Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic programming”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Power Split Supercharging: A Mild Hybrid Approach to Boost Fuel Economy

This work investigates an innovative low-voltage (<60 V) hybrid device that enables engine boosting and downsizing in addition to mild hybrid functionalities such as regenerative braking, start-stop, and torque assist. A planetary gear set and a brake permit the power split supercharger (PSS) to share a 9 kW motor between supercharging the engine and direct torque supply to the crankshaft. In contrast, most e-boosting schemes use two separate motors for these two functionalities. This single motor structure restricts the PSS operation to only one of the supercharging or parallel hybrid modes; therefore, an optimized decision making strategy is necessary to select both the device mode and its power split ratio. An adaptive equivalent consumption minimization strategy (A-ECMS), which uses the battery state of charge (SoC) history to adjust the equivalence factor, is developed for energy management of the PSS. The A-ECMS effectiveness is compared against a dynamic programming (DP) solution with full drive cycle preview through hardware-in-the-loop experiments on an engine dynamometer testbed. The experiments show that the PSS with A-ECMS reduces vehicle fuel consumption by 18.4% over standard FTP75 cycle, compared to a baseline turbocharged engine, while global optimal DP solution decreases the fuel consumption by 22.8% compared to the baseline.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Real Time Predictive and Adaptive Hybrid Powertrain Control Development via Neuroevolution

The real-time application of powertrain-based predictive energy management (PrEM) brings the prospect of additional energy savings for hybrid powertrains. Torque split optimal control methodologies have been a focus in the automotive industry and academia for many years. Their real-time application in modern vehicles is, however, still lagging behind. While conventional exact and non-exact optimal control techniques such as Dynamic Programming and Model Predictive Control have been demonstrated, they suffer from the curse of dimensionality and quickly display limitations with high system complexity and highly stochastic environment operation. This paper demonstrates that Neuroevolution associated drive cycle classification algorithms can infer optimal control strategies for any system complexity and environment, hence streamlining and speeding up the control development process. Neuroevolution also circumvents the integration of low fidelity online plant models, further avoiding prohibitive embedded computing requirements and fidelity loss. This brings the prospect of optimal control to complex multi-physics system applications. The methodology presented here covers the development of the drive cycles used to train and validate the neurocontrollers and classifiers, as well as the application of the Neuroevolution process.

33 ADVANCED PROPULSION SYSTEMS↗

Analysis of the Effect of Vehicle Platooning on the Optimal Control of a Heavy Duty Engine Thermal System

One promising method for reducing fuel consumption and emissions, particularly in heavy duty trucks, is platooning. As the distance between vehicles decreases, the following vehicles will experience less aerodynamic drag on the front of the vehicle. However, reducing the velocity of the air contacting the front of the vehicle could have adverse effects on the temperature of the engine. To compensate for this effect, the energy consumption of the engine cooling system might increase, ultimately limiting the overall improvements obtained with platooning. Understanding the coupling between drag reduction and engine cooling load requirement is key for successfully implementing platooning strategies. Additionally, in a Connected and Automated Vehicle (CAV) environment, where information of the future engine load becomes available, the operation of the cooling system can be optimized in order to achieve the maximum fuel consumption reduction. In this paper, a control-oriented physics-based model for the engine cooling loop of a Volvo engine is developed and validated against road data. Starting from the validated model, an optimal control problem for the coolant system is formulated considering the tradeoff between the tracking of the engine temperature setpoint and the corresponding fuel consumption under different trailing distances. To compare the coolant system performance, Dynamic Programming (DP) is used to determine the global optimal solution for the coolant system actuator. The coupling between optimal cooling system operation and reduction in ram air are evaluated by comparing the results obtained from the DP under different platooning conditions against the unrestricted scenario. In addition, the paper analyzes the changes in the tradeoff between fuel consumption and setpoint tracking for different vehicle distances. This analysis will provide useful insight on the sensitivity of the coolant system controller calibration to the platoon distance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Centralized Stochastic Optimal Control of Complex Systems

