Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “currents”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Evaluation of Ferrite Chip Beads as Surge Current Limiters in Circuits with Tantalum Capacitors

Limiting resistors are currently required to be connected in series with tantalum capacitors to reduce the risk of surge current failures. However, application of limiting resistors decreases substantially the efficiency of the power supply systems. An ideal surge current limiting device should have a negligible resistance for DC currents and high resistance at frequencies corresponding to transients in tantalum capacitors. This work evaluates the possibility of using chip ferrite beads (FB) as such devices. Twelve types of small size FBs from three manufacturers were used to evaluate their robustness under soldering stresses and at high surge current spikes associated with transients in tantalum capacitors. Results show that FBs are capable to withstand current pulses that are substantially greater than the specified current limits. However, due to a sharp decrease of impedance with current, FBs do not reduce surge currents to the required level that can be achieved with regular resistors.

surge current testing↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Bond of steel-mortar interface interfered by stray current

Highlights: • The focus of this work is to present test results on the bond of steel-mortar interface undergoing stray current; • The bond strength is correlated to the electrochemical response of the steel-mortar interface; • The effects of duration of curing and starting point of stray current are also investigated; • This work also differentiates the effects of stray current on steel-mortar bond versus anodic polarization. The focus of this work is to present test results on the bond of steel-mortar interface undergoing stray current. The bond strength, derived by pull-out tests, is correlated to the electrochemical response of the steel rebar and the properties of the mortar bulk matrix. The effects of curing regimes (in terms of duration of curing) and starting point of stray current are also investigated. It is found that stray current exerts bond degradation of the steel-mortar interface in all investigated cases, irrespective of the presence or absence of a corrodent (Cl{sup −}) in the external medium. For the ease of operation in lab tests, the stray current is generally simulated by anodic polarization, although fundamentally, the stray current effect on the steel surface is composed of both anodic and cathodic polarizations. Hence this work also differentiates the effects of stray current on steel-mortar bond, versus the effects of anodic polarization.

36 MATERIALS SCIENCE↗

Limiting Current in Nanostructured Block Copolymer Electrolytes

The next-generation electrolytes for lithium batteries must be able to conduct ions at sufficiently high current densities; yet this regime is rarely studied directly. The limiting current density of an electrolyte quantifies the highest possible rate of ion transport under an applied dc potential. Herein, we report on the limiting current density in twelve nanostructured polystyrene-block-poly(ethylene oxide) (PS-b-PEO, or SEO) copolymer electrolytes. We find that the limiting current at a given salt concentration increases systematically with increasing volume fraction of the PEO block (φ EO ). In contrast, the effective-medium theory, commonly used to analyze conductivity in block copolymer electrolytes, predicts that limiting current is independent of φ EO . To resolve this conundrum, the ionic conductivity, the mutual diffusion coefficient of the salt, and the steady-state current fraction of the block copolymer electrolytes were measured. These measurements enable predictions of limiting current with no adjustable parameters using the concentrated solution theory. We found quantitative agreement between experimentally measured limiting current densities and predictions based on the concentrated solution theory. This work sheds light on how to reliably measure and predict limiting current density in composite electrolytes.

25 ENERGY STORAGE↗

Observation of a new type of self-generated current in magnetized plasmas

A tokamak, a torus-shaped nuclear fusion device, needs an electric current in the plasma to produce magnetic field in the poloidal direction for confining fusion plasmas. Plasma current is conventionally generated by electromagnetic induction. However, for a steady-state fusion reactor, minimizing the inductive current is essential to extend the tokamak operating duration. Several non-inductive current drive schemes have been developed for steady-state operations such as radio-frequency waves and neutral beams. However, commercial reactors require minimal use of these external sources to maximize the fusion gain, Q, the ratio of the fusion power to the external power. Apart from these external current drives, a self-generated current, so-called bootstrap current, was predicted theoretically and demonstrated experimentally. Here, we reveal another self-generated current that can exist in a tokamak and this has not yet been discussed by present theories. We report conclusive experimental evidence of this self-generated current observed in the KSTAR tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vanadium oxide coatings to self-regulate current sharing in high-temperature superconducting cables and magnets

