At least 217 records · Page 12

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Utility Perspective on Protection Challenges with High IBR Penetration [Slides]

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Identifying geological structures through microseismic cluster and burst analyses complementing active seismic interpretation

At the Decatur carbon capture and storage site (IL, USA) CO 2 has been injected from 2011–2014 and from 2017 to present near the base of the Lower Mt. Simon Sandstone saline reservoir, resulting in microseismicity. Microseismicity is mainly located in the basement and distributed in distinct spatial clusters. The lack of significant impedance contrasts within the basement makes the interpretation of active-source seismic reflection data challenging, however, recent reprocessing allowed to resolve faults above and at the top of the basement. These faults generally do not coincide with the location of microseismic events and their continuation to the general depth of the seismic events cannot be assumed. This paper shows how the interpretation of the microseismicity can complement structural interpretations of active-source seismic reflection data. In particular, we analyze clusters and bursts (abrupt increases) of microseismicity, identify unresolved, smaller-scale weaknesses and extract statistical parameters. These parameters allow comparisons with the interpreted faults, and with fracture sets intercepted by boreholes. During injection at the Decatur site, the injection pressure was kept far below fracture pressure, nevertheless, seismic events were induced and spread far beyond the expected extent of the CO 2 plume. We argue that local stress transfers related to the CO 2 injection reactivated pre-existing fractures within the critically stressed basement. Finally, we conducted a slip tendency analysis for faults interpreted from active seismic, selected cluster, bursts and nodal planes from focal mechanisms to determine if the interpreted structures are optimally oriented with respect to the stress regime. Our results suggest that the orientation of fractures close to the injection well, generally shows slight deviations from the optimal orientation for slip. This might indicate either slight local deviations of the maximum horizontal stress azimuth from the average direction used in the analysis, or the lack of optimally oriented fractures at this location.

58 GEOSCIENCES↗

A spatial-statistical investigation of surface expressions associated with cyclic steaming in the Midway-Sunset Oil Field, California

In the Midway Sunset Oil Field in Central California, operators inject steam into the shallow diatomite formation to enhance heavy oil recovery through imbibition, wettability alteration, and viscosity reduction, among other mechanisms. The injected steam, however, does not always remain in the reservoir or return through the wells. In two zones in the study area, the steam comes out at the surface, creating sinkholes, seeps, and steam outlets. These phenomena, called “surface expressions,” pose safety and environmental hazards. Even though these surface expressions are a widespread problem in Central California, they are not well documented and understood. Possible causes of the surface expressions include: high injection pressure, structurally controlled flow patterns, leakage of steam through old improperly abandoned wells, high injection volumes, or flow along naturally occurring faults, among other possible factors. This work examines attributes of the zones with surface expressions in order to determine factors that may contribute to their occurrence. Spatial statistical analysis using logistic regression, random forests, and classification trees is used to explore the relationship between the surface expressions and geological and production-related attributes. The results point to a significant spatial correlation between the surface expressions and two predictors: concentration of plugged wells and geologic seal thickness. The results guide follow-up studies to further investigate the role of well abandonment and seal thickness in the occurrence of surface expressions.

02 PETROLEUM↗

A general software reliability process simulation technique

The structure and rationale of the generalized software reliability process, together with the design and implementation of a computer program that simulates this process are described. Given assumed parameters of a particular project, the users of this program are able to generate simulated status timelines of work products, numbers of injected anomalies, and the progress of testing, fault isolation, repair, validation, and retest. Such timelines are useful in comparison with actual timeline data, for validating the project input parameters, and for providing data for researchers in reliability prediction modeling.

Tausworthe, Robert C.↗

Shallow Aseismic Slip in the Delaware Basin Determined by Sentinel-1 InSAR

The Delaware Basin, Texas is currently a hot-spot of induced seismicity and ground deformation due to fluid extraction and injection associated with horizontal drilling techniques; however, the driving mechanism behind the seismicity and deformation remains under debate. Here, using vertical and east-west horizontal surface deformation measurements derived from Sentinel-1 interferometric synthetic aperture radar (InSAR), we show that the subsurface responds differently to oil and gas activity in the northern and southeastern portions of the basin. In the north, where there is little seismicity, deformation patterns display long-wavelengths and equidimensional patterns. In contrast, the southeast region hosts most of the seismicity and displays spatial deformation patterns with narrow linear features that strike parallel to the maximum principal horizontal stress and to trends in seismicity, suggesting movement along normal faults. We model a linear deformation feature using edge dislocations and show that the InSAR observations can be reproduced by slip on normal faults contained within the Delaware Mountain Group (DMG), the formation that hosts local wastewater injection and the majority of earthquakes. Our model consists of three parallel, high-angle normal faults, with two dipping toward one another in a graben structure. Slip magnitudes reach up to 25 cm and are spatially correlated with injection wells. Measured seismicity can only explain ~2% of the fault motion predicted by our fault model, suggesting that slip leading to the deformation is predominantly aseismic. We conclude that seismic and aseismic fault motion in the southeastern Delaware Basin is likely driven by wastewater injection near critically-stressed normal faults within the DMG.