In this paper we address the problem of online optimization of the supervisory power management control in parallel hybrid electric vehicles (HEVs). We model HEV operation as a controlled Markov chain using the long-run expected average cost per unit time criterion, and we show that the control policy yielding the Pareto optimal solution minimizes the average cost criterion online. The effectiveness of the proposed solution is validated through simulation and compared to the solution derived with dynamic programming using the average cost criterion.

complex systems↗

Fused Global-Local Economic Model Predictive Control for Real-Time Eco-Optimal Control of a Heavy Duty Truck

This paper introduces a fused global-local economic model predictive control (MPC) with varying time steps for maximizing the fuel economy of a heavy-duty truck, where global MPC is performed over a long horizon using cloud-based dynamic programming (DP), and local MPC is performed on-board the vehicle using sequential quadratic programming (SQP). Because of the computational complexity of DP, an in-depth analysis of how the discretization levels, time constant, and horizon length influence the energy savings and computational complexity of online DP has been performed. The fused optimization technique has been evaluated over different route profiles, accounting for traffic, using a medium-fidelity proprietary Volvo model. Results show 4-7% fuel savings, as compared to a baseline model.

33 ADVANCED PROPULSION SYSTEMS↗

Building Battery Energy Storage System Performance Data into an Economic Assessment

Economic assessments of battery energy storage systems (BESSs) rely on optimal dispatch methods to capture temporal interdependency of BESS operations and coupling among different grid applications. Many existing BESS economic assessment studies are based on a simplified first-order scalar model using BESS nameplate numbers. Such a method cannot accurately capture varying capabilities and nonlinear dynamics of a BESS, leading to inaccurate assessment results. This paper presents a practical implementation of performance data into the economic assessment of the BESSs recently developed within the Snohomish Public Utility District system in Washington State. Extensive testing conducted over multiple seasons is used to assess the technical performance and develop high-fidelity models of the BESSs. A dynamic programming algorithm is proposed to optimally dispatch the BESSs and assess the potential benefits from stacked value streams. The proposed method can be adapted for the economic assessment of other BESSs with different applications.

Wu, Di↗

Model Predictive Control for a Grid-interactive Efficient Thermal Storage-integrated Heat Pump System

Building heating and cooling systems can be used to overcome the mismatch between the intermittent supply of renewable power and the fluctuating demand for electricity. A novel underground thermal energy storage integrated with a dual-source heat pump has been proposed to mitigate the mismatch while meeting the thermal demand of buildings efficiently. Conventional thermostat control with heuristic rules cannot provide intelligent decisions to maximize the thermal efficiency and flexibility of the proposed system. Advanced control strategies like model predictive control (MPC) have provided a new paradigm for grid-interactive efficient building operation with the advancement of computation and sensing. This study developed an MPC for the proposed system to provide grid service for Demand Side Management and minimize the operating cost of building owners. A control-oriented dynamic model of the proposed system has been developed. Given an objective function and proper constraints, an optimization problem is formulated to determine the optimal control strategy of the system. Dynamic Programming is adopted to solve the optimization problem. A rule-based control (RBC) is also developed to achieve similar goals. Short-term simulations are conducted to compare the system performance resulting from the two controls. The simulation results indicate that the MPC performs more intelligently than the RBC in charging thermal energy storage and selecting heat pump sources by taking advantage of the predicted cooling demands of the building and the performance of the integrated system. As a result, the MPC could save energy and reduce operating costs compared with the RBC. A case study shows that, for a 3-day operation, the MPC saves 36.9% energy and reduces 38.5% operating cost compared with the RBC.