High-temperature superconductors such as REBa 2 Cu 3 O 7-δ (REBCO, RE = rare earth) enable high-current cables and high-field magnets. By removing the turn-to-turn insulation in a magnet application, recent experiments demonstrated that REBCO magnets can self-protect against catastrophic damage during a superconducting-to-normal transition (quench), i.e., when the stored magnetic energy rapidly converts to heat. The current can bypass the hot spot during a quench, thereby reducing the localized heat dissipation. The removal of the insulation between turns, however, leads to excessive eddy currents during current ramping, thereby forcing a much-prolonged magnet charging time. To address this issue, we investigate vanadium oxide (VO x ) coatings as a temperature-dependent self-switching medium that automatically manages current sharing. VO x coatings (with 1.70 ≤ × ≤ to 2.07) were deposited by reactive cathodic arc deposition, initially on insulating glass to determine the electrical properties, and later on commercial REBCO tapes. The coatings are x-ray amorphous but with a short-range crystalline ordering according to Raman spectrometry. The resistivity of VO x decreased by at least three orders of magnitude when the temperature increased from 80 to 300 K. The coating process is compatible with commercial REBCO tapes as evidenced by the negligible change in the critical current caused by the coating process. Here, the results from current sharing experiments and circuit analysis suggest that the VO x coating can effectively self-regulate current sharing in REBCO magnets, suppress excessive eddy currents, and enable self-protection during quenches.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Current potential patches

A novel form of the current potential, a mathematical tool for the design of stellarators and stellarator coils, is developed. Specifically, these are current potentials with a finite-element basis, called current potential patches. Current potential patches leverage the relationship between distributions of magnetic dipoles and current potentials to explore limits of the access properties of stellarator coil sets. An example calculation is shown using the Helically Symmetric Experiment (HSX) equilibrium, demonstrating the method's use in coil design and understanding the limits of the access properties of coil sets. Current potential patches have additional desirable properties such as of promoting sparse current sheet solutions and identifying crucial locations of shaping current placement. A result is found for the HSX equilibrium that shaping currents covering only 22% of the winding surface are sufficient to produce the equilibrium to a good accuracy, provided a toroidal field is generated by an exterior coil set.

Elder, Todd↗

Limiting current in a collisional crossed-field gap

Crossed-field devices are often used in pulsed power and high-power microwave applications. Previous studies derived closed-form solutions for the limiting current of a vacuum crossed-field system, corresponding to the maximum permissible current for laminar flow, below and above the Hull cutoff B H for magnetic insulation. We extend these studies by introducing collision frequency into the electron force law as a friction term to derive the limiting current in a collisional crossed-field gap. The resulting solution recovers the vacuum crossed-field case in the limit of no collisions and the collisional space-charge limited current with general initial velocity for magnetic field B → 0. In the limit of infinite collisions, we obtain a crossed-field equivalent to the Mott–Gurney law for the maximum current permissible in a collisional, nonmagnetic diode. When the collision frequency ν is less than the electron cyclotron frequency Ω, increasing initial velocity makes the critical current nonmonotonic with increasing ν with the critical current higher at B = B H for ν = Ω. As for a misaligned crossed-field gap where a component of the magnetic field was introduced parallel to the electric field across the gap, magnetic insulation is eliminated and the discontinuity at B = B H for limiting current observed in a vacuum crossed-field gap vanishes. As B → ∞, the limiting current approaches a constant that depends on the initial velocity and the collision frequency.

Breen, Lorin I.↗

A Two-Stage Current Limiting Control Strategy for Direct-Droop-Controlled Grid-Forming Inverters

This paper presents a two-stage current limiting control strategy with fault ride-through capability for the direct-droop-controlled grid-forming (GFM) inverters. The proposed approach comprises Stage 1 and Stage 2 current limiting controls. During faults, Stage 1 current limiting control instantly clamps the inverter output current magnitude to its maximum transient limit by blocking the switching pulses to the insulated-gate bipolar transistors (IGBTs) with the help of a hysteresis loop control, and Stage 2 current limiting control limits the inverter output current magnitude to its steady-state limit by regulating the amplitude and frequency of the modulating waveform utilizing the active and reactive current limiting control loops. By implementing the current limiting actions in two stages, this approach can effectively limit the over-current within a few cycles after the fault occurrence and ensure synchronism to the grid after long-term fault events. The efficacy of the proposed control approach is validated through electromagnetic transient (EMT) simulation results conducted on a single GFM inverter-based test system and the IEEE 39-bus test system with multiple GFM inverters in the PSCAD platform.

