Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “depth data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Geophysical and Environmental Monitoring Data, and Subsurface Flow Modelling Results for Chicken Bone Meadow, Mt. Snodgrass, Crested Butte, CO

This dataset includes geoelectrical monitoring data acquired between October 2021 and November 2022, soil moisture and temperature data, groundwater data obtained from borehole SNIB covering the period from June 2021 to September 2022, and hydrological modelling results. The data were acquired to investigate how variations in bedrock type and topography, and vegetation cover control subsurface flow dynamics. To provide insights into the subsurface flow dynamics and their controls, a monitoring transect was installed at the Chicken Bone Meadow, Mt. Snodgrass, Crested Butte, CO, measuring the spatio-temporal variations of soil moisture, soil and snow temperature, subsurface electrical resistivity variations, and groundwater dynamics. Field data are organized in a folder structure, with Electrical Resistivity Tomography (ERT) data being provided as one file per measurement, and data of the soil moisture and temperature sensors being provided as text files covering the entire monitoring period. The ‘Locations.csv’ file contains the location of all sensors, given in NAD83 – UTM Zone 13N. ERT monitoring data has been processed to filter data based on reciprocal errors (data with errors > 30% were removed), a linear error model was fitted to each survey, and to ensure a constant set of measurements for time-lapse inversion, filtered data were interpolated and assigned a 100% measurement error. Soil moisture and temperature data were acquired at 15 min intervals, and averaged to provide 1h data. Weather data and borehole data (groundwater depth, conductivity and temperature) were acquired at 30 min intervals, and are provided as daily measurements; all measurements are averaged, except of precipitation values, which are given as daily accumulation. The hydrological model was set up along the ERT monitoring transect, and net infiltration was used as surface boundary condition and derived from the weather data. Four different results are provided, (1) results for a parameterization using hydraulic permeability and porosity as derived from the ERT data through petrophysical relationships, and (2) three simplified model results, using 1 to 3 geological layers above the bedrock. Modelling was performed using PFLOTRAN, and for each model the PFLOTRAN input files are provided. The result files include weekly hydrological modelling results (e.g., saturation, velocities, pressures), as well as the model parameterization. The dataset additionally includes a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata; and a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type.

54 ENVIRONMENTAL SCIENCES↗

H i, CO, and Dust in the Perseus Cloud

Comparison analyses between the gas emission data (H I 21 cm line and CO 2.6 mm line) and the Planck/IRAS dust emission data (optical depth at 353 GHz τ{sub 353} and dust temperature T{sub d}) allow us to estimate the amount and distribution of the hydrogen gas more accurately, and our previous studies revealed the existence of a large amount of optically thick H I gas in the solar neighborhood. Referring to this, we discuss the neutral hydrogen gas around the Perseus cloud in the present paper. By using the J-band extinction data, we found that τ{sub 353} increases as a function of the 1.3th power of column number density of the total hydrogen (N{sub H}), and this implies dust evolution in high density regions. This calibrated τ{sub 353}--N{sub H} relationship shows that the amount of the H I gas can be underestimated to be ∼60% if the optically thin H I method is used. Based on this relationship, we calculated the optical depth of the 21 cm line (τ{sub HI}) and found that 〈τ{sub HI}〉∼0.92 around the molecular cloud. The effect of τ{sub HI} is still significant, even if we take into account the dust evolution. We also estimated a spatial distribution of the CO-to-H{sub 2} conversion factor (X{sub CO}), and we found its average value is 〈X{sub CO}〉∼1.0×10{sup 20} cm{sup −2} K{sup −1} km{sup −1} s. Although these results are inconsistent with some previous studies, these discrepancies can be well explained by the difference of the data and analyses methods.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-BRE-15: Verification of Energy Dependence of MAGAT Polymer Gel at Orthovoltage Energies

