At least 217 records · Page 12

Using photoelectron spectroscopy to measure resonant inelastic X-ray scattering: a computational investigation

Resonant inelastic X-ray scattering (RIXS) has become an important scientific tool. Nonetheless, conventional high-resolution (few hundred meV or less) RIXS measurements, especially in the soft X-ray range, require low-throughput grating spectrometers, which limits measurement accuracy. Here, the performance of a different method for measuring RIXS, i.e. photoelectron spectrometry for analysis of X-rays (PAX), is computationally investigated. This method transforms the X-ray measurement problem of RIXS to an electron measurement problem, enabling use of high-throughput, compact electron spectrometers. X-rays to be measured are incident on a converter material and the energy distribution of the resultant photoelectrons, the PAX spectrum, is measured with an electron spectrometer. A deconvolution algorithm for analysis of such PAX data is proposed. It is shown that the deconvolution algorithm works well on data recorded with ~0.5 eV resolution. Additional simulations show the potential of PAX for estimation of RIXS features with smaller widths. For simulations using the 3d levels of Ag as a converter material, and with 10 5 simulated detected electrons, it is estimated that features with a few hundred meV width can be accurately estimated in a model RIXS spectrum. For simulations using a sharp Fermi edge to encode RIXS spectra, it is estimated that one can accurately distinguish 100 meV FWHM peaks separated by 45 meV with 10 5 simulated detected electrons that were photoemitted from within 0.4 eV of the Fermi level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward Relating Open- and Closed-Test Section Microphone Phased Array Aeroacoustic Measurements

Aeroacoustic measurements utilizing microphone phased arrays are becoming more commonplace in large-scale wind tunnels. However, for such costly tests it is difficult to assess the influence of a given facility's configuration on the acquired data. One such opportunity has recently arisen in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel, where the High-Lift configuration of the Common Research Model was tested in both open-jet and closed wall configurations. Acoustic data were acquired on the same model with the same specific hardware at the same Mach number; and for similar model angles of attack, array apertures, and array angles relative to the model location. Initial deconvolution comparisons using DAMAS appear poor. The closed test section results show contamination likely due to background noise and reflections. The open-jet results show severe blurring due to the decorrelation of acoustic waves passing through a turbulent free shear layer. However, accounting for image sources in the DAMAS grid reduces visual artifacts in the closed test section results, and a preliminary coherence correction technique mitigates the blurring in the open-jet results. Qualitatively, both tests identify similar source behavior. Quantitatively, summed spectra of the slat noise agree in some frequency bands but differ in others. Proposals that may mitigate the difference are given for each configuration, such as correcting for the array protective cover and applying background subtraction in the closed wall configuration, and further developing the coherence loss correction for deconvolution methods in the open-jet setup.

microphone array↗

Single-Filament Imaging Mass Spectrometry Lipidomics in Arthrospira platensis

Elucidating intra-organismal biochemical and lipid organization in photosynthetic biological cell factories of filamentous cyanobacteria, i.e., Arthrospira platensis (Spirulina), is important to track physiological response mechanisms during growth. Little is known about the filaments' biochemical organization and cellular structure and no label-free imaging techniques exist that provide molecular mapping. We applied ultra-high resolution mass spectrometry (7T FT-ICR-MS) matrix-assisted laser desorption ionization (MALDI) imaging to immobilized Spirulina filaments to investigate the localization of lipids across distinct physiological regions. We optimized matrix selection and deposition methods with the goal of facilitating high spatial, and intra-filament, resolution using untargeted multivariate statistical spectral deconvolution across MS pixels. Our results demonstrate an improved two step application with an optimized procedure for intra-organismal lipid profiling to improve analyte sensitivity and achieve higher spatial resolution, whereby we evaluate three conventional matrices 2,5-dihydroxybenzoic acid (DHB), a 9:1 ratio of DHB:superDHB (sDHB), 1,5- diaminonaphthalene (DAN) and a 50:50 mix of DHB:sDHB and compare delineation and pixel-based elucidation of intra-filament lipidomics. We identified a total of 1,626 features that could be putatively assigned a lipid-like formula based on database query and 46 unique features, with associated lipid assignments that were significantly distinct in their intra-filament location. MALDI- imaging MS with untargeted statistical spectral deconvolution was used to visualize intra-filament lipidomics organization in Spirulina filaments. Improvements in matrix deposition, including sequential sublimation and pneumatic spraying, increased signal abundance at high spatial resolution and allowed for identification of distinct lipid composition regions. Here in this work outlines a methodology that may be used for micro-ecological untargeted molecular phenotyping.

