Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dead time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Neutron Radiation, Radiation Measurement and the JLab APEX Experiment

The A-prime Experiment (APEX), which is approved to run at the Thomas Jefferson Accelerator Facility (JLab) Hall A, will search for a new vector boson that is hypothesized to be a possible force carrier that couples to dark matter. APEX results should be sensitive to the mass range of 65 MeV to 550 MeV, and high sensitivity will be achieved by means of a high intensity 100 muA beam on a 0.3 g/cm 2 Tungsten target resulting in very high luminosity. The experiment should be able to observe an A-prime with a coupling constant 1 x 10 7 times smaller than the electromagnetic coupling constant. To deal safely with such enormous intensity and luminosity, a full radiation analysis must be used. A Geant4 Monte Carlo simulation was performed to study the radiation environments expected in the JLab Hall A during the APEX experiment. We benchmarked our simulations with measurements carried out during past experiments such as the Pb Radius Experiment (PREX-I). Our PREX-I simulations agreed reasonably well with measurements performed by measuring the change in dark current in a Silicon Photomultipliers as a means of radiation damage. However, our simulations were initially significantly higher than the neutron dose measurements (using NP100) in Hall A. The apparent disagreement hints to several potential problems in NP100 measurements including the dead-time. Further, we identified radiation sources in the beam line and tested several shielding strategies to lower the radiation in Hall A. We characterized several thermal neutron detectors and also studied possibility of damage to electronics due to neutron radiation. We successfully demonstrated that the APEX experiment can be carried out in JLab Hall A without worrying about radiation damage to expensive electronics. The A-prime will appear as a narrow resonance in the invariant mass spectrum of e + e - pairs resulting from the electron beam scattering off the APEX target. In this search for the A-prime, it is critical to have a good mass resolution which is mainly dominated by the track measurement uncertainties. We studied a novel method to calibrate the HRS optics which will improve the accuracy of track measurements. Our results will be used to design HRS calibration runs for the APEX experiment.

Kaluarachchi, Maduka↗

High precision 5 MeV Mott polarimeter

We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.

Grames, J. M. (ORCID:0000000193908752)↗

Advances in detection for neutron reflectometry with time-resolved imaging detectors

Thermal neutron detection in neutron scattering science is a challenging endeavour due to a limited number of technologies which are sensitive to these weakly interacting particles. While many improvements to conventional detectors are underway at various facilities, there is a great opportunity to make a leap in performance by combining the spatial resolution benefits of imaging and the temporal resolution and background discrimination of event-driven radiation detectors. This idea has been realized by using a neutron sensitive scintillator read out by a single-photon sensitive camera based on a Timepix3 ASIC. We demonstrate how such data-driven imaging sensors can enable unprecedented performance in neutron reflectometry using the ASTERIX instrument at the Los Alamos Neutron Scattering Center. Several samples were measured with both the new and a conventional 3 He detector systems. The results from this work demonstrate that these imaging based systems can satisfy performance parameters for the future QIKR reflectometer to be built at the Second Target Station at Oak Ridge National Laboratory. Further improvements to the detector are already underway which will allow streamlined and expedited experiments. We demonstrate at least a two order of magnitude increase in detection rate at an acceptable dead time and introduce a new way of tuning the detector efficiency using light collecting optics to accommodate highly intense direct beams which cannot be measured with any current detectors without severe attenuation. This will allow measurements of complete reflectometry profiles and using a single sample measurement combined with fewer direct beam calibration measurements on QIKR and potentially other reflectometers.

