Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “density measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Acoustic device and method for measuring gas densities

Density measurements can be made in a gas contained in a flow through enclosure by measuring the sound pressure level at a receiver or microphone located near a dipole sound source which is driven at constant velocity amplitude at low frequencies. Analytical results, which are provided in terms of geometrical parameters, wave numbers, and sound source type for systems of this invention, agree well with published data. The relatively simple designs feature a transmitter transducer at the closed end of a small tube and a receiver transducer on the circumference of the small tube located a small distance away from the transmitter. The transmitter should be a dipole operated at low frequency with the kL value preferable less that about 0.3.

Shakkottai, Parthasarathy↗

Structural Fluctuations and Thermophysical Properties of Molten II-VI Compounds

Recently, in support of the microgravity experiment entitled "Crystal Growth of Selected 11-VI Semiconducting Alloys by Directional Solidification," the viscosity of HgZnTe pseudobinary melt was measured using an oscillating-cup viscometer at NASA/Marshall Space Flight Center (MSFC). An unexpected time drift of the measured viscosity, which shows a slow relaxation phenomena at temperatures near the liquidus point, was reproducibly observed. Two sets of data were obtained by cooling the Hg(0.84)Zn(0.16)Te melt from 850 C and stabilizing at temperatures of 790 C, which is just above the liquidus temperature, and stabilizing at temperature of 810 C. While it took one day to reach equilibration at 810 C, five days were required at 790 C A similar relaxation phenomenon was also observed in the measured density of the same liquid. Furthermore, in the density measurements of the HgCdTe melts, which is the pseudobinary system studied in another flight experiment entitled "Growth of Solid Solution Single Crystals," a negative thermal expansion was reported. The liquid density increases from the liquidus point to a maximum value at a temperature approximately 700 C above the liquidus, where normal thermal expansion progressively resumes.

Su, Ching-Hua↗

Transonic flow past an airfoil with condensation

In connection with investigations conducted to determine the influence of water vapor on experiments in wind tunnels, the question arose as to what changes due to vapor condensation might be expected in airfoil measurements. Density measurements on circular-arc airfoils aided by an interferometer in choked tunnels with parallel walls show that increasing humidity produces increasing changes in the flow field. The flow becomes nonstationary at high humidity. At the airfoil, however, the influence of the condensation is only felt, inasmuch as the shock bounding the local supersonic region moves upstream with increasing humidity while its intensity decreases. The density distribution upstream of the shock remains unchanged. Even if the flow becomes nonstationary in the vicinity of the airfoil, no changes occur at the airfoil.

Schmidt, B.↗

An imaging refractometer for density fluctuation measurements in high energy density plasmas

In this work, we report on a recently developed laser-probing diagnostic which allows direct measurements of ray-deflection angles in one axis, whilst retaining imaging capabilities in the other axis. This allows us to measure the spectrum of angular deflections from a laser beam which passes though a turbulent high-energy-density plasma. This spectrum contains information about the density fluctuations within the plasma, which deflect the probing laser over a range of angles. We create synthetic diagnostics using ray-tracing to compare this new diagnostic with standard shadowgraphy and schlieren imaging approaches, which demonstrates the enhanced sensitivity of this new diagnostic over standard techniques. We present experimental data from turbulence behind a reverse shock in a plasma and demonstrate that this technique can measure angular deflections between 0.06 and 34 mrad, corresponding to a dynamic range of over 500.

47 OTHER INSTRUMENTATION↗

Measurement of the transverse energy density in Measurement of the transverse energy density in Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV with the sPHENIX detector

Here, this paper reports measurements of the transverse energy per unit pseudorapidity (𝑑⁢𝐸 𝑇 /𝑑⁢𝜂) produced in Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV, performed with the sPHENIX detector at the Relativistic Heavy Ion Collider (RHIC). The results cover the pseudorapidity range |𝜂| < 1.1 and constitute the first such measurement performed using a hadronic calorimeter at RHIC. Measurements of 𝑑⁢𝐸 𝑇 /𝑑⁢𝜂 are presented for a range of centrality intervals and the average 𝑑⁢𝐸 𝑇 /𝑑⁢𝜂 as a function of the number of participating nucleons, 𝑁 part , is compared to a variety of Monte Carlo heavy-ion event generators. The results are in agreement with previous measurements at RHIC, and feature an improved granularity in 𝜂 and improved precision in low-𝑁 part events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dual-Line Detection Rayleigh Scattering Measurements of Density and Temperature

Measurements of the laser Rayleigh scattering signal in a flow to determine density and temperature have been commonly employed in open flames and in wind tunnel environments. In these measurements, the density or reciprocal temperature is correlated with the Rayleigh scattering signal intensity. A major advantage of Rayleigh scattering for these applications is the simple experimental arrangement allowed by this technique. Intensity-based Rayleigh scattering measurements of density and temperature have been limited to relatively clean flows in open environments so that interference from particle scattering and laser scattering is minimal. A new approach, using dual-line detection Rayleigh (DLDR) scattering extends the applicability of Rayleigh scattering measurements of density and temperature to enclosed environments where surface scattering interference is high. Depending on particle size and optical properties, this approach may also reduce interference from particle scattering.

Annen, Kurt↗