Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dyes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Water vapor differential absorption lidar development and evaluation

A ground-based differential absorption lidar (DIAL) system is described which has been developed for vertical range-resolved measurements of water vapor. The laser transmitter consists of a ruby-pumped dye laser, which is operated on a water vapor absorption line at 724.372 nm. Part of the ruby laser output is transmitted simultaneously with the dye laser output to determine atmospheric scattering and attenuation characteristics. The dye and ruby laser backscattered light is collected by a 0.5-m diam telescope, optically separated in the receiver package, and independently detected using photomultiplier tubes. Measurements of vertical water vapor concentration profiles using the DIAL system at night are discussed, and comparisons are made between the water vapor DIAL measurements and data obtained from locally launched rawinsondes. Agreement between these measurements was found to be within the uncertainty of the rawinsonde data to an altitude of 3 km. Theoretical simulations of this measurement were found to give reasonably accurate predictions of the random error of the DIAL measurements. Confidence in these calculations will permit the design of aircraft and Shuttle DIAL systems and experiments using simulation results as the basis for defining lidar system performance requirements

Browell, E. V.↗

Detecting Cracks on Inner Surfaces

Microscopic cracks or flaws in surface of a workpiece are often detected with fluorescent dye. Dye is spread over surface to be inspected and then washed off. When piece is viewed under ultraviolet light, a glow is seen from dye trapped in any flaws. Intensity of fluorescence gives a rough indication of depth of defect. Fluorescent inspection procedure is fast, inexpensive and simple to perform.

Sax, A.↗

Lidar observations of the nighttime sodium layer at 33 deg N

Measurements of the nighttime atmospheric sodium layer have been performed since 1977, using a dye lidar at Fukuoka (33.4 deg N, 130.2 deg E.). The Kyushu lidar uses a flashlamp pumped dye laser tuned to the sodium D sub 2 line (589.0 nm) as a transmitter. The dye laser used in the Kyushu lidar system has been described elsewhere. Sporadic enhancements of the total column abundance of the layer during the Perseids meteor shower were observed on the nights of August 12 and 13, 1978, 1979, 1981, and 1983. Degrading weather conditions prevented observation on the nights during 1980 and 1983. A contour plot of the sodium layer for the period of 8 hours from 21:00 to 5:00 JST on the night of August 12 to 13 1983, is shown. The predominant feature visible is the increase in the height of peak density from 21:00 to 2:00 JST, and the slight decrease in the height of peak density from 2:00 to 5:00 JST. The average abundance had a maximum of about 7 x 10 to the 13th power/sq m on August 13. A plot is presented of the nightly average abundance for available data. The sodium layer abundance increased on the night of August 12 to 13, 1983, during the peak of the Perseids meteor shower, and the following night, August 13 to 14, almost went back to the monthly mean.

Uchiumi, M.↗

Mixing-induced fluid destratification and ullage condensation

In many applications, on-orbit storage and transfer of cryogens will require forced mixing to control tank pressure without direct venting to space. During a no-vent transfer or during operation of a thermodynamic vent system in a cryogen storage tank, pressure control is achieved by circulating cool liquid to the liquid-vapor interface to condense some of the ullage vapor. To measure the pressure and temperature response rates in mixing-induced condensation, an experiment has been developed using Freon 11 to simulate the two-phase behavior of a cryogen. A thin layer at the liquid surface is heated to raise the tank pressure, and then a jet mixer is turned on to circulate the liquid, cool the surface, and reduce the pressure. Many nozzle configurations and flow rates are used. Tank pressure and the temperature profiles in the ullage and the liquid are measured. Initial data from this ground test are shown correlated with normal-gravity and drop-tower dye-mixing data. Pressure collapse times are comparable to the dye-mixing times, whereas the times needed for complete thermal mixing are much longer than the dye-mixing times.

Meserole, Jere S.↗

Photochromic Polyaphrons For Visualization Of Flow

Drops of ultraviolet-activated dyes encapsulated in liquid films reveal flow patterns. Method based on visualization material composed of polyaphrons containing photochromic dye. Polyaphrons are droplets of organic liquid encapsulated in thin layer of another liquid, which holds droplets stably by surface tension. Photochromic dye within a polyaphron acquires color temporarily after exposure to strong ultraviolet light.

Subbaraman, M. R.↗

Picosecond pulse measurements using the active laser medium

A simple method for measuring the pulse lengths of synchronously pumped dye lasers which does not require the use of an external nonlinear medium, such as a doubling crystal or two-photon fluorescence cell, to autocorrelate the pulses is discussed. The technique involves feeding the laser pulses back into the dye jet, thus correlating the output pulses with the intracavity pulses to obtain pulse length signatures in the resulting time-averaged laser power. Experimental measurements were performed using a rhodamine 6G dye laser pumped by a mode-locked frequency-doubled Nd:YAG laser. The results agree well with numerical computations, and the method proves effective in determining lengths of picosecond laser pulses.