36 MATERIALS SCIENCE↗

Blocking Losses With a Photon Counter

It was not known how to assess accurately losses in a communications link due to photodetector blocking, a phenomenon wherein a detector is rendered inactive for a short time after the detection of a photon. When used to detect a communications signal, blocking leads to losses relative to an ideal detector, which may be measured as a reduction in the communications rate for a given received signal power, or an increase in the signal power required to support the same communications rate. This work involved characterizing blocking losses for single detectors and arrays of detectors. Blocking may be mitigated by spreading the signal intensity over an array of detectors, reducing the count rate on any one detector. A simple approximation was made to the blocking loss as a function of the probability that a detector is unblocked at a given time, essentially treating the blocking probability as a scaling of the detection efficiency. An exact statistical characterization was derived for a single detector, and an approximation for multiple detectors. This allowed derivation of several accurate approximations to the loss. Methods were also derived to account for a rise time in recovery, and non-uniform illumination due to diffraction and atmospheric distortion of the phase front. It was assumed that the communications signal is intensity modulated and received by an array of photon-counting photodetectors. For the purpose of this analysis, it was assumed that the detectors are ideal, in that they produce a signal that allows one to reproduce the arrival times of electrons, produced either as photoelectrons or from dark noise, exactly. For single detectors, the performance of the maximum-likelihood (ML) receiver in blocking is illustrated, as well as a maximum-count (MC) receiver, that, when receiving a pulse-position-modulated (PPM) signal, selects the symbol corresponding to the slot with the largest electron count. Whereas the MC receiver saturates at high count rates, the ML receiver may not. The loss in capacity, symbol-error-rate (SER), and count-rate were numerically computed. It was shown that the capacity and symbol-error-rate losses track, whereas the count-rate loss does not generally reflect the SER or capacity loss, as the slot-statistics at the detector output are no longer Poisson. It is also shown that the MC receiver loss may be accurately predicted for dead times on the order of a slot.

Moision, Burce E.↗

An Efficient, FPGA-Based, Cluster Detection Algorithm Implementation for a Strip Detector Readout System in a Time Projection Chamber Polarimeter

A fundamental challenge in a spaceborne application of a gas-based Time Projection Chamber (TPC) for observation of X-ray polarization is handling the large amount of data collected. The TPC polarimeter described uses the APV-25 Application Specific Integrated Circuit (ASIC) to readout a strip detector. Two dimensional photoelectron track images are created with a time projection technique and used to determine the polarization of the incident X-rays. The detector produces a 128x30 pixel image per photon interaction with each pixel registering 12 bits of collected charge. This creates challenging requirements for data storage and downlink bandwidth with only a modest incidence of photons and can have a significant impact on the overall mission cost. An approach is described for locating and isolating the photoelectron track within the detector image, yielding a much smaller data product, typically between 8x8 pixels and 20x20 pixels. This approach is implemented using a Microsemi RT-ProASIC3-3000 Field-Programmable Gate Array (FPGA), clocked at 20 MHz and utilizing 10.7k logic gates (14% of FPGA), 20 Block RAMs (17% of FPGA), and no external RAM. Results will be presented, demonstrating successful photoelectron track cluster detection with minimal impact to detector dead-time.

Polarimeter↗

Single photon detection with the multi-anode CLAS12 RICH detector

Recently, the first module of the hybrid-optics large-area CLAS12 RICH at JLab has been put into operation using for the first time the well known Hamamatsu H8500 MAPMT and the new single-photon dedicated H12700, for a total of about 400 MAPMTs and 25000 pixels. The photon detector must efficiently detect single photons in the visible and near-UV light region, provide a fast response for background rejection and pattern recognition, and have a spatial resolution of less than 1 cm over an area of ≈1 m 2 . Each front-end readout unit is composed of three electronic boards with specific tasks directly connected to groups of 2 or 3 sensors. The core of the readout is composed of MAROC3 and FPGA chips. The MAROC3 chip is able to discriminate the 64 signals from one MAPMT and to produce 64 corresponding binary outputs with 100% efficiency starting at a small fraction of the single-photon signal, while the FPGA chip provides 1 ns TDC capability with 8 μs maximum latency and acts as a DAQ controller. The system is created to be almost dead-time free at the foreseen 20 kHz CLAS12 trigger rate. The best working conditions for single-photon detection have been studied at laser stands, test beams, and with the JLab electron beam data. A report of the photon detector preparation, commissioning and operation is here discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxygen Isotopic Composition of Refractory Inclusions from the Miller Range (MIL) 090019 Carbonaceous Chondrite