09 BIOMASS FUELS↗

Degradation of electrical resistivity of tungsten following shielded neutron irradiation

A major challenge for heat transfer in nuclear materials is to ensure thermal mobility after high amounts of neutron irradiation. Tungsten is widely selected as a heat transfer material in fusion reactors. In metals, thermal conductivity is dominated by electrons’ ability to transfer energy. Neutron irradiation generates point defects, clusters, and solid transmutation (e.g.rhenium and osmium in tungsten), which inhibit electron motion. The purpose of this work is to quantify the irradiation-induced change in electron mobility and deconvolute transmutation and microstructural effects on observed changes to electron mobility. Single and polycrystalline tungsten were fast neutron irradiated in the High Flux Isotope Reactor at Oak Ridge National Laboratory to doses between 0.2 and 0.7 displacements per atom (dpa) and temperatures from 500 °C to 1000 °C. Grain growth was observed in all samples. Microstructure and transmutation were quantified. The geometric orientation of samples with elongated grains has been shown to affect electrical resistivity. A mathematical model was developed and used to deconvolute solid-solution transmutation, grain, and temperature-dependent lattice effects on resistivity. At ~0.4 dpa at ~590 °C, the combined resistivity degradation due to voids, vacancies, interstitials, and dislocations is estimated to be greater than the contribution from solid solution Re transmutation, which is greater than the contribution from grain boundaries. At doses of ~0.7 dpa at ~750 °C, solid solution Re contributions are greater than all other effects combined. As a result, this work establishes a basis to predict the effects of irradiation temperature and transmutation on thermal properties of tungsten and highlights the importance of irradiation temperature.

36 MATERIALS SCIENCE↗

Effects of micrometer-scale surface roughness on thermal infrared emittance spectra of silica glass

Surface roughness is known to decrease thermal infrared (TIR) absorption band intensity, but studies of the effect on geologically relevant samples are relatively limited. To determine the effect of surface roughness (with features smaller than ~2/3 of the wavelength) on TIR spectra, we investigated two glass compositions with prepared roughened surfaces: (1) high purity fused silica and (2) soda-lime glass (73 wt% SiO$_2$). We roughened the surfaces of the glasses by sandblasting and polishing with grit paper. The surfaces were characterized with scanning electron microscopy and stylus profilometry. We then analyzed the roughened glasses with TIR emittance spectroscopy. Micrometer-scale roughness causes a decrease in TIR absorption band intensity, relative to a specular surface. No significant changes in band shape or shifts in wavelength were detected. As roughness increases, empirical results show a logarithmic decrease in TIR absorption band intensity. The logarithmic trends of the two glass compositions are different; empirical roughness calibrations do not translate across different compositions. A linear, least-squares spectral deconvolution using two endmembers, specular and blackbody, predicts model spectra of roughened glass surfaces with relatively low error. This is of consequence to orbital TIR measurements of poorly constrained targets, such as the martian surface, because micrometer-scale roughness is adequately modeled by the addition of a blackbody spectrum to the deconvolution endmember matrix.

36 MATERIALS SCIENCE↗

High-Field One-Dimensional and Two-Dimensional 27Al Magic-Angle Spinning Nuclear Magnetic Resonance Study of ?-, d-, and ?-Al2O3 Dominated Aluminum Oxides: Toward Understanding the Al Sites in ?-Al2O3

Herein, a detailed analysis was carried out using high-field (19.9 T) 27Al magic-angle spinning (MAS) nuclear magnetic resonance (NMR) on three specially prepared aluminum oxide samples where the ?-, d-, and ?-Al2O3 phases are dominantly expressed through careful control of the synthesis conditions. Specifically, two-dimensional (2D) multiquantum (MQ) MAS 27Al was used to obtain high spectral resolution, which provided a guide for analyzing quantitative 1D 27Al NMR spectra. Six aluminum sites were resolved in the 2D MQ MAS NMR spectra, and seven aluminum sites were required to fit the 1D spectra. A set of octahedral and tetrahedral peaks with well-defined quadrupolar line shapes was observed in the ?-phase dominant sample and was unambiguously assigned to the ?-Al2O3 phase. The distinct line shapes related to the ?-Al2O3 phase provided an opportunity for effectively deconvoluting the more complex spectrum obtained from the d-Al2O3 dominant sample, allowing the peaks/quadrupolar parameters related to the d-Al2O3 phase to be extracted. The results show that the d-Al2O3 phase contains three distinct AlO sites and three distinct AlT sites. This detailed Al site structural information offers a powerful way of analyzing the most complex ?-Al2O3 spectrum. It is found that the ?-Al2O3 phase consists of Al sites with local structures similar to those found in the d-Al2O3 and ?-Al2O3 phases albeit with less ordering. Spin–lattice relaxation time measurement further confirms the disordering of the lattice. Collectively, this study uniquely assigns 27Al features in transition aluminas, offering a simplified method to quantify complex mixtures of aluminum sites in transition alumina samples.