58 GEOSCIENCES↗

Two-Phase Flow Mechanisms Controlling CO2 Intrusion into Shaly Caprock

Abstract Geologic carbon storage in deep saline aquifers has emerged as a promising technique to mitigate climate change. CO 2 is buoyant at the storage conditions and tends to float over the resident brine jeopardizing long-term containment goals. Therefore, the caprock sealing capacity is of great importance and requires detailed assessment. We perform supercritical CO 2 injection experiments on shaly caprock samples (intact caprock and fault zone) under representative subsurface conditions. We numerically simulate the experiments, satisfactorily reproducing the observed evolution trends. Simulation results highlight the dynamics of CO 2 flow through the specimens with implications to CO 2 leakage risk assessment in field practices. The large injection-induced overpressure drives CO 2 in free phase into the caprock specimens. However, the relative permeability increase following the drainage path is insufficient to provoke an effective advancement of the free-phase CO 2 . As a result, the bulk CO 2 front becomes almost immobile. This implies that the caprock sealing capacity is unlikely to be compromised by a rapid capillary breakthrough and the injected CO 2 does not penetrate deep into the caprock. In the long term, the intrinsically slow molecular diffusion appears to dominate the migration of CO 2 dissolved into brine. Nonetheless, the inherently tortuous nature of shaly caprock further holds back the diffusive flow, favoring safe underground storage of CO 2 over geological time scales.

58 GEOSCIENCES↗

NASA systems autonomy demonstration project: Advanced automation demonstration of Space Station Freedom thermal control system

The NASA Systems Autonomy Demonstration Project (SADP) was initiated in response to Congressional interest in Space station automation technology demonstration. The SADP is a joint cooperative effort between Ames Research Center (ARC) and Johnson Space Center (JSC) to demonstrate advanced automation technology feasibility using the Space Station Freedom Thermal Control System (TCS) test bed. A model-based expert system and its operator interface were developed by knowledge engineers, AI researchers, and human factors researchers at ARC working with the domain experts and system integration engineers at JSC. Its target application is a prototype heat acquisition and transport subsystem of a space station TCS. The demonstration is scheduled to be conducted at JSC in August, 1989. The demonstration will consist of a detailed test of the ability of the Thermal Expert System to conduct real time normal operations (start-up, set point changes, shut-down) and to conduct fault detection, isolation, and recovery (FDIR) on the test article. The FDIR will be conducted by injecting ten component level failures that will manifest themselves as seven different system level faults. Here, the SADP goals, are described as well as the Thermal Control Expert System that has been developed for demonstration.

Dominick, Jeffrey↗

Identification of Faults Susceptible to Induced Seismicity (Final Report)

Central to the work documented in this report is the capability of geocellular models to represent the geologic conceptual model updated with fault identification from machine learning and joint inversion modeling of microseismic data measured and recorded as a consequence of CO 2 injection at a field demonstration site: the Illinois Basin - Decatur Project (IBDP). This work required seven unique geocellular models with 100s of simulated variations to gain a very high degree of confidence in the identification of geologic features present that contributed to induced microseismicity at IBDP. All forward modeling: pressure modeling, stress modeling, and seismic modeling used the same geologic conceptual model and representations of that model at different scales. The pressure modeling and poroelastic modeling created “snapshots” of pore pressure and stress field changes at different times during CO 2 injection, in which microseismic events were clustered (in time). These pressure and stress snapshots, within the framework and architecture of the geologic conceptual model via the geocellular model, informed the single fault and fault network models to ascertain the likelihood of fault movement (seismic or aseismic). The outcomes of the pressure, stress, and fault/fault network (seismic) modeling confirmed that the faults in the geologic conceptual model in Task 2 were likely the source of microseismic events measured at IBDP and acted as conduits for pressure to be transmitted from the injection interval into the Precambrian crystalline basement rock. This closely coordinated and integrated unique modeling approach was conducted to prove the viability of our proposed workflow 1) to better resolve crystalline basement faults, 2) detect subseismic faults that could be activated by injection, 3) increase the certainty in fault detection and their susceptibility to release seismic energy, and 4) understand transmission of pressure vertically from the well to the underlying fractured crystalline basement. The proposed methodology was effective in guiding an iterative process of calibrating forward modeling results based on similar geocellular models while honoring the geologic conceptual model (i.e., characterization data and knowledge of regional geology); this led to higher level of certainty in the identification of fault/faults zones to control seismicity and transmission of pressure to the regions of recorded and located injection induced seismicity.

