Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Re-evaluation of ortho-para- dependence of self pressure-broadening in the ν 1 + ν 3 band of acetylene

Optical frequency comb-referenced measurements of self pressure-broadened line profiles of the R(8) to R(13) lines in the ν 1 + ν 3 combination band of acetylene near 1.52 µ m are reported. The analysis of the data found no evidence for a previously reported systematic alternation in self pressure-broadened line widths with the nuclear spin state of the molecule. This work brought out the need for the use of an accurate line profile model and careful accounting for weak background absorptions due to hot band and lower abundance isotopomer lines. The data were adequately fit using the quadratic speed-dependent Voigt profile model, neglecting the small speed-dependent shift. Parameters describing the most probable and speed-dependent pressure-broadening, most probable shift, and the line strength were determined for each line. Detailed modeling of the results of Iwakuni et al. showed that their neglect of collisional narrowing due to the speed-dependent broadening term combined with the strongly absorbing data recorded and analyzed in transmission mode were the reasons for their results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗

Free space Thomson scattering to study high energy density shocks

A free space collective Thomson scattering system has been developed to study pulsed power produced plasmas. While most Thomson scattering diagnostics on pulsed power machines use a bundle of fibers to couple scattered light from the plasma to the spectrometer, this system used free space coupling of the light, which enabled a spatially continuous image of the plasma. Initial experiments with this diagnostic were performed on an inverse wire array generated by a 200 kA, 1100 ns rise time pulse power generator. The capabilities of this diagnostic were demonstrated by using the low frequency ion acoustic wave feature of the Thomson scattering spectra to measure the plasma flow velocity. The diagnostic was demonstrated to measure velocities between 20 and 40 km/s with an error of 4.7 km/s when fitting with a 600 μm spatial resolution or 8.9 km/s when fitting with a 150 μm spatial resolution. In some experiments, the diagnostic observed a bow shock in the plasma flow as the scattering intensity increased and flow velocity decreased.

47 OTHER INSTRUMENTATION↗

High resolution x-ray emission spectrometer for multiple hard x-ray emission lines: Demonstration for Cu Kα and Kβ emissions

In this work, we present a compact 3D printed x-ray emission spectrometer based on the von Hamos geometry that represents a significant upgrade to the existing von Hamos geometry-based miniature x-ray emission spectrometer (miniXES). The upgrades include the incorporation of a higher pixel density 500K detector for improved energy resolution and an enlarged sample area to accommodate a wider range of sample formats. The versatile spectrometer houses removable crystal holders that can be easily exchanged, as well as movable alignment eyelets that give flexibility in Bragg angle selection. Designed for ease of manufacture, all the components, except for the apertures, can be 3D printed and readily assembled. We describe its implementation in measurements of resonant and non-resonant Cu Kα and Kβ x-ray emission and report the theoretical and measured energy resolution and collected solid angle of the emission.

3D printing↗

Radio frequency mixing modules for superconducting qubit room temperature control systems

As the number of qubits in nascent quantum processing units increases, the connectorized RF (radio frequency) analog circuits used in first generation experiments become exceedingly complex. The physical size, cost, and electrical failure rate all become limiting factors in the extensibility of control systems. We have developed a series of compact RF mixing boards to address this challenge by integrating I/Q quadrature mixing, intermediate frequency/LO (local oscillator)/RF power level adjustments, and direct current bias fine tuning on a 40 × 80 mm 2 four-layer printed circuit board with electromagnetic interference shielding. The RF mixing module is designed to work with RF and LO frequencies between 2.5 and 8.5 GHz. The typical image rejection and adjacent channel isolation are measured to be ~27 dBc and ~50 dB. By scanning the drive phase in a loopback test, the module short-term amplitude and phase linearity are typically measured to be 5 ×10 -4 (V pp /V mean ) and 1 ×10 -3 radian (pk-pk). The operation of the RF mixing board was validated by integrating it into the room temperature control system of a superconducting quantum processor and executing randomized benchmarking characterization of single and two qubit gates. We measured a single-qubit process infidelity of 9.3(3) × 10 -4 and a two-qubit process infidelity of 2.7(1) × 10 -2 .

47 OTHER INSTRUMENTATION↗

Raster Thomson scattering in large-scale laser plasmas produced at high repetition rate

We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1 Hz). The Thomson scattering diagnostic matches this high repetition rate. Unlike previous work performed in single shots at much higher energies, the instrument allows point measurements anywhere inside the plasma by automatically translating the scattering volume using motorized stages as the experiment is repeated at 1 Hz. Measured densities around 4×10 16 cm -3 and temperatures around 7 eV result in a scattering parameter near unity, depending on the distance from the target. The measured spectra show the transition from collective scattering close to the target to non-collective scattering at larger distances. Densities obtained by fitting the weakly collective spectra agree to within 10% with an irradiance calibration performed via Raman scattering in nitrogen.