Purpose: Investigation of dose response curves of methacrylic acid-based “MAGAT” gel at different effective energies to verify an energy dependence of polymer-gel dosimeters for orthovoltage energy x-rays. Methods: Six small cylindrical MAGAT gel phantoms were exposed to different dose levels; one phantom was unirradiated for background subtraction. This experiment was repeated for three different effective beam energies.24 h post irradiation the spin-spin relaxation times (T2) were measured with a 4.7 T Bruker MR scanner at 2 cm depth inside the gel. The T2 values were converted to relaxation rates (R2) and plotted against the respective dose levels corresponding to the different effective energies. The resulting dose response curves were compared for a 250 kVp beam, the 250 kVp beam filtered by 6 cm of water, and a 125 kVp beam. Results: The passage of the 250 kVp beam through water resulted in a half-value-layer (HVL) change from 1.05 mm Cu to 1.32 mm Cu at 6 cm depth with a change in effective energy from 81.3 keV to 89.5 keV, respectively. The dose response curves showed a shift to higher relaxation rates for the harder beam. The dose response measurements for the 125 kVp beam (HVL: 3.13 mm Al, effective energy: 33.9 keV) demonstrated even higher relaxation rates than for either of the other beams. Conclusion: The MAGAT dose response curves for three different effective energies demonstrate a complex energy dependence, with an apparent decrease in sensitivity at 89.5 keV effective energy. This energy dependence is consistent with observed discrepancies of depth dose data compared with ion-chamber data. For future investigations of larger volumes, an energy-dependent sensitivity function is needed to properly assess 3-dimensional dose distributions.

60 APPLIED LIFE SCIENCES↗

Test data analysis of the thermodynamic vent system-augmented top spray injector liquid nitrogen transfer experiments

Traditionally, a cryogenic tank must be pre-chilled to some “target” temperature before the main vent valve can be closed to attempt a non-vented fill (NVF) of cryogenic liquid propellant. This methodology is particularly attractive for performing in-space transfer of cryogens due to the unknown location of the liquid/vapor interface in microgravity and the high likelihood of venting liquid if the vent valve is opened during transfer. This paper presents in-depth test data analysis of a Thermodynamic Vent System (TVS) augmented injector used for cryogenic tank chilldown and fill experiments of a thin-walled Titanium tank. Eight tests were conducted using liquid nitrogen across a range of inlet conditions and boundary conditions, and three different chilldown/fill methods. For four of the tests, the injector sprays liquid into the tank as normal, but also uses a TVS heat exchanger to cool the metallic injector itself as well as the main incoming liquid stream. Results show that using the TVS augmented injector simplifies transfer operation via enhanced condensation at the injector surface at the cost of sacrificing only a small amount of propellant.

No-vent Fill↗

Hydrologic Model Files (PRMS) for Historical Conditions in the East River Watershed, Colorado between 1987-2019

The data package contains model input and output file for the East River watershed (85 km2) located in the headwaters of the Colorado River. The model is the U.S. Geological Survey (USGS) Precipitation-Modeling Runoff System (PRMS) for the historical, or baseline, condition (1987-2019) to assess the efficiency of summer monsoon rains to generate streamflow. The finite difference grid resolution is 100 m with elevations resampled from the USGS National Elevation Dataset. LANDFIRE raster data is used to derive parameters of dominant cover type, summer and winter cover density, canopy interception characteristics for snow and rain and transmission coefficient for shortwave radiation. Climate forcing uses minimum and maximum daily temperature lapse rates defined by the two Snow Telemetry (SNOTEL) stations located in the vicinity of the East River adjusted for aspect. Schofield SNOTEL snowfall is spatially distributed using LiDAR derived snow depth observations from the Airborne Snow Observatory (ASO) flown 4 April 2016. Snow depths are converted to snow water equivalent based on ground surveys and density modeling. Rainfall is spatially distributed using the monthly Parameter-elevation Relationships on Independent Slopes Model 30-year monthly averages. Simulated solar radiation is calibrated to match weather station observations. Model verification of snow water equivalent (SWE) accumulation and ablation relies on the 2018 and 2019 ASO maps and weather station snow depth. The data package contains model input files in text format, model documentation in pfd and a readme.txt file to help users understand the file structure to run the program.

