Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “evaporation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Evaporative coolers and wildfire smoke exposure: a climate justice issue in hot, dry regions

Low-income families in dry regions, including in the Southwestern United States, frequently cool their homes with evaporative ("swamp") coolers (ECs). While inexpensive and energy efficient compared to central air conditioners, ECs pull unfiltered outdoor air into the home, creating a health hazard to occupants when wildfire smoke and heat events coincide. A community-engaged research project to reduce wildfire smoke in homes was conducted in California's San Joaquin Valley in homes of Spanish-speaking agricultural workers. A total of 88 study participants with ECs were asked about their level of satisfaction with their EC and their willingness to pay for air filtration. About 47% of participants reported dissatisfaction with their EC, with the most frequently reported reason being that it brings in dust and air pollution. Participants were highly satisfied with air cleaners and air filters that were offered to them free-of-charge. However, a willingness to pay analysis showed that air filtration solutions would not be adopted without significant subsidies; furthermore, air filtration would be an ongoing cost to participants due to the need to regularly replace filters. Short-term filtration solutions for EC users are feasible to implement and may reduce smoke exposure during wildfire events. Such solutions would need to be offered at low-or no-cost to reduce barriers to adoption. Longer term solutions include prioritizing homes with ECs in wildfire smoke exposed regions for replacement with air cooling technologies that provide clean air. Because ECs are disproportionately in low-income homes, addressing smoke intrusion through these devices is an environmental justice issue.

Solomon, Gina M↗

CONDENSATION-EVAPORATION MODELING OF DRIFT FROM A MECHANICAL COOLING TOWER

Numerical studyfor investigatingthe phase change behavior of a drift from a mechanical draft cooling tower is presented. A k-ε turbulence model, discrete phase model, species transport equations, and a heat-mass exchange model are solved simultaneouslyto capture the heat and mass transfer effects of a drift condensing and evaporatingeffects. The simulation result is compared to an available real scale test data and its limitation is also discussed. A parametric study is carried out by varying the ambient dry bulb temperature, ambient relative humidity, wind speed, liquid droplet diameter, and the drift amount. It is found that by combining the evaporation and condensation models, a drift phase change phenomena is accurately depicted. A parametric study reveals that wind speed impact is affected by the ambient temperature and the number of liquid droplets and their size play a critical role in the phase change phen

Han, Kai↗

A Numerical Analysis of The Pool Boiling Process in Flooded Evaporators Using Different Refrigerants

The pool boiling process can be observed in several energy conversion processes including commercial and industrial refrigeration, industrial air-cooling operations, and power generation. The process becomes more involved when pool boiling in a tube bundle is considered. In the current study, a numerical model is developed to predict the key performance parameters of a flooded evaporator while considering a range of working fluids. A kettle reboiler configuration was considered, and a performance model was developed to account for boiling on individual tubes, merging of vapor bubbles, and movement under gravity. A volume of fluid (VOF) model was used to deal with the different phases in the simulation. Various fluids were considered in this study including HFE-7000, HFE-7300, and water. The trajectories of the bubbles were tracked, and the resulting information has been summarized in physical measurable quantities.

Zhang, Mingkan↗

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of micro-fin tube geometry parameters on evaporator material savings

A Performance Evaluation Criteria (PEC) analysis is presented that explores the influence of the micro-fin tube geometry on the required material volume. The analysis was done using a local flow boiling model, which can quantify the effect of fin parameters and the tube diameter. The PEC was done while requiring that the compared surfaces satisfy the same heat duty and pressure drop. The following tube parameters and ranges were explored: tube diameter (3 mm ≤ D o ≤ 6 mm), fin base thickness (0.12 mm ≤ t bf ≤ 0.29 mm), helix angle (6° ≤ α ≤ 30°), fin apex angle (11° ≤ β ≤ 22°), total number of fins (43 ≤ n f ≤ 70), and the fin height (0.11 mm ≤ e ≤ 0.3 mm). The tube that provided the smallest material requirements within the examined parameter ranges had: D o = 3 mm, t bf = 0.12 mm, α = 6°, β = 11°, n f = 43, and e = 0.3 mm. In general, small D o and t bf and large n f and e provided the best performance and work to minimize the required material volume to provide a given heat duty and pressure drop. The helix and the fin-tip apex angles were found to have very little influence on the performance for the examined range of parameters and angles associated with the lowest production cost should be chosen.

Evaporation↗

Desalination Multi-Effect Evaporator Models in Support of Integrated Energy Systems

The purpose of this work is to contribute to the Integrated Energy Systems (IES) modeling efforts from the Department of Energy with Idaho National Laboratory. The DOE is working on a plug-and-play set of models in an open-source repository called HYBRID that can be used to improve IES modeling capabilities.

99 GENERAL AND MISCELLANEOUS↗

The evaporation of black holes in supergravity

In supergravity, charged rotating black holes are generically driven towards becoming extremal and supersymmetric through the emission of Hawking radiation. Eventually, as the black hole approaches the BPS bound and is close to becoming supersymmetric, quantum gravity corrections become critical to describing the emission of Hawking radiation, making the QFT in curved spacetime approximation inaccurate. In this paper, we compute how such quantum gravity corrections affect the spectrum of Hawking radiation for black holes in $\mathcal{N}$ = 2 supergravity in flatspace. We show that due to such corrections, the spectrum of emitted Hawking radiation for both spin-0 and spin-1/2 particles deviates drastically at low temperatures from the naively expected black-body spectrum. Rather remarkably, the spectrum exhibits a discrete emission line from direct transitions from near-BPS to BPS states, providing the first controlled example where the discreteness of the black hole energies is visible in the emitted Hawking radiation. Similar quantum gravity effects drastically modify the absorption cross-section: BPS black holes are transparent to certain frequencies, while near-BPS black holes appear much larger than the semi-classical prediction.

AdS-CFT Correspondence↗

Islands in non-minimal dilaton gravity: exploring effective theories for black hole evaporation

We start from (3 + 1)-dimensional Einstein gravity with minimally coupled massless scalar matter, through spherical dimensional reduction, the matter theory is non-minimally coupled with the dilaton in (1 + 1)-dimensions. Despite its simplicity, constructing a self-consistent one-loop effective theory for this model remains a challenge, partially due to a Weyl-invariant ambiguity in the effective action. With a universal splitting property for the one-loop action, the ambiguity can be identified with the state-dependent part of the covariant quantum stress tensor. By introducing on-shell equivalent auxiliary fields to construct minimal candidates of Weyl-invariant terms, we derive a one-parameter family of one-loop actions with unique, regular, and physical stress tensors corresponding to the Boulware, Hartle-Hawking and Unruh states. We further study the back-reacted geometry and the corresponding quantum extremal islands that were inaccessible without a consistent one-loop theory. Along the way, we elaborate on the implications of our construction for the non-minimal dilaton gravity model.

2D Gravity↗