Introduction: Primitive meteorites contain Calcium-Aluminum-rich Inclusions (CAIs)that preserve the records of the earliest times in the Solar System. CAIs record O isotopic variations with time and/or location from solar (16O-rich) to planetary (16O-poor) compositions [e.g., 1, 2].However, CAIs were also affected by parent body processing to varying degrees. The goal of this work was to identify the processes that resulted in the fine-scale spatial variations in oxygen isotopic compositions within the most ancient Solar System solids. We report oxygen isotopic composition of CAIs from MIL 090019 CO3.1 carbonaceous chondrite. MIL 090019 contains a high abundance of CAIs showing mineralogical as well as textural variations [3]. Methods: We analyzed 10 CAIs with different mineralogical assemblages, classified as corundum-bearing, grossite-bearing, hibonite-bearing, melilite-bearing, anorthite-bearing inclusions and amoeboid olivine aggregates(AOA’s). The mineralogical and petrological characterization of CAIs was performed using the JOEL Hyperprobe 8530 electron microprobe at NASA JSC. Oxygen isotopic imaging of the CAIs was done using the Cameca NanoSIMS 50L ion microprobe at NASA JSC. We followed the analytical protocol described in [4]. O-isotopic maps of the CAI were acquired by rastering a ~3 pA primary Cs+beam at 16 keVover an area of 20 ×20μm2over a period of ~7 hours. Negative secondary ions of 16O−, 17O−, 18O−, 28Si−, 24Mg16O−, 27Al16O−, and 40Ca16O−were simultaneously acquired using electron multiplier detectors at a mass resolving power sufficient to resolve the 16OH−interference from the 17O−peak, where the contribution of 16OH−was <0.1%.An electron flood gun was used to mitigate sample charging during the analyses. We used San Carlos olivine and Madagascar hibonite as isotopic standards to correct for the instrumental mass fractionation. The O-isotopic ratios were corrected for the quasi simultaneous arrival (QSA) effect and the detector dead time. All reported errors are 1 sigma. Results: The MIL 090019 carbonaceous chondrite hosts refractory inclusions varying in their mineralogies and textures[2, 3]. We found the oxygen isotopic compositions of mineral phases in MIL 090019 CAIs show large variations with Δ17O values varying from -27 to 0‰. A corundum-bearing inclusion records isotopic variations with corundum, melilite, perovskite, and anorthite showing Δ17Ovalues of -20 ±2.5, -10.2 ± 6.5, -10.7 ± 1.3,and -1.2 ± 3.2‰ respectively. A grossite-hibonite-bearing inclusion also records O-isotopic heterogeneity, where grossite, hibonite, Mg-rich spinel, and melilite show -3.7 ± 2.7, -22.9 ± 2.5, -21.4 ± 2.6, and -17.3 ± 2.8‰ respectively, whereas perovskite grains record a heterogenous isotopic composition ranging from -22.6 to -13.9‰. A hibonite-bearing inclusion shows average Δ17Ο values of -17.6 ± 5.3 ‰ and -15.1 ± 4.8 ‰ for hibonite and spinel respectively. The two perovskite grains also show relatively 16O-poor composition (Δ17Ο = -11.8 ± 6.4 ‰ and -8.6 ± 5.2 ‰). Anorthite has ~0.1 wt% Na2O and ~0.52 wt% FeO and a Δ17Ο value of -7.2 ± 5.0 ‰, whereas diopside records a Δ17Ο value of -3.5 ± 5.0 ‰. A hibonite-spinel-rich inclusion contains spinel and hibonite that are16O-rich (Δ17Οvalues -21.3 ± 2.8‰ and -19.4 ± 3.0‰, respectively). Melilite shows heterogenous oxygen isotopic composition, with an inner 16O-rich region and an outer 16O-poor region separated by a sharp boundary, with a bulk Δ17Ο= -16.2 ± 2.1‰, whereas two perovskite grains are relatively 16O-poor (Δ17Ο= -13.2 ± 3.7‰ and -7.1 ± 3.4‰).A spinel-rich inclusion contains perovskite grains with Δ17Οranging from -27.0 to -22.8 ‰and spinel with average Δ17Οvalue of -21.4 ± 2.8 ‰. In a melilite and spinel-rich CAI, perovskite, spinel, diopside, melilite, and Al-Ti-rich pyroxene record Δ17Ο values of-26.9 ± 4.6‰, -22.4 ± 4.3‰,-23.4 ± 4.9, -19.3 ± 3.4, and -19.0 ± 4.3 ‰ respectively. Olivine and spinel components of 2 AOA’s record a 16O-rich composition with Δ17O~-23‰. Discussion: The coexistence of 16O-rich and 16O-poor minerals within CAIs has been attributed to differing degrees of O isotopic exchange, reflecting a wide range of O diffusion rates[5]. However, the O isotopic heterogeneity observed in these CAIs cannot be explained by oxygen diffusion in nebular or parent body settings alone. The isotopic imaging of CAIs from the MIL 090019 meteorite shows variations in the O isotopic composition recorded in their mineral components, suggesting that these CAIs record the oxygen isotopic heterogeneity in the nebular gas from which they condensed. The coexistence of 16O-rich and 16O-poor mineral components in the CAI-forming region suggests that the gas in this region was not well-mixed and consisted of distinct 16O-rich and 16O-poor gaseous reservoirs.

