At least 217 records · Page 12

Learning-Accelerated ADMM for Distributed DC Optimal Power Flow

We propose a novel data-driven method to accelerate the convergence of Alternating Direction Method of Multipliers (ADMM) for solving distributed DC optimal power flow (DC-OPF) where lines are shared between independent network partitions. Using previous observations of ADMM trajectories for a given system under varying load, the method trains a recurrent neural network (RNN) to predict the converged values of dual and consensus variables. Given a new realization of system load, a small number of initial ADMM iterations is taken as input to infer the converged values and directly inject them into the iteration. We empirically demonstrate that the online injection of these values into the ADMM iteration accelerates convergence by a significant factor for partitioned 14-, 118- and 2848-bus test systems under differing load scenarios. The proposed method has several advantages: it maintains the security of private decision variables inherent in consensus ADMM; inference is fast and so may be used in online settings; RNN-generated predictions can dramatically improve time to convergence but, by construction, can never result in infeasible ADMM subproblems; it can be easily integrated into existing software implementations. While we focus on the ADMM formulation of distributed DC-OPF in this paper, the ideas presented are naturally extended to other distributed optimization problems.

alternating direction method of multipliers↗

Modular Wide-bandgap String Inverters for Low-cost Medium-voltage Transformerless PV Systems

The proposed technology combines advances in wide-bandgap power electronics with breakthroughs in distributed and decentralized control to produce ultra-low-cost medium-voltage transformerless PV inverters that are composed of stackable lightweight blocks. Taken together, the proposed circuit designs and accompanying control strategies will yield integrated control+circuit (C2) blocks, each comprising a converter and local controller, that can be assembled in a modular fashion to obtain distributed conversion interfaces for next-generation commercial and utility-scale PV systems. We will utilize SiC devices to obtain C2 blocks that can individually operate at a voltage and power in excess of 1 kV and 100 kW, respectively, such that ensembles of series-connected blocks perform direct dc to three-phase ac conversion at medium voltages (e.g., 12 kV–35 kV) and at multi-MW power levels.

42 ENGINEERING↗

Two-dimensional electronic Stark spectroscopy of a photosynthetic dimer

Stark spectroscopy, which measures changes in the linear absorption of a sample in the presence of an external DC electric field, is a powerful experimental tool for probing the existence of charge-transfer (CT) states in photosynthetic systems. CT states often have small transition dipole moments, making them insensitive to other spectroscopic methods, but are particularly sensitive to Stark spectroscopy due to their large permanent dipole moment. In a previous study, we demonstrated a new experimental method, two- dimensional electronic Stark spectroscopy (2DESS), which combines two-dimensional electronic spectroscopy (2DES) and Stark spec- troscopy. In order to understand how the presence of CT states manifest in 2DESS, here, we perform computational modeling and calculations of 2DESS as well as 2DES and Stark spectra, studying a photosynthetic dimer inspired by the photosystem II reaction center. Here, we identify specific cases where qualitatively different sets of system parameters produce similar Stark and 2DES spectra but significantly different 2DESS spectra, showing the potential for 2DESS to aid in identifying CT states and their coupling to excitonic states.

14 SOLAR ENERGY↗

Testing and Expertise for Marine Energy (TEAMER) Program Support (CRADA Final Report)

Virginia Tech (VT) had previously developed a 50 kW AC to DC power converter that is specifically designed to improve the performance and efficiency of wave energy converters (WECs). Through this CRADA, NLR will test the VT power converter via a coupled dynamometer and power electronics test platform. The NLR test platform will be comprised of (1) a rotary dynamometer that will drive a VT provided gearbox and generator, (2) one or more DC regenerative power supplies that provide input power to and take power from the VT supplied power electronics, and (3) a data acquisition system for measurement. NLR will work with VT to develop a test plan, set up the test platform and integrate the test article, perform the testing, and assist in the data analysis.

