Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Nevada national security site environmental remediation Large-Scale Multi-Well Aquifer Tests Used to Define Flow Systems - 15589

Over the past 5 years, 10 new groundwater wells have been drilled and hydraulically tested on Pahute Mesa Corrective Action Unit (CAU) under the Underground Test Area (UGTA) Activity at the Nevada National Security Site (NNSS). The new wells were drilled as part of a Phase II Corrective Action Investigation to gain a better understanding of the geology and hydrology of the system and to support development of a groundwater flow and transport model used for forecasting contaminant boundaries. Multi-well aquifer testing provides the most integrated assessment of hydraulic properties and connectivity within complex geologic systems. By providing hydraulic connectivity, these tests can be used to generate insight on potential contaminant flow paths and provide constraint on overall groundwater flow pathways. Drawdown in observation wells provides direct evidence of a hydraulic connection. During well drilling and testing activities, a total of 20 aquifer tests were conducted with as many as 36 individual completion zones. A signal-processing method developed by the U.S. Geological Survey was used to improve pumping drawdown detection. Using this approach, drawdown as far away as 3-4 kilometers has been detected. In addition to the typical analysis for hydraulic property values, the observed hydraulic connectivity are qualitatively and quantitatively used to inform the hydrogeologic framework model which is updated using other permissible geologic interpretations, when necessary, to incorporate the aquifer-testing results. These results will be used for developing and building confidence in the conceptual and numerical models for the Pahute Mesa CAU. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laboratory and Lysimeter Experimentation and Transport Modeling of Neptunium and Strontium in Savannah River Site Sediments

The Savannah River Site (SRS) conducts performance assessment (PA) calculations to determine the appropriate amount of low-level radiological waste that can be safely disposed on site. Parameters are included in these calculations that account for the interaction between the immobile solid phase and the mobile aqueous phase. These parameters are either the distribution coefficient (K$_{d}$ value) or the apparent solubility value (K$_{sp}$). These parameters are readily found in the literature and are used throughout the DOE complex. One shortcoming of K$_{d}$ values is that they are only applicable to a given set of solid and aqueous phase conditions. Therefore, a given radionuclide may have several K$_{d}$ values as it moves between formations and comes into contact with different solids and different aqueous phases. It is expected that the K$_{d}$ construct will be appropriate to use for a majority of the PA and for a majority of the radionuclides. However, semi-mechanistic models would be more representative in isolated cases where the chemistry is especially transitory or the radionuclide chemistry is especially complex, bringing to bear multiple species of varying sorption tendencies to the sediment. Semi-mechanistic models explicitly accommodate the dependency of K$_{d}$ values, or other sorption parameters, on contaminant concentration, competing ion concentrations, pH-dependent surface charge on the adsorbent, and solute species distribution. Incorporating semi-mechanistic concepts into geochemical models is desirable to make the models more robust and technically defensible. Furthermore, these alternative models could be used to augment or validate a K$_{d}$-based DOE Order 435.1 Performance Assessment. The objectives of this study were to: 1) develop a quantitative thermodynamically-based model for neptunium sorption to SRS sediments, and 2) determine a sorption constant from an SRS 11-year lysimeter study. The modeling studies were conducted with existing data sets. The first data set used laboratory generated Np sorption data as a function of concentration (three orders of magnitude) and as a function of pH (four orders of magnitude of proton concentration). In this modeling exercise, a very simple solution was identified by assuming that all sorption occurred only to the iron oxides in the sediment and that all the added NpO$_{4}$$^{-}$ remained in the oxidized state and was not reduced to the Np(IV) state (as occurs rapidly with Pu(V)). With rather limited input data, very good agreement between experimental and modeling results was observed. This modeling approach would be easy to add to the PA with little additional data requirements. This model would be useful in a system where pH is expected to change greatly, such as directly beneath a grout or concrete structure. The second model discussed in the report was to derive strontium K$_{d}$ values from data collected in an 11-year-old field transport study. In this controlled lysimeter study, a sensitivity analysis was conducted of hydrological and chemical processes that influence contaminant transport, including diffusion coefficients, seepage velocity, and K$_{d}$ value. The best overall K$_{d}$ derived from the model fit to the data was 32 L kg$^{-1}$, which was the same value that was previously measured in traditional laboratory batch sorption studies. This was an unexpected result given the differences in experimental conditions between the batch test and the lysimeter flow through test, in particular the differences between strontium adsorption and desorption processes occurring in the latter test and not in the former. There were some trends in the lysimeter strontium data that were not predicted by the K$_{d}$ model, which suggest that other geochemical processes are likely also controlling strontium transport. Strontium release and cation exchange are being evaluated. These results suggest that future modeling efforts (e.g., PAs) could be improved by employing a more robust semi-empirical modeling approach to transient or complex conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimized Test Section for Helium Flow Loop Experiment

