Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “equivalent circuits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Lightweight multiple output converter development

A high frequency, multiple output power conditioner was developed and breadboarded using an eight-stage capacitor diode voltage multiplier to provide +1200 Vdc, and a three-stage for -350 Vdc. In addition, two rectifier bridges were capacitively coupled to the eight-stage multiplier to obtain 0.5 and 0.65 a dc constant current outputs referenced to +1200 Vdc. Total power was 120 watts, with an overall efficiency of 85 percent at the 80 kHz operating frequency. All outputs were regulated to three percent or better, with complete short circuit protection. The power conditioner component weight and efficiency were compared to the equivalent four outputs of the 10 kHz conditioner for the 8 cm ion engine. Weight reduction for the four outputs was 557 grams; extrapolated in the same ratio to all nine outputs, it would be 1100 to 1400 grams.

Kisch, J. J.↗

The probability of a correct output from a combinational circuit

The paper discusses two methods to evaluate the signal reliability of the output of logical circuits. It is known that faults present in a circuit will not always cause the output of the circuit to be incorrect. The first method evaluates the contribution of each fault to the reliability of the circuit and requires the enumeration of the behavior of each fault in the entire fault set. The use of McCluskey and Clegg's characterization of faulty networks by evaluating the functional equivalence classes of the network is a way to reduce the amount of computation involved. The second method uses a probabilistic model of logical circuits and consists of straightforward operations which can easily be automated. The method also yields the signal reliability and has the capability of very easily specifying the individual fault probabilities of all the circuit lines independently.

Ogus, R. C.↗

Radiation damage in MOS integrated circuits, Part 1

Complementary and p-channel MOS integrated circuits made by four commercial manufacturers were investigated for sensitivity to radiation environment. The circuits were irradiated with 1.5 MeV electrons. The results are given for electrons and for the Co-60 gamma radiation equivalent. The data are presented in terms of shifts in the threshold potentials and changes in transconductances and leakages. Gate biases of -10V, +10V and zero volts were applied to individual MOS units during irradiation. It was found that, in most of circuits of complementary MOS technologies, noticable changes due to radiation appear first as increased leakage in n-channel MOSFETs somewhat before a total integrated dose 10 to the 12th power electrons/sg cm is reached. The inability of p-channel MOSFETs to turn on sets in at about 10 to the 13th power electrons/sq cm. Of the circuits tested, an RCA A-series circuit was the most radiation resistant sample.

Danchenko, V.↗

Electrodynamic tether

Electrodynamic tethers hold promise for a variety of space applications. Electrodynamic tethers depend upon the interactions between a moving insulated conductor and the Earth's magnetic field. An electric field is generated along the tether as in a conductor moving in the magnetic field of a generator. If the circuit is closed to the ambient space plasma via a plasma gun or other equivalent device, a current is enabled to flow in the tether, and electric power is generated at the expense of orbital mechanical energy. The net effect is a decrease in the altitude of the orbiting tethered system. The situation can be reversed by driving current against the electric field via an external power supply such as a photovoltaic array.

Patterson, Michael↗

A portable absorbed dose measuring instrument with gamma discrimination

The characteristics of an electronic instrument for measuring the radiation dose absorbed by tissues are presented. The detector is a sphere of tissue-equivalent plastic with a single wire located on a diameter of the sphere. The electronic circuits and method of operation of the detector are described. Advantages are the small size and easy portability plus ability to selectively measure neutron and gamma plus neutron events.

Quam, W. M.↗

Process Research on Polycrystalline Silicon Material (PROPSM)

Results of hydrogen-passivated polycrysalline silicon solar cell research are summarized. The short-circuit current of solar cells fabricated from large-grain cast polycrystalline silicon is nearly equivalent to that of single-crystal cells, which indicates long bulk minority-carrier diffusion length. Treatments with molecular hydrogen showed no effect on large-grain cast polycrystalline silicon solar cells.

Culik, J. S.↗

Active Electrical-Transient Damper

Active damping circuit functions similarly to passive damping circuit, but volume, weight, and cost do not increase as steeply with rated power as equivalent passive damper. Affords advantages of economy that increases with rated power.

Dolland, Carlisle R.↗

Solid-state switch increases switching speed

Solid state switch for commutating capacitors in an RC commutated network increases switching speed and extends the filtering or commutating frequency spectrum well into the kilocycle region. The switch is equivalent to the standard double- pole double-throw /DPDT/ relay and is driven from digital micrologic circuits.