Bernardin, James P.↗

An Experimental Method for Measuring Water Droplet Impingement Efficiency on Two- and Three-dimensional Bodies

An experimental method was developed to determine the droplet impingement characteristics on 2-D and 3-D bodies. The experimental results provide the essential droplet impingement data required to validate water droplet trajectory codes, which are used in the analysis of aircraft icing. A body, whose water droplet impingement characteristics are required, is covered at strategic locations by thin strips of moisture absorbing (blotter) paper, and is exposed to an air stream containing a water dye solution spray cloud. Water droplet impingement data are extracted from the dyed blotter strips by measuring the optical reflectance of the dye deposit on the strips, using an automated reflectometer. Models tested include a 4-inch diameter cylinder, a NACA 652015 airfoil section, a MS(1)-0317 supercritical airfoil section, three simulated ice shapes, an axisymmetric inlet and a Boeing 737-300 inlet model. Detailed descriptions of the dye tracer technique, instrumentation, data reduction method and the results obtained are presented. Analytical predictions of collection efficiency characteristics for most test configurations are included for comparison.

Trajectory code validation↗

Penetrant-Indication-Measuring Compass

Modified drafting compass well suited to measurement of length of crack or width of area stained by penetrant-dye-inspection method. Equipped with any of variety of standard curved or straight pointed tips. Modification consists in coating tips with dye that fluoresces light pink under same ultraviolet inspection light causing penetrant dye to fluoresce yellow green. Used in locations inaccessible to conventional fluorescent comparator. Eliminates errors of optical distortion in comparator, also eliminates errors of interpolation.

Schaefer, Lloyd↗

Lidar Measurements of Metallic Species in Mesopause Region

Sodium density distributions were measured over more than 20 nights since Jul. 1991 at Tokyo Metropolitan University. Our sodium lidar specifications are shown. The lidar consists of a dye laser that is pumped by a pulsed Nd:YAG laser. The dye laser is tuned to the D2 resonant absorption line of Na at the wavelength of 589 nm. A small fraction of the output beam is directed to a hollow-cathode lamp. The precise tuning of the Na D2 line is accomplished by monitoring the signal obtained from the hollow-cathode lamp and controlling the grating in the dye laser oscillator cavity. The raw data for each profile were obtained by firing the laser 5000 times for approximately 8.5 minutes. We have observed the sporadic sodium layers three times during the observation period. Recently, lidar measurements of iron atoms were also performed. Other aspects of this investigation are presented.

Nagasawa, Chikao↗

Hair cell tufts and afferent innervation of the bullfrog crista ampullaris

Within the bullfrog semicircular canal crista, hair cell tuft types were defined and mapped with the aid of scanning electron microscopy. Dye-filled planar afferent axons had mean distal axonal diameters of 1.6-4.9 microns, highly branched arbors, and contacted 11-24 hair cells. Dye-filled isthmus afferent axons had mean distal axonal diameters of 1.8-7.9 microns, with either small or large field arbors contacting 4-9 or 25-31 hair cells. The estimated mean number of contacts per innervated hair cell was 2.2 for planar and 1.3 for isthmus afferent neurons. Data on evoked afferent responses were available only for isthmus units that were observed to respond to our microrotational stimuli. Of 21 such afferent neurons, eight were successfully dye-filled. Within this sample, high-gain units had large field arbors and lower-gain units had small field arbors. The sensitivity of each afferent neuron was analyzed in terms of noise equivalent input (NEI), the stimulus amplitude for which the afferent response amplitude is just equivalent to the rms deviation of the instantaneous spike rate. NEI for isthmus units varied from 0.63 to 8.2 deg/s; the mean was 3.2 deg/s.

Myers, Steven F.↗

On the possibility of measuring atmospheric OH using intracavity laser spectroscopy

Intracavity laser spectroscopy (ILS) has been demonstrated to be useful for measuring extremely weak absorption produced by gases in air. ILS is based on the observation that when there are spectrally narrow losses within the cavity of a broadband laser, the laser output has corresponding spectral holes where the laser oscillation is partially quenched. The depth of the laser output dips can be enhanced by a factor of 10(exp 5) over the depth of the initial cavity loss, and absorptivities of 10(exp -8) cm(exp -1) have been measured in lasers only one meter long. With ILS, one can achieve in a compact space a spectral contrast that would otherwise require kilometers of pathlength. ILS systems typically use quasi-continuous wave dye lasers operating close to threshold. The pump laser is modulated from just below to just above the threshold level for the dye laser, and the dye laser output is spectroscopically observed during a well defined time interval after the onset of lasing (the generation time). The spectral contrast of an intracavity absorber is equivalent to that produced by absorption through a path length equal to the generation time multiplied by the speed of light (assuming the cavity is completely filed with the absorber) up to some limiting time. Thus, if one measures the spectrum after 33 microseconds, the effective path length is 10,000 meters.