P Mane↗

X-ray Mapping of Terrestrial and Extraterrestrial Materials Using the Electron Microprobe

Lunar samples returned from the Apollo program motivated development of the Bence-Albee algorithm for the rapid and accurate analysis of lunar materials, and established interlaboratory comparability through its common use. In the analysis of mineral and rock fragments it became necessary to combine micro- and macroscopic analysis by coupling electron-probe microanalysis (EPMA) with automated stage point counting. A coarse grid that included several thousand points was used, and initially wavelength-dispersive (WDS) and later energydispersive (EDS) data were acquired at discrete stage points using approx. 5 sec count times. A approx 50 micrometer beam diameter was used for WDS and up to 500 micrometer beam diameter for EDS analysis. Average analyses of discretely sampled phases were coupled with the point count data to calculate the bulk composition using matrix algebra. Use of a defocused beam resulted in a contribution from multiple phases to each analytical point, and the analytical data were deconvolved relative to end-member phase chemistry on the fly. Impressive agreement was obtained between WDS and EDS measurements as well as comparison with bulk chemistry obtained by other methods. In the 30 years since these methods were developed, significant improvements in EPMA automation and computer processing have taken place. Digital beam control allows routine collection of x-ray maps by EDS, and stage mapping for WDS is conducted continuously at slew speed and incrementally by sampling at discrete points. Digital pulse processing in EDS systems has significantly increased the throughput for EDS mapping, and the ongoing development of Si-drift detector systems promises mapping capabilities rivaling WDS systems. Spectrum imaging allows a data cube of EDS spectra to be acquired and sophisticated processing of the original data is possible using matrix algebra techniques. The study of lunar and meteoritic materials includes the need to conveniently: (1) Characterize the sample at microscopic and macroscopic scales with relatively high sensitivity, (2) Determine the modal abundance of minerals, and (3) Identify and relocate discrete features of interest in terms of size and chemistry. The coupled substitution of cations in minerals can result in significant variation in mineral chemistry, but at similar average Z, leading to poor backscattered-electron (BSE) contrast discrimination of mineralogy. It is necessary to discriminate phase chemistry at both the trace element level and the major element level. To date, the WDS of microprobe systems is preferred for mapping due to high throughput and the ability to obtain the necessary intensity to discriminate phases at both trace and major element concentrations. It is desirable to produce fully quantitative compositional maps of geological materials, which requires the acquisition of k-ratio maps that are background and dead-time corrected, and which have been corrected by phi(delta z> or an equivalent algorithm at each pixel. To date, turnkey systems do not allow the acquisition of k-ratio maps and the rigorous correction in this manner. X-ray maps of a chondrule from the Ourique meteorite, and a comb-layered xenolith from the San Francisco volcanic field, have been analyzed and processed to extract phase information. The Ourique meteorite presents a challenge due to relatively low BSE contrast, and has been studied using spectrum imaging. X-ray maps for Si, Mg, and FeK(alpha) were used to produce RGB images. The xenolith sample contains sector-zoned augite, olivine, plagioclase, and basaltic glass. X-ray maps were processed using Lispix and ImageJ software to produce mineral phase maps. The x-ray maps for Mg, Ca, and Ti were used with traceback to generate binary images that were converted to RGB images. These approaches are successful in discriminating phases, but it is desirable to achieve the methods that were used on lunar samples 30 years ago on current microprobe systems. Curnt research includes x-ray mapping analysis of the Dalgety Downs chondrite by micro x-ray fluorescence and spectrum imaging, in collaboration with Kenny Witherspoon of IXRF Systems and Dale Newbury of NIST.

Carpenter, P.↗

Inline gamma-spectrometry of fission product elements after rapid high-pressure ion chromatographic separation

Analysis of irradiated material shortly after irradiation can be non-trivial due to highly radioactive activation and fission isotopes increasing dead time in gamma-ray detection systems, often requiring a “cooling-period” between receipt of a sample and the subsequent analysis. A direct separation–detection method has been developed combining ion chromatography and inductively coupled mass spectrometry for rapid, low-level analysis of fission products; it cannot, however, detect certain short-lived species below the detection limit of the system. In this paper we report the implementation of an inline gamma-ray detector, which was added post-separation, pre-analysis, to test the quality and utility of elementally-isolated gamma-ray spectroscopy.