Xu, Suochang↗

Laue-DIALS: Open-source software for polychromatic x-ray diffraction data

Most x-ray sources are inherently polychromatic. Polychromatic (“pink”) x-rays provide an efficient way to conduct diffraction experiments as many more photons can be used and large regions of reciprocal space can be probed without sample rotation during exposure—ideal conditions for time-resolved applications. Analysis of such data is complicated, however, causing most x-ray facilities to discard >99% of x-ray photons to obtain monochromatic data. Key challenges in analyzing polychromatic diffraction data include lattice searching, indexing and wavelength assignment, correction of measured intensities for wavelength-dependent effects, and deconvolution of harmonics. We recently described an algorithm, Careless, that can perform harmonic deconvolution and correct measured intensities for variation in wavelength when presented with integrated diffraction intensities and assigned wavelengths. Here, we present Laue-DIALS, an open-source software pipeline that indexes and integrates polychromatic diffraction data. Laue-DIALS is based on the dxtbx toolbox, which supports the DIALS software commonly used to process monochromatic data. As such, Laue-DIALS provides many of the same advantages: an open-source, modular, and extensible architecture, providing a robust basis for future development. We present benchmark results showing that Laue-DIALS, together with Careless, provides a suitable approach to the analysis of polychromatic diffraction data, including for time-resolved applications.

97 MATHEMATICS AND COMPUTING↗

Searching for correlations between vibrational spectral features and structural parameters of silicate glass network

Infrared (IR) and Raman spectroscopic features of silicate glasses are usually interpreted based on the analogy with those of smaller molecules, molecular clusters, or crystalline counterparts; this study tests the accuracy and validity of these widely cited peak assignment schemes by comparing vibrational spectral features with bond parameters of the glass network created by molecular dynamics (MD) simulations. A series of sodium silicate glasses with compositions of [Na 2 O] x [Al 2 O 3 ] 2 [SiO 2 ] 98- x with x = 7, 12, 17, and 22 were synthesized and analyzed with IR and Raman. A silica glass substrate and a crystalline quartz were also analyzed for comparison. Glass structures with the same compositions were generated with MD simulations using three types of potentials: fixed partial charge pairwise (Teter), partial diffuse charge potential (MGFF), and bond order-based charge transfer potential (ReaxFF). The comparison of simulated and experimental IR spectra showed that, among these three potentials tested, ReaxFF reproduces the concentration dependence of spectral features closest to the experimentally observed trend. Hence, the bond length and angle distributions as well as Si– Q n species and ring size distributions of silica and sodium silicate glasses were obtained from ReaxFF-MD simulations and further compared with the peak assignment or deconvolution schemes—which have been widely used since 1970s and 1980s—(a) correlation between the IR peak position in the Si–O stretch region (1050-1120 cm -1 ) and the Si–O–Si bond angle; (b) deconvolution of the Raman bands in the Si–O stretch region with the Q n speciation; and (c) assignment of the Raman bands in the 420-600 cm -1 region to the bending modes of (SiO) n rings with different sizes (typically, n = 3-6). The comparisons showed that none of these widely used methods is congruent with the bond parameters or structures of silicate glass networks produced via ReaxFF-MD simulations. This result invokes that the adequacy of these spectral interpretation methods must be questioned. Alternative interpretations are proposed, which are to be tested independently in future studies.