47 OTHER INSTRUMENTATION↗

Extension of the flux fit method for estimating power deposition profiles

The flux fit method is used to self-consistently estimate the power deposition profile and heat transport profiles from temperature measurements originating from perturbative experiments with a modulated source. Furthermore, this letter improves on this method by addressing the limitations and assumptions. The most crucial improvement is the additional freedom in the source deposition profile. Allowing for a variable central deposition location and height and including a skewness parameter produces deposition profiles more consistent with the measurement data, but still wider than equilibrium ray tracing in two different DIII-D discharges. Moreover, we show that the quality of the estimated deposition profile is key to the accuracy of diffusivity and connectivity estimates, but inversely, the estimated transport parameters hardly affect the quality of the power deposition estimate. Using this method, we show that the power deposition profile estimate is broadened with respect to ray-tracing by about 1.7-1.8 times in two DIII-D discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A study of space charge induced non-linearity in the Single Line Of Sight camera

We report a new generation of gated x-ray detectors at the National Ignition Facility has brought faster, enhanced imaging capabilities. Their performance is currently limited by the amount of signal they can be operated with before space charge effects in their electron tube start to compromise their temporal and spatial response. We present a technique to characterize this phenomenon and apply it to a prototype of such systems, the Single Line Of Sight camera. Results of this characterization are used to benchmark Particle In Cell simulations of the electrons drifting inside the detector, which are found to well reproduce experimental data. These simulations are then employed to predict the optimum photon flux to the camera, with the goal to increase the quality of the images obtained on an experimental campaign while preventing the appearance of deleterious effects. They also offer some insight into some of the improvements that can be brought to the new pulse-dilation systems being built at Lawrence Livermore National Laboratory

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bootstrap estimation of the effect of instrument response function uncertainty on the reconstruction of fusion neutron sources

Neutron imagers are important diagnostics for the inertial confinement fusion implosions at the National Ignition Facility. They provide two- and three-dimensional reconstructions of the neutron source shape that are key indicators of the overall performance. To interpret the shape results properly, it is critical to estimate the uncertainty in those reconstructions. There are two main sources of uncertainties: limited neutron statistics, leading to random errors in the reconstructed images, and incomplete knowledge of the instrument response function (the pinhole-dependent point spread function). While the statistical errors dominate the uncertainty for lower yield deuterium-tritium (DT) shots, errors due to the instrument response function dominate the uncertainty for DT yields on the order of 10 16 neutrons or higher. In this work, a bootstrapping method estimates the uncertainty in a reconstructed image due to the incomplete knowledge of the instrument response function. The main reconstruction is created from the fixed collection of pinhole images that are best aligned with the neutron source. Additional reconstructions are then built using subsets of that collection of images. Variations in the shapes of these additional reconstructions originate solely from uncertainties in the instrument response function, allowing us to use them to provide an additional systematic uncertainty estimate.

47 OTHER INSTRUMENTATION↗

Thomson scattering on the large plasma device

We have developed a non-collective Thomson scattering diagnostic for measurements of electron density and temperature on the Large Plasma Device. A triple grating spectrometer with a tunable notch filter is used to discriminate the faint scattering signal from the stray light. In this paper, we describe the diagnostic and its calibration via Raman scattering and present the first measurements performed with the fully commissioned system. Depending on the discharge conditions, the measured densities and temperatures range from 4.0 × 10 12 to 2.8 × 10 13 cm -3 and from 1.2 to 6.8 eV, respectively. The variation of the measurement error with plasma parameters and discharges averaged is also discussed.

47 OTHER INSTRUMENTATION↗

Analysis and mitigation of an oscillating background on hybrid complementary metal-oxide semiconductor (hCMOS) imaging sensors at the National Ignition Facility

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Finally, data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

42 ENGINEERING↗

Ga:Ge array development

Work at the University of Arizona and at Lawrence Berkeley Laboratory on the development of a far infrared array camera for the Multiband Imaging Photometer on the Space Infrared Telescope Facility (SIRTF) is discussed. The camera design uses stacked linear arrays of Ge:Ga photoconductors to make a full two-dimensional array. Initial results from a 1 x 16 array using a thermally isolated J-FET readout are presented. Dark currents below 300 electrons s(exp -1) and readout noises of 60 electrons were attained. Operation of these types of detectors in an ionizing radiation environment are discussed. Results of radiation testing using both low energy gamma rays and protons are given. Work on advanced C-MOS cascode readouts that promise lower temperature operation and higher levels of performance than the current J-FET based devices is described.