54 ENVIRONMENTAL SCIENCES↗

Determination of cloud optical depth with the multiple field of view sun photometer

An approach to determining cloud optical depth is presented which utilizes a multiple-field-of-view sun photometer, along with modeled behavior of transmittance ratios as a function of the field of view, to infer the optical depth. The data used in the analysis were collected during the FIRE Stratocumulus IFO, which took place from July 15 to 17, 1987. Values which were taken within an hour of local solar noon are presented and compared with the values computed for mu sub 0 = 1.0. The zenith angle for the measurements was between 11 and 18 deg. It is found that this method of inferring the optical depth indicates most clouds with optical depths within these limits. The measured curves have a slightly different shape than do the modeled ratios.

Hein, Paul F.↗

SU-E-T-790: Validation of 4D Measurement-Guided Dose Reconstruction (MGDR) with OCTAVIUS 4D System

Purpose: To validate the MGDR of OCTAVIUS 4D system (PTW, Freiburg, Germany) for quality assurance (QA) of volumetric-modulated arc radiotherapy (VMAT). Methods: 4D-MGDR measurements were divided into two parts: 1) square fields from 2×2 to 25×25 cm{sup 2} at 0°, 10° and 45° gantry, and 2) 8 VMAT plans (5 nasopharyngeal and 3 prostate) collapsed to gantry 40° in QA mode in Monaco v5.0 (Elekta, CMS, Maryland Heights, MO) were delivered on the OCTAVIUS 4D phantom with the OCTAVIUS 1500 detector plane perpendicular to either the incident beam to obtain the reconstructed dose (OCTA4D) or the 0° gantry axis to obtain the raw doses (OCTA3D) in Verisoft 6.1 (PTW, Freiburg, Germany). Raw measurements of OCTA3D were limited to < 45° gantry to avoid >0.5% variation of detector angular response with respect to 0° gantry as determined previously. Reconstructed OCTA4D and raw OCTA3D doses for all plans were compared at the same detector plane using γ criteria of 2% (local dose)/2mm and 3%/3mm criteria. Results: At gantry 0° and 10°, the γ results for all OCTA4D on detector plane coinciding with OCTA3D were over 90% at 2%/2mm except for the largest field (25×25 cm{sup 2} ) showing >88%. For square field at 45° gantry, γ passing rate is > 90% for fields smaller than 15x 15cm2 but < 80% for field size of 20 x20 cm{sup 2} upward. For VMAT, γ results showed 94% and 99% passing rate at 2%/2mm and 3%/3mm, respectively. Conclusion: OCTAVIUS 4D system has compromised accuracy in reconstructing dose away from the central beam axis, possibly due to the off-axis softening correction and errors of the percent depth dose data necessary as input for MGDR. Good results in VMAT delivery suggested that the system is relatively reliable for VMAT with small segments.

60 APPLIED LIFE SCIENCES↗

Risk reduction methodologies and technologies for the Earth Observing System (EOS) Operations Center (EOC)

This paper will discuss proposed Flight Operations methodologies and technologies for the Earth Observing System (EOS) Operations Center (EOC), to reduce risks associated with the operation of complex multi-instrument spacecraft in a multi-spacecraft environment. The EOC goals are to obtain 100 percent science data capture and maintain 100 percent spacecraft health, for each EOS spacecraft. Operations risks to the spacecraft and data loss due to operator command error, mission degradation due to mis-identification of an anomalous trend in component performance or mis-management of resources, and total mission loss due to improper subsystem configuration or mis-identification of an anomalous condition. This paper discusses automation of routine Flight Operations Team (FOT) responsibilities, Expert systems for real-time non-nominal condition decision support, and Telemetry analysis systems for in-depth playback data analysis and trending.