Mc~gowan, G. F.↗

Dual-Resonator Kinetic-Inductance Detector for Distinction between Signal and 1/ƒ Frequency Noise

Astronomical kinetic inductance detectors (KIDs), similar to quantum information devices, experience performance-limiting noise from materials. In particular, 1/ƒ (frequency) noise arises from two-level system defects (TLSs) in the circuit dielectrics and material interfaces and can be a dominant noise mechanism. Here, we present a dual-resonator KID (DuRKID), which is designed for improved noise-equivalent power relative to standard 1/ƒ -noise-limited KIDs. In this study we present the DuRKID schematic, a fabricated example, our first measurement results, a theoretical model including 1/ƒ noise, and a system-noise model containing additional noise sources. The circuit consists of two superconducting resonators sharing an electrical capacitance bridge of four capacitors, each of which hosts TLSs. The device is intended to operate using hybridization of the modes, which causes TLSs to either couple to one mode or the other, depending upon which capacitor they reside in. In contrast, the signal will affect a resonator inductance and, due to mode hybridization, this causes correlated frequency changes in both modes. Therefore, one can better distinguish the photon signal from the TLS frequency noise. To achieve hybridization, a TiN inductor is current biased to allow tuning of one bare-resonator mode into degeneracy with the other. Measurements show that the resonator modes hybridize as expected. The inter-resonator coupling and unintentional coupling of the two resonators to transmission lines are also characterized in measurements. A quantum information-science model allows device-parameter extraction from experimental data and a 1/ƒ noise analysis with uncorrelated noise. A system-noise analysis of the DuRKID, with comparisons to standard KIDs, is performed with generation-recombination noise and amplifier noise. The study reveals that the DuRKID can exhibit a large performance advantage over TLS-limited KID detectors.

N Forouzani↗

Common source cascode amplifiers for integrating IR-FPA applications

Space based astronomical infrared measurements present stringent performance requirements on the infrared detector arrays and their associated readout circuitry. To evaluate the usefulness of commercial CMOS technology for astronomical readout applications a theoretical and experimental evaluation was performed on source follower and common-source cascode integrating amplifiers. Theoretical analysis indicates that for conditions where the input amplifier integration capacitance is limited by the detectors capacitance the input referred rms noise electrons of each amplifier should be equivalent. For conditions of input gate limited capacitance the source follower should provide lower noise. Measurements of test circuits containing both source follower and common source cascode circuits showed substantially lower input referred noise for the common-source cascode input circuits. Noise measurements yielded 4.8 input referred rms noise electrons for an 8.5 minute integration. The signal and noise gain of the common-source cascode amplifier appears to offer substantial advantages in acheiving predicted noise levels.

Woolaway, James T.↗

Develop real-time dosimetry concepts and instrumentation for long term missions

The development of a rugged portable instrument to evaluate dose and dose equivalent is described. A tissue-equivalent proportional counter simulating a 2 micrometer spherical tissue volume was operated satisfactorily for over a year. The basic elements of the electronic system were designed and tested. And finally, the most suitable mathematical technique for evaluating dose equivalent with a portable instrument was selected. Design and fabrication of a portable prototype, based on the previously tested circuits, is underway.

Braby, L. A.↗

Comments on SEE: Comparative Advantages and and Experimental Consequences

The Satellite Energy Exchange experiment measures the periodic, near-miss encounters between a sheppard satellite and a small test body (satellite) in approximately the same orbit about a primary. Several important experimental requirements have been chosen to enhance capabilities: (a) The satellite be flown in a sun-synchronous orbit at an altitude of about 1350 Km, (b) Passive temperature system stabilized by spacecraft axial rotation with sunshade baffles at the end of the spacecraft, (c) Test bodies with different material composition be available for experiments, (d) The containment spacecraft fly about the sheppard mass in a zero-g environment whereas the test bodies, experience average zero-g environment over an orbital period, (e) Primary attitude and station-keeping uses magnetic field alignment plus micro-Newton thrusters such as Field Emission Electric Propulsion, and (f) Very low power (nW) laser tracking systems minimize impulse delivered to test bodies. With the above conditions, SEE has the capabilities: (1) Long duration (several years life-time) flight experiment (2) Long-term, active (with historical time record), self-calibration of satellite mass distribution (capsule geodesy) over lifetime of the spacecraft. (3) Novel passive thermal stabilization systems designed to attain cryogenic temperatures around 78K. (4) Novel spacecraft stabilization systems. (5) Ability to measure G to 1 part in 10(exp 6-7) depending on ultimate duration of experiment. (6) Ability to place limits on both temporal and spacial variations on G. (7) Ability to set experimental limits on the Post Newtonian parameters (PPN) alpha(2) and zeta(2). (8) Ability to measure (or place limits on) the non Einsteinian eccentricity of the Earth-Sun system (and the parameter alpha(1)) for long duration flight. (9) Ability to measure Delta((dot)-G)/G to 1 part in 10(exp 12-13). The MiniSTEP, competes in a limited way with Project SEE. It is designed to improve the measurement of the equivalence principle by seven orders of magnitude using active, low temperature (1.8 K) cooling for SQUID based, differential superconducting circuits. The experiment consists of a small cylinder concentrically located within a larger cylinder at its null gravitational point. The satellite is operated in zero-g mode using four differential accelerometers consisting to two test bodies of different material composition. The SQUIDS are needed to measure test body motion to precisions of 10(exp -18) over a four orbit period. The entire satellite moves in a very precise zero-g mode since the accelerometers are rigidly attached to the satellite. This limits the experiment to an approximately six month due to limitations on helium storage used in cryogenic cooling and thrust control to maintain the zero-g operation.