Mcmanus, J. Barry↗

Simultaneous three-dimensional velocity and mixing measurements by use of laser Doppler velocimetry and fluorescence probes in a water tunnel

A water tunnel investigation was conducted to demonstrate the capabilities of a laser-based instrument that can measure velocity and fluorescence intensity simultaneously. Fluorescence intensity of an excited fluorescent dye is directly related to concentration level and is used to indicate the extent of mixing in flow. This instrument is a three-dimensional laser Doppler velocimeter (LDV) in combination with a fluorometer for measuring fluorescence intensity variations. This capability allows simultaneous flow measurements of the three orthogonal velocity components and mixing within the same region. Two different flows which were generated by two models were studied: a generic nonaxisymmetric nozzle propulsion simulation model with an auxiliary internal water source that generated a jet flow and an axisymmetric forebody model with a circular sector strake that generated a vortex flow. The off-body flow fields around these models were investigated in the Langley 16- by 24-Inch Water Tunnel. The experimental results were used to calculate 17 quantities that included mean and fluctuating velocities, Reynolds stresses, mean and fluctuating dye fluorescence intensities (proportional to concentration), and fluctuating velocity and dye concentration correlations. An uncertainty analysis was performed to establish confidence levels in the experimental results. In general, uncertainties in mean velocities varied between 1 and 7 percent of free-stream velocity; uncertainties in fluctuating velocities varied between 1 and 5 percent of reference values. The results show characteristics that are unique to each type of flow.

Neuhart, Dan H.↗

Feasibility Study of Velocity and Temperature Measurements of an Arcjet Flow using Laser Resonance Doppler Velocimetric (LRDV) Technique

Thermal Protection System (TPS) materials are used in space vehicles to shield from high heating environment encountered during their atmospheric reentry. Arcjet wind tunnels are used to simulate the flowfield encountered by the spacecrafts, and are used for testing TPS materials. How well these tests simulate the actual heating environment encountered by space vehicles depends on the characteristics of the simulated flow. The flow characterization requires the determination of temperature, concentration, and velocity of the various atomic and molecular species present in the flow. However, determining these parameters requires a complex set of both analytical and experimental procedures. The ability to properly simulate the flight environment is directly related to the accuracy with which these techniques can be used to define the arcjet Laser Resonance Doppler Velocimetric (LRDV) technique can be used to accurately determine the velocity and temperature of a gaseous species. In this technique, the medium is probed with a laser beam that is in resonance with an absorbing transition of the species. The absorption lineshape is Doppler-shifted due to the flow velocity of the species, and the frequency shift is detected as the variation in intensity of the fluorescence emitted by the species. Thus a measurement of the Doppler shift and the width of a spectral line can give both the temperature and the velocity of the flowfield. This summer, our project was to make a feasibility study to set up an experimental arrangement for the laser resonance Doppler velocimetric technique using a ring dye laser. Experiments required troubleshooting, cleaning, testing, and alignment of two lasers and several diagnostics instruments. All instruments and lasers necessary for the project worked well, but the output power of the broadband fundamental dye laser was limited to about 20 mW. This was quite low as compared to that necessary to obtain second harmonic oscillation at 327.49 nm for the LRDV studies. Further optimization of the dye laser optical elements is necessary before it can be used for the experiment, which requires narrowband (about 20 Mhz) laser operation.

Rob, Mohammad A.↗

Simultaneous Luminescence Pressure and Temperature Measurement System for Hypersonic Wind Tunnels

Surface pressures and temperatures are determined from visible emission brightness and green-to-red color ratioing of induced luminescence from a ceramic surface with an organic dye coating. A ceramic-dye matrix of porous silica ceramic with an adsorbed dye is developed for high-temperature pressure sensitivity and stability (up to 150 C). Induced luminescence may be excited using a broad range of incident radiation from visible blue light (488-nm wavelength) to the near ultraviolet (365 nm). Ceramic research models and test samples are fabricated using net-form slip-casting and sintering techniques. Methods of preparation and effects of adsorption film thickness on measurement sensitivity are discussed. With the present 8-bit imaging system a 10% pressure measurement uncertainty from 50 to 760 torr is estimated, with an improvement to 5% from 3 to 1500 torr with a 12-bit imaging system.