16 TIDAL AND WAVE POWER↗

DC Microgrid Reliability Enhancement with Adaptive Converter Thermal Management

Due to the different device selections, aging levels, and thermal dissipation performance, some converters may take additional thermal stress on switching devices than others in paralleled converter systems, which will reduce system reliability. To address this problem, this paper proposes a power-sharing strategy with adaptive thermal management. First, the temperature-based power loss model and electrical-thermal model are established. Based on that, a high-accuracy IGBT junction temperature estimate considering the power loss-temperature coupling can be achieved. Further, the thermal-sharing for all the switching devices in paralleled converters can be achieved with the proposed adaptive thermal management strategy. The proposed strategy can change the power-sharing ratio adaptively according to the system operation conditions, which will contribute to the system reliability enhancement. The effectiveness of the proposed strategy is verified through PLECS thermal simulation and joint real-time simulation with Dspace and RT-box.

DC microgrid↗

Experimental system for studying temperature gradient-driven fracture of oxide nuclear fuel out of reactor

Temperature gradients in ceramic light water reactor (LWR) uranium dioxide (UO 2 ) nuclear fuel pellets generate thermal stresses that cause fractures in the fuel beginning early in the life of fresh fuel. The combination of heating due to fission and forced convective cooling on the exterior of LWR fuel rods generates a temperature profile that is difficult to replicate outside the reactor environment. In the present study, a state-of-the-art experimental set-up using electrical heating to replicate fission heating was built and surrogate fuel materials such as ceria (CeO 2 ) were used to validate the system. Cracking experiments were conducted on these surrogates by inducing reactivity-initiated-accident (RIA) like temperature gradients in the pellets via induction and direct resistance heating. Induction heating was done using copper coils and molybdenum susceptors which heated the surrogates to a threshold temperature that is sufficiently high for the fuel material to conduct current. Thereafter, direct resistance heating was used by a D.C. power supply to introduce volumetric heating to replicate LWR operating conditions analogous to fission heating. The pellets were held against nickel electrodes and mounted on a boron nitride test-stand. All the tests were carried out in a stainless-steel vacuum chamber. Simultaneous real-time dual imaging of the surrogate pellet surface has been implemented using an optical and infrared camera system which will be mounted along axial and perpendicular directions to the pellet surface respectively. A beam-splitter was used to split the incoming radiation from the sample into two halves. While one of the beams is transmitted from the splitter through a bandpass filter to obtain optical images, the other beam is reflected from the splitter to the thermal camera to capture full field temperature gradients of the as fabricated pellet surface during crack initiation and propagation. In the current series of tests, a 2-color pyrometer was used for recording and comparing the surface and centerline temperatures of the surrogate pellets in lieu of the thermal camera. A LabVIEW data acquisition system has been set up for collecting useful data during experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploring the design space of PV-plus-battery system configurations under evolving grid conditions

In this study, we explore how the energy and capacity values of coupled systems comprising solar photovoltaic arrays and battery storage (PV-plus-battery systems) could evolve over time based on the evolution of the bulk power system. Using a price-taker model with simulated hourly energy and capacity prices projected from the present to 2050, we simulate the revenue-maximizing dispatch of a range of DC-coupled PV-plus-battery configurations in three locations in the United States. These configurations are defined by the inverter loading ratio (ILR, the ratio of the PV array capacity to the inverter capacity, which we vary from 1.4 to 2.6) and the battery-inverter ratio (BIR, the ratio of the battery power capacity to the inverter capacity, which we vary from 0.25 to 1.0). Based on each configuration's total value, we estimate the breakeven costs needed to justify each incremental increase in ILR (holding BIR constant) or BIR (holding ILR constant). We find that, in a future with low-cost renewable energy technologies, PV-plus-battery system ILRs can be economically increased to around 2.0-2.4 at a BIR of 1.0, depending on solar resource. Our results indicate that a likely evolution of PV-plus-battery system design will be increasingly greater battery power capacity to mitigate the declining PV capacity value, which will, in turn, enable increasingly higher ILRs to further increase energy value. The extent to which PV-plus-systems will be deployed with increasingly higher ILRs depends primarily on whether PV cost declines outpace declining value and increasing curtailment over time.