Hudson, Richard K.↗

Seasonal Monitoring and Estimation of Regional Aerosol Distribution over Po Valley, Northern Italy, Using a High-Resolution MAIAC Product

In this work, the new 1-km-resolved Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm is employed to characterize seasonal AOD-PM10 correlations over northern Italy. The accuracy of the new dataset is assessed versus the widely used Moderate Resolution Imaging Spectroradiometer (MODIS) Collection 5.1 Aerosol Optical Depth (AOD) data, retrieved at 0.55 microns with spatial resolution of 10 km (MYD04). We focused on evaluating the ability of these two products to characterize both temporal and spatial distributions of aerosols within urban and suburban areas. Ground PM10 measurements were obtained from 73 of the Italian Regional Agency for Environmental Protection (ARPA) monitoring stations, spread across northern Italy, for a three-year period from 2010 to 2012. The Po Valley area (northern Italy) was chosen as the study domain because of severe urban air pollution, resulting from the highest population and industrial manufacturing density in the country, being located in a valley where two surrounding mountain chains favor the stagnation of pollutants. We found that the global correlations between PM10 and AOD are R(sup 2) = 0.83 and R(sup 2) = 0.44 for MYD04_L2 and for MAIAC, respectively, suggesting for a greater sensitiveness of the high-resolution product to small-scale deviations. However, the introduction of Relative Humidity (RH) and Planetary Boundary Layer (PBL) depth corrections gave a significant improvement to the PM AOD correlation, which led to similar performance: R(sup 2) = 0.96 for MODIS and R(sup 2) = 0.95 for MAIAC. Furthermore, the introduction of the PBL information in the corrected AOD values was found to be crucial in order to capture the clear seasonal cycle shown by measured PM10 values. The study allowed us to define four seasonal linear correlations that estimate PM10 concentrations satisfactorily from the remotely sensed MAIAC AOD retrieval. Overall, the results show that the high resolution provided by MAIAC retrieval data is much more relevant than 10km MODIS data to characterize PM10 in this region of Italy which has a pretty limited geographical domain, but a broad variety of land usages and consequent particulate concentrations.

MODIS↗

Orion Flight Test-1 Thermal Protection System Instrumentation

The Orion Crew Exploration Vehicle (CEV) was originally under development to provide crew transport to the International Space Station after the retirement of the Space Shuttle, and to provide a means for the eventual return of astronauts to the Moon. With the current changes in the future direction of the United States human exploration programs, the focus of the Orion project has shifted to the project s first orbital flight test, designated Orion Flight Test 1 (OFT-1). The OFT-1 is currently planned for launch in July 2013 and will demonstrate the Orion vehicle s capability for performing missions in low Earth orbit (LEO), as well as extensibility beyond LEO for select, critical areas. Among the key flight test objectives are those related to validation of the re-entry aerodynamic and aerothermal environments, and the performance of the thermal protection system (TPS) when exposed to these environments. A specific flight test trajectory has been selected to provide a high energy entry beyond that which would be experienced during a typical low Earth orbit return, given the constraints imposed by the possible launch vehicles. This trajectory resulted from a trade study that considered the relative benefit of conflicting objectives from multiple subsystems, and sought to provide the maximum integrated benefit to the re-entry state-of-the-art. In particular, the trajectory was designed to provide: a significant, measureable radiative heat flux to the windward surface; data on boundary transition from laminar to turbulent flow; and data on catalytic heating overshoot on non-ablating TPS. In order to obtain the necessary flight test data during OFT-1, the vehicle will need to have an adequate quantity of instrumentation. A collection of instrumentation is being developed for integration in the OFT-1 TPS. In part, this instrumentation builds upon the work performed for the Mars Science Laboratory Entry, Descent and Landing Instrument (MEDLI) suite to instrument the OFT-1 ablative heat shield. The MEDLI integrated sensor plugs and pressure sensors will be adapted for compatibility with the Orion TPS design. The sensor plugs will provide in-depth temperature data to support aerothermal and TPS model correlation, and the pressure sensors will provide a flush air data system for validation of the entry and descent aerodynamic environments. In addition, a radiometer design will be matured to measure the radiative component of the reentry heating at two locations on the heat shield. For the back shell, surface thermocouple and pressure port designs will be developed and applied which build upon the heritage of the Space Shuttle Program for instrumentation of reusable surface insulation (RSI) tiles. The quantity and location of the sensors has been determined to balance the needs of the reentry disciplines with the demands of the hardware development, manufacturing and integration. Measurements which provided low relative value and presented significant engineering development effort were, unfortunately, eliminated. The final TPS instrumentation has been optimized to target priority test objectives. The data obtained will serve to provide a better understanding of reentry environments for the Orion capsule design, reduce margins, and potentially reduce TPS mass or provide TPS extensibility for alternative missions.