Mohiuddin, Sheik Mohammad↗

The Influence of Carbon Fiber Composite Specimen Design Parameters on Artificial Lightning Strike Current Dissipation and Material Thermal Damage

Previous artificial lightning strike direct effect research has examined a broad range of specimen design parameters. No works have studied how such specimen design parameters and electrical boundary conditions impact the dissipation of electric current flow through individual plies. This article assesses the influence of carbon fiber composite specimen design parameters (design parameters = specimen size, shape, and stacking sequence) and electrical boundary conditions on the dissipation of current and the spread of damage resulting from Joule heating. Thermal-electric finite element (FE) modelling is used and laboratory scale (<1 m long) and aircraft scale (>1 m long) models are generated in which laminated ply current dissipation is predicted, considering a fixed artificial lightning current waveform. The simulation results establish a positive correlation between the current exiting the specimen from a given ply and the amount of thermal damage in that ply. The results also establish that the distance to ground, from the strike location to the zero potential boundary conditions (ground), is the controlling factor which dictates the electric current dissipation in each ply. Significantly, this distance to ground is dependent on each of the specimen shape, dimensions, stacking sequence, and location of ground boundary conditions. Therefore, it is not possible to decouple current dissipation and damage from specimen design and boundary condition setup. However, it is possible to define a specimen size for a given specimen shape, stacking sequence, and waveform which limit the influence of specimen dimensions on the resulting current distribution and damage. For a rectangular specimen design which appears in literature multiple times, as 100 × 150 mm and with a stacking sequence of [45/0/-45/90] 4s , a specimen design of greater than 300 × 200 mm is required to limit the influence of specimen dimensions on current distribution and damage.

36 MATERIALS SCIENCE↗

Rocket-based vector magnetic measurements of Sq ionospheric currents near sporadic E.

A rocket-borne vector magnetometer has been used to infer the current magnitude, direction, and distribution of midlatitude ionospheric currents near sporadic E. Complete vector information returned throughout the flight indicates that a southward equivalent surface current (vertically integrated current) of 0.15 amp/m was encountered between the altitudes of 104 and 118 km in both ascending and descending portions of the flight. Vertical distribution of the current within the layer was approximately uniform, and the layer was found to be horizontal within the accuracy of the experiment. The data are consistent with the assumption that a sporadic-E layer observed by Wallops Island ionosondes significantly altered the usual Sq current flow pattern by concentrating the current into a narrow altitude range, and by horizontally focusing the current flow into the sporadic-E region with attendant reduction of current density outside the region.

Cloutier, P. A.↗

Measurements of field-aligned currents in a multiple auroral arc system

A rocket-borne experiment to study the currents associated with a system of multiple auroral arcs was conducted at Poker Flat, Alaska, at 1122 UT on Feb. 2, 1972. The magnetic field in the vicinity of the auroral system was measured with a cesium vector magnetometer. Possible configurations were inferred by constructing model current systems that reproduced the magnetic field variations measured along the flight path. The data are interpreted in terms of a model current system consisting of two eastward electrojets and one westward electrojet and three pairs of oppositely directed Birkeland sheet currents, all lying in a plane approximately parallel to the auroral arcs. Sheet thicknesses ranged from 20 to 60 km and current densities from 10 to 45 microampere/sq m; the electrojet currents ranged from 1000 to 2000 A. A possible alternate model consisted of four pairs of sheets whose thicknesses range from 10 to 40 km with current densities from 10 to 90 microampere/sq m. There was quite good agreement between the locations of the visual arcs and the upward current sheets. The overall current configuration is discussed in view of the theoretical models constructed by Atkinson and Sato and Holzer and of other observations.

Sesiano, J.↗

A comparison of coronal and interplanetary current sheet inclinations

The HAO white light K-coronameter observations show that the inclination of the heliospheric current sheet at the base of the corona can be both large (nearly vertical with respect to the solar equator) or small during Cararington rotations 1660 - 1666 and even on a single solar rotation. Voyager 1 and 2 magnetic field observations of crossing of the heliospheric current sheet at distances from the Sun of 1.4 and 2.8 AU. Two cases are considered, one in which the corresponding coronameter data indicate a nearly vertical (north-south) current sheet and another in which a nearly horizontal, near equatorial current sheet is indicated. For the crossings of the vertical current sheet, a variance analysis based on hour averages of the magnetic field data gave a minimum variance direction consistent with a steep inclination. The horizontal current sheet was observed by Voyager as a region of mixed polarity and low speeds lasting several days, consistent with multiple crossings of a horizontal but irregular and fluctuating current sheet at 1.4 AU. However, variance analysis of individual current sheet crossings in this interval using 1.92 see averages did not give minimum variance directions consistent with a horizontal current sheet.

