Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Day-to-Day Variability of Ionosphere Electron Density During Solar Minimum Derived From FORMOSAT-7/COSMIC-2 Measurements

This study examines the day-to-day variability of low-latitude ionosphere using global ionospheric specification (GIS) electron density profiles derived from FORMOSAT-7/COSMIC-2 radio occultation measurements during a deep solar minimum period of August 2019 to July 2020. The measurements reveal significant daily variations over dayside low latitudes, yielding about 10-20% standard deviation in equinoxes, 20-30% in solstices, reaching 40-50% in winter. The nighttime deviations could be 30-60%, being largest in solstices. Day-to-day variations are also observed in the longitudinal wave-4 structures. The period mostly remained geomagnetically quiet except for some moderate disturbances on a few days. Tidal decomposition of the GIS electron density shows that in-situ forced migrating diurnal (DW1) terdiurnal (TW3) oscillations and the background zonal mean yield only ~25% of the daily variations despite accounting for almost 75-90% of the observed electron density. Thus, forcing from lower atmosphere dominates the contribution (~75%) to the observed daily variations. Only about one third of this lower atmospheric forcing comes from the migrating semidiurnal SW2 and the usually investigated non-migrating diurnal eastward DE2, DE3, stationary planetary wave SPW3, SPW4, and semidiurnal eastward SE1, and SE2 components. The residual tides other than those mentioned above, including secondary waves through non-linear interactions and other planetary waves, thus significantly influence the day-to-day variations in electron density and modify the longitudinal wave structures.

day-to-day variability↗

Steady-state modification of the electron density profile in the resonance region of moving plasma subjected to an alternating electric field

Self-consistent electron density profiles of the plasma stream interacting with the electric field of an ultrashort laser pulse are calculated in the framework of the one-dimensional steady-state model with nonlocal polarizability. These profiles are settled down against the background of a given (linear) ion density distribution as a result of the equilibrium between the averaged ponderomotive force, the static space-charge field, and the electron pressure. The average electron density and the longitudinal (parallel to the density gradient) ac electric field are found to be greatly space-modulated in the region downstream of the plasma resonance point.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Approaching an experimental electron density model of the biologically active trans -epoxysuccinyl amide group-Substituent effects vs. crystal packing

The trans-epoxysuccinyl amide group as a biologically active moiety in cysteine protease inhibitors such as loxistatin acid E64c has been used as a benchmark system for theoretical studies of environmental effects on the electron density of small active ingredients in relation to their biological activity. Here, the synthesis and the electronic properties of the smallest possible active site model compound are reported to close the gap between the unknown experimental electron density of trans-epoxysuccinyl amides and the well-known function of related drugs. Intramolecular substituent effects are separated from intermolecular crystal packing effects on the electron density, which allows us to predict the conditions under which an experimental electron density investigation on trans-epoxysuccinyl amides will be possible. In this context, the special importance of the carboxylic acid function in the model compound for both crystal packing and biological activity is revealed through the novel tool of model energy analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron capture {beta} decay of {sup 7}Be encapsulated in C{sub 60}: Origin of increased electron density at the {sup 7}Be nucleus

We offer a new theoretical interpretation for the effect of enhanced electron density at the {sup 7}Be nucleus encapsulated in fullerene C{sub 60}. Our ab initio Hartree-Fock calculations show that the electron density at the {sup 7}Be nucleus in {sup 7}Be-C{sub 60} increases due to the attractive effective potential well generated by the fullerene. The 2s state in the isolated Be atom turns into a 3s state in the joint potential. This new state has higher energy and slightly larger amplitude at the Be nucleus than the previous 2s state. Moreover the 3s wave function has an additional node that appeared at a distance rapprox =5a{sub B} from the center. The node imitates repulsion between the Be electron and the fullerene wall because the electron has zero probability to occupy this region. Such an imitation of the repulsion by means of the node in an attractive potential has a direct physical analogy in the theory of {alpha}-{alpha} and N-N nuclear interactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generalization of the Kohn-Sham system that can represent arbitrary one-electron density matrices

