Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Interseismic Ground Deformation and Fault Slip Rates in the Greater San Francisco Bay Area From Two Decades of Space Geodetic Data

The detailed spatial variations of strain accumulation and creep on major faults in the northern San Francisco Bay Area (North Bay), which are important for seismic potential and evaluation of natural hazards, remain poorly understood. We combine interferometric synthetic aperture radar data from the ERS-1/2 and Envisat satellites between 1992 and 2010 with continuous and campaign GPS data to obtain a high spatial and temporal coverage of ground deformation of the North Bay. The SAR data from both ascending and descending orbits are combined to separate horizontal and vertical components of the deformation. We jointly invert the horizontal component of the mean velocities derived from these data to infer the deep strike-slip rates on major locked faults. We use the estimated deep rates to simulate the long-wavelength deformation due to interseismic elastic strain accumulation along these locked faults. After removing the long-wavelength signal from the InSAR horizontal mean velocity field, we estimate fault-parallel surface creep rates of up to 2 mm/year along the central section of the Rodgers Creek fault and surface creep rates ranging between 2 and 4 mm/year along the Concord fault. No surface creep is geodetically resolved along the West Napa and Green Valley fault zones. We identified characteristically repeating earthquakes on the Rodgers Creek fault, the West Napa fault, the Green Valley fault, and the Concord fault. Finally, nontectonic deformation in the Geysers geothermal field and in Late Cenozoic basins (Rohnert Park and Sonoma basins) are also observed, likely due to hydrological and sediment-compaction processes, respectively.

58 GEOSCIENCES↗

Internal structure of the San Jacinto fault zone at Blackburn Saddle from seismic data of a linear array

Local and teleseismic earthquake waveforms recorded by a 180-m-long linear array (BB) with seven seismometers crossing the Clark fault of the San Jacinto fault zone northwest of Anza are used to image a deep bimaterial interface and core damage structure of the fault. Delay times of P waves across the array indicate an increase in slowness from the southwest most (BB01) to the northeast most (BB07) station. Automatic algorithms combined with visual inspection and additional analyses are used to identify local events generating fault zone head and trapped waves. The observed fault zone head waves imply that the Clark fault in the area is a sharp bimaterial interface, with lower seismic velocity on the southwest side. The moveout between the head and direct P arrivals for events within ~40 km epicentral distance indicates an average velocity contrast across the fault over that section and the top 20 km of 3.2 per cent. A constant moveout for events beyond ~40 km to the southeast is due to off-fault locations of these events or because the imaged deep bimaterial interface is discontinuous or ends at that distance. The lack of head waves from events beyond ~20 km to the northwest is associated with structural complexity near the Hemet stepover. Events located in a broad region generate fault zone trapped waves at stations BB04–BB07. Waveform inversions indicate that the most likely parameters of the trapping structure are width of ~200 m, S velocity reduction of 30–40 per cent with respect to the bounding blocks, Q value of 10–20 and depth of ~3.5 km. The trapping structure and zone with largest slowness are on the northeast side of the fault. The observed sense of velocity contrast and asymmetric damage across the fault suggest preferred rupture direction of earthquakes to the northwest. This inference is consistent with results of other geological and seismological studies.

58 GEOSCIENCES↗

Late Quaternary slip-rate along the central Bangong-Chaxikang segment of the Karakorum fault, western Tibet

