Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “custom devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Calibration of the SHERLOC Deep Ultraviolet Fluorescence–Raman Spectrometer on the Perseverance Rover

We describe the wavelength calibration of the spectrometer for the scanning of habitable environments with Raman and luminescence for organics and chemicals (SHERLOC) instrument onboard NASA’s Perseverance Rover. SHERLOC utilizes deep ultraviolet Raman and fluorescence (DUV R/F) spectroscopy to enable analysis of samples from the Martian surface. SHERLOC employs a 248.6 nm deep ultraviolet laser to generate Raman-scattered photons and native fluorescence emission photons from near-surface material to detect and classify chemical and mineralogical compositions. The collected photons are focused on a charge-coupled device and the data are returned to Earth for analysis. The compact DUV R/F spectrometer has a spectral range from 249.9 nm to 353.6 nm (200 cm1 to 12, 000 cm1) (with a spectral resolution of 0.296 nm (40 cm1)). The compact spectrometer uses a custom design to project a high-resolution Raman spectrum and a low-resolution fluorescence spectrum on a single charge-coupled device. The natural spectral separation enabled by deep ultraviolet excitation enables wavelength separation of the Raman/fluorescence spectra. The SHERLOC spectrometer was designed to optimize the resolution of the Raman spectral region and the wavelength range of the fluorescence region. The resulting illumination on the charge-coupled device is curved, requiring a segmented, nonlinear wavelength calibration in order to understand the mineralogy and chemistry of Martian materials.

Kyle Uckert↗

Analyzing Risks of Virtual Private Network Connections

The use of Splunk for analyzing VPN logs is an effective approach for identifying vulnerabilities in network endpoints. Splunk, a powerful platform for searching, monitoring, and analyzing machine-generated data, enables organizations to aggregate VPN logs in real-time, providing insights into network activity, user behavior, and potential security risks. By indexing VPN traffic and authentication logs, security teams can track abnormal patterns such as multiple failed login attempts, unusual IP addresses, or unexpected changes in bandwidth usage, all of which could indicate potential vulnerabilities or breaches. With Splunk’s advanced search and reporting capabilities, users can create custom dashboards and alerts to detect suspicious activities. Automated searches can flag endpoints exhibiting unusual behavior, while correlation analysis can identify links between compromised devices and broader network vulnerabilities. In particular, Splunk's machine learning capabilities can be leveraged to predict and prevent threats by identifying trends that might otherwise be missed in traditional log analysis. This proactive approach to monitoring VPN logs allows for the early detection of security weaknesses, enabling rapid response and minimizing potential damage to network integrity. By enhancing endpoint visibility, Splunk plays a crucial role in securing remote connections and safeguarding sensitive information. Additionally, Splunk’s automation and alerting features allow teams to create custom workflows that notify them of vulnerable or misconfigured endpoints identified through Shodan. This synergy between Splunk’s log analysis and Shodan’s device intelligence enhances an organization’s ability to proactively identify and mitigate security risks, improving the overall resilience of their VPN infrastructure.

97 MATHEMATICS AND COMPUTING↗

Guideline for Single-Event Effect (SEE) Testing of System on a Chip (SOC) Devices

The use of complex single and multicore processors with significant cache memory, on-chip peripherals, memory controllers, and high speed input/output (IO) that integrate many of the parts of a traditional computer system is becoming more common in space applications. Such devices are often referred to as system on a chip devices (SOCs), even though the term is used somewhat inaccurately due to the lack of analog and mixed signal subcircuits. These devices are complex combinations of single- or multi-core processors with memory controllers, high-speed input/output (IO), and other peripheral structures that formerly would have been handled by off-chip resources. In the past the processors were tested for single event effects (SEE) separately, and the peripherals were often put into custom application-specific integrated circuits (ASICs) along with other resources required by the user. Performance and cost pressures have pushed commercial devices to incorporate many of the functional blocks into a single chip, an SOC. The NASA Electronic Parts and Packaging Program (NEPP) has been examining ways to perform SEE radiation hardness assurance (RHA) testing of these processor-centric SOCs to achieve reasonable understanding of their performance in space missions.