Density functional theory is currently the most widely applied method in electronic structure theory. The Kohn-Sham method, based on a fictitious system of noninteracting particles, is the workhorse of the theory. The particular form of the Kohn-Sham wave function admits only idempotent one-electron density matrices whereas wave functions of correlated electrons in post-Hartree-Fock methods invariably have fractional occupation numbers. Here we show that by generalizing the orbital concept and introducing a suitable dot product as well as a probability density, a noninteracting system can be chosen that can represent the one-electron density matrix of any system, even one with fractional occupation numbers. This fictitious system ensures that the exact electron density is accessible within density functional theory. It can also serve as the basis for reduced density matrix functional theory. Moreover, to aid the analysis of the results the orbitals may be assigned energies from a mean-field Hamiltonian. This produces energy levels that are akin to Hartree-Fock orbital energies such that conventional analyses based on Koopmans' theorem are available. Lastly, this system is convenient in formalisms that depend on creation and annihilation operators as they are trivially applied to single-determinant wave functions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-43: Deformed Planning CT as An Electron Density Substitute for Cone-Beam CT

Purpose: To confirm that deforming the planning CT to the daily Cone-Beam CTs (CBCT) can provide suitable electron density for adaptive planning. We quantify the dosimetric difference between plans calculated on deformed planning CTs (DPCT) and daily CT-on-rails images (CTOR). CTOR is used as a test of the method as CTOR already contains accurate electron density to compare against. Methods: Five prostate only IMRT patients, each with five CTOR images, were selected and re-planned on Panther (Prowess Inc.) with a uniform 5 mm PTV expansion, prescribed 78 Gy. The planning CT was deformed to match each CTOR using ABAS (Elekta Inc.). Contours were drawn on the CTOR, and copied to the DPCT. The original treatment plan was copied to both the CTOR and DPCT, keeping the center of the prostate as the isocenter. The plans were then calculated using the collapsed cone heterogeneous dose engine of Prowess and typical DVH planning parameters used to compare them. Results: Each DPCT was visually compared to its CTOR with no differences observed. The agreement of the copied CTOR contours with the DPCT anatomy further demonstrated the deformation accuracy. The plans calculated using CTOR and DPCT were compared. Over the 25 plan pairs, the average difference between them for prostate D100, D98 and D95 were 0.5%, 0.2%, and 0.2%; PTV D98, D95 and mean dose: 0.3%, 0.2% and 0.3%; bladder V70, V60 and mean dose: 1.1%, 0.7%, and 0.2%; and rectum mean dose: 0.3%. (D100 is the dose covering 100% of the target; V70 is the volume of the organ receiving 70 Gy). Conclusion: We observe negligible difference between the dose calculated on the DPCT and the CTOR, implying that deformed planning CTs are a suitable substitute for electron density. The method can now be applied to CBCTs. Research version of Panther provided by Prowess Inc. Research version of ABAS provided by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-T-300: Impact of Electron Density Modeling of ArcCHECK Cylindricaldiode Array On 3DVH Patient Specific QA Software Tool Analysis

Purpose: 3DVH software is a patient specific quality assurance tool which estimates the 3D dose to the patient specific geometry with the help of Planned Dose Perturbation algorithm. The purpose of this study is to evaluate the impact of HU value of ArcCHECK phantom entered in Eclipse TPS on 3D dose & DVH QA analysis. Methods: Manufacturer of ArcCHECK phantom provides CT data set of phantom & recommends considering it as a homogeneous phantom with electron density (1.19 gm/cc or 282 HU) close to PMMA. We performed this study on Eclipse TPS (V13, VMS) & trueBEAM STx VMS Linac & ArcCHECK phantom (SNC). Plans were generated for 6MV photon beam, 20cm×20cm field size at isocentre & SPD (Source to phantom distance) of 86.7 cm to deliver 100cGy at isocentre. 3DVH software requires patients DICOM data generated by TPS & plan delivered on ArcCHECK phantom. Plans were generated in TPS by assigning different HU values to phantom. We analyzed gamma index & the dose profile for all plans along vertical down direction of beam’s central axis for Entry, Exit & Isocentre dose. Results: The global gamma passing rate (2% & 2mm) for manufacturer recommended HU value 282 was 96.3%. Detector entry, Isocentre & detector exit Doses were 1.9048 (1.9270), 1.00(1.0199) & 0.5078(0.527) Gy for TPS (Measured) respectively.The global gamma passing rate for electron density 1.1302 gm/cc was 98.6%. Detector entry, Isocentre & detector exit Doses were 1.8714 (1.8873), 1.00(0.9988) & 0.5211(0.516) Gy for TPS (Measured) respectively. Conclusion: Electron density value assigned by manufacturer does not hold true for every user. Proper modeling of electron density of ArcCHECK in TPS is essential to avoid systematic error in dose calculation of patient specific QA.

