Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “custom”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Developing A Custom-Built Metal Aerosol Processing Chamber: Analysis of Aerosol Coagulation at Low Humidities

We have developed an intermediate size (906 L) aerosol processing chamber, and this work reports on the design and initial characterization of dry aerosol experiments. Specifically, we are determining wall-loss and coagulation correction factors using the observed size distribution measurements for surrogates of common aerosol classes: sodium chloride, sucrose, and biomass burning aerosol smoke. Results show that, on average, sodium chloride, sucrose, and smoke wall-loss rates converge to similar values on relatively short time scales (< 1 h). The fitted coagulation correction factor, W C -1 , for smoke particles (1.23 ± 0.312), indicates that on average they adhere to each other more than sodium chloride (0.969 ± 0.524) and sucrose (1.16 ± 1.38). The relative uncertainty is high for the coagulation correction, but it is consistent with our Monte Carlo error analysis. This study lays the foundation for future experiments at elevated humidity and supersaturation conditions to characterize the influence of particle shape on coagulation and cloud parameters.

54 ENVIRONMENTAL SCIENCES↗

Electric component including custom metal grain orientation

An electrical device includes an electromagnetic component configured to generate a magnetic flux. The electromagnetic component includes a soft magnetically-conductive material configured to pass magnetic flux therethrough along a flux path. The soft magnetically-conductive material includes at least one grain oriented portion having metal grains that are oriented parallel with respect to the magnetic flux.

42 ENGINEERING↗

Assessing Cost-Optimal Battery Energy and Solar-Plus-Storage Systems for Federal Customers: A Nationwide Assessment: Preprint

Prior research has identified that the financial viability of behind-the-meter battery energy storage systems is heavily dependent on technology cost, utility rate structure, energy consumption patterns, and co-deployment with synergistic technologies like solar photovoltaics (PV), among other factors. This study builds on existing research by comprehensively evaluating the economics of battery energy storage systems (BESS) and solar-plus-storage systems for a reference office building at 755 reference sites under 834 utility rates, and four storage capital cost scenarios. Results indicate that even with dramatic cost reductions, BESS is likely to be cost-effective only under utility rates that include demand charges, and possibly include time-of-use (TOU) pricing as well. Even under these utility rates, BESS systems provide marginal savings, and office building operators are unlikely to deploy the technology for cost savings alone. Solar-plus-storage systems provide more savings than BESS and allow for larger economic storage capacities. Solar-plus-storage provides compelling savings opportunities at baseline prices, and even at capital costs 25% higher than baseline. Solar-plus-storage is most effective where there are demand charges and energy pricing schemes include TOU pricing, or where electricity is expensive (at least $0.30/kWh). Our case studies illustrate that the presence of demand charges, even at similar energy costs, can be the deciding factor in BESS and solar-plus-storage viability. The findings and maps from this assessment may be of use to planners, building owners, and developers looking for potentially economic storage opportunities.

battery energy storage systems↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements: Preprint

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric component including custom metal grain orientation

An electrical device includes an electromagnetic component configured to generate a magnetic flux. The electromagnetic component includes a soft magnetically-conductive material configured to pass magnetic flux therethrough along a flux path. The soft magnetically-conductive material includes at least one grain oriented portion having metal grains that are oriented parallel with respect to the magnetic flux.

42 ENGINEERING↗

Systems and methods for customizing kernel machines with deep neural networks

A method including receiving an input data set. The input data set can include one of a feature domain set or a kernel matrix. The method also can include constructing dense embeddings using: (i) Nyström approximations on the input data set when the input data set comprises the kernel matrix, and (ii) clustered Nyström approximations on the input data set when the input data set comprises the feature domain set. The method additionally can include performing representation learning on each of the dense embeddings using a multi-layer fully-connected network for each of the dense embeddings to generate latent representations corresponding to each of the dense embeddings. The method further can include applying a fusion layer to the latent representations corresponding to the dense embeddings to generate a combined representation. The method additionally can include performing classification on the combined representation. Other embodiments of related systems and methods are also disclosed.

Song, Huan↗