Shi, Liang↗

Data-driven cyber attack detection and mitigation for decentralized wide-area protection and control in smart grids

Modern power systems have already evolved into complicated cyber physical systems (CPS), often referred to as smart grids, due to the continuous expansion of the electrical infrastructure, the augmentation of the number of heterogeneous system components and players, and the consequential application of a diversity of information and telecommunication technologies to facilitate the Wide Area Monitoring, Protection and Control (WAMPAC) of the day-to-day power system operation. Because of the reliance on cyber technologies, WAMPAC, among other critical functions, is prone to various malicious cyber attacks. Successful cyber attacks, especially those sabotage the operation of Bulk Electric System (BES), can cause great financial losses and social panics. Application of conventional IT security solutions is indispensable, but it often turns out to be insufficient to mitigate sophisticated attacks that deploy zero-day vulnerabilities or social engineering tactics. To further improve the resilience of the operation of smart grids when facing cyber attacks, it is desirable to make the WAMPAC functions per se capable of detecting various anomalies automatically, carrying out adaptive activity adjustments in time and thus staying unimpaired even under attack. Most of the existing research efforts attempt to achieve this by adding novel functional modules, such as model-based anomaly detectors, to the legacy centralized WAMPAC functions. In contrast, this dissertation investigates the application of data-driven algorithms in cyber attack detection and mitigation within a decentralized architecture aiming at improving the situational awareness and self-adaptiveness of WAMPAC. First part of the research focuses on the decentralization of System Integrity Protection Scheme (SIPS) with Multi-Agent System (MAS), within which the data-driven anomaly detection and optimal adaptive load shedding are further explored. An algorithm named as Support Vector Machine embedded Layered Decision Tree (SVMLDT) is proposed for the anomaly detection, which provides satisfactory detection accuracy as well as decision-making interpretability. The adaptive load shedding is carried out by every agent individually with dynamic programming. The load shedding relies on the load profile propagation among peer agents and the attack adaptiveness is accomplished by maintaining the historical mean of load shedding proportion. Load shedding only takes place after the consensus pertaining to the anomaly detection is achieved among all interconnected agents and it serves the purpose of mitigating certain cyber attacks. The attack resilience of the decentralized SIPS is evaluated using IEEE 39 bus model. It is shown that, unlike the traditional centralized SIPS, the proposed solution is able to carry out the remedial actions under most Denial of Service (DoS) attacks. The second part investigates the clustering based anomalous behavior detection and peer-assisted mitigation for power system generation control. To reduce the dimensionality of the data, three metrics are designed to interpret the behavior conformity of generator within the same balancing area. Semi-supervised K-means clustering and a density sensitive clustering algorithm based on Hierarchical DBSCAN (HDBSCAN) are both applied in clustering in the 3D feature space. Aiming to mitigate the cyber attacks targeting the generation control commands, a peer-assisted strategy is proposed. When the control commands from control center is detected as anomalous, i.e. either missing or the payload of which have been manipulated, the generating unit utilizes the peer data to infer and estimate a new generation adjustment value as replacement. Linear regression is utilized to obtain the relation of control values received by different generating units, Moving Target Defense (MTD) is adopted during the peer selection and 1-dimensional clustering is performed with the inferred control values, which are followed by the final control value estimation. The mitigation strategy proposed requires that generating units can communicate with each other in a peer-to-peer manner. Evaluation results suggest the efficacy of the proposed solution in counteracting data availability and data integrity attacks targeting the generation controls. However, the strategy stays effective only if less than half of the generating units are compromised and it is not able to mitigate cyber attacks targeting the measurements involved in the generation control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning for Well Log Analysis in Uranium Mining

This project explores the use of Artificial Intelligence (AI) and Machine Learning (ML) techniques to automate well log analysis for uranium mining. Geophysical log data—spontaneous potential, resistivity, and gamma ray—were used to classify lithology, correlate well logs and identify roll front zonation patterns, which are critical for locating uranium ore bodies. Supervised ML algorithms such as eXtreme Gradient Boosting (XGBoost), Categorical Boosting (CatBoost), and Random Forest were trained to classify lithology with high accuracy. Gradient Boosting Machines (GBM), XGBoost, Random Forest, and Neural Networks were also used for role front zone identification. Moreover, a Fast Dynamic Time Warping (FastDTW) algorithm was employed for well log correlation. Additionally, sample lag was addressed using dynamic programming. Results demonstrate the potential of AI and ML to streamline well log analysis and enhance uranium exploration workflows.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Control of Dipolar Dynamics by Geometrical Programming