14 SOLAR ENERGY↗

Harmonics and Stability Evaluation of Converter-Interfaced Combined Heat and Power Units

Grid integration of medium-sized combined heat and power (CHP) units is challenging due to strict grid codes and conventional generators lack of control flexibility to meet these grid codes. Adding a two-stage ac-dc-ac power electronics interface between the generator and the utility grid will accelerate the interconnection process of CHP units. For the dc-ac stage, a voltage source converter (VSC) has been widely used as a grid-tied inverter because of its fast control and low total harmonics distortion (THD). In this paper, several topologies of generator-side rectifiers for ac-dc power conversion are explored and analyzed. The harmonics impact of various rectifiers on the CHP generator are evaluated. The overall cost of the electrical system, when using various types of rectifiers, is assessed and the VSC back-to-back converter interface configuration is found to be optimal. The overall system stability is also examined using small-signal impedance analysis to assess potential instability issues at the system level.

CHP, Harmonics, Generator Rectifier Unit, DC Imped↗

Optimal Operation of PV Sources in DC Grids for Improving Technical, Economical, and Environmental Conditions by Using Vortex Search Algorithm and a Matrix Hourly Power Flow

This document presents a master–slave methodology for solving the problem of optimal operation of photovoltaic (PV) distributed generators (DGs) in direct current (DC) networks. This problem was modeled using a nonlinear programming model (NLP) that considers the minimization of three different objective functions in a daily operation of the system. The first one corresponds to the minimization of the total operational cost of the system, including the energy purchasing cost to the conventional generators and maintenance costs of the PV sources; the second objective function corresponds to the reduction of the energy losses associated with the transport of energy in the network, and the third objective function is related to the minimization of the total emissions of CO2 by the conventional generators installed on the DC grid. The minimization of these objective functions is achieved by using a master–slave optimization approach through the application of the Vortex Search algorithm combined with a matrix hourly power flow. To evaluate the effectiveness and robustness of the proposed approach, two test scenarios were used, which correspond to a grid-connected and a standalone network located in two different regions of Colombia. The grid-connected system emulates the behavior of the solar resource and power demand of the city of Medellín-Antioquia, and the standalone network corresponds to an adaptation of the generation and demand curves for the municipality of Capurganá-Choco. A numerical comparison was performed with four optimization methodologies reported in the literature: particle swarm optimization, multiverse optimizer, crow search algorithm, and salp swarm algorithm. The results obtained demonstrate that the proposed optimization approach achieved excellent solutions in terms of response quality, repeatability, and processing times.

14 SOLAR ENERGY↗

Frequency Resilience Enhancement for Power Systems with High Penetration of Grid-Forming Inverters

Abstract—Grid following inverter-based renewable generation has replaced conventional generation in recent years, resulting in lower system inertia. The frequency resilience in such a lower inertia system is critical for emergency mitigation. In this paper, we propose a resilience metric based on frequency recovery to quantitatively represent system resilience in terms of the rate of change of frequency. Application of grid-forming converters provides a means to improve system resilience by providing virtual inertia. An under-frequency load shedding strategy is applied to further support frequency recovery in cases with high penetration of grid-forming inverters. Case studies are designed and performed in a modified IEEE 9-bus test system using the PSCAD/EMTDC platform. Simulation results demonstrate the validity of the proposed resilience metric and the effectiveness of the strategy for reducing frequency excursion in inverter-based power systems. citation: J. Gui, H. Lei, T. R. McJunkin and B. K. Johnson, "Frequency Resilience Enhancement for Power Systems with High Penetration of Grid-Forming Inverters," 2023 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT), Washington, DC, USA, 2023, pp. 1-5, doi: 10.1109/ISGT51731.2023.10066357.

14 SOLAR ENERGY↗

Next Generation Solid Oxide Fuel Cell Module Development

The overall objective of this project was to develop a transformative Solid Oxide Fuel Cell (SOFC) building block configuration comprised of multi-stack arrays that can be utilized in large-scale power plants. This transformative design signified the benefits of lower performance degradation coupled with improved reliability, low cost, smaller packaging for easier transport and installation, and improved maintenance and field serviceability characteristics. The project goal was to design and fabricate a scalable hot module for housing an array of SOFC stacks and to demonstrate the characteristics of the module gas distribution, insulation and instrumentation, and DC power take-off. The approach was to validate the design of a stack prototype scalable to megawatt (MW) class systems using FuelCell Energy’s Compact SOFC Architecture (CSA) stacks. The scope of work was intended to design, build, and test a compact and low-cost multi-stack sub-module with flexibility to house CSA stacks and scalable to 350 kW which could ultimately be deployed in construction of MW-class systems.