Phase 3 of this project uses the knowledge and techniques gained from Phase 1 and Phase 2. The first outcome of Phase 3 is a new test section which can be manufactured and tested in the Helium Flow Loop Experiment to verify the results of the optimization study. The second outcome of Phase 3 is analyzing the features of this design and determining its performance under simulated TBM conditions: heat flux, pressure, mass flow rate, one-sided and volumetric heating. This will be accomplished by first using the results from the Phase 1 analyses and then applying the optimization strategy from Phase This phase uses the STAR-CCM+ Design Manager tool to apply the optimization strategy to the Helium Flow Loop Experiment (HFLE). The optimization algorithm used by the Design Manager tool is Simultaneous Hybrid Exploration that is Robust, Progressive, and Adaptive (SHERPA search algorithm). In addition to demonstrating the optimization features, a simple parameter sweep is also included in this phase. This report details the applied single objective optimization.

42 ENGINEERING↗

Analysis of Transient Groundwater Flow Near the Cheshire Test at Pahute Mesa, Nevada National Security Site

This report focuses on analysis and determination of the causes of transient water levels measured between 1964 and 2017 near the Cheshire underground nuclear test, which was detonated on February 14, 1976 in Area 20 (USDOE, 2015) of the Pahute Mesa (PM) testing areas of the Nevada National Security Site (NNSS) located in southern Nevada (Figure 1). Transient water levels near Cheshire indicate influences of a water-production well and yet-unexplained water level rise attributed to testing effects (Jackson and Fenelon, 2018; Jackson et al. 2021). Transient groundwater flow is relevant to the implementation of the hydrologic source term (HST), which prescribes the quantity and release rates of radionuclide source terms to be applied at individual test locations in assessment of regional-scale radionuclide transport (Carle and Tompson, 2021; Carle et al., 2021), as previously investigated for NNSS testing areas at PM (Pawloski et al., 2001), Frenchman Flat (Carle et al, 2007), Yucca Flat (Mcnab, 2009; Tompson, 2009), and Rainier Mesa (Carle, 2011; Tompson et al., 2011).

54 ENVIRONMENTAL SCIENCES↗

Analysis of Transient Groundwater Flow Near the Cheshire Test at Pahute Mesa, Nevada National Security Site

This report focuses on analysis and determination of the causes of transient water levels measured between 1964 and 2017 near the Cheshire underground nuclear test, which was detonated on February 14, 1976 in Area 20 (USDOE, 2015b) of the Pahute Mesa (PM) testing areas of the Nevada National Security Site (NNSS) located in southern Nevada (Figure 1). Transient water levels near Cheshire indicate influences of a water-production well and yet-unexplained water level rise attributed to testing effects (Jackson and Fenelon, 2018; Jackson et al. 2021). Transient groundwater flow is relevant to the implementation of the hydrologic source term (HST), which prescribes the quantity and release rates of radionuclide source terms to be applied at individual test locations in assessment of regional-scale radionuclide transport (Carle and Tompson, 2021; Carle et al., 2021), as previously investigated for NNSS testing areas at PM (Pawloski et al., 2001), Frenchman Flat (Carle et al, 2007), Yucca Flat (Carle et al., 2009; Mcnab, 2009; Tompson et al., 2009), and Rainier Mesa (Carle, 2011; Tompson et al., 2011).

54 ENVIRONMENTAL SCIENCES↗

4D Electrical Resistivity Imaging of Stress Perturbations Induced During High–Pressure Shear Stimulation Tests

Fluid flow through fractured media is typically governed by the distribution of fracture apertures, which are in turn governed by stress. Consequently, understanding subsurface stress is critical for understanding and predicting subsurface fluid flow. Although laboratory–scale studies have established a sensitive relationship between effective stress and bulk electrical conductivity in crystalline rock, that relationship has not been extensively leveraged to monitor stress evolution at the field scale using electrical or electromagnetic geophysical monitoring approaches. In this paper we demonstrate the use time–lapse 3–dimensional (4D) electrical resistivity tomography to image perturbations in the stress field generated by pressurized borehole packers deployed during shear–stimulation attempts in a 1.25 km deep metamorphic crystalline rock formation.