Guertin, Steven M.↗

The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors

We introduce a Xilinx RF System-on-Chip (RFSoC)-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short), which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC field-programmable gate array, custom firmware, and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average gate fidelity of ℱ avg =99.93%. All of the schematics, firmware, and software are open-source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

XMOS XC-2 Development Board for Mechanical Control and Data Collection

The scanning microwave limb sounder (SMLS) will use technological improvements in low-noise mixers to provide precise data on the Earth s atmospheric composition with high spatial resolution. This project focuses on the design and implementation of a realtime control system needed for airborne engineering tests of the SMLS. The system must coordinate the actuation of optical components using four motors with encoder readback, while collecting synchronized telemetric data from a GPS receiver and 3-axis gyrometric system. A graphical user interface for testing the control system was also designed using Python. Although the system could have been implemented with an FPGA(fieldprogrammable gate array)-based setup, a processor development kit manufactured by XMOS was chosen. The XMOS architecture allows parallel execution of multiple tasks on separate threads, making it ideal for this application. It is easily programmed using XC (a subset of C). The necessary communication interfaces were implemented in software, including Ethernet, with significant cost and time reduction compared to an FPGA-based approach. A simple approach to control the chopper, calibration mirror, and gimbal for the airborne SMLS was needed. The XMOS board allows for multiple threads and real-time data acquisition. The XC-2 development kit is an attractive choice for synchronized, real-time, event-driven applications. The XMOS is based on the transputer microprocessor architecture developed for parallel computing, which is being revamped in this new platform. The XMOS device has multiple cores capable of running parallel applications on separate threads. The threads communicate with each other via user-defined channels capable of transmitting data within the device. XMOS provides a C-based development environment using XC, which eliminates the need for custom tool kits associated with FPGA programming. The XC-2 has four cores and necessary hardware for Ethernet I/O.

Jarnot, Robert F.↗

Automating Microbial Directed Evolution For Bioengineering Applications

From a micro-biology perspective, directed evolution is a technique that uses controlled environmental pressures to select for a desired phenotype. Directed evolution has the distinct advantage over rational design of not needing extensive knowledge of the genome or pathways associated with a microorganism to induce phenotypes. However, there are currently limitations to the applicability of this technique including being time-consuming, error-prone, and dependent on existing assays that may lack selectivity for the given phenotype. The AADEC (Autonomous Adaptive Directed Evolution Chamber) system is a proof-of-concept instrument to automate and improve the technique such that directed evolution can be used more effectively as a general bioengineering tool. A series of tests using the automated system and comparable by-hand survival assay measurements have been carried out using UV-C radiation and Escherichia coli cultures in order to demonstrate the advantages of the AADEC versus traditional implementations of directed evolution such as random mutagenesis. AADEC uses UV-C exposure as both a source of environmental stress and mutagenesis, so in order to evaluate the UV-C tolerance obtained from the cultures, a manual UV-C exposure survival assay was developed alongside the device to compare the survival fractions at a fixed dosage. This survival assay involves exposing E. coli to UV-C radiation using a custom-designed exposure hood to control the flux and dose. Surviving cells are counted then transferred to the next iteration and so on for several iterations to calculate the survival fractions for each exposure iteration.This survival assay primarily serves as a baseline for the AADEC device, allowing quantification of the differences between the AADEC system over the manual approach. The primary data of comparison is survival fractions; this is obtained by optical density and plate counts in the manual assay and by optical density growth curve fits pre- and post-exposure in the automated case. This data can then be compiled to calculate trends over the iterations to characterize increasing UV-C resistance of the E.coli strains. The observed trends are statistically indistinguishable through several iterations from both sources.

Bioengineering↗

Tiny Devices Project Sharp, Colorful Images

Displaytech Inc., based in Longmont, Colorado and recently acquired by Micron Technology Inc. of Boise, Idaho, first received a Small Business Innovation Research contract in 1993 from Johnson Space Center to develop tiny, electronic, color displays, called microdisplays. Displaytech has since sold over 20 million microdisplays and was ranked one of the fastest growing technology companies by Deloitte and Touche in 2005. Customers currently incorporate the microdisplays in tiny pico-projectors, which weigh only a few ounces and attach to media players, cell phones, and other devices. The projectors can convert a digital image from the typical postage stamp size into a bright, clear, four-foot projection. The company believes sales of this type of pico-projector may exceed $1.1 billion within 5 years.