58 GEOSCIENCES↗

Constraining induced seismicity hazard on the Neck of the Desert fault for the proposed Iron Mountain, Utah carbon sequestration project

As significantly more focus is placed on carbon sequestration as a means to help mitigate the progression of climate change, the need to adequately characterize an injection target for its induced seismicity potential becomes more apparent. In the Iron Mountain project in Southern Utah, a single fault is identified in the Neck of the Desert near Iron Mountain. The dip of the fault is unknown, and the geomechanical stability of the fault (i.e., distribution of Coulomb failure functions (CFFs)) is highly dependent upon the dip. For some dips, such as 15 degrees, the hazard from injection is low. For other dips, such as 75 degrees, the hazard is high. Another key consideration is the depth of penetration of the fault. Should the fault not penetrate the stress and pressure perturbed region from injection, it will not be induced to fail. Thus, understanding the dip and the depth of penetration of the fault will greatly improve our understanding of the likelihood of inducing an earthquake.

58 GEOSCIENCES↗

Challenge Solutions for a Significant Water Cut Reduction History Match on Heavy Oil Polymer EOR

Milne Point Field is conducting the first-ever active polymer flood pilot program designed to enhance oil recovery (EOR) of heavy oils on the Alaska North Slope (ANS). The experimental field program consists of two pairs of horizontal injection and production wells deployed in an isolated fault block in the Schrader Bluff reservoir. The EOR method combines polymer flooding and low salinity water flooding to improve recovery. Prior average water cut reduction in polymer EOR fields ordinarily ranges between 10% to 15% for most light oil and heavy oil reservoirs. When comparing other field applications, the long-lasting (24 months) and much lower water cut poses a challenge for numerical history matching when applying typical simulation methods. This abstract discusses two practical new approaches used for history matching of the long-lasting ultralow water cut. These new applications include 1) multiple relative permeability curves with J-function incorporation with low endpoints of relative permeability of water (Krw). This approach integrated the permeability differential adjustment in the geometries of horizontal and vertical directions based on geological review. 2) A specific permeability channel strips along with the horizontal or vertical planar assumption. The current history matching results indicate success in achieving an excellent agreement with the field observed low water-cut.

Namie, S.↗

First Ever Polymer Flood Field Pilot to Enhance the Recovery of Heavy Oils on Alaska North Slope – Producer Responses and Operational Lessons Learned

The US Department of Energy and Hilcorp Alaska, LLC are jointly cosponsoring a field pilot project entitled “First Ever Field Pilot on Alaska’s North Slope to Validate the Use of Polymer Floods for Heavy Oil Enhanced Oil Recovery (EOR).” The objective of this pilot is to perform a field experiment to validate the use of an advanced polymer flooding technology to unlock the vast heavy oil resources on Alaska North Slope (ANS). Two pairs of horizontal injection and production wells have been deployed in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field to conduct a polymer flood pilot which was designed to acquire field performance data to optimize polymer flood design in the Schrader Bluff heavy oil reservoirs on ANS. Hydrolyzed polyacrylamide (HPAM) polymer injection started on August 28, 2018 using a custom made polymer mixing and pumping unit. Polymer solution properties such as concentration, viscosity, and filter ratio, have been closely monitored and adjusted as necessary. Operational procedures have been improved to ensure adequate injectivity and polymer propagation through the formation. Oil and water production is tested frequently to monitor water cut performance, and produced water is sampled and analyzed for polymer content. Tracers were pumped pre and post polymer injection startup to compare polymer flood breakthrough timing and sweep efficiency. Polymer injectivity of the horizontal wells drilled in the Schrader Bluff NB sand is found to be sufficient to replace the reservoir production voidage although there were some declines as high viscosity polymer swept the near wellbore region. Production data show significant reduction in water cut and the oil production rate has stabilized. No polymer production has been confirmed from the two horizontal producers after 22 months of polymer injection into the two supporting horizontal injectors. Tracer data show very low sweep efficiencies with waterflood alone, whereas significant improvement has been achieved with polymer flood. Many operational lessons have been learned and improvements have been made regarding polymer mixing, pumping, and onsite quality control, particularly in a challenging Arctic environment. Adequate polymer injection rate can be achieved with diligent monitoring and quality assurance of the properties of the injected polymer solution.