60 APPLIED LIFE SCIENCES↗

Direct phase selection of initial phases from single-wavelength anomalous dispersion (SAD) for the improvement of electron density and ab initio structure determination

A novel direct phase-selection method to select optimized phases from the ambiguous phases of a subset of reflections to replace the corresponding initial SAD phases has been developed. With the improved phases, the completeness of built residues of protein molecules is enhanced for efficient structure determination. Optimization of the initial phasing has been a decisive factor in the success of the subsequent electron-density modification, model building and structure determination of biological macromolecules using the single-wavelength anomalous dispersion (SAD) method. Two possible phase solutions (ϕ{sub 1} and ϕ{sub 2}) generated from two symmetric phase triangles in the Harker construction for the SAD method cause the well known phase ambiguity. A novel direct phase-selection method utilizing the θ{sub DS} list as a criterion to select optimized phases ϕ{sub am} from ϕ{sub 1} or ϕ{sub 2} of a subset of reflections with a high percentage of correct phases to replace the corresponding initial SAD phases ϕ{sub SAD} has been developed. Based on this work, reflections with an angle θ{sub DS} in the range 35–145° are selected for an optimized improvement, where θ{sub DS} is the angle between the initial phase ϕ{sub SAD} and a preliminary density-modification (DM) phase ϕ{sub DM}{sup NHL}. The results show that utilizing the additional direct phase-selection step prior to simple solvent flattening without phase combination using existing DM programs, such as RESOLVE or DM from CCP4, significantly improves the final phases in terms of increased correlation coefficients of electron-density maps and diminished mean phase errors. With the improved phases and density maps from the direct phase-selection method, the completeness of residues of protein molecules built with main chains and side chains is enhanced for efficient structure determination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Moving electron density gratings induced in the beat-wave field of two counterpropagating laser pulses

The production and physical characteristics of moving electron density gratings (MEDGs) are investigated by analytical model and particle-in-cell (PIC) simulations. When the frequency difference of two counterpropagating pump pulses is equal to the electron plasma frequency, large amplitude electron plasma wave is resonantly excited in the plasma. As a result, electrons are excited to form a moving, gratinglike structure in the interfering region of pump pulses, while the ions keep at rest. The spatial period and velocity of the MEDG are obtained by solving the electron density modulation equation, which agrees well with one-dimensional PIC simulation results. When a short signal laser pulse is scattered on the MEDG, the frequency of the backscattering wave shifts due to the stimulated Raman scattering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The coronal electron density distribution determined from dual-frequency ranging measurements during the 1991 solar conjunction of the Ulysses spacecraft

Dual-frequency ranging and Doppler measurements were conducted in support of the Ulysses Solar Corona Experiment (SCE) at and around the spacecraft's first solar conjunction in 1991 August. The differential group delay time between range codes on the two downlink carrier signals at the wavelengths 13.1 and 3.6 cm, a direct measure of the total electron content between spacecraft and ground station, was used to derive the electron density distribution in the solar corona. Linear power-law representations of the coronal electron density were derived for the range of solar distances from 4 solar radii to 40 solar radii on both sides of the Sun. The corona was found to be very nearly symmetric; the radial falloff exponent being 2.54 +/- 0.05 for occultation ingress (east solar limb) and 2.42 +/- 0.05 for egress (west limb), respectively. The departure of these exponents from the inverse equare relation implies that significant solar wind acceleration is occurring within the radial range of the observations. The electron density level was found to be considerably lower than that observed during the 1988 December solar occultation of Voyager 2. Although the smoothed sunspot number R(sub z) (a standard indicator of solar activity) was almost the same in 1988 December and 1991 August, the mean electron density at 20 solar radii was found to be 1.7 +/- 0.1 x 10(exp 3)/cu cm during the Ulysses conjunction, a decline by almost a factor of 4 from the value obtained during the Voyager conjunction.