Insight into the spatial and temporal changes of slip-rate is essential to understand the kinematic role of large strike-slip faults in continental collision zones. Geodetic and geologic rates from present to several million years ago along the Karakorum fault range from 0 to 11 mm/yr. Here, we determine the first late Quaternary slip-rate at the southern end of the linear Bangong-Chaxikang segment of the Karakorum fault, using cumulative offsets (20–200 m) of fans and terraces at three sites, as well as 74 new 10 Be surface-exposure ages to constrain the age of these offset geomorphic markers. The rate is >3 mm/yr at sites Gun and Chaxikang, and it is >1.7–2.2 mm/yr at the Gar fan site. Together with rates obtained along the southernmost Menshi-Kailas segment, the Karakorum fault slip-rate seems to increase southeastward from south of Bangong Lake to Kailas (from >3 to >8 mm/yr). These Karakorum fault slip-rate data (>3–8 mm/yr), together with the total length of the fault (>1000 km) and its initiation age (>13–23 Ma), confirm that the Karakorum fault is the major fault accommodating dextral strike-slip motion NE of the western Himalayas. Furthermore, the dextral Karakorum fault in the south and the conjugate left-lateral Longmu Co–Altyn Tagh fault system in the north are thus the major strike-slip faults of western Tibet, which contribute to eastward extrusion of Tibet.

58 GEOSCIENCES↗

What does fault tolerant Deep Learning need from MPI?

Deep Learning (DL) algorithms have become the {\em de facto} Machine Learning (ML) algorithm for large scale data analysis. DL algorithms are computationally expensive -- even distributed DL implementations which use MPI require days of training (model learning) time on commonly studied datasets. Long running DL applications become susceptible to faults -- requiring development of a fault tolerant system infrastructure, in addition to fault tolerant DL algorithms. This raises an important question: {\em What is needed from MPI for designing fault tolerant DL implementations?} In this paper, we address this problem for permanent faults. We motivate the need for a fault tolerant MPI specification by an in-depth consideration of recent innovations in DL algorithms and their properties, which drive the need for specific fault tolerance features. We present an in-depth discussion on the suitability of different parallelism types (model, data and hybrid); a need (or lack thereof) for check-pointing of any critical data structures; and most importantly, consideration for several fault tolerance proposals (user-level fault mitigation (ULFM), Reinit) in MPI and their applicability to fault tolerant DL implementations. We leverage a distributed memory implementation of Caffe, currently available under the Machine Learning Toolkit for Extreme Scale (MaTEx). We implement our approaches by extending MaTEx-Caffe for using ULFM-based implementation. Our evaluation using the ImageNet dataset and AlexNet neural network topology demonstrates the effectiveness of the proposed fault tolerant DL implementation using OpenMPI based ULFM.

Amatya, Vinay C.↗

OpenStudio® Fault Models Gem [SWR-15-23]

Overview of the OpenStudio® Fault Models Gem: Creating a comprehensive library of OpenStudio® fault models. Features: - Physics-based fault impact simulation within the capability of EnergyPlus®/OpenStudio® - Fault intensity implementation simulating how severe faults are (e.g., how much portion is fouled in the condenser heat exchanger) and estimating the impact of a fault in different fault intensities. - Fault evolution implementation simulating evolving/increasing fault intensity through certain period of time. Future goals: - what are common/typical faults in different sample spaces (e.g., HVAC system type, building operation type, building location etc.)? - how often (e.g., incidence and prevalence) faults occur in different sample spaces (e.g., HVAC system type, building operation type, building location etc.)?

Frank, Stephen↗

Series and parallel arc-fault circuit interrupter tests.

While the 2011 National Electrical Codeª (NEC) only requires series arc-fault protection, some arc-fault circuit interrupter (AFCI) manufacturers are designing products to detect and mitigate both series and parallel arc-faults. Sandia National Laboratories (SNL) has extensively investigated the electrical differences of series and parallel arc-faults and has offered possible classification and mitigation solutions. As part of this effort, Sandia National Laboratories has collaborated with MidNite Solar to create and test a 24-string combiner box with an AFCI which detects, differentiates, and de-energizes series and parallel arc-faults. In the case of the MidNite AFCI prototype, series arc-faults are mitigated by opening the PV strings, whereas parallel arc-faults are mitigated by shorting the array. A range of different experimental series and parallel arc-fault tests with the MidNite combiner box were performed at the Distributed Energy Technologies Laboratory (DETL) at SNL in Albuquerque, NM. In all the tests, the prototype de-energized the arc-faults in the time period required by the arc-fault circuit interrupt testing standard, UL 1699B. The experimental tests confirm series and parallel arc-faults can be successfully mitigated with a combiner box-integrated solution.