Kowal, T. John↗

Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams

Purpose: There are currently several commercially available radiotherapy treatment units without a flattening filter in the beam line. Unflattened photon beams have an energy and lateral fluence distribution that is different from conventional beams and, thus, their attenuation properties differ. As a consequence, for flattening filter free (FFF) beams, the relationship between the beam-quality specifier TPR{sub 20,10} and the Spencer–Attix restricted water-to-air mass collision stopping-power ratios, (L{sup -}/ρ){sub air}{sup water}, may have to be refined in order to be used with equivalent accuracy as for beams with a flattening filter. The purpose of this work was twofold. First, to study the relationship between TPR{sub 20,10} and (L{sup -}/ρ){sub air}{sup water} for FFF beams, where the flattening filter has been replaced by a metal plate as in most clinical FFF beams. Second, to investigate the potential of increasing the accuracy in determining (L{sup -}/ρ){sub air}{sup water} by adding another beam-quality metric, TPR{sub 10,5}. The relationship between (L{sup -}/ρ){sub air}{sup water} and %dd(10){sub x} for beams with and without a flattening filter was also included in this study. Methods: A total of 24 realistic photon beams (10 with and 14 without a flattening filter) from three different treatment units have been used to calculate (L{sup -}/ρ){sub air}{sup water}, TPR{sub 20,10}, and TPR{sub 10,5} using the EGSnrc Monte Carlo package. The relationship between (L{sup -}/ρ){sub air}{sup water} and the dual beam-quality specifier TPR{sub 20,10} and TPR{sub 10,5} was described by a simple bilinear equation. The relationship between the photon beam-quality specifier %dd(10){sub x} used in the AAPM’s TG-51 dosimetry protocol and (L{sup -}/ρ){sub air}{sup water} was also investigated for the beams used in this study, by calculating the photon component of the percentage depth dose at 10 cm depth with SSD 100 cm. Results: The calculated (L{sup -}/ρ){sub air}{sup water} for beams without a flattening filter was 0.3% lower, on average, than for beams with a flattening filter and comparable TPR{sub 20,10}. Using the relationship in IAEA, TRS-398 resulted in a root mean square deviation (RMSD) of 0.0028 with a maximum deviation of 0.0043 (0.39%) from Monte Carlo calculated values. For all beams in this study, the RMSD between the proposed model and the Monte Carlo calculated values was 0.0006 with a maximum deviation of 0.0013 (0.1%). Using an earlier proposed relationship [Xiong and Rogers, Med. Phys. 35, 2104–2109 (2008)] between %dd(10){sub x} and (L{sup -}/ρ){sub air}{sup water} gave a RMSD of 0.0018 with a maximum deviation of 0.0029 (0.26%) for all beams in this study (compared to RMSD 0.0015 and a maximum deviation of 0.0048 (0.47%) for the relationship used in AAPM TG-51 published by Almond et al. [Med. Phys. 26, 1847–1870 (1999)]). Conclusions: Using TPR{sub 20,10} as a beam-quality specifier, for the flattening filter free beams used in this study, gave a maximum difference of 0.39% between (L{sup -}/ρ){sub air}{sup water} predicted using IAEA TRS-398 and Monte Carlo calculations. An additional parameter for determining (L{sup -}/ρ){sub air}{sup water} has been presented. This parameter is easy to measure; it requires only an additional dose measurement at 5 cm depth with SSD 95 cm, and provides information for accurate determination of the (L{sup -}/ρ){sub air}{sup water} ratio for beams both with and without a flattening filter at the investigated energies.