Bird, M. K.↗

Stark broadening measurement of the electron density in an atmospheric pressure argon plasma jet with double-power electrodes

Characteristics of a double-power electrode dielectric barrier discharge of an argon plasma jet generated at the atmospheric pressure are investigated in this paper. Time-averaged optical emission spectroscopy is used to measure the plasma parameters, of which the excitation electron temperature is determined by the Boltzmann's plot method whereas the gas temperature is estimated using a fiber thermometer. Furthermore, the Stark broadening of the hydrogen Balmer H{sub {beta}} line is applied to measure the electron density, and the simultaneous presence of comparable Doppler, van der Waals, and instrumental broadenings is discussed. Besides, properties of the jet discharge are also studied by electrical diagnosis. It has been found that the electron densities in this argon plasma jet are on the order of 10{sup 14} cm{sup -3}, and the excitation temperature, gas temperature, and electron density increase with the applied voltage. On the other hand, these parameters are inversely proportional to the argon gas flow rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Propagation of terahertz waves in an atmospheric pressure microplasma with Epstein electron density profile

Propagation properties of terahertz (THz) waves in a bounded atmospheric-pressure microplasma (AMP) are analyzed in this study. A modified Epstein profile model is used to simulate the electron density distribution caused by the plasma sheaths. By introducing the dielectric constant of a Drude-Lorentz model and using the method of dividing the plasma into a series of subslabs with uniform electron density, the coefficients of power reflection, transmission, and absorption are derived for a bounded microplasma structure. The effects of size of microplasma, electron density profile, and collision frequency on the propagation of THz waves are analyzed numerically. The results indicate that the propagation of THz waves in AMPs depend greatly on the above three parameters. It is demonstrated that the THz wave can play an important role in AMPs diagnostics; meanwhile, the AMP can be used as a novel potential tool to control THz wave propagation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rocket radio measurement of electron density in the nighttime ionosphere

One experimental technique based on the Faraday rotation effect of radio waves is presented for measuring electron density in the nighttime ionosphere at midlatitudes. High frequency linearly-polarized radio signals were transmitted to a linearly-polarized receiving system located in a spinning rocket moving through the ionosphere. Faraday rotation was observed in the reference plane of the rocket as a change in frequency of the detected receiver output. The frequency change was measured and the information was used to obtain electron density data. System performance was evaluated and some sources of error were identified. The data obtained was useful in calibrating a Langmuir probe experiment for electron density values of 100/cu cm and greater. Data from two rocket flights are presented to illustrate the experiment.

Gilchrist, B. E.↗

Electron densities and alkali atoms in exoplanet atmospheres

We describe a detailed study on the properties of alkali atoms in extrasolar giant planets, and specifically focus on their role in generating the atmospheric free electron densities, as well as their impact on the transit depth observations. We focus our study on the case of HD 209458b, and we show that photoionization produces a large electron density in the middle atmosphere that is about two orders of magnitude larger than the density anticipated from thermal ionization. Our purely photochemical calculations, though, result in a much larger transit depth for K than observed for this planet. This result does not change even if the roles of molecular chemistry and excited state chemistry are considered for the alkali atoms. In contrast, the model results for the case of exoplanet XO-2b are in good agreement with the available observations. Given these results we discuss other possible scenarios, such as changes in the elemental abundances, changes in the temperature profiles, and the possible presence of clouds, which could potentially explain the observed HD 209458b alkali properties. We find that most of these scenarios cannot explain the observations, with the exception of a heterogeneous source (i.e., clouds or aerosols) under specific conditions, but we also note the discrepancies among the available observations.

79 ASTRONOMY AND ASTROPHYSICS↗