Johnson, Jay Dean↗

Award ER25750: Coordinated Infrastructure for Fault Tolerance Systems Indiana University Final Report

The main purpose of the Coordinated Infrastructure for Fault Tolerance in Systems initiative has been to conduct research with a goal of providing end-to-end fault tolerance on a systemwide basis for applications and other system software. While fault tolerance has been an integral part of most high-performance computing (HPC) system software developed over the past decade, it has been treated mostly as a collection of isolated stovepipes. Visibility and response to faults has typically been limited to the particular hardware and software subsystems in which they are initially observed. Little fault information is shared across subsystems, allowing little flexibility or control on a system-wide basis, making it practically impossible to provide cohesive end-to-end fault tolerance in support of scientific applications. As an example, consider faults such as communication link failures that can be seen by a network library but are not directly visible to the job scheduler, or consider faults related to node failures that can be detected by system monitoring software but are not inherently visible to the resource manager. If information about such faults could be shared by the network libraries or monitoring software, then other system software, such as a resource manager or job scheduler, could ensure that failed nodes or failed network links were excluded from further job allocations and that further diagnosis could be performed. As a founding member and one of the lead developers of the Open MPI project, our efforts over the course of this project have been focused on making Open MPI more robust to failures by supporting various fault tolerance techniques, and using fault information exchange and coordination between MPI and the HPC system software stack from the application, numeric libraries, and programming language runtime to other common system components such as jobs schedulers, resource managers, and monitoring tools.

97 MATHEMATICS AND COMPUTING↗

A strainmeter array as the fulcrum of novel observatory sites along the Alto Tiberina Near Fault Observatory

Fault slip is a complex natural phenomenon involving multiple spatiotemporal scales from seconds to days to weeks. To understand the physical and chemical processes responsible for the full fault slip spectrum, a multidisciplinary approach is highly recommended. The Near Fault Observatories (NFOs) aim at providing high-precision and spatiotemporally dense multidisciplinary near-fault data, enabling the generation of new original observations and innovative scientific products. The Alto Tiberina Near Fault Observatory is a permanent monitoring infrastructure established around the Alto Tiberina fault (ATF), a 60 km long low-angle normal fault (mean dip 20°), located along a sector of the Northern Apennines (central Italy) undergoing an extension at a rate of about 3 mm yr –1 . The presence of repeating earthquakes on the ATF and a steep gradient in crustal velocities measured across the ATF by GNSS stations suggest large and deep (5–12 km) portions of the ATF undergoing aseismic creep. Both laboratory and theoretical studies indicate that any given patch of a fault can creep, nucleate slow earthquakes, and host large earthquakes, as also documented in nature for certain ruptures (e.g., Iquique in 2014, Tōhoku in 2011, and Parkfield in 2004). Nonetheless, how a fault patch switches from one mode of slip to another, as well as the interaction between creep, slow slip, and regular earthquakes, is still poorly documented by near-field observation. With the strainmeter array along the Alto Tiberina fault system (STAR) project, we build a series of six geophysical observatory sites consisting of 80–160 m deep vertical boreholes instrumented with strainmeters and seismometers as well as meteorological and GNSS antennas and additional seismometers at the surface. By covering the portions of the ATF that exhibits repeated earthquakes at shallow depth (above 4 km) with these new observatory sites, we aim to collect unique open-access data to answer fundamental questions about the relationship between creep, slow slip, dynamic earthquake rupture, and tectonic faulting.