Inline gamma-ray detection↗

Design and validation of a gamma-ray scanning system for measuring irradiated nuclear fuel

We report a prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Quantifying particle movement in a spout-fluidized bed with irregular feedstock morphology

Here, the spout-bed fluidization behavior of nonspherical, 140 μm SiC feedstock was quantified via particle image velocimetry for varying gas distributor geometries. A bench-scale, room-temperature fluidization setup was assembled to model a 50 mm fluidized bed chemical vapor deposition (FB-CVD) system, and fluidized bed motion was captured using a high-speed camera. Modular tips with varying inlet geometries were 3D printed and tested on the bench-scale rig using identical feedstock and gas flow rates in the range of 3.0–9.0 L/min. Fluidization behavior was quantified by extracting parameters of the bed velocity, frequency, dead time, and other measurements, which were ranked for each inlet geometry configuration tested. The results from this work demonstrate that changing the path of inlet gas flow can significantly change the hydrodynamics within a spout-fluidized bed under identical feedstock, loading, and flow rate conditions, potentially enabling experimental control of particle fluidization behavior for a given condition. Moreover, composite rankings of fluidization behavior for unique distributor geometries hold potential to guide the design of FB-CVD experiments for various engineering and scientific applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uranium Isotopic Ratio Measurements of U3O8 Reference Materials by Atom Probe Tomography

We report results of measurements of isotopic ratios obtained with atom probe tomography on U3O8 reference materials certified for their isotopic abundances of uranium. The results show good agreement with the certified values. High backgrounds due to tails from adjacent peaks complicate the measurement of the integrated peak areas as well as the fact that only oxides of uranium appear in the spectrum, the most intense of which is doubly charged. In addition, lack of knowledge of other instrumental parameters, such as the dead time, may bias the results. Isotopic ratio measurements can be performed at the nanometer-scale with the expectation of sensible results. The abundance sensitivity and mass resolving power of the mass spectrometer are not sufficient to compete with magnetic-sector instruments but are not far from measurements made by ToF-SIMS of other isotopic systems. The agreement of the major isotope ratios is more than sufficient to distinguish most anthropogenic compositions from natural.

Atom Probe Tomography↗

Gamma Ray Mirrors for Direct Measurement of Spent Nuclear Fuel

Direct measurement of the amount of Pu and U in spent nuclear fuel represents a challenge for the safeguards community. Ideally, the characteristic gamma-ray emission lines from different isotopes provide an observable suitable for this task. However, these lines are generally lost in the fierce flux of radiation emitted by the fuel. The rates are so high that detector dead times limit measurements to only very small solid angles of the fuel. Only through the use of carefully designed view ports and long dwell times are such measurements possible. Recent advances in multilayer grazing-incidence gamma-ray optics provide one possible means of overcoming this difficulty. With a proper optical and coating design, such optics can serve as a notch filter, passing only narrow regions of the overall spectrum to a fully shielded detector that does not view the spent fuel directly. We report on the design of a mirror system and a number of experimental measurements.

multilayer mirrors↗

A new method to reduce the statistical and systematic uncertainty of chance coincidence backgrounds measured with waveform digitizers

We present a new method for measuring chance-coincidence backgrounds during the collection of coincidence data. The method relies on acquiring data with near-zero dead time, which is now realistic due to the increasing deployment of flash electronic-digitizer (waveform digitizer) techniques. An experiment designed to use this new method is capable of acquiring more coincidence data, and a much reduced statistical fluctuation of the measured background. A statistical analysis is presented, and us ed to derive a figure of merit for the new method. Factors of four improvement over other analyses are realistic. The technique is illustrated with preliminary data taken as part of a program to make new measurements of the prompt fission neutron spectra at Los Alamo s Neutron Science Center. In conclusion, it is expected that the these measurements will occur in a regime where the maximum figure of merit will be exploited

47 OTHER INSTRUMENTATION↗

A safeguards approach for molten salt reactors: Direct gamma-spectrometry of 233 U