36 MATERIALS SCIENCE↗

Practical considerations in using a binary pseudorandom array for instrument transfer function calibration

Binary pseudo-random array (BPRA) artifacts are useful devices for calibrating the instrument transfer function (ITF) of interferometric microscopes and other optical and non-optical surface and wavefront measurement instruments. The intrinsic white noise character of the power spectral density function of the artifact simplifies the deconvolution of the ITF from the measured power spectral density (PSD). However, resampling of the BPRA intrinsic artifact features with the measurement tool's specific sampling pattern modifies the white noise character of the intrinsic spectrum and needs to be accounted for in the ITF-based data deconvolution process. We have developed an analytic solution to the spectrum of a resampled one- and two- dimensional BPRA. The resultant nominal PSD function is a simple twoparameter cosine function with a period equal to the resampled pixel width. A transfer function model for interferometric microscopes that incorporates this function, along with an ITF that includes aliasing effects and variable numerical aperture (NA), wavelength, and obscuration factor, is used to fit to the BPRA PSDs measured by an interference microscope for a range of objective and zoom lens magnification combinations.

Takacs, PZ↗

Multi-Scale Modeling of Hydrogen Transport in a Porous Fuel Cell Anode

Proton-exchange-membrane fuel cells (PEMFC) are a clean energy conversion alternative to traditional fossil-fuel combustion; however, transport resistances in the electrode pose a lower-limit to catalyst loading and commercialization of PEMFCs. PEMFCs consist of simultaneous hydrogen (H 2 ) oxidation and oxygen (O 2 ) reduction at the anode and cathode, respectively. Here, while oxygen transport resistances in PEMFCs have been widely studied both experimentally and analytically, hydrogen transport resistances are less understood. Herein, we present a physics-based model that encompasses multi-scale transport within the anode side of the PEMFC. The O 2 in the cathode here is omitted and replaced with H 2 to deconvolute O 2 transport resistance contributions, similar to that of a hydrogen pump. Replication of the hydrogen pump setup allows for comparison of the model against experimental analysis of H 2 gas-transport resistance in H 2 limiting-current experiments, which can also inform gas transport (including oxygen) in general. Herein, we present a multi-scale analytical model of the porous anode catalyst layers and individual catalyst agglomerates that enables determination of the effects of electrode morphology such as agglomerate size, catalyst loading, etc. on H 2 transport resistance through the porous electrode to complement and better understand H 2 limiting current experiments and deconvolute local H 2 transport resistances.

Zhang, Rosa↗

Environmental Molecular Network (ENVnet) v1

Here, we present an approach that integrates mass difference based deconvolution with molecular networking to build a static reference network from all publicly available organic matter metabolomics datasets. This is accomplished using MS/MS deconvolution coupled with both recently reported (BUDDY) and novel machine learning algorithms to determine chemical formulas and perform MS/MS alignments (REM-BLINK).

Bowen, Benjamin↗

STM/S Grid LDOS Data and Analysis Code for Deciphering Majorana Zero Modes in Topological Superconductor

This dataset provides raw millikelvin scanning tunneling microscopy/spectroscopy (STM/S) grid spectroscopy data and Python analysis scripts supporting the manuscript “Deciphering Majorana Zero Modes in Topological Superconductor FeTe0.55Se0.45 with Machine-Learning-Assisted Spectral Deconvolution.” The dataset includes a raw grid spectroscopy file acquired on FeTe0.55Se0.45 at 40 mK under magnetic field, together with Python/Jupytext analysis scripts used for STM/S data processing, visualization, spectral deconvolution, Lorentzian peak fitting, feature extraction, machine-learning-assisted clustering, and figure generation. These files support the analysis of vortex-core local density of states and the identification of zero-bias-peak-related spectral components from complex in-gap states. The dataset is intended to provide a citable archival record of the data and analysis code associated with the published manuscript and to support transparency and reproducibility of the reported STM/S and machine-learning workflow.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Super-resolution computational saturated absorption microscopy

Imaging beyond the diffraction limit barrier has attracted wide attention due to the ability to resolve previously hidden image features. Of the various super-resolution microscopy techniques available, a particularly simple method called saturated excitation microscopy (SAX) requires only simple modification of a laser scanning microscope: The illumination beam power is sinusoidally modulated and driven into saturation. SAX images are extracted from the harmonics of the modulation frequency and exhibit improved spatial resolution. Unfortunately, this elegant strategy is hindered by the incursion of shot noise that prevents high-resolution imaging in many realistic scenarios. Here, we demonstrate a technique for super-resolution imaging that we call computational saturated absorption (CSA) in which a joint deconvolution is applied to a set of images with diversity in spatial frequency support among the point spread functions (PSFs) used in the image formation with saturated laser scanning fluorescence microscopy. CSA microscopy allows access to the high spatial frequency diversity in a set of saturated effective PSFs, while avoiding image degradation from shot noise.