Behannon, K. W.↗

A comparison of coronal and interplanetary current sheet inclinations

The HAO white light K-coronameter observations show that the inclination of the heliospheric current sheet at the base of the corona can be both large (nearly vertical with respect to the solar equator) or small during Cararington rotations 1660 - 1666 and even on a single solar rotation. Voyager 1 and 2 magnetic field observations of crossing of the heliospheric current sheet at distances from the sun of 1.4 and 2.8 AU. Two cases are considered, one in which the corresponding coronameter data indicate a nearly vertical (north-south) current sheet and another in which a nearly horizontal, near equatorial current sheet is indicated. For the crossings of the vertical current sheet, a variance analysis based on hour averages of the magnetic field data gave a minimum variance direction consistent with a steep inclination. The horizontal current sheet was observed by Voyager as a region of mixed polarity and low speeds lasting several days, consistent with multiple crossings of a horizontal but irregular and fluctuating current sheet at 1.4 AU. However, variance analysis of individual current sheet crossings in this interval using 1.92 see averages did not give minimum variance directions consistent with a horizontal current sheet. Previously announced in STAR as N83-31566

Behannon, K. W.↗

Three-dimensional Birkeland-ionospheric current system, determined from MAGSAT

The relationship of Birkeland currents and ionospheric currents has been determined from MAGSAT magnetic field observations. A two-dimensional ionospheric current analysis using a Fourier technique has been used to study several MAGSAT orbits on March 21, 1980. The use of the MAGSAT data allows an extensive ionospheric current system to be matched directly to the inferred Birkeland current system without the aid of a conductivity model (this is not the case with Birkeland currents deduced from surface magnetic field measurements). The results include electrojet current distributions that are generally triangular with peak intensity at the center and, in some cases, more complicated distributions associated with equally complicated Birkeland currents. The Birkeland currents generally occupy the same latitudes as do the electrojets, and the Region 1-Region 2 boundary is located near the center of the electrojet.

Zanetti, L. J.↗

Rotationally-induced Birkeland current systems

Rotational effects which are negligible in earth's magnetosphere become dominant in the magnetospheres of the outer planets where they give rise to Birkeland current circuits coupling the ionospheric and magnetospheric motions. The centrifugal force of corotation produces an azimuthal ring current in the magnetosphere while the Coriolis force produces a current parallel to the plasma flow. The acceleration current also becomes significant when deviations from strict corotation are appreciable. In general, none of these currents are divergence-free, and closure is provided by ionospheric conduction currents via connecting Birkeland currents. Thus the ionospheric conductivity regulates magnetospheric motions much as it does in the terrestrial case. The effects of such currents have been clearly observed in the magnetospheres of Jupiter and Saturn. Birkeland current circuits also transmit planetary angular momentum to external sinks such as conducting satellites (e.g., Io), plasma production sites (e.g., the Io torus), and/or the surrounding solar wind (as proposed for Uranus).

Hill, T. W.↗

DE 1 observations of type 1 counterstreaming electrons and field-aligned currents

Dynamics Explorer 1 satellite observations of plasma and magnetic fields during type one counterstreaming electron events are presented. Counterstreaming electrons are observed at high altitudes in the region of field-aligned current. The total current density computed from the plasma data in the 18-10,000 eV energy range is generally about 1-2 micro-A/sq m. For the downward current, low-energy electrons contribute more than 40 percent of the total plasma current density integrated above 18 eV. For the upward current, such electrons contribute less than 50 percent of that current density. Electron beams in the field-aligned direction are occasionally detected. The pitch angle distributions of counterstreaming electrons are generally enhanced at both small and large pitch angles. STARE simultaneous observations for one DE 1 pass indicated that the field-aligned current was closed through Pedersen currents in the ionosphere. The directions of the ionospheric current systems are consistent with the DE 1 observations at high altitudes.

Lin, C. S.↗