Smalley, Larry L.↗

A prediction model for bipolar RAMs in a high energy ion/proton environment

A model has been developed which predicts the relative susceptibility of bipolar RAMs to heavy ion and proton upset. During the course of evaluating this model, physical and electrical variations were also evaluated indicating that the minimum internal signal level is the primary upset susceptibility indicator. Unfortunately, all of the physical and electrical variations expected during a normal product development cycle are in direct opposition to improved high-energy particle upset tolerance. Hence, a trade-off between highly susceptible, low power (medium speed) devices must be made against the less susceptible, higher power (high speed) equivalent device, taking into account the systems trade-off with respect to system power, software, error correction procedures and/or circuit redundancy.

Myers, D. K.↗

Ionic Liquids and New Proton Exchange Membranes for Fuel Cells

There is currently a great surge of activity in fuel cell research as laboratories across the world seek to take advantage of the high energy capacity provided by &el cells relative to those of other portable electrochemical power systems. Much of this activity is aimed at high temperature fie1 cells, and a vital component of such &el cells must be the availability of a high temperature stable proton-permeable membrane. NASA Glenn Research Center is greatly involved in developing this technology. Other approaches to the high temperature fuel cell involve the use of single- component or almost-single-component electrolytes that provide a path for protons through the cell. A heavily researched case is the phosphoric acid fuel cell, in which the electrolyte is almost pure phosphoric acid and the cathode reaction produces water directly. The phosphoric acid fie1 cell delivers an open circuit voltage of 0.9 V falling to about 0.7 V under operating conditions at 170 C. The proton transport mechanism is mainly vehicular in character according to the viscosity/conductance relation. Here we describe some Proton Transfer Ionic Liquids (PTILs) with low vapor pressure and high temperature stability that have conductivities of unprecedented magnitude for non-aqueous systems. The first requirement of an ionic liquid is that, contrary to experience with most liquids consisting of ions, it must have a melting point that is not much above room temperature. The limit commonly suggested is 100 C. PTILs constitute an interesting class of non-corrosive proton-exchange electrolyte, which can serve well in high temperature (T = 100 - 250 C) fuel cell applications. We will present cell performance data showing that the open circuit voltage output, and the performance of a simple H2(g)Pt/PTIL/Pt/O2(g) fuel cell may be superior to those of the equivalent phosphoric acid electrolyte fuel cell both at ambient temperature and temperatures up to and above 200 C. My work at NASA Glenn Research Center during this summer is to develop and characterize proton exchange membranes doped with ionic liquids. The main techniques used to characterize these materials are: Impedance Spectroscopy, NMR, DSC, TGA, DMA, IR, and SEM ...

Belieres, Jean-Philippe↗

Enhanced Low Dose Rate Effects in Bipolar Circuits: A New Hardness Assurance Problem for NASA

Many bipolar integrated circuits are much more susceptible to ionizing radiation at low dose rates than they are at high dose rates typically used for radiation parts testing. Since the low dose rate is equivalent to that seen in space, the standard lab test no longer can be considered conservative and has caused the Air Force to issue an alert. Although a reliable radiation hardness assurance test has not yet been designed, possible mechanisms for low dose rate enhancement and hardness assurance tests are discussed.

bipolar integrated circuits↗

Flexible composite film for printed circuit board

A flexible printed circuit for a printed circuit board in which layers of reaction product composed of a combination of phenoxy resin - polyisocyanate - brominated epoxy resin, and in which the equivalent ratio of those functional groups is hydroxyl group: isocyanate group: epoxy group - 1 : 0.2 to 2 : 0.5 to 3 are laminated on at least one side of saturated polyester film is discussed.

Yabe, K.↗