Murray, Gabe (ORCID:0000000295655485)↗

Universal dwell time optimization for deterministic optics fabrication

Computer-Controlled Optical Surfacing (CCOS) has been greatly developed and widely used for precision optical fabrication in the past three decades. It relies on robust dwell time solutions to determine how long the polishing tools must dwell at certain points over the surfaces to achieve the expected forms. However, as dwell time calculations are modeled as ill-posed deconvolution, it is always non-trivial to reach a reliable solution that 1) is non-negative, since CCOS systems are not capable of adding materials, 2) minimizes the residual in the clear aperture 3) minimizes the total dwell time to guarantee the stability and efficiency of CCOS processes, 4) can be flexibly adapted to different tool paths, 5) the parameter tuning of the algorithm is simple, and 6) the computational cost is reasonable. In this study, we propose a novel Universal Dwell time Optimization (UDO) model that universally satisfies these criteria. First, the matrix-based discretization of the convolutional polishing model is employed so that dwell time can be flexibly calculated for arbitrary dwell points. Second, UDO simplifies the inverse deconvolution as a forward scalar optimization for the first time, which drastically increases the solution stability and the computational efficiency. Finally, the dwell time solution is improved by a robust iterative refinement and a total dwell time reduction scheme. The superiority and general applicability of the proposed algorithm are verified on the simulations of different CCOS processes. A real application of UDO in improving a synchrotron X-ray mirror using Ion Beam Figuring (IBF) is then demonstrated. The simulation indicates that the estimated residual in the 92.3 mm × 15.7 mm CA can be reduced from 6.32 nm Root Mean Square (RMS) to 0.20 nm RMS in 3.37 min. After one IBF process, the measured residual in the CA converges to 0.19 nm RMS, which coincides with the simulation.

36 MATERIALS SCIENCE↗

Developing Accelerated Test Protocols and Tuning Microstructures of the Common Materials to Improve Robustness, Reliability, and Endurance of SOFC Cells

This work is built on our prior work where we found that phase transformation in praseodymium nickelates, e.g. Pr 2 NiO 4 (PNO) and (Pr 1-x Nd x ) 2 NiO 4 (PNNO), can be electrochemically driven, and is substantially faster when compared to thermal annealing studies. The first task aims at an attempt to further accelerate the phase transformation in the oxygen electrode by alternating the current input in the cells, which lead to the development of accelerated test protocols (ATPs). ATPs showed up to 60x faster phase transformation and up to 10x faster performance degradation in (Pr 0.50 Nd 0.50 ) 2 NiO 4 electrodes, when compared to long-term operation under constant current density. Furthermore, the phase stable Nd 2 NiO 4 and (La 0.6 Sr 0.4 )(Co 0.8 Fe 0.2 )O 3 (LSCF6482) electrodes were tested in full cells under ATPs, and showed up to 10x faster performance degradation within 1,100 hours in a comparison with long-term thermal annealing studies and electrochemical operation under constant current density. The second task aims at the quantification of the contributions of cell components to the total impedance of a solid oxide fuel cell (SOFC) using electrochemical impedance spectroscopy (EIS) and distribution of relaxation times (DRT). Specifically, the role of gas composition at both anode and cathode was systematically studied, aiming at deconvoluting, identifying and quantifying the contributions of different electrode processes. This was achieved by first tuning the partial pressure of H 2 at the anode and subsequently varying the partial pressure of O 2 at the cathode. The results suggest that, while DRT offers a viable way of deconvoluting different times distributions, additional attention is needed before assigning a peak to a specific electrode process due to the significant overlap of the contributions from the cathode and the anode. Density function theory studies show that both Pr-vacancies and O-defects play a key role on the activity and stability for nickelates towards oxygen reduction reaction. The resident O-interstitials and oxygen ions in the PrO layer form peroxide (O 2 2- ) nearby Pr vacancies. The O 2 2- limits oxygen-ion transport due to the required additional energy to break its O-O bond. We further calculated the formation and segregation energies for different Ln ions (La, Pr, Nd, Pm, Sm, Gd, Tb, Dy, and Ho) in PNO and CeO 2 (111) surfaces. In addition to Nd, Pm and La are suggested as potential dopants in PNO to enhance it stability without decomposition due to their more negative formation energies, lower diffusion energies, and positive separation energies.