58 GEOSCIENCES↗

What We Learned From Analyzing 18 Million Rows of Commercial Buildings’ HVAC Fault Data

To achieve ambitious decarbonization goals it is critical that buildings operate to their full potential. Commercial HVAC systems, however, experience a wide range of operational faults, adversely affecting energy consumption, occupant comfort, and maintenance costs. Analytical tools such as fault detection & diagnostics (FDD) software identify and help diagnose these types of sensing, mechanical, or control-related faults. While significant energy savings has been documented for FDD, along with limited-scale studies on technical capabilities, there is a lack of empirical data on faults being reported by FDD tools. With FDD deployment accelerating significantly over the past decade there is an opportunity to gather and analyze data on commercial HVAC operational problems at an unprecedented scale. Such data could address many questions such as: [a] What faults are most commonly reported?; and [b] How does fault reporting vary by time of year and other possible drivers? A recent study into FDD fault reporting amassed the largest U.S. dataset of commercial HVAC air-side fault records, drawn from multi-year monitoring across over 60,000 pieces of HVAC equipment. The results of this study provide granular data on fault reporting for over 90 unique fault types. In this paper we provide an overview of the research process and highlight key findings and lessons learned. This study presents an extraordinary level of detail on FDD fault reporting characteristics across many climate zones and building types. Armed with these new insights, commercial building industry stakeholders can make better informed decisions when designing, configuring, and operating commercial HVAC systems.

Crowe, Eliot↗

A propagation-based fault detection and discrimination method and the optimization of sensor deployment

Industrial processes can be affected by faults having a serious impact on operation when not promptly detected and diagnosed. Here in this paper, a propagation-based fault detection and discrimination(PFDD) method is proposed to develop a strategy for fault diagnosis while in the design phase of a system. The PFDD method constructs the system model using the Integrated System Fault Analysis(ISFA) technique. Based on the system model, the propagation of hardware and software faults are simulated qualitatively. Given the results of the simulation, the process by which a fault propagates can be characterized using the qualitative features of system variables including the deviation of the system variables from their expected values, the variation of the system variables over time, and the order in which each variable is influenced during the propagation of the fault. The strategy by which a fault can be detected and discriminated is defined using those features. The PFDD method supports the detection and discrimination of faults in both steady states and transient states. Based on the PFDD method, the optimization of sensor deployment in a system is discussed. A brute force algorithm is developed to examine the system’s capability at diagnosing faults and the cost of sensor deployment for all possible configurations of sensors. The optimal sensor deployment strategy can be derived accordingly. However, the brute force method is only applicable to small-scale systems due to its high computational cost. A genetic algorithm is used to optimize sensor deployment in large-scale systems. The PFDD and sensor deployment optimization methods are applied to the Experimental Breeder Reactor II (EBR-II) for verification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Unified Taxonomy for HVAC System Faults

Detecting and diagnosing HVAC faults is critical for maintaining building operation performance, reducing energy waste, and ensuring indoor comfort. An increasing deployment of commercial fault detection and diagnostics (FDD) software tools in commercial buildings in the past decade has significantly increased buildings’ operational reliability and reduced energy consumption. A massive amount of data has been generated by the FDD software tools. However, efficiently utilizing FDD data for ‘big data’ analytics, algorithm improvement, and other data-driven applications is challenging because the format and naming conventions of those data are very customized, unstructured, and hard to interpret. This paper presents the development of a unified taxonomy for HVAC faults. A taxonomy is an orderly classification of HVAC faults according to their characteristics and causal relations. The taxonomy includes fault categorization, physical hierarchy, fault library, relation model, and naming/tagging scheme. The taxonomy employs both a physical hierarchy of HVAC equipment and a cause-effect relationship model to reveal the root causes of faults in HVAC systems. A structured and standardized vocabulary library is developed to increase data representability and interpretability. The developed fault taxonomy can be used for HVAC system ‘big data’ analytics such as HVAC system fault prevalence analysis or the development of an HVAC FDD software standard. A common type of HVAC equipment-packaged rooftop unit (RTU) is used as an example to demonstrate the application of the developed fault taxonomy. Two RTU FDD software tools are used to show that after mapping FDD data according to the taxonomy, the meta-analysis of the multiple FDD reports is possible and efficient.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