07 ISOTOPE AND RADIATION SOURCES↗

EGS Collab Experiment 1: 4850L Downhole Camera Surveys During Injection

This package includes data and footage from two rounds of downhole camera surveys performed at the Sanford Underground Research Facility (SURF) on the 4850 level. The exercise was performed once on 25 May 2018 and once on 21 December 2018. On May 25th, the first round was done during fluid injection at the 164-ft stimulation zone in the injection well (E1-I). On December 21st, the second round was carried out during fluid injection at the 142-ft stimulation zone. Prior to the injections, downhole instrumentation was removed from the production well (E1-P) to allow room for the downhole camera system. The water within E1-P was then lifted out by the application of air pressure and the downhole camera system was conveyed into the production well. Finally, the water was injected into E1-I and the camera was used to scan for jetting points, or fluid entry, in E1-P. There is a survey description in this package that further describes the procedure of the survey and the overall results. Additionally, there is a detailed analysis of the surveys in the form of a PowerPoint, which includes animations/visualizations from the camera footage, presents interpretations in detail, and provides some general conclusions. Three animations, along with the two video segments that show the jetting into E1-P, are also provided. The video footage was collected using a GeoVISION Dual-Scan Micro Video Camera, the specs of which are also included in this package as a resource.

15 GEOTHERMAL ENERGY↗

SU-E-T-191: Commissioning and Dosimetric Characteristics of Elekta Agility for Total Skin Electron Beam (TSEB) Therapy

Purpose The purpose of this work is to publish beam data from Elekta Synergy(R) linear accelerators with Agility(TM) MLC for total skin electron beam (TSEB) therapy using the HDRE1 (High Dose Rate Electron 6MeV) energy. Method & Materials The optimal gantry angles for TSEB were determined using ion chamber measurements along a vertical profile at 450cm SSD. After gantry angles were chosen, field uniformity was measured over the entire treatment area. Uniformity was measured with and without the patient support device, allowing the dosimetric effect of the support device to be determined. Beam output and PDD were measured at the calibration point (450cm SSD) for a dual beam using a parallel plate chamber in solid water. These measurements were repeated with the chamber and phantom rotated about the patient isocenter at various angles, in order to measure the contribution from oblique beams. This technique provides a precise measurement of the treatment skin dose (TSD). Lastly, ion chamber measurements were verified by film and diodes. Results The optimal gantry angle for 450 cm SSD was determined to be 90±16°. This achieved uniformity better than 96% on the vertical axis, and 92% along the horizontal axis. HDRE1 was calibrated to deliver 10 cGy/MU at standard geometry (100 cm SSD, 1.2 cm depth). Thus at TSEB geometry (450 cm SSD, 0.1 cm depth) the output of the AP dual field was measured to be 0.35 cGy/MU. The TSD of a 20 cm radius cylinder for six (equally, 60° spaced) dual fields was measured to be 1.19 cGy/MU. Percent Depth Dose data for the AP dual field and TSD are shown in Figure 2. Conclusion This paper provides a modern procedure for commissioning TSEB therapy on a linear accelerator, and clinical beam data for the Elekta Synergy(R) with Agility(TM) MLC.

