including size, circularity, convexity, and dimensions. The Carney and Hall Flowmeter Funnel measures time it takes powder to flow through a funnel to compare relative flowability (free-flowing and non-free-flowing). In addition to this, the device utilizes a density cup which determines apparent density. Lastly, the Revolution Powder Analyzer measures dynamic powder flowability and behavior over time via digital imaging. Using the CCT’s lab, the team has produced ASTM Powder Proficiency Testing results with flow rates, apparent density, particle size distribution, and tap density on titanium-based and nickel-based powder and compared data with other companies/labs. Morphology data was also collected for various regolith simulant powder for the MMPACT program. Lastly, the CCT used morphology data to examine the flowability of Inconel 718 powder for Selective Laser Melting (SLM) and Directed Energy Deposition (DED) printers at MSFC. The CCT’s essential work in studying and enabling AM powder characterization has helped and will continue to help study new and refined powders in the AM industry.

Additive Manufacturing↗

A collaborative detection approach for internal steam leakage of tyre vulcanization workshop with artificial immune algorithm

In manufacturing industry, internal leakage of steam trap usually results in great steam waste. In particular, internal steam leakage in tyre vulcanization workshop has significant influences on its production safety and energy efficiency. In practice, internal steam leakage problem often is ignored and it tends to be difficult to detect this leakage due to lack of comprehensive flow meter or method. This paper presents a collaborative detection method for this problem in tyre vulcanization workshop with artificial immune algorithm. In the method, internal leakage of steam trap is defined as nonself antigens, and steam pressure differentials between steam pipe and steam rooms (or bladders) are extracted as epitopes of antigens. Furthermore, periodic energy efficiency and steam pressure of vulcanizer as the danger signals are simultaneously detected. Energy efficiency is represented by damaged cells which will be identified firstly for locating the leaking steam straps through antibodies. Furthermore, the self-adaptive danger thresholds for energy efficiency are evaluated through a steam consumption model and the Levenberg–Marquardt back propagation algorithm. An immune-based clustering algorithm aiNet is then adopted to generate antibodies (detectors) for detection on the steam pressure of vulcanizer. Finally, a case study is implemented to validate this method, which shows that collaborative detection method allows locating the specific leaking steam trap and is a feasible tool to reduce steam waste and ensure the safety of steam supply.

42 ENGINEERING↗

Measuring the Increment in the Free Volume of Composite Components

Various methods of measuring the increment in the free volume of composite components are considered, so as to assess which is most suitable for automation of such measurements as a function of the pressure within the component. A method permitting such measurements with high precision is found, and the corresponding instrument is described.

42 ENGINEERING↗

Coefficients of Flow of Standard Nozzles

We first undertook experiments with air, devoted principally to the investigation of the disturbances due to the differences in the nature of the flow to the nozzle. The difficulty of measuring the air, however, caused us to experiment with water. Due to the possibility of measuring the capacity of the container, this method was much more accurate than measuring with Pitot tobes.

FLOWMETERS, GAGES, ETC↗