We propose and theoretically analyze methods for quantum many-body control through geometric reshaping of molecular tweezer arrays. Dynamic rearrangement during entanglement is readily available due to the extended coherence times of molecular rotational qubits. We show how motional dephasing can be suppressed and enhanced spin squeezing can be achieved in an actively rearranged short-range XY model. We also analyze in detail a specific static geometry that significantly suppresses decoherence. These general methods as applied to programmable quantum systems offer robust control modalities that are well suited to molecules.

optical tweezers↗

Automatic Identification of Closed-Loop Wind Turbine Dynamics via Genetic Programming

Wind turbines are nonlinear systems that operate in turbulent environments. As such, their behavior is difficult to characterize accurately across a wide range of operating conditions by physically meaningful models. Customarily, data-based models of wind turbines are defined in 'black box' format, lacking in both conciseness and physical intelligibility. To address this deficiency, we identify models of a modern horizontal-axis wind turbine in symbolic form using a recently developed symbolic regression method. The method used relies on evolutionary multi-objective optimization to produce succinct dynamic models from operational data without 'a priori' knowledge of the system. We compare the produced models with models derived by other methods for their estimation capacity and evaluate the tradeoff between model intelligibility and accuracy. Several succinct models are found that predict wind turbine behavior as well as or better than more complex alternatives derived by other methods.

17 WIND ENERGY↗

Testing and Expertise for Marine Energy (TEAMER) Program Support: MRE Dynamic Seals Performance Investigation (CRADA Final Report)

This TEAMER project allows NREL to use and augment a custom special-purpose testing system to perform accelerated-life testing of rotating seals for use in the Marine Renewable Energy (“MRE”) industry. The requirements of this industry are different from most applications including marine, and relevant performance information is lacking. In order to achieve low costs with extremely effective and reliable operation over long periods deployed underwater, more study of the best seals and arrangements of seals must be performed. By developing a rigorous framework for such testing, NREL hopes to greatly improve understanding of the relevant factors and provide significant data to the industry. Further, this work can inform standards developments for this critical component of MRE systems, leading to maturation and improved acceptance of the industry in commerce.

16 TIDAL AND WAVE POWER↗

DXRD : a user-friendly suite of two- and multiple-beam dynamical X-ray diffraction programs

The DXRD program suite consisting of a series of dynamical theory programs is introduced for computing dynamical X-ray diffraction from single crystals. Its interactive graphical user interfaces (GUIs) allow general users to make complicated calculations with minimal effort. It can calculate plane-wave Darwin curves of single crystals (or multiple crystals) for both the Bragg and Laue cases, including grazing-incidence diffraction and backward diffraction (with Bragg angles approaching 90°). It is also capable of simulating rocking curves for divergent incident X-ray beams with finite bandwidths. A unique feature of DXRD is that it provides a convenient GUI-based multiple-beam diffraction program that can accurately compute arbitrary N-beam diffraction of any geometry using a universal 4N × 4N matrix method. DXRD also provides a mapping program for plotting all the multiple-beam diffraction lines (monochromator glitches) in the azimuth–energy coordinate system. All these functions make DXRD a convenient and powerful software tool for designing crystal-based synchrotron/X-ray optics (monochromators, analyzers, polarizers, phase plates etc.) and for crystal characterization, X-ray spectroscopy and X-ray diffraction teaching.

