Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Airborne and Ground-Based Measurements Using a High-Performance Raman Lidar

A high-performance Raman lidar operating in the UV portion of the spectrum has been used to acquire, for the first time using a single lidar, simultaneous airborne profiles of the water vapor mixing ratio, aerosol backscatter, aerosol extinction, aerosol depolarization and research mode measurements of cloud liquid water, cloud droplet radius, and number density. The Raman Airborne Spectroscopic Lidar (RASL) system was installed in a Beechcraft King Air B200 aircraft and was flown over the mid-Atlantic United States during July August 2007 at altitudes ranging between 5 and 8 km. During these flights, despite suboptimal laser performance and subaperture use of the telescope, all RASL measurement expectations were met, except that of aerosol extinction. Following the Water Vapor Validation Experiment Satellite/Sondes (WAVES_2007) field campaign in the summer of 2007, RASL was installed in a mobile trailer for groundbased use during the Measurements of Humidity and Validation Experiment (MOHAVE-II) field campaign held during October 2007 at the Jet Propulsion Laboratory s Table Mountain Facility in southern California. This ground-based configuration of the lidar hardware is called Atmospheric Lidar for Validation, Interagency Collaboration and Education (ALVICE). During theMOHAVE-II field campaign, during which only nighttime measurements were made, ALVICE demonstrated significant sensitivity to lower-stratospheric water vapor. Numerical simulation and comparisons with a cryogenic frost-point hygrometer are used to demonstrate that a system with the performance characteristics of RASL ALVICE should indeed be able to quantify water vapor well into the lower stratosphere with extended averaging from an elevated location like Table Mountain. The same design considerations that optimize Raman lidar for airborne use on a small research aircraft are, therefore, shown to yield significant dividends in the