Buck, Gregory M.↗

Two Wavelength Ti:sapphire Laser for Ozone DIAL Measurements from Aircraft

Laser remote sensing of ozone from aircraft has proven to be a valuable technique for understanding the distribution and dynamics of ozone in the atmosphere. Presently the differential absorption lidar (DIAL) technique, using dual ND:YAG lasers that are doubled to pump dye lasers which in turn are doubled into the UV for the "on" and "off' line lasers, is used on either the NASA DC-8 or P-3 aircraft. Typically, the laser output for each line is 40-mJ and this is split into two beams, one looking up and the other downward, each beam having about 20-mJ. The residual ND:YAG (1.06 micron) and dye laser energies are also transmitted to obtain information on the atmospheric aerosols. While this system has operated well, there are several system characteristics that make the system less than ideal for aircraft operations. The system, which uses separate "on" and "off" line lasers, is quite large and massive requiring valuable aircraft volume and weight. The dye slowly degrades with time requiring replacement. The laser complexity requires a number of technical people to maintain the system performance. There is also the future interest in deploying an ozone DIAL system in an Unpiloted Atmospheric Vehicle (UAV) which would require a total payload mass of less than 150 kg and power requirement of less than 1500 W. A laser technology has emerged that could potentially provide significant enhancements over the present ozone DIAL system. The flashlamp pumped Ti:sapphire laser system is an emerging technology that could reduce the mass and volume over the present system and also provide a system with fewer conversion steps, reducing system complexity. This paper will discuss preliminary results from a flashlamp-pumped Ti:sapphire laser constructed as a radiation source for a UV DIAL system to measure ozone.

Situ, Wen↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗

Multipurpose Fiber Injected-micro-spherical LIDAR System

A technological revolution is occurring in the field of fiber lasers. Over the past two years, the level of power has increased from approx. 100 watts to nearly 1 kilowatt. We are developing a novel fiber laser system, which is a satellite-based LIDAR transmitter of multi-lines. The system is made of a hollow fiber filled with micro-spheres doped with lasing materials. Each sphere has its inherent optical cavity, which makes the system a cavity free and in the same time, emits multi-laser lines for simultaneous multi-task operations. The system is also rugged, compact, lightweight, and durable. Our earlier studies on micro-spheres doped with different laser dyes demonstrated the emission of extremely fine laser lines of less than 3 A line-width, which are of interest for spectroscopic applications, sensing, imaging, and optical communications. Individual dye-doped micro-spheres demonstrated a lasing resonance peaks phenomenon in their fluorescence spectra of linear and nonlinear features that do not exist in the bulk dye solutions. Each individual micro-sphere acts as a laser system with inherent cavity, where the fluorescence line suffers multiple internal reflections within the micro-sphere and gains enough energy to become a laser line. Such resonance peaks are dependent on the sphere's morphology, size, shape, and its refractive index. These resonance peaks are named structural resonance, whispering modes or whispering gallery modes, creeping waves, circumferential waves, surfaces modes, and virtual modes. All of these names refer to the same phenomenon of morphology dependent resonance (MDR), which has already been described and predicted precisely by electromagnetic theory and Lorentz-Mie theory since 1908. The resonance peaks become more obvious when the particle size approaches and exceeds the wavelength of the laser used and the relative index of the particle is greater than that of the surrounding medium. Additional information is included in the original extended abstract.

Abdelayem, Hossin↗

Enhanced Microbial Detection Capabilities by a Rapid Portable Instrument

We present data describing a progression of continuing technology development - from expanding the detection capabilities of the current PTS unit to re-outfitting the instrument with a protein microarray increasing the number of detectable compounds. To illustrate the adaptability of the cartridge format, on-orbit operations data from the ISS demonstrate the detection of the fungal cell wall compound beta-glucan using applicable LOCAD-PTS cartridges. LOCAD-PTS is a handheld device consisting of a spectrophotometer, an onboard pumping mechanism, and data storage capabilities. A suite of interchangeable cartridges lined with four distinct capillaries allow a hydrated sample to mix with necessary reagents in the channels before being pumped to the optical well for spectrophotometric analysis. The reagents housed in one type of cartridge trigger a reaction based on the Limulus Amebocyte Lysate (LAL) assay, which results in the release of paranitroaniline dye. The dye is measured using a 395 nm filter. The LAL assay detects the Gram-negative bacterial cell wall molecule, endotoxin or lipopolysaccharide (LPS). The more dye released, the greater the concentration of endotoxin in the sample. Sampling, quantitative analysis, and data retrieval require less than 20 minutes. This is significantly faster than standard culture-based methods, which require at least a 24 hour incubation period.Using modified cartridges, we demonstrate the detection of Gram negative bacteria with protein microarray technology. Additionally, we provide data from multiple field tests where both standard and advanced PTS technologies were used. These tests investigate the transfer of target microbial molecules from one surface to another. Collectively, these data demonstrate that the new cartridges expand the number of compounds detected by LOCAD-PTS, while maintaining the rapid, in situ analysis characteristic of the instrument. The unit provides relevant data for verifying sterile sample collection protocols, which are critical for conducting accurate scientific experiments during future missions to the Moon and Mars.

Morris, Heather↗