58 GEOSCIENCES↗

Reservoir response to thermal and high-pressure well stimulation efforts at Raft River, Idaho

An injection stimulation test begun at the Raft River geothermal reservoir in June, 2013 has produced a wealth of data describing well and reservoir response via high-resolution temperature logging and distributed temperature sensing, seismic monitoring, periodic borehole televiewer logging, periodic stepped flow rate tests and tracer injections before and after stimulation efforts. One of the primary measures of response to the stimulation is the relationship between fluid pressure and flow rate, short-term during forced flow rate changes and the long-term change in injectivity. In this paper we examine that hydraulic response using standard pumping test analysis methods, largely because pressure response to the stimulation was not detected, or measurable, in other wells. Analysis of stepped rate flow tests supports the inference from other data that a large fracture, with a radial extent of one to several meters, intersects the well in the target reservoir, suggests that the flow regime is radial to a distance of only several meters and demonstrates that the pressure build-up cone reaches an effective constant head at that distance. The well’s longer term hydraulic response demonstrated continually increasing injectivity but at a dramatically faster rate later from ~2 years out and continuing to the present. The net change in injectivity is significantly greater than observed in other longterm injectivity monitoring studies, with an approximately 150–fold increase occurring over ~2.5 years. While gradually increasing injectivity is a likely consequence of slow migration of a cooling front, and consequent dilation of fractures, the steady, ongoing, rate of increase is contrary to what would be expected in a radial or linear flow regime, where the cooling front would slow with time. As a result, occasional step-like changes in injectivity, immediately following high-flow rate tests suggest that hydro shearing during high-pressure testing altered the near-well permeability structure.

15 GEOTHERMAL ENERGY↗

Flow visualization methods for field test verification of CFD analysis of an open gloveport

Anemometer readings alone cannot provide a complete picture of air flow patterns at an open gloveport. Having a means to visualize air flow for field tests in general provides greater insight by indicating direction in addition to the magnitude of the air flow velocities in the region of interest. Furthermore, flow visualization is essential for Computational Fluid Dynamics (CFD) verification, where important modeling assumptions play a significant role in analyzing the chaotic nature of low-velocity air flow. A good example is shown Figure 1, where an unexpected vortex pattern occurred during a field test that could not have been measured relying only on anemometer readings. Here by, observing and measuring the patterns of the smoke flowing into the gloveport allowed the CFD model to be appropriately updated to match the actual flow velocities in both magnitude and direction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Excerpt from Oxygen Monitor Clean Testing Report Performed in 2010

The Rosemount X-STREAM Series X2GP is a paramagnetic oxygen analyzer with a 0-25% oxygen measurement range. It claims a drift less than 2% of span (0.10% volume oxygen) per week, and a response time of less than 5 seconds (for the analyzer to report 90% of a step change). Our test equipment was set-up such that the same gas was running through each oxygen analyzer at the same time. This allowed Calibration Error, Calibration Drift, and Loss of Power Testing to be run on all monitors at the same time, eliminating any variability between the analyzers from tolerances in the gas cylinder, ambient temperature, ambient pressure, test duration, etc. An APTech pressure regulator was placed on the gas cylinder manifold and a 23 psia Paroscientific pressure transducer measured the regulator’s outlet pressure. This did not give the inlet pressure on any one analyzer but outlet pressure from the manifold before the stream was split. The APTech pressure regulator was used to keep operating conditions consistent. A DWYER rotameter was installed on each oxygen monitor’s outlet piping. With the exception of Variation of Flow Rate Testing, the rotameter was left fully open for all testing. The flow rate through each oxygen monitor was controlled by a Swagelok needle valve that was installed on each analyzer’s inlet piping. Additionally, a filter was installed in the each monitor’s inlet piping to keep particles from the measurement cells and a Swagelok ball valve was installed on each monitor’s outlet piping to isolate each monitor between tests. No pumps were installed. Each of the cylinders used was at a pressure greater than ambient room barometric pressure. This pressure differential was used to move gas through the testing equipment. The flow rate through each analyzer was controlled by the Swagelok needle valve installed on each analyzer’s inlet piping. Finally, for all tests, a Paroscientific Digiquartz Barometer was used to measure ambient room barometric pressure and a Fluke Thermo-hygrometer was used to measure ambient room temperature.