Source record↗

A systolic architecture for the correlation and accumulation of digital sequences

A fully systolic architecture for the implementation of digital sequence correlator/accumulators is described. These devices consist of a two-dimensional array of processing elements that are conceived for efficient fabrication in Very Large Scale Integrated (VLSI) circuits. A custom VLSI chip that was implemented using these concepts is described. The chip, which contains a four-lag three-level sequence correlator and four bits of accumulation with overflow detection, was designed using the Integrated UNIX-Based Computer Aided Design (CAD) System. Applications of such devices include the synchronization of coded telemetry data, alignment of both real time and non-real time Very Large Baseline Interferometry (VLBI) signals, and the implementation of digital filters and processes of many types.

Deutsch, L. J.↗

Smart Semi-Supervised Accumulation of Large Repositories for Industrial Control Systems Device Information

Industrial Control Systems device manufacturers frequently add new features to improve their product performance. Oftentimes, these changes are mainly vendor-driven initiatives, and customers may not be aware of the full impact of these new capabilities on their cybersecurity posture. In the energy sector, this can lead to considerable dissonance between vendor-provided cybersecurity claims and a customer’s responsibility for Operation Technology cybersecurity compliance. Thus, the resulting dynamic verification burden is shifted towards the customer and may pose a significant cybersecurity risk to the energy sector landscape. We found that there is very limited research into cybersecurity auditing for Operational Technology. However, a solution is needed for vetting the vendor-supplied feature claims and their adherence to cybersecurity requirements and standards. We are presently engaged in an effort to develop such a system. This paper demonstrates one vital aspect of this effort in proposing an end-to-end framework to accumulate a large repository of ICS device information for this vetting system, curate the dataset, and conduct extensive processing. This framework is designed to use web scraping, data analytics and Natural Language Processing (NLP) techniques to identify vendor websites, automate the collection of website-accessible documents and automatically derive metadata from them for identification of product documents relevant to the repository. We have found that this automated approach to vendor identification, document extraction into a product repository, and NLP pre-processing is unique and has not been previously presented in the literature. The preliminary work shows that this is feasible and can produce reliable results with minimum supervision. Future work will be built upon this foundation in order to achieve semi-supervised vetting of device technical information – a vital capability for ensuring that vendor-claimed device cybersecurity capabilities match industry requirements.

Ameri, Kimia↗

Detector Control and Data Acquisition for the Wide-Field Infrared Survey Telescope (WFIRST) with a Custom ASIC

The Wide-Field Infrared Survey Telescope (WFIRST) will have the largest near-IR focal plane ever flown by NASA, a total of 18 4K x 4K devices. The project has adopted a system-level approach to detector control and data acquisition where 1) control and processing intelligence is pushed into components closer to the detector to maximize signal integrity, 2) functions are performed at the highest allowable temperatures, and 3) the electronics are designed to ensure that the intrinsic detector noise is the limiting factor for system performance. For WFIRST, the detector arrays operate at 90 to 100 K, the detector control and data acquisition functions are performed by a custom ASIC at 150 to 180 K, and the main data processing electronics are at the ambient temperature of the spacecraft, notionally approx.300 K. The new ASIC is the main interface between the cryogenic detectors and the warm instrument electronics. Its single-chip design provides basic clocking for most types of hybrid detectors with CMOS ROICs. It includes a flexible but simple-to-program sequencer, with the option of microprocessor control for more elaborate readout schemes that may be data-dependent. All analog biases, digital clocks, and analog-to-digital conversion functions are incorporated and are connected to the nearby detectors with a short cable that can provide thermal isolation. The interface to the warm electronics is simple and robust through multiple LVDS channels. It also includes features that support parallel operation of multiple ASICs to control detectors that may have more capability or requirements than can be supported by a single chip.