01 COAL, LIGNITE, AND PEAT↗

Temporal Explosion Source Processes of Declared Nuclear Tests in the Democratic People’s Republic of Korea

In this work we highlight a preliminary temporal source analysis of the six declared Democratic People's Republic of Korea (DPRK) nuclear tests. We use regional seismic data to estimate relative source time functions (RSTFs) via iterative time-domain deconvolution (Ammon, 2006; Pippin, 2022) of vertical-component ground motions recorded within 2000 km of the source region. Since RSTFs are ideally independent of site and propagation effects, their amplitude spectrum is equivalent to the source spectral ratio, but they also retain phase information. We compare observed RSTFs (in the time and frequency domains) with synthetic RSTFs derived from the Mueller & Murphy (1971) explosion source model. The resolution of these time functions varies, however, we generally obtain high-quality results within the limitations of the recording broadband instrumentation. The results indicate that this method effectively preserves source time-history information that can be used for temporal analysis of remote nuclear explosions. This preliminary analysis is intended to assess the viability of using time-domain deconvolution methods for extracting temporal source information.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Super Resolving Unrolled Neural Networks for Remote Sensing

In remote sensing systems, the capabilities of the system are constrained by the complex interactions between size, weight, and power (SWAP) of potential designs. In electro-optical (EO) systems, examples of these critical parameters include the system’s sensitivity and resolution. Those parameters can be increased by ever larger optical apertures and focal planes but at the cost of more SWAP. Multi-image super resolution (MISR) techniques allow resolution to be enhanced via computation rather than more sophisticated optical hardware. These algorithms combine multiple images together into a single, higher resolution image, trading temporal resolution and computation for spatial resolution. Fielded MISR techniques, such as Drizzle, can require several hundred images to create a single super resolved image, implying reduced temporal resolution, increased data acquisition load, and limiting mission applications. Iterative techniques, such as model-based image reconstruction and compressive sensing, have been shown to create super resolved images using fewer images than Drizzle. They do this by posing an optimization problem that balances accuracy between a highly accurate physical model and an image model. In the case of super resolution, the physical model is defined by the relation between low resolution input images and the desired high resolution output image. The image model encodes some assumptions about the super resolved image. These assumptions are meant to suppress reconstruction artifacts that arise due to deterministic physical model error, stochastic measurement noise, and potential undersampling. In practice, the performance of iterative methods are limited by imaging models compatible with optimization. Deep learning-based methods can effectively learn image models of arbitrary complexity, but lack the theoretical explainability and robustness of iterative techniques. Consensus equilibrium (CE) generalizes the iterative techniques beyond optimization, enabling blackbox algorithms such as traditional and neural image denoisers to be used as the image model. CE-based approaches retain much of the explainability and robustness of iterative techniques while allowing the expressiveness of machine learning image models to be used. Additionally, by unrolling iterations of CE with an embedded image denoiser, the image denoiser can be further trained and specialized to the specific application with potentially higher quality reconstructions. Under this project, we demonstrated the feasibility of training an unrolled neural network based upon CE. While we didn’t train one, we showed that the CE process is differentiable and its gradient can be tractably computed. We also explored the usage of a variants of CE akin to generative neural works. Most importantly, we applied the CE framework to a number of problems including non-blind deconvolution, upsampling, single-image super resolution, MISR, event-based sensing, and saturated deconvolution. Our MISR prototype creates high quality reconstructions with an order of magnitude fewer images than previous approaches and, critically, produces these reconstructions fast enough for practical usage.

47 OTHER INSTRUMENTATION↗

Pulse analysis of acoustic emission signals

A method for the signature analysis of pulses in the frequency domain and the time domain is presented. Fourier spectrum, Fourier transfer function, shock spectrum and shock spectrum ratio are examined in the frequency domain analysis, and pulse shape deconvolution is developed for use in the time domain analysis. To demonstrate the relative sensitivity of each of the methods to small changes in the pulse shape, signatures of computer modeled systems with analytical pulses are presented. Optimization techniques are developed and used to indicate the best design parameters values for deconvolution of the pulse shape. Several experiments are presented that test the pulse signature analysis methods on different acoustic emission sources. These include acoustic emissions associated with: (1) crack propagation, (2) ball dropping on a plate, (3) spark discharge and (4) defective and good ball bearings.

Houghton, J. R.↗