60 APPLIED LIFE SCIENCES↗

Dissolved pyrogenic carbon leaching in soil: Effects of soil depth and pyrolysis temperature

We report Pyrogenic organic carbon (PyC) is found in soils as a heterogeneous mixture of thermally altered plant residues that range in their susceptibility to losses via mineralization, leaching, and erosion. Leaching of PyC as DOC (DPyC) within the soil profile is likely influenced by the chemical composition of solid PyC and the dominant soil processes and properties at a particular depth. Here we report the results of a 2-year laboratory decomposition and leaching study designed to investigate the interactive effects of pyrolysis temperature levels (no pyrolysis, 300 °C, and 450 °C) and soil depth (surface soil, 0–10 cm depth; subsurface soil, 50–70 cm depth) on losses of 13 C-labeled jack pine (Pinus banksiana) wood, wood pyrolyzed at 300 °C (PyC300) and wood pyrolyzed at 450 °C (PyC450) as dissolved organic carbon (DOC). Losses of wood and PyC in the 13 C- DOC pool were measured in leachates drained from soils once a month over the course of 1 year, and at one single leaching event after 2 years. We found that pyrolysis temperature levels interacted with time and soil depth to affect losses of wood and PyC as DOC throughout the 1-year incubation and leaching study, with greater DOC losses from wood in surface soil (0.73 ± 0.076% of added C) than in subsurface soil (0.40 ± 0.063% of added C) averaged across sampling time. Monthly DOC losses from PyC were not affected by soil depth. Cumulative data indicated a small contribution of wood (2.86 ± 0.07%), PyC300 (0.40 ± 0.04%), and PyC450 (0.16 ± 0.01%) to total DOC leached from soils. DOC losses from wood and PyC300 (as a proportion of added C) were greater in surface soil than in subsurface soil, whereas DOC losses from PyC450 were unaffected by differences between surface and subsurface soil. Losses of DOC were greater from PyC300 than from PyC450 in surface soil, with no significant differences in DOC losses between PyC300 and PyC450 in subsurface soil. One single leaching event at the end of the 2-year decomposition study resulted in higher DOC losses from wood in subsurface soil than in surface soil likely due to desorption, and no differences in DOC losses between PyC300 and PyC450 regardless of soil depth. Our results suggest strong interactions between the initial physicochemical composition of organic C inputs and soil properties (soil depth as a proxy) that control the mobility and transport of PyC and should be better represented in Earth system models.

54 ENVIRONMENTAL SCIENCES↗

16s Amplicon Analysis of Soil Data for Interactive effects of depth and differential irrigation on soil microbiome composition and functioning

Genomic DNA was isolated from soil and rhizosphere samples using the Zymo Quick-DNA fecal/soil microbe miniprep kit (catalog no. D6010) according to the manufacturer’s instructions (Zymo Research; Irvine, CA) with the modification of eluting in 100 uL elution buffer. Sample concentrations were quantified using the Qubit dsDNA HS assay kit (Thermo Fisher). For rhizosphere samples only, DNA was subsequently purified using Zymo’s ZR-96 DNA Clean & Concentrator kit (catalog no. D4024) to account for low DNA concentrations of these samples. . In each replicate block, there were five drip irrigation treatments (T1 = 100% normal irrigation, T2 = 56.25%, T3 = 37.5%, T4 = 18.75% and T5=no irrigation. On July 20, the strength of the drought treatments was increased: T1 remained at 100%, whereas T2 changed from 75% to 56.25%, T2 changed from 50% to 37.5%, and T4 changed from 25% to 18.75%. Sequencing was performed as described previously (Naylor, Fansler, et al. 2020). Sequences were amplified on the MiSeq platform (Illumina, San Diego, CA) using 16S primers (515F and 806R) specific to the V4 region. Raw sequence data was processed with the pipeline Hundo for amplicon quality control and annotation. Downstream statistical analyses on 16S datasets were performed using the program R and the packages ‘phyloseq’ and ‘vegan’.

Soil microbiome, metatranscriptomics↗

MISR Level 2 Aerosol parameters (MIL2ASAE_V2)

The Aerosol data contain aerosol optical depth, aerosol physical model, ancillary meteorological data, and related parameters. The aerosol data include tropospheric aerosol optical depth, Angstrom exponent and single scattering albedo on 17.6 km centers, aerosol mixture identifier and retrieval residuals, and ancillary data including assumed ozone optical depth and retrieval flags. For complete information about the aerosol mixtures, the user will need to order the MISR Aerosol Climatology Product (MIANACP) to obtain Aerosol Physical and Optical Properties (APOP) and the Mixture files. The Mixture files list up to 3 component models used in each mixture, with their relative compositional fractions, and includes ancillary information such as single scattering albedo. The APOP gives detailed information for the component particle models. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1.1 km - 17.6 km; Longitude_Resolution=1.1 km - 17.6 km; Horizontal_Resolution_Range=1 km - < 10 km or approximately .01 degree - < .09 degree; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=Daily - < Weekly, Daily - < Weekly].