47 OTHER INSTRUMENTATION↗

Testing Pollen Sorted by Flow Cytometry as the Basis for High-Resolution Lacustrine Chronologies

Documenting leads and lags in terrestrial records of past climate change is critical to understanding the behavior of Earth’s natural climate system and making reliable predictions of future climate conditions. However, uncertainties of several hundred years in age models make it difficult to distinguish synchronicity and feedbacks in paleo archives. In lakes this is often due to the lack of terrestrial macrofossils in climate-sensitive locations, such as high alpine or dryland settings. The potential of radiocarbon (14C) dating of pollen has long been recognized, but the difficulty of cleanly separating pollen from other kinds of organic carbon has limited its usefulness. Here we report 14C ages on pollen separated by flow cytometry, from a set of closely spaced samples from Mono Lake, California. The accuracy of the pollen ages is tested using well-dated bracketing tephras, the South Mono and North Mono-Inyo tephras. In spite of the purity of the sorted samples, the pollen dates are older than the bounding tephras by ~400 yr, similar to some other pollen-dating studies. While improvements in sample preparation protocols are planned, understanding the geological processes involved in the production, preservation, and deposition of pollen at each site will be critical to developing robust high-resolution age models.

58 GEOSCIENCES↗

Flow reversal benchmark of a one-sided heated narrow rectangular channel with CATHARE and RELAP5

Flow reversal in narrow coolant channels can be a crucial phenomenon for the safety of research reactors with a downward nominal flow direction. During a loss of forced flow accident, the downward flow stagnates briefly before transitioning into an upward natural circulation flow. The fuel may be damaged if dryout occurs and threshold fuel and/or cladding temperatures are exceeded. A comprehensive study is provided for flow reversal in narrow rectangular channels by examining experimental data and conducting software model analyses. The literature on flow reversal was reviewed, and selected experimental datasets were used to benchmark against CATHARE and RELAP5 models and also compare the code calculations with each other. The experimental data comes from flow reversal tests conducted with a narrow rectangular channel with one-sided heating. The results were compared with experimental data for successful flow reversal tests and predicted dryout power for dryout conditions. Also, the study examined the effects of the pump coastdown period, inlet liquid temperature, system pressure, and localized pressure drops. The experimental results showed that shorter coastdown periods, reduced pressure drops, and lower coolant inlet temperatures increased the dryout power. However, the system pressure did not noticeably affect the results. The simulation results showed that both CATHARE and RELAP5 agreed with experimental data, capturing the trends of the experimental results. Slight differences between each code calculation, as well as the predicted and measured dryout powers, were attributed to experimental uncertainties and the modeling of physical phenomena such as wall nucleation, interfacial heat transfer, drag coefficients, and critical heat flux. Overall, this study provides an understanding of flow reversal and the prediction capabilities of thermal-hydraulics software models. In conclusion, a future study of the flow reversal benchmark of a narrow rectangular channel with two-sided heating may provide additional valuable insights.

CATHARE↗

IR-thermography-based investigation of critical heat flux in subcooled flow boiling of water at atmospheric and high pressure conditions

Here we report on MIT’s THM work in Q4 2016 and Q1 2017. The goal of this project is to design, construct and execute tests of flow boiling critical heat flux (CHF) at high-pressure using high-resolution and high-speed video and infrared (IR) thermometry, to generate unique data to inform the development of and validate mechanistic boiling heat transfer and CHF models. In FY2016, a new test section was designed and fabricated. Data was collected at atmospheric conditions at 10, 25 and 50 K subcoolings, and three mass fluxes, i.e. 500, 750 and 1000 kg/m2/s. Starting in Q4 2016 and continuing forward, new post-processing techniques have been developed to analyze the data collected. These new algorithms analyze the time-dependent temperature and heat flux distributions to calculate nucleation site density, nucleation frequency, growth and wait time, dry area fraction, and the complete heat flux partitioning. In Q1 2017 a new flow boiling loop was designed and constructed to support flow boiling tests up 10 bar pressure and 180 °C. Initial shakedown and testing has been completed. The flow loop and test section are now ready to begin high-pressure flow boiling testing.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Waste Water for Power Generation via Energy Efficient Selective Silica Separations

Silica is ubiquitous in produced and industrial waters, and plays a major disruptive role in water recycle. Herein we have investigated the use of mixed oxides for the removal of silica from these waters, and their incorporation into a low cost and low energy water purification process. High selectivity hydrotalcite (HTC, (Mg 6 Al 2 (OH) 16 (CO 3 )•4H 2 O)), is combined in series with high surface area active alumina (AA, (Al 2 O 3 )) as the dissolved silica removal media. Batch test results indicated that combined HTC/AA is a more effective method for removing silica from industrial cooling tower wasters (CTW) than using HTC or AA separately. The silica uptake via ion exchange on the mixed oxides was confirmed by Fourier transform infrared (FTIR), and Energy dispersive spectroscopy (EDS). Furthermore, HTC/AA effectively removes silica from CTW even in the presence of large concentrations of competing anions, such as Cl - , NO 3 - HCO 3 - , CO 3 2- and SO 4 2- . Similar to batch tests, Single Path Flow Through (SPFT) tests with sequential HTC/AA column filtration has very high silica removal too. Technoeconomic Analysis (TEA) was simultaneously performed for cost comparisons to existing silica removal technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reservoir Response to Thermal and High-Pressure Well Stimulation Efforts at Raft River, Idaho