A quantitative risk assessment framework for fault reactivation in underground hydrogen storage: Coupled simulation and deep learning approach

Underground hydrogen storage (UHS) is emerging as a critical solution for large-scale energy storage. However, like all subsurface fluid injection activities, UHS poses the risk of injection-induced fault reactivation. Accurate risk assessment is essential to ensuring the safety and efficiency of UHS operations. This study presents the development of deep-learning surrogate models for fault reactivation prediction in UHS, trained on a comprehensive database of fully coupled fluid flow-geomechanics simulations. Our findings reveal that analytical models often yield unreliable estimates, with errors up to 54% in the allowable injection pressure, potentially leading to a 40% reduction in UHS operational capacity. The developed surrogate models were incorporated into a quantitative risk assessment (QRA) framework, enabling probabilistic evaluation of fault reactivation risk while accounting for uncertainties in the input variables. Site-specific features, such as horizontal stress gradients, fault’s dip and strike angles, and operational parameters like bottom-hole injection pressure and well-fault distance, were identified as the primary drivers of fault reactivation across various stress regimes. Whereas other hydraulic, geological, and poroelastic reservoir properties were found to have a secondary impact. Notably, we observed that the risk of fault reactivation for a critically oriented fault with a static friction coefficient greater than 0.55 remains below 10% in a normal faulting stress regime. However, the risk significantly increases as the stress regime transitions from normal to strike-slip and ultimately to reverse faulting conditions. These findings underscore the importance of rigorous site characterization and comprehensive QRA evaluations to optimize UHS performance and minimize geomechanical risks.

25 ENERGY STORAGE↗

3-D Modeling of Induced Seismicity Along Multiple Faults: Magnitude, Rate, and Location in a Poroelasticity System

Understanding of the potential to injection–induced seismicity along faults requires the response of fault zone system to spatiotemporal perturbations in pore pressure and stress. In this study, three–dimensional (3–D) model system consisting of the caprock, reservoir, and basement is intersected by vertical strike–slip faults. We examine the full poroelastic behavior of the formation and perform the mechanical analysis along each fault zone using the Coulomb stress change. The magnitude, rate, and location of potential earthquakes are predicted using the spatial distribution of stresses and pore pressure over time. Rapid diffusion of pore pressure into conductive faults initiates failure, but the majority of induced seismicity occurs at deep fault zones due to poroelastic stabilization near the injection interval. Less permeable faults can be destabilized by either delayed pore pressure diffusion or poroelastic stressing. A two–dimensional (2–D) horizontal model, representing the interface between the reservoir and the basement, limits diffusion of pore pressure and deformation of the formation in the vertical direction that may overestimate or underestimate the potential of earthquakes along the fault. Lastly, our numerical results suggest that the 3–D modeling of faulting system including poroelastic coupling can reduce the uncertainty in the seismic hazard prediction by considering the hydraulic and mechanical interaction between faults and bounding formations.

3‐D modeling↗

Precursory Off-Fault Deformation in Restraining and Releasing Step Overs: Insights From Discrete Element Method Models

Accelerating geophysical activity is detected preceding some, but not all, large earthquakes. This observation may indicate that no precursors occur before some earthquakes, or that the instrumentation lacks the required sensitivity. Here, to aid crustal monitoring efforts, we use discrete element method models to identify the locations and styles of deformation that may provide useful information about approaching fault reactivation. We model the reactivation of two healed rough faults in a variety of step over configurations, embedded in a host rock with varying amounts of damage subject to shear velocity loading parallel to the faults. Both the fault geometry and ratio of fault to host rock strength control the amount of off-fault deformation. Consistent with field observations, models with larger steps and more preexisting host rock damage produce higher amounts of off-fault deformation. We assess the size of the continuous regions of high velocities and strains to compare the value of the precursory information of each velocity and strain component. Comparing the three components of the velocity vector suggests that the fault-parallel velocity produces the largest and most temporally continuous regions of elevated velocity. The size of these regions increases toward failure, indicating the usefulness of tracking this component. Comparing the volumetric and shear components of the three-dimensional strain tensor suggests that during most of the interseismic period, the shear strain provides more information about approaching fault slip than the volumetric strain. However, in the days and months preceding fault reactivation, both the shear and volumetric strains provide similarly valuable information.