EOSDIS↗

MISR Level 2 Aerosol parameters (MIL2ASAE_V1)

The Aerosol data contain aerosol optical depth, aerosol physical model, ancillary meteorological data, and related parameters. The aerosol data include tropospheric aerosol optical depth, Angstrom exponent and single scattering albedo on 17.6 km centers, aerosol mixture identifier and retrieval residuals, and ancillary data including assumed ozone optical depth and retrieval flags. For complete information about the aerosol mixtures, the user will need to order the MISR Aerosol Climatology Product (MIANACP) to obtain Aerosol Physical and Optical Properties (APOP) and the Mixture files. The Mixture files list up to 3 component models used in each mixture, with their relative compositional fractions, and includes ancillary information such as single scattering albedo. The APOP gives detailed information for the component particle models. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1.1 km - 17.6 km; Longitude_Resolution=1.1 km - 17.6 km; Horizontal_Resolution_Range=1 km - < 10 km or approximately .01 degree - < .09 degree; Temporal_Resolution=about 15 orbits/day].

CIRRUS OPTICAL DEPTH↗

SPRUCE Climate Warming and Elevated CO2 Rapidly Alter Peatland Soil Carbon Sources and Stability: Supporting Data

This data set reports a suite of complementary biogeochemical analyses of peat samples from the SPRUCE (Spruce and Peatland Responses Under Changing Environments) experiment. Results were collected using quantitative molecular analysis of bulk soil carbon to assess the stability of soil organic carbon following whole-ecosystem warming and exposure to elevated carbon dioxide concentrations (eCO2). Targeted soil organic carbon components include solvent-extractable compounds (alkanoic acids, alkanols, alkanes, steroids, and terpenoids), ester-bound hydrolysable biopolymers (cutin and suberin markers), lignin phenols, and pyrogenic carbon. Bulk peat samples were analysed by Soxhlet extraction and solid phase separation for solvent-extractable compounds, alkaline hydrolysis to extract hydrolysable biopolymers, copper (II) oxide oxidation to extract lignin phenols and benzene polycarboxylic acids (BPCAs) as an approximation of pyrogenic carbon. Samples were analysed by gas chromatography (GC) equipped with a flame ionization detector (GC-FID) and compound identification was performed on GC coupled to mass selective detector (MS) for solvent-extractable compounds, ester-bound hydrolysable biopolymers and lignin phenols, and high-performance liquid chromatograph (HPLC) for pyrogenic carbon. Results are presented in Ofiti et al. (accepted). The experimental work was conducted on samples collected in August 2018 at the SPRUCE climate manipulation experiment in northern Minnesota, 40 km north of Grand Rapids, in the USDA Forest Service Marcell Experimental Forest (MEF). Samples were collected and later analysed in a 10 cm increments over 0 to 50 cm depth and 25 cm intervals from 50 to 75 cm. Samples were analyzed for lignin phenols over 0 to 30 cm depth. This data set contains one file in comma separate (*.csv) format. This dataset contains data used to produce: Ofiti, N.O.E., Schmidt, M.W.I., Abiven, S., Hanson, P.J., Iversen, C.M., Wilson, R.M., Kostka, J.E., Wiesenberg, G.L.B., Malhotra, A. 2023. Climate warming and elevated CO2 rapidly alter peatland soil carbon sources and stability. Nat Commun 14, 7533. https://doi.org/10.1038/s41467-023-43410-z.

SPRUCE experiment, Marcell Experimental Forest, so↗