Bragg reflection↗

Implementation of ISO 50001 at Marine Corps Air Station Beaufort

The ISO 50001 implementation demonstration at U.S. Marine Corps Air Station (MCAS) Beaufort proved the feasibility of integrating an ISO 50001-conforming EnMS into existing command structures. The approach of leveraging external experts in gap analysis, EnMS training, and technical assistance were effective. In addition, strong leadership commitment and personnel resources were critical for success. Addressing typical personnel rotations by training newly rotated personnel and partnering key leadership positions in the EnMS structure with civilian counterparts can ensure program continuity. The project team brought forward many creative solutions that address the unique challenges for the Marine Corps and has paved the way for future Marine Corps EnMS implementations with example strategies and work products. Implementation of an ISO 50001 EnMS at additional Marine Corps facilities could provide for integration of base energy-related data systems and standardized energy reporting, using meaningful metrics for energy performance improvement. Beyond the energy performance improvement benefits of ISO 50001, widespread adoption of the standard at Marine Corps facilities would provide the communication and integration basis on which to reduce energy resiliency concern and could integrate energy service cyber security protections base wide. High levels of energy consumption, aggressive mandates from multiple sources, complex organizational structures, and constant personnel rotation make ISO 50001 a uniquely attractive proposition for the Marine Corps in support of the DoD’s overall energy strategy. The recently launched Energy Ethos and Unit Energy Manager (UEM) programs offer dynamic action-based programs over which ISO 50001 based business management can provide integrated governance of the Marine Corps installations’ energy programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How Do Electricity Pricing Programs Impact the Selection of Energy Efficiency Measures? - A Case Study with U.S. Medium Office Buildings

Building owners usually select energy efficiency measures (EEMs) by referring to return on investment (ROI). Current studies tend to apply static energy price to estimate ROI. However, more and more buildings are adopting dynamic electricity pricing programs. To understand how electricity pricing programs impact the selection of EEMs, this paper presents an analysis of the ROIs of EEMs under different pricing programs using U.S. medium office buildings as an example. Eight EEMs in four typical cities are selected as case studies. Considering five electricity pricing programs scenarios (one static program and four dynamic programs), EEMs are selected based on their ROIs. The main findings are: (1) The ROIs of EEMs change under different pricing programs. (2) In Honolulu, Buffalo, and Denver, replacing interior fixtures with higher-efficiency fixtures has a significantly higher ROI than the rest EEMs under all five pricing programs. However, the ROI of this EEM in Honolulu ranges from 28% to 47% for different pricing programs. (3) Similarly, in Fairbanks, replace heating coil with higher-efficiency coil produce higher ROI than the rest under all five pricing programs. (4) For other EEMs, their ROI rankings vary according to electricity pricing programs.

demand response↗

COLUMBUS─An Efficient and General Program Package for Ground and Excited State Computations Including Spin–Orbit Couplings and Dynamics

The COLUMBUS program system provides the tools for performing high-level multireference (MR) computations, including the multireference configuration interaction (MRCI) method and its multireference averaged quadratic coupled cluster (MR-AQCC) extension, allowing computations on a wide range of fascinating atomic and molecular systems, including the treatment of open-shells and complicated excited state phenomena. The inclusion of spin−orbit coupling (SOC) directly within the MRCI step enables the description of systems containing heavy elements, such as lanthanides and actinides, whose properties are strongly influenced by SOC. Analytic energy gradients and nonadiabatic couplings at the correlated MRCI level provide the foundation for a variety of dynamics studies, giving insight into ultrafast photochemistry. New and ongoing method developments in COLUMBUS include the computation of spin densities, improved descriptions of ionic states, enhancements to the AQCC method, and the porting of COLUMBUS to graphical processing units (GPUs). New external interfaces enable an enhanced description of electronic resonances and molecules in strong laser fields. This work highlights these new developments while providing a detailed account of the diverse applications of COLUMBUS in recent years.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

co2amp: A software program for modeling the dynamics of ultrashort pulses in optical systems with CO 2 amplifiers

We describe a computer code for simulating the amplification of ultrashort mid-infrared laser pulses in CO 2 amplifiers and their propagation through arbitrary optical systems. This code is based on a comprehensive model that includes an accurate consideration of the CO 2 active medium and a physical optics propagation algorithm, and takes into account the interaction of the laser pulse with the material of the optical elements. Finally, the application of the code for optimizing an isotopic regenerative amplifier is described.

43 PARTICLE ACCELERATORS↗