Ning, Samson↗

Numerical assessment of fault impact on caprock seals during CO 2 sequestration

Coupled fluid-flow and geomechanical analysis of caprock integrity has gained a lot of attention among scientists and researchers investigating the long-term performance of geologic carbon storage systems. Reactivation of pre-existing fractures within the caprock or re-opening of faults can create permeable pathways which can influence the seal integrity. Stability of the caprock during and after injection of super-critical CO 2 , and the impact of pre-existing fractures in the presence or absence of one or multiple faults have been investigated in this study. The impact of the wellbore orientation and the injection rate are among other key factors in understanding the structural trapping mechanisms within such geological formations. In this study, we numerically investigated the impact of each of these factors. This study revealed the interplay between joints and faults and how different leakage pathways are formed and under which scenario they play a dominant role in terms of CO 2 leakage. Finally, this study also highlights the role of one versus multiple faults in the domain and the importance of the fault hydrological property in forming leakage pathway.

58 GEOSCIENCES↗

Modeling, Detection, and Disambiguation of Sensor Faults for Aerospace Applications

Sensor faults continue to be a major hurdle for systems health management to reach its full potential. At the same time, few recorded instances of sensor faults exist. It is equally difficult to seed particular sensor faults. Therefore, research is underway to better understand the different fault modes seen in sensors and to model the faults. The fault models can then be used in simulated sensor fault scenarios to ensure that algorithms can distinguish between sensor faults and system faults. The paper illustrates the work with data collected from an electro-mechanical actuator in an aerospace setting, equipped with temperature, vibration, current, and position sensors. The most common sensor faults, such as bias, drift, scaling, and dropout were simulated and injected into the experimental data, with the goal of making these simulations as realistic as feasible. A neural network based classifier was then created and tested on both experimental data and the more challenging randomized data sequences. Additional studies were also conducted to determine sensitivity of detection and disambiguation efficacy to severity of fault conditions.

Balaban, Edward↗

A workflow to assess the efficacy of brine extraction for managing injection-induced seismicity potential using data from a CO 2 injection site near Decatur, Illinois

Injection of CO 2 for storage in a geologic formation increases pore pressure and alters in situ stresses. Depending on the orientation of any existing fault and fracture planes, such as critically stressed planes, this stress alteration will modify normal stresses acting on planes and could result in frictional sliding and release stored energy in the form of seismicity. Brine extraction (BE) is a technique that can be applied prior to, or during, CO 2 injection to reduce pore pressure for increasing storage capacity and, potentially, for reducing the likelihood of frictional sliding. Here a workflow is described to assess the efficacy of BE for mitigating frictional sliding (i.e., seismicity) during injection and entails: site characterization, stress calculations and failure assessment, static and dynamic modeling, and BE operational planning. Site characterization describes the stress field used to calculate the Coulomb Failure Function (CFF) that constrains allowable pore pressure changes and injection rates in the numerical simulation of CO 2 injection scenarios. The inclusion of BE in the workflow allows for determination of the potential need for pressure reduction, and evaluation of the effectiveness of this operation. Example application of the workflow using an injection field dataset near Decatur, IL, provides insight on fracture planes and stresses at the site, formation properties and the impact of variable CO 2 injection-rate targets on whether BE plans are required. The study workflow indicates that BE could enhance CO 2 injection rate by 39% and correspondingly reduce the potential for injection-induced seismicity as indicated by a reduction in CFF.

58 GEOSCIENCES↗

High Impedance Fault Detection Through Quasi-Static State Estimation: A Parameter Error Modeling Approach

This paper presents a model for detecting high impedance faults using parameter error modeling and a two step per-phase weighted-least squares state estimation process. The proposed scheme leverages the use of Phasor Measurement Units and synthetic measurements to identify per-phase power flow and injection measurements which indicate a parameter error through ?2 Hypothesis Testing applied to the composed measurement error. Although current and voltage waveforms are commonly analyzed for high-impedance fault detection, wide area power flow and injection measurements, which are already inherent to the state estimation process, also show promise for real-world high-impedance fault detection applications. The error distributions after detection share the measurement function error spread observed in proven parameter error diagnostics and can be applied to high-impedance fault identification. Further, this error spread across measurement functions related to the fault will be clearly discerned from measurement error. Case studies are performed on the IEEE 33-Bus Distribution System along with the proposed model in Simulink.

Cooper, Austin↗