58 GEOSCIENCES↗

Accelerating cavity fault prediction using deep learning at Jefferson Laboratory

Abstract Accelerating cavities are an integral part of the continuous electron beam accelerator facility (CEBAF) at Jefferson Laboratory. When any of the over 400 cavities in CEBAF experiences a fault, it disrupts beam delivery to experimental user halls. In this study, we propose the use of a deep learning model to predict slowly developing cavity faults. By utilizing pre-fault signals, we train a long short-term memory-convolutional neural network binary classifier to distinguish between radio-frequency (RF) signals during normal operation and RF signals indicative of impending faults. We optimize the model by adjusting the fault confidence threshold and implementing a multiple consecutive window criterion to identify fault events, ensuring a low false positive rate. Results obtained from analysis of a real dataset collected from the accelerating cavities simulating a deployed scenario demonstrate the model’s ability to identify normal signals with 99.99% accuracy and correctly predict 80% of slowly developing faults. Notably, these achievements were achieved in the context of a highly imbalanced dataset, and fault predictions were made several hundred milliseconds before the onset of the fault. Anticipating faults enables preemptive measures to improve operational efficiency by preventing or mitigating their occurrence.

43 PARTICLE ACCELERATORS↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Characteristics and selection of near-fault simulated earthquake ground motions for nonlinear analysis of buildings

Earthquake-induced ground shaking near rupturing faults is highly sensitive to the rupture characteristics, seismic wave propagation patterns and site conditions, and field recordings of near-fault shaking are relatively sparse. These challenges complicate the assessment of the seismic performance of near-fault structures. A common approach to representing near-fault ground motion in engineering analysis is to explicitly consider and select records with strong directivity pulses (pulse records). We use three-dimensional high-resolution physics-based earthquake simulations to test this approach in the context of scenario-based ground motion record selection, and to study the important characteristics of near-fault ground shaking. We highlight the deficiencies associated with classifying near-fault simulated records as “pulse” or “non-pulse,” based on the presence of a single dominating pulse in the velocity time history. We show that this approach is inadequate for characterizing near-fault shaking on soft soils which can be dominated by both forward rupture directivity and basin amplification effects. We conduct ground motion selection experiments for the analysis of near-fault structures with and without explicit classification of the pulse features in the records, and evaluate the bias in the predicted structural demands. We find that the maximum interstory drift demands on building structures imposed by unscaled site-specific simulated ground motion records selected based on relevant spectral shape features are not sensitive to the classification of records as pulse/non-pulse. Therefore, with regard to predicting the maximum interstory drifts in near-fault buildings, we do not find justification for the binary pulse classification of near-fault records.

42 ENGINEERING↗

Common Faults and Their Prioritization in Small Commercial Buildings

This study documents faults that are commonly found in small commercial buildings based on a literature review and discussions with building commissioning experts. It also provides a list of prioritized faults based on an estimation of the prevalence, energy impact, and financial impact of each fault. A total of 39 faults were analyzed for this paper and classified by location, stage, and type. The technical complexity of detecting each type of fault based on typically available information was evaluated for each fault. The annual energy impact (AEI) and annual financial impact (AFI) of each fault were estimated based on available information. Based on these estimates, 20 top priority faults were identified. Seven out of the 20 top priority faults occur in vapor compression systems such as air-conditioning, heat pump, and refrigeration equipment. Nonstandard charging, condenser, and evaporator fouling are the most important faults for this type of equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