Multidimensional gamma-spectrometry is a potential solution for safeguarding future thorium-fueled molten salt reactors (MSRs). A high-sensitivity system developed at Pacific Northwest National Laboratory (PNNL), the Advanced Radionuclide Gamma spectrOmeter (ARGO), has demonstrated direct 233 U assay in freshly irradiated fuel salt samples using a dual-detector configuration and the 97.1 keV gamma-emission. These measurements were made using 1.4 x 10 6 Bq of 233 U activity (at 1.4 x 10 8 fissions), at relatively high dead times (10.4%), and using short count durations of ~800 s. Other major emissions were also evaluated (42.5 keV, 54.7 keV, 146.4 keV), in additional to limited (1.96%) Compton suppression, but provided less consistent determination of the 233 U activity. Accurate 233 U measurement was also demonstrated using its four coincidence gamma-emissions (42.5 keV, 54.7 keV; 42.5 keV, 278.1 keV; 146.4 keV, 174.2 keV; 146.4 keV, 219 keV). Further improvements in coincidence measurements may be achievable with improvements in the detector configuration and nuclear data. Whilst this demonstration utilized the ARGO laboratory system, a similar dual-detector configuration could be utilized for online safeguards measurements.

Gamma-spectrometry↗

Development of digital electronics for the search of SHE nuclei using GARIS-II/III at RIKEN

This work describes the implementation of a digital data acquisition system for the search and study of short-lived isotopes or superheavy elements at the GARIS-III separator at the RIKEN Nishina Center. Here a reduction to 26 ± 0.5 keV in the average value of the Full Width at Half Maximum of the alpha spectrum at 7.133 MeV was achieved, combined with a reduction of the dead time of the overall system to around a few tens of nanoseconds for the detection of very fast decay chains. Moreover, we measured a reduction of the background induced by particles crossing the implantation detector using pulse shape analysis techniques. The detail of the optimization and analysis will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-purity germanium semiconductor modeling in the detector response function toolkit

In this study, we have extended the detector response function toolkit (DRiFT) to provide modeling capabilities of semiconductor sensors. DRiFT provides realistic nuclear instrumentation response by post-processing Monte-Carlo N-particle (MCNP®) radiation transport outputs. MCNP® is capable of modeling radiation transport in complex environments, but has limited detector physics and readout electronics modeling capabilities. Semiconductor detector response can be calculated with a high-fidelity for a flexible range of environments by utilizing MCNP® to simulate radiation interactions inside of detector volumes, and then using DRiFT to model charge transport and signal formation in the semiconductor, as well as the readout electronics. DRiFT models charge transport in the semiconductor, the preamplifier, shaping amplifier, pulse pile-up, and electronic noise to generate detector response. The semiconductor application in DRiFT can model a range of semiconductor materials, shapes, and sizes; and is demonstrated here for a large volume coaxial high-purity germanium (HPGe) detector. Here, we compare detector response functions of a coaxial HPGe detector with measurement of 60 Co, 133 Ba, and 137 Cs at varying count rates, and we conduct a parameter study to demonstrate the effect of changing parameters in the DRiFT simulation. The HPGe detector response function shows excellent agreement with measurements of difference sources with varying dead times and count rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute efficiency response of the γ-ray spectrometer GRETINA for high-energy γ rays up to 6 MeV

GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array), a state-of-the-art γ-ray tracking spectrometer, has been instrumental in advancing nuclear structure studies, particularly in experiments using fast beams of rare isotopes where the γ rays emitted in flight are subject to large Doppler shifts. This work presents an experimental determination of the γ-ray detection efficiency of GRETINA at energies up to 6 MeV. The high-energy γ rays originated from states that were populated in nucleon-removal reactions from a projectile beam at an intermediate beam energy of about 85 MeV/nucleon. Utilizing γ-γ coincidences, efficiency values were extracted in-beam and translated into a source efficiency at rest employing GEANT4 Monte Carlo simulations. A systematic discrepancy in the efficiency of the forward-positioned detectors was identified which is attributed to specific dead-time effects caused by high-energy light-particle events prevalent at forward angles, generating signals in the Ge crystals that saturate the preamplifier’s first stage. Furthermore, this study provides refined efficiency benchmarks for in-beam experiments, improving the accuracy of quantitative γ-ray spectroscopy analyses with GRETINA and GRETA (Gamma Ray Energy Tracking Array) in the future.

GRETINA↗