Young, Erick T.↗

Detailed analysis of low energy plasma data under the Voyager Uranus data analysis program

Research effort included the PLS data analysis program where modifications to the data fitting procedure and elimination of possible noise and electron contamination were made. The analysis code corrections were used in checking the Neptune data gathered during the Voyager 2 encounter and for analyzing selected plasma spectra from the warm Io torus. A major task accomplished was the summary of Uranus-related research in the U.S. National Report to the International Union of Geodesy and Geophysics for the 1987 - 1990 quadrennium. A limited amount of work was accomplished on assessing the Pedersen conductivity of the ionosphere and comparing it with inferred values from shielding by the Uranian ring current. Under this grant there has been a great deal of effort expended on identifying and classifying plasma waves and oscillations in the magnetosheath and solar wind downstream from Uranus. Large amplitude oscillations in plasma parameters are found in the magnetosheath, with density changes of up to a factor of ten occurring on times scales of minutes. New algorithms developed for analyzing the inbound bow shock crossing of Neptune will probably be applied to a more detailed analysis of the Uranus shock in the near future.

Mcnutt, Ralph L., Jr.↗

Static and dynamic force/moment measurements in the Eidetics water tunnel

Water tunnels have been utilized in one form or another to explore fluid mechanics and aerodynamics phenomena since the days of Leonardo da Vinci. Water tunnel testing is attractive because of the relatively low cost and quick turn-around time to perform flow visualization experiments and evaluate the results. The principal limitation of a water tunnel is that the low flow speed, which provides for detailed visualization, also results in very small hydrodynamic (aerodynamic) forces on the model, which, in the past, have proven to be difficult to measure accurately. However, the advent of semi-conductor strain gage technology and devices associated with data acquisition such as low-noise amplifiers, electronic filters, and digital recording have made accurate measurements of very low strain levels feasible. The principal objective of this research effort was to develop a multi-component strain gage balance to measure forces and moments on models tested in flow visualization water tunnels. A balance was designed that allows measuring normal and side forces, and pitching, yawing and rolling moments (no axial force). The balance mounts internally in the model and is used in a manner typical of wind tunnel balances. The key differences between a water tunnel balance and a wind tunnel balance are the requirement for very high sensitivity since the loads are very low (typical normal force is 0.2 lbs), the need for water proofing the gage elements, and the small size required to fit into typical water tunnel models.

Carlos J Suarez↗

Molecular modeling of polymer composite interactions with analytes in electronic nose sensors for environmental monitoring in International Space Station

We report a molecular modeling study to investigate the polymer-carbon black (CB) composite-analyte interactions in resistive sensors. These sensors comprise the JPL Electronic Nose (ENose) sensing array developed for monitoring breathing air in human habitats. The polymer in the composite is modeled based on its stereisomerism and sequence isomerism, while the CB is modeled as uncharged naphthalene rings (with no hydrogens). The Dreiding 2.21 force field is used for the polymer and solvent molecules and graphite parameters are assigned to the carbon black atoms. A combination of molecular mechanics (MM) and molecular dynamics (NPT-MD and NVT-MD) techniques are used to obtain the equilibrium composite structure by inserting naphthalene rings in the polymer matrix. Polymers considered for this work include poly(4- vinylphenol), polyethylene oxide, and ethyl cellulose. Analytes studied are representative of both inorganic (ammonia) and organic (methanol, toluene, hydrazine) compounds. The results are analyzed for the composite microstructure by calculating the radial distribution profiles as well as for the sensor response by predicting the interaction energies of the analytes with the composites.

electronic noise environmental monitoring polymer ↗

Molecular modeling of interactions in electronic nose sensors for environmental monitoring

We report a study aimed at understanding analyte interactions with sensors made from polymer-carbon black composite films. The sensors are used in an Electronic Nose (ENose) which is used for monitoring the breathing air quality in human habitats. The model mimics the experimental conditions of the composite film deposition and formation and was developed using molecular modeling and simulation tools. The Dreiding 2.21 Force Field was used for the polymer and analyte molecules while graphite parameters were assigned to the carbon black atoms. The polymer considered for this work is methyl vinyl ether / maleic acid copolymer. The target analytes include both inorganic (NH3) and organic (methanol) types of compound. Results indicate different composite-analyte interaction behavior.

electronic noise polymer-carbon composite molecula↗