20 FOSSIL-FUELED POWER PLANTS↗

Cost and Efficiency Analysis for Hybrid AC/DC Distribution System Planning with PV and Battery

Distribution system planning is one of the main tasks for the electric utilities. Cost and energy efficiency are two main concerns in the distribution planning process. In this work, cost and efficiency analyses are conducted for the hybrid AC and DC distribution grids for the planning purposes. The IEEE 34-bus feeder has been applied for the case studies. The investment cost, operation and maintenance cost, replacement cost, etc., have been considered in the life cycle cost analysis. Power losses of both the AC and DC section are calculated with an open source simulation tool, the Open Distribution Simulator Software (OpenDSS). The proposed framework can be applied to quantitatively evaluate the cost and efficiency of hybrid AC and DC distribution grids and help comparing different planning options.

AC/DC hybrid system planning↗

Interposed pulsed power system for fast separation of radioactive beams

This paper presents the novel design of an interposed pulsed power system, developed to drive a fast-switching magnet with a large multi-mH load inductance, and high field amplitude (> 1 T). This modulator can produce variable flat-top pulses from 1 to 30 ms with rise and fall times of less than 0.5 ms at a variable duty cycle of 3–91% into a heavily inductive load. The system employs a novel over-voltage topology to overcome the inherent inductance and achieve the fast rise and fall times, switching to a precision DC supply to efficiently maintain the flattop without requiring many-kV voltage. We present a power source design consideration, including the results of computer modeling as well as the first experimental results of a modulator scaled test model will also be presented.

47 OTHER INSTRUMENTATION↗

A Model for Evaluating the Configuration and Dispatch of PV Plus Battery Power Plants

An open-source model was developed to optimize energy storage operation for photovoltaic- (PV-) plus-battery systems with AC-coupled and DC-coupled configurations. It includes the ability to use forecast energy prices to optimize battery charge and discharge on a rolling time horizon. The model allows for exploration of different configurations, including capital costs, inverter performance, dispatch flexibility, and capturing otherwise clipped energy for the DC-coupled system. The model can run 20 full years of hourly data in approximately two seconds, allowing comparison of a large number of configurations. We applied the model in a test case demonstrating reduced inverter clipping for DC-coupled systems and yielded slightly higher overall value than AC-coupled systems, with an approximately 2 percent increase in internal rate of return or benefit/cost ratio. Our results show that at current estimated prices for lithium-ion battery systems, large-scale PV-plus-battery plants are economically viable under the right conditions, with the configuration playing a role in system flexibility and performance. This model provides the ability for project developers, industry professionals, and researchers to use readily available software to quickly evaluate and design these systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Enhanced Depolarized Electro-Membrane System (EDEMS) for Direct Capture of Carbon Dioxide from Ambient Air (Final Report)

The goal of this final project report is to summarize the work conducted on project DE-FE0031962. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UK CAER) (Recipient) developed an intensified process to capture CO2 from ambient conditions (400 ppm CO2). The process combines low-temperature solvent-aided membrane capture with electrochemically-mediated solvent regeneration to simultaneously capture ambient CO2 while regenerating the solvent. The technology employs only two primary units (regenerator and absorber/contactor) while generating high purity hydrogen as a co-product that can be sold, used for energy storage, or cost-saving depolarization of the direct air capture (DAC) system during the grid peak demand, allowing for flexible operation. When depolarization is employed, the operating voltage is reduced by more than 1 V. Since the technology is powered directly by DC electricity, it can seamlessly tie in with power sources like solar cells without the need for AC/DC converters, therefore allowing for a remote operation to further mitigate greenhouse gas generation toward deploying a negative carbon emissions technology that is completely decoupled from the carbon emissions from the power source for the DAC unit. The project results verified that UK CAER’s integrated approach addressed the complexities of incumbent DAC systems by demonstrating at ambient conditions, including (1) low gas-side pressure-drop facile CO2 capture via a membrane contactor with in-situ generated hydroxide as capture solvent, (2) multi-functional electrochemical regenerator for hydroxide regeneration, CO2 concentration and hydrogen production, and (3) depolarization using cathode-produced hydrogen to reduce energy requirement. The EH&S Assessment of the process did not identify any obvious concern for the bench-scale operation and no apparent barriers to implementing UK CAER’s carbon capture and solvent regeneration system at a larger scale.

20 FOSSIL-FUELED POWER PLANTS↗

Design considerations of series type hybrid circuit breaker (S‐HCB)

Abstract The series‐type direct current (DC) hybrid circuit breaker (S‐HCB) concept was previously reported to offer better performance than solid‐state circuit breakers (SSCB) and hybrid circuit breakers (HCB). S‐HCB offers low conduction power loss like an HCB and ‐scale interruption time, which is even faster than an SSCB. It uses a pulse transformer to isolate the lower‐voltage high‐inductance power electronic circuit from the high‐voltage, low‐inductance main power loop. This paper provides analysis of the impact of the S‐HCB circuit components on the overall system performance and a scalable S‐HCB design guide for different DC system voltage and current ratings. In addition, system energy flow analysis is performed in the time domain to provide an understanding of how energy is delivered, dissipated, and released throughout the entire fault interruption process. The S‐HCB prototype was experimentally tested at 3 kV/30 A and 6 kV/150A with the results showing the interruption of the low fault current of 30 A and the high fault current of 150 A within 8 and maintaining the fault current at a near zero value for 300 to enable an arcless opening of a series mechanical switch. The key design challenges of S‐HCB at high voltage and high current ratings were discussed and possible solutions to mitigate those challenges were introduced.

Alashi, Mahmoud↗

The LSBmax algorithm for boosting resilience of electric grids post (N‐2) contingencies

Abstract A computationally improved algorithm is presented to find the best transmission switching (TS) candidate for boosting resilience of electricity grids subject to ( N ‐2) contingencies. Here, resilience is computed as the reduction in load shed after the above‐mentioned ( N‐ ) contingencies. TS is a planned line outage, and past research shows that changing the transmission system's topology changes the power flow and removes post contingency violations. Finding the best TS candidate in a computationally suitable time for effectively boosting resilience is a challenge. The best TS candidate is found using a novel heuristic method by decreasing the search space based on proximity to the bus with the maximum load shedding (LSB). The LSB algorithm is faster than existing algorithms in the literature; and, it is compatible with both the AC and DC optimal power flow formulations. To validate the authors' claims of speedup and accuracy, two metrics are used to analyze the results from the IEEE 39‐bus and 118‐bus systems. Finally, the inherent parallelism of the LSB algorithm is leveraged on a high‐performance computing platform and applied to the large‐scale Polish 2383‐bus test system to validate scalability in both size and speedup in computation time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Isolated Single-stage Three-phase AC/DC Converter using Bidirectional Switches

The advent of the SiC Bidirectional FET (BiDFET), a monolithic 1.2 kV bidirectional switch, has rendered the single-stage three-phase AC/DC converter topology a promising approach for implementing AC/DC converters. This topology, which integrates a full-bridge converter with a single-phase to three-phase matrix converter via a high-frequency transformer, is particularly suitable for applications requiring galvanic isolation, buck-boost functionality, and bidirectional power flow. The single-stage design eliminates the need for bulky and unreliable electrolytic capacitors, and utilizes a single magnetic component for power transfer. In the matrix converter, bidirectional switches, which were traditionally implemented using combinations of multiple semiconductor devices such as MOSFETs, IGBTs, and diodes, can now be realized using the single-chip solution, BiDFET. This advancement leads to a lower switch count, compact converter implementation, with lower inductance commutation cells, thereby enhancing the overall efficiency and compactness of the system. The paper presents a unified model of the converter, considering all control parameters, including the duty cycles and phase shift of transformer voltages. Detailed expressions for power transfer, transformer currents, and currents at AC and DC ports are provided. Additionally, the paper outlines the conditions necessary for soft-switching of all switches and the commutation schemes required for the practical implementation of the matrix converter modulation scheme. A hardware prototype of a 10 kW, 480 VRMS, LL/ 800 V AC/DC system has been developed, and experimental results are presented to demonstrate its performance.

BiDFET↗