An injection stimulation test begun at the Raft River geothermal reservoir in June, 2013 has produced a wealth of data describing well and reservoir response via high-resolution temperature logging and distributed temperature sensing, seismic monitoring, periodic borehole televiewer logging, periodic stepped flow rate tests and tracer injections before and after stimulation efforts. The hydraulic response demonstrates continually increasing injectivity, reflected in varying flow rate response to nearly constant injection pressure, but features of the hydraulic response provide information about different characteristics of the reservoir. Changes in injectivity immediately following high-flow rate tests suggest that hydro shearing has altered the near-well permeability structure, while pressure response during those tests indicates that near-well permeability is relatively homogeneous and low but that the well is near, but not well connected to, a zone of higher transmissivity. Long-term changes in injectivity are believed to reflect propagation of the injection cooling front through low permeability zones. Two dimensional flow and heat transport simulations are used to demonstrate how the timescale of pressure response may relate to length scales of permeability distribution.

Well stimulation, injectivity, enhanced geothermal↗

Experimental investigation of two-phase flow in rock salt

This Test Plan describes procedures for conducting laboratory scale flow tests on intact, damaged, crushed, and consolidated crushed salt to measure the capillary pressure and relative permeability functions. The primary focus of the tests will be on samples of bedded geologic salt from the WIPP underground. However, the tests described herein are directly applicable to domal salt. Samples being tested will be confined by a range of triaxial stress states ranging from atmospheric pressure up to those approximating lithostatic. Initially these tests will be conducted at room temperature, but testing procedures and equipment will be evaluated to determine adaptability to conducting similar tests under elevated temperatures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technetium Retention in WTP LAW Glass with Recycle Flow-Sheet: DMIO Melter Testing

Melter tests were conducted to determine the retention of technetium and other volatiles in glass while processing simulated Low Activity Waste (LAW) streams through a DM10 melter equipped with a prototypical off-gas system that concentrates and recycles fluid effluents back to the melter feed. To support these tests, an existing DM10 system installed at Vitreous State Laboratory (VSL) was modified to add the required recycle loop. Based on the Hanford Tank Waste Treatment and Immobilization Plant (WTP) LAW off-gas system design, suitably scaled versions of the Submerged Bed Scrubber (SBS), Wet Electrostatic Precipitator (WESP), and TLP vacuum evaporator were designed, built, and installed into the DM10 system. Process modeling was used to support this design effort and to ensure that issues associated with the short half life of the 99m Tc radioisotope that was used in this work were properly addressed and that the system would be capable of meeting the test objectives. In particular, this required that the overall time constant for the system was sufficiently short that a reasonable approach to steady state could be achieved before the 99m Tc activity dropped below the analytical limits of detection. The conceptual design, detailed design, flow sheet development, process model development, Piping and Instrumentation Diagram (P&ID) development, control system design, software design and development, system fabrication, installation, procedure development, operator training, and Test Plan development for the new system were all conducted during this project. The new system was commissioned and subjected to a series of shake-down tests before embarking on the planned test program. Various system performance issues that arose during testing were addressed through a series of modifications in order to improve the performance and reliability of the system. The resulting system provided a robust and reliable platform to address the test objectives.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Critical feature and seawater testing of cross-flow rotor components fabricated with additive manufacturing

Advanced manufacturing (AM) materials were investigated for their suitability for use in cross-flow turbine rotors. AM materials were categorized into 3 classes – plastics, metals, and ceramics – and reviewed for suitability based on a set of engineering requirements and criteria. Two plastics and two metals were selected to undergo further testing: Essentium CF25, Markforged Onyx, Titanium Ti-6Al-4V, and Inconel 718. Dogbone-shaped specimens were printed from each material in two sets. The first set was tensile tested to get a material baseline. The second set was submerged in the seawater tanks at PNNL-Sequim for 6 months to determine water uptake, corrosion, and biofouling resistance and then subsequently tensile tested. While few macroscopic changes could be observed after seawater testing, the plastic materials degraded significantly as compared to baseline, while the metal material properties remained consistent. Titanium and Inconel are used consistently by industry in extreme conditions, and the materials show promising performance for marine energy use cases.

McVey, James R.↗