data acquisition↗

Topological superconductivity in skyrmion lattices

Atomic manipulation and interface engineering techniques have provided an intriguing approach to custom-designing topological superconductors and the ensuing Majorana zero modes, representing a paradigm for the realization of topological quantum computing and topology-based devices. Magnet-superconductor hybrid (MSH) systems have proven to be experimentally suitable to engineer topological superconductivity through the control of both the complex structure of its magnetic layer and the interface properties of the superconducting surface. Here, we demonstrate that two-dimensional MSH systems containing a magnetic skyrmion lattice provide an unprecedented ability to control the emergence of topological phases. By changing the skyrmion radius, which can be achieved experimentally through an external magnetic field, one can tune between different topological superconducting phases, allowing one to explore their unique properties and the transitions between them. In these MSH systems, Josephson scanning tunneling spectroscopy spatially visualizes one of the most crucial aspects underlying the emergence of topological superconductivity, the spatial structure of the induced spin–triplet correlations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Miniature housing with standard addressable interface for smart sensors and drive electronics

A miniature assembly is disclosed which includes a housing assembly with a cover configured to be sealably secured to a box-like receptacle. The receptacle comprises openings on opposing sides for the seating therein of communications connectors. Enclosed within housing is custom-sized circuit board for supporting, at least, a standard communications interface and at least one electronic device.

Howard, David E.↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra Wide Bandgap Laser Addressable Photoconductors

Wide Band Gap (WBG) and Ultra Wide Band Gap (UWBG) photoconductors have the potential to meet several critical mission needs for LLNL and the broader USG due to their exceptional characteristics related to large critical electric field. In particular, high energy laser systems such as the National Ignition Facility would benefit from the development of new materials for active optical devices such as the Optically Addressable Light Valve (OALV) used in the Programmable Spatial Shaper System. Missions in Global Security would benefit from higher performance Photoconductive Semiconductor Switches for pulsed power and radiofrequency amplifiers. This project examined the suitability of both commercially available and custom synthesized semi insulating WBG and UWBG materials for several of these applications. We developed high laser damage threshold OALVs for optical systems based on several of these materials as well as new RF, pulsed power, and power electronics devices based on the same. These devices show superior power handling in terms of laser damage threshold, electric field, and power output. A number of the technologies developed have been transitioned to both internal and external customers.

42 ENGINEERING↗

Applying queueing theory to evaluate wait-time-savings of triage algorithms

Abstract In the past decade, artificial intelligence (AI) algorithms have made promising impacts in many areas of healthcare. One application is AI-enabled prioritization software known as computer-aided triage and notification (CADt). This type of software as a medical device is intended to prioritize reviews of radiological images with time-sensitive findings, thus shortening the waiting time for patients with these findings. While many CADt devices have been deployed into clinical workflows and have been shown to improve patient treatment and clinical outcomes, quantitative methods to evaluate the wait-time-savings from their deployment are not yet available. In this paper, we apply queueing theory methods to evaluate the wait-time-savings of a CADt by calculating the average waiting time per patient image without and with a CADt device being deployed. We study two workflow models with one or multiple radiologists (servers) for a range of AI diagnostic performances, radiologist’s reading rates, and patient image (customer) arrival rates. To evaluate the time-saving performance of a CADt, we use the difference in the mean waiting time between the diseased patient images in the with-CADt scenario and that in the without-CADt scenario as our performance metric. As part of this effort, we have developed and also share a software tool to simulate the radiology workflow around medical image interpretation, to verify theoretical results, and to provide confidence intervals for the performance metric we defined. We show quantitatively that a CADt triage device is more effective in a busy, short-staffed reading setting, which is consistent with our clinical intuition and simulation results. Although this work is motivated by the need for evaluating CADt devices, the evaluation methodology presented in this paper can be applied to assess the time-saving performance of other types of algorithms that prioritize a subset of customers based on binary outputs.

Thompson, Yee Lam Elim (ORCID:0000000196537707)↗

The modern high rate digital cassette recorder

The magnetic tape recorder has played an essential role in the capture and storage of instrumentation data for more than thirty years. During this time, data recording technology has steadily progressed to meet user demands for more channels, wider bandwidths, and longer recording durations. When acquisition and processing moved from analog to digital techniques, so recorder design followed suit. Milestones marking the evolution of the data recorder through these various stages - multi-track analog, high density longitudinal digital, and more recently rotary digital - have often represented important breakthroughs in the handling of ever-greater quantities of data. Throughout this period there has been a very clear line of demarcation between data storage methods in the 'instrumentation world' on the one hand and the 'computer peripheral world' on the other. This is despite the fact that instrumentation data, whether analog or digital at the point of acquisition, is now likely to be processed on a digital computer at some stage. Regardless of whether the processing device is a small personal computer, a workstation, or the largest supercomputer, system integrators have traditionally been faced with the same basic problem - how to interface what is essentially a manually controlled, continuously running device (the tape recorder) into the fast start/stop computer environment without resorting to an excessive amount of complex custom interfacing and performance compromise. The increasing availability of affordable high power processing equipment throughout the scientific world is forcing recorder manufacturers to make their latest and perhaps most important breakthrough - the computer-friendly data recorder. The operating characteristics of such recorders are discussed and the resultant impact on both data acquisition and data analysis elements of system configuration are considered.

Clemow, Martin↗

A Novel Laser 3D Printing Method for the Advanced Manufacturing of Protonic Ceramics

Protonic ceramics (PCs) with high proton conductivity at intermediate temperatures (300–600 °C) have attracted many applications in energy conversion and storage devices such as PC fuel/electrolysis cells, PC membrane reactors, hydrogen pump, hydrogen or water-permeable membranes, and gas sensors. One of the essential steps for fulfilling the practical utilization of these intermediate-temperature PC energy devices is the successful development of advanced manufacturing methods for cost-effectively and rapidly fabricating them with high energy density and efficiency in a customized demand. In this work, we developed a new laser 3D printing (L3DP) technique by integrating digital microextrusion-based 3D printing and precise and rapid laser processing (sintering, drying, cutting, and polishing), which showed the capability of manufacturing PCs with desired complex geometries, crystal structures, and microstructures. The L3DP method allowed the fabrication of PC parts such as pellets, cylinders, cones, films, straight/lobed tubes with sealed endings, microchannel membranes, and half cells for assembling PC energy devices. The preliminary measurement of the L3DP electrolyte film showed a high proton conductivity of ≈7 × 10−3 S/cm. This L3DP technique not only demonstrated the potential to bring the PCs into practical use but also made it possible for the rapid direct digital manufacturing of ceramic-based devices.

08 HYDROGEN↗

A Review of Existing Test Methods for Occupancy Sensors

One of the key new features of connected lighting systems (CLS) is their ability to collect data from various types of integral sensors and share that data with other lighting or building systems. Occupancy and vacancy sensors have been widely adopted as an energy-saving strategy in buildings, yet published test methods for reproducibly characterizing their performance remain few and limited in their sophistication. As a result, it has been difficult to predict their performance in a specific application, and in practice, they frequently do not meet energy-savings expectations. Occupants at times remove or otherwise bypass occupancy sensors that hinder their work or otherwise do not perform as expected, thereby compromising the sensors’ potential to reduce energy consumption. Poor performance can result from multiple causes – ranging from fundamental limitations of the sensor technology, to misconfiguration, to poor placement in the room or space. Innovative occupancy sensors, some of them combining multiple sensing technologies, have come on the market over the years, with claims of improved performance compared to their predecessors; yet in practice, their performance has led to neither high deployment nor high user satisfaction in any significant application, nor has it differed enough from the performance of previous products to necessitate a test method that facilitated comparison between them. While the performance of both common and novel occupancy sensors has been the subject of many published research articles, the test methods that have been employed for them have typically been loosely described and incorporated custom equipment or techniques that render them difficult to reproduce, or have been limited in their ability to fairly characterize devices that utilize varying sensor technology. The lack of a well-described, technology-agnostic test method that yields reproducible results across different implementations has been a barrier to the commercial success of new occupancy sensor products, as users and specifiers who have been disappointed with previous products are often unwilling to take a chance with new ones. Motivated by a desire to fairly characterize new technologies that continue to enter the market and claim not only improved occupancy detection but, in some cases, also additional capabilities (e.g., the ability to measure traffic or discern between different object types), this report presents the results of a literature review of recent published, well-described test methods for characterizing occupancy sensor performance, as well as research articles containing ad-hoc test methods. The review also identifies and consolidates the best techniques for characterizing sensor performance in indoor spaces and identifies test method gaps that need to be filled in order to evaluate emerging technologies and products.

47 OTHER INSTRUMENTATION↗