Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data housing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Long-Term Results: New Construction Occupied Test House, Urbana, Illinois

For this study, a house was designed and built to the Passive House (Passivhaus) Standard for low energy consumption. The house incorporates an airtight, super-insulated thermal enclosure, southern facing windows with overhangs, a single point mini-split heat pump and electric resistance heaters, and a balanced energy recovery ventilator (ERV). The house was instrumented with sub-metering on all major electrical circuits, temperature and humidity measurements in each room, domestic hot water consumption, and recovery efficiency of the ERV. The energy performance was documented and compared to modeled predictions, and the thermal comfort performance of the heat pump was assessed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Retrofit Field Study and Best Practices in a Hot-Humid Climate

Energy efficiency improvement as a component of comprehensive renovation was investigated under U.S. Department of Energy (DOE) funding of the Building America Partnership for Improved Residential Construction (BA-PIRC). Researchers at the Florida Solar Energy Center (FSEC) worked with affordable housing partners renovating foreclosed homes built from the 1950's through the 2000's in the hot-humid climate (within the Southern census region), primarily in Florida. Researchers targeted a 30% improvement in whole-house energy efficiency along with the health and safety, durability, and comfort guidelines outlined in DOE's Builders Challenge Program (Version 1) Quality Criteria.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Management at the Advanced Photon Source

Data are crucial to the scientific discoveries enabled by experiments performed at the APS. Presently the APS generates approximately 10 PB of raw experimental data per year from its sixty-six operating beamlines that house over 100 unique instruments. This data is generated as a part of over 6,000 annual experiments performed by over 5,500 facility users each year. Similar to other synchrotrons, the amount of data generated at the APS continues to quickly increase due to beamline advances, such as new measurement techniques, technological advances in detectors, high-throughput instrumentation, multi-modal instruments that can acquire several measurements in a single experiment, and advanced data processing algorithms. This trend is expected to continue in the future. The revolutionized high-energy synchrotron facility proposed in the APS-U project will increase brightness and coherence, leading to further increases in data rates. Successful management of data is of vital importance to the current and future scientific productivity of the APS.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Comfort in High-Performance Homes in a Hot-Humid Climate

IBACOS monitored 37 homes during the late summer and early fall of 2014 in a hot and humid climate to better understand indoor comfort conditions. These homes were constructed in the last several years by four home builders that offered a comfort and performance guarantee for the homes. The homes were located in one of four cities: Tampa, Florida; Orlando, Florida; Houston, Texas; and San Antonio, Texas. Temperature and humidity data were collected from the thermostat and each room of the house using small, battery-powered data loggers. To understand system runtime and its impact on comfort, supply air temperature also was measured on a 1-minute interval. Overall, the group of homes only exceeded a room-to-room temperature difference of 6 degrees Fahrenheit for 5% of the time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic Analyte-Ion Recognition and Background Removal for Ambient Mass-Spectrometric Data Based on Cross-Correlation

Ambient mass spectrometry is a powerful approach for rapid, high-throughput, and direct sample analysis. Due to the open-air desorption and ionization processes, random fluctuations of ambient conditions can lead to large variances in mass-spectral signals over time. The mass-spectral data also can be further complicated due to multiple analytes present in the sample, background-ion signals stemming from the desorption/ionization source itself, and other laboratory-specific conditions (e.g., ambient laboratory air, nearby hardware). Thus, background removal and analyte-ion recognition can be quite difficult, particularly in non-targeted analyses. Here, we demonstrate the use of a cross-correlation-based approach to exploit chemical information encoded in the time domain to group/categorize mass-spectral peaks from a single analysis dataset. Ions that originate from ambient (or other) background species were readily flagged and removed from spectra; the result was a decrease in mass-spectral complexity by over 70% due to the removal of these background ions. Meanwhile, analyte ions were differentiated and categorized based on their time-domain profiles. With sufficient mass resolving-power and mass-spectral acquisition rate, isolated mass spectra containing ions from the same species in a sample could be extracted, leading to a reduction in mass-spectral complexity by more than 98% in some cases. The cross-correlation approach was tested with different ionization sources as well as reproducible and irreproducible sample introduction. Software built in-house enabled fully automated data processing, which can be performed within a few seconds. Ultimately, this approach provides an additional dimension of analyte separation in ambient mass-spectrometric analyses with information that is already recorded throughout the analysis. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Protein Data Bank: A Comprehensive Review of 3D Structure Holdings and Worldwide Utilization by Researchers, Educators, and Students

The Research Collaboratory for Structural Bioinformatics Protein Data Bank (RCSB PDB), funded by the United States National Science Foundation, National Institutes of Health, and Department of Energy, supports structural biologists and Protein Data Bank (PDB) data users around the world. The RCSB PDB, a founding member of the Worldwide Protein Data Bank (wwPDB) partnership, serves as the US data center for the global PDB archive housing experimentally-determined three-dimensional (3D) structure data for biological macromolecules. As the wwPDB-designated Archive Keeper, RCSB PDB is also responsible for the security of PDB data and weekly update of the archive. RCSB PDB serves tens of thousands of data depositors (using macromolecular crystallography, nuclear magnetic resonance spectroscopy, electron microscopy, and micro-electron diffraction) annually working on all permanently inhabited continents. RCSB PDB makes PDB data available from its research-focused web portal at no charge and without usage restrictions to many millions of PDB data consumers around the globe. It also provides educators, students, and the general public with an introduction to the PDB and related training materials through its outreach and education-focused web portal. This review article describes growth of the PDB, examines evolution of experimental methods for structure determination viewed through the lens of the PDB archive, and provides a detailed accounting of PDB archival holdings and their utilization by researchers, educators, and students worldwide.

59 BASIC BIOLOGICAL SCIENCES↗

Load Shifting with Space Conditioning Heat Pumps During Heating Season in the Pacific Northwest

Ductless mini- and multi-split heat pumps are commonly deployed in Pacific Northwest residences, which historically have inefficient space heating and no space cooling. Heat pumps provide these residences with more energy-efficient space heating in the winter and space cooling for increasingly warm summer periods. For many of these applications, heat pumps add a new electrical load at the residence, compelling regional utilities to seek to understand their impacts on the electrical grid and opportunities for load management. In coordination with regional utilities, this study examined the winter load-shifting potential of residential multi-split heat pumps with variable capacity technology. The study included nine residential sites with a total of 20 ductless indoor units, which underwent simulated smart grid control. Grid control functionality was provided through the CTA-2045 communication protocol and included offsetting temperature setpoints for individual indoor units in the study. Field data collection included whole-house and heating, ventilation, and air conditioning electrical power consumption; indoor zone temperatures; occupant surveys; and CTA-2045 curtailment data for both baseline and simulated load-shifting events by site. This paper provides an overview of the load-shifting strategies and aggregated results from winter data collection.

ASHRAE, Heat pump, energy effciency, residential b↗

Investigating power capping toward energy-efficient scientific applications: Investigating Power Capping toward Energy-Efficient Scientific Applications

The emergence of power efficiency as a primary constraint in processor and system design poses new challenges concerning power and energy awareness for numerical libraries and scientific applications. Power consumption also plays a major role in the design of data centers, which may house petascale or exascale-level computing systems. At these extreme scales, understanding and improving the energy efficiency of numerical libraries and their related applications becomes a crucial part of the successful implementation and operation of the computing system. In this paper, we study and investigate the practice of controlling a compute system's power usage, and we explore how different power caps affect the performance of numerical algorithms with different computational intensities. Further, we determine the impact, in terms of performance and energy usage, that these caps have on a system running scientific applications. This analysis will enable us to characterize the types of algorithms that benefit most from these power management schemes. Our experiments are performed using a set of representative kernels and several popular scientific benchmarks. Lastly, we quantify a number of power and performance measurements and draw observations and conclusions that can be viewed as a roadmap to achieving energy efficiency in the design and execution of scientific algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wafer heating mechanisms in a molecular gas, inductively coupled plasma: in situ, real time wafer surface measurements and three-dimensional thermal modeling

The authors report measurements and modeling of wafer heating mechanisms in an Ar/O{sub 2} inductively coupled plasma (ICP). The authors employed a commercially available on-wafer sensor system (PlasmaTemp developed by KLA-Tencor) consisting of an on-board electronics module housing battery power and data storage with 30 temperature sensors embedded onto the wafer at different radial positions. This system allows for real time, in situ wafer temperature measurements. Wafer heating mechanisms were investigated by combining temperature measurements from the PlasmaTemp sensor wafer with a three-dimensional heat transfer model of the wafer and a model of the ICP. Comparisons between pure Ar and Ar/O{sub 2} discharges demonstrated that two additional wafer heating mechanisms can be important in molecular gas plasmas compared to atomic gas discharges. The two mechanisms are heating from the gas phase and O-atom surface recombination. These mechanisms were shown to contribute as much as 60% to wafer heating under conditions of low bias power. This study demonstrated how the 'on-wafer' temperature sensor not only yields a temperature profile distribution across the wafer, but can be used to help determine plasma characteristics, such as ion flux profiles or plasma processing temperatures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-J-181: An Alternative Patient Alignment Tool On TomoTherapy: The First In- Human Megavoltage-Topogram Acquisition

Purpose: To show the first in-human Megavoltage (MV)-Topogram acquisition for the evaluation of the potential for MV-Topogram-based alignment as an alternative to MVCT for reducing dose and imaging time. Methods: A lung cancer patient was enrolled in an ongoing IRB-approved clinical trial at our institute. The patient was set up using the clinical protocol employing positioning lasers. 3.2mm diameter tungsten spheres were placed on the patient’s skin at their alignment tattoos to check surface-based marker concordance between topograms and MVCT. Anterior-Posterior (AP) and lateral (LAT) MV-Topograms were acquired using gantry angles of 0°/90° with a 1mm collimator opening, all MLC leafs open, 4cm/s couch speed, and 12.5s scanning time. The topogram acquisition was immediately followed by the normal MVCT scan acquisition. MV-Topograms were reconstructed from the detector exit-data using in-house developed software. The topograms were also enhanced using contrast-limited adaptive histogram equalization (CLAHE). The MV-Topograms were registered to reference kV-based digitally reconstructed topograms. The localization results were compared against results obtained comparing the clinical MVCT to the kVCT simulation. Results: The shifts using the unenhanced Topograms, enhanced Topograms, and MVCT were (LAT, LONG, VERT, ROLL) (5.8mm, 2.6mm, −5.6mm, 0.34°), (3.9mm, 2.5mm, −2.2mm, 0.65°) and (2.4mm, 1.5mm, −3.0mm, 0.5°), respectively. The magnitude alignment differences between the enhanced Topograms and MVCT were within 1.5 mm and 0.15°. The average MVCT and total Topogram acquisition times were 272.9s ± 31.5s and 46s, respectively. Conclusion: MV-Topograms have the potential for providing equivalent performance with less dose and acquisition time than the traditional MVCT technique. We are evaluating other sites as well as adding patients to develop statistically significant analyses regarding the alignment quality differences. MV-Topograms are likely to be most clinically useful for bony anatomy and radiopaque marker-based alignments. The study was supported by an Accuray Grant.

60 APPLIED LIFE SCIENCES↗

Spray Foam in Accessible Spaces: Best Practices and Case Studies for Retrofit in Mixed-Humid Climates

Heating and cooling the house is one of the homeowners major expenses. Reducing these costs, saving energy, and creating a healthier, more comfortable indoor environment are good reasons to consider improving the building thermal envelope. Improvements usually consider increasing the amount of insulation, reducing the infiltration of outside air, and controlling moisture in existing buildings. This report describes the use of spray foam materials to insulate, seal, and control moisture. This discussion is limited to treating areas that are accessible. What is accessible, however, can vary depending on the type of renovation. If the building has been gutted or exterior surfaces removed, there are more options. This report will look at areas to consider for spray foam application and discuss the types of spray foams available and their uses. A number of case studies are presented to show the effectiveness of this retrofit in existing houses based on performance data.

Best practices↗

Building America Indoor Temperature and Humidity Measurement Protocol

When modeling homes using simulation tools, the heating and cooling set points can have a significant impact on home energy use. Every 4 years the Energy Information Administration (EIA) Residential Energy Consumption Survey (RECS) asks homeowners about their heating and cooling set points. Unfortunately, no temperature data is measured, and most of the time, the homeowner may be guessing at this number. Even one degree Fahrenheit difference in heating set point can make a 5% difference in heating energy use! So, the survey-based RECS data cannot be used as the definitive reference for the set point for the 'average occupant' in simulations. The purpose of this document is to develop a protocol for collecting consistent data for heating/cooling set points and relative humidity so that an average set point can be determined for asset energy models in residential buildings. This document covers the decision making process for researchers to determine how many sensors should be placed in each home, where to put those sensors, and what kind of asset data should be taken while they are in the home. The authors attempted to design the protocols to maximize the value of this study and minimize the resources required to achieve that value.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Building America Indoor Temperature and Humidity Measurement Protocol

When modeling homes using simulation tools, the heating and cooling set points can have a significant impact on home energy use. Every four years, the Energy Information Administration (EIA) Residential Energy Consumption Survey (RECS) asks homeowners about their heating and cooling set points. Unfortunately, no temperature data is measured, and most of the time, the homeowner may be guessing at this number. Even one degree Fahrenheit difference in heating set point can make a 5% difference in heating energy use! So, the survey-based RECS data cannot be used as the definitive reference for the set point for the "average occupant" in simulations. The purpose of this document is to develop a protocol for collecting consistent data for heating/cooling set points and relative humidity so that an average set point can be determined for asset energy models in residential buildings. This document covers the decision making process for researchers to determine how many sensors should be placed in each home, where to put those sensors, and what kind of asset data should be taken while they are in the home. The authors attempted to design the protocols to maximize the value of this study and minimize the resources required to achieve that value.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The application of remote sensing techniques to inter and intra urban analysis

This is an effort to assess the applicability of air and spaceborne photography toward providing data inputs to urban and regional planning, management, and research. Through evaluation of remote sensing inputs to urban change detection systems, analyzing an effort to replicate an existing urban land use data file using remotely sensed data, estimating population and dwelling units from imagery, and by identifying and evaluating a system of urban places ultilizing space photography, it was determined that remote sensing can provide data concerning land use, changes in commercial structure, data for transportation planning, housing quality, residential dynamics, and population density.

Horton, F. E.↗

Prototype solar heating and cooling systems, including potable hot water

Progress made in the development, delivery, and support of two prototype solar heating and cooling systems including potable hot water is reported. The system consists of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition. A comparison of the proposed Solaron Heat Pump and Solar Desiccant Heating and Cooling Systems, installation drawings, data on the Akron House at Akron, Ohio, and other program activities are included.

Bloomquist, D.↗

Fatigue and fracture research in metals

Fatigue and fracture research on monolithic and laminated metals is discussed. The research concentrated on three areas: stress analyses of two and three dimensional cracked bodies, fatigue crack growth, and fracture toughness. Analytical methods were developed to predict fatigue crack growth and fracture strengths of cracked specimens. Such specimens represent typical aircraft structural details (such as cracks from holes). These specimens were subjected to simple constant amplitude loading and to more complex flight load histories. Test data from both in house tests and from the literature are used to substantiate the analytical methods. These analyses extended the theory of fracture mechanics to deal with fatigue crack growth and fracture of complex crack configurations that are typical of aircraft materials and structural details.

J. C. Newman, Jr.↗

Interdisciplinary Investigations in Support of Project DI-MOD

Various concepts from time series analysis are used as the basis for the development of algorithms to assist in the analysis and interpretation of remote sensed imagery. An approach to trend detection that is based upon the fractal analysis of power spectrum estimates is presented. Additionally, research was conducted toward the development of a software architecture to support processing tasks associated with databases housing a variety of data. An algorithmic approach which provides for the automation of the state monitoring process is presented.

Starks, Scott A.↗

An Ecosystem Model for the Simulation of Physical and Biological Oceanic Processes-IDAPAK User's Guide and Applications

This TM describes the development, testing, and application of a 4-component (phytoplankton, zooplankton, nitrate, and ammonium) ecosystem model capable of simulating oceanic biological processes. It also reports and documents an in-house software package (Interactive Data Analysis Package - IDAPAK) for interactive data analysis of geophysical fields, including those related to the forcing, verification, and analysis of the ecosystem model. Two regions were studied in the Pacific: the Warm Pool (WP) in the Equatorial Pacific (165 deg. E at the equator) and at Ocean Weather Station P (OWS P) in the Northeast Pacific (50 deg. N, 145 deg. W). The WP results clearly indicate that the upwelling at 100 meters correlates well with surface blooms. The upwelling events in late 1987 and 1990 produced dramatic increases in the surface layer values of all 4 ecosystem components, whereas the spring-summer deep mixing events, do not seem to incur a significant response in any of the ecosystem quantities. The OWS P results show that the monthly profiles of temperature, the annual cycles of solar irradiance, and 0- to 50-m integrated nitrate accurately reproduce observed values. Annual primary production is 190 gC/m(exp 2)/yr, which is consistent with recent observations but is much greater than earlier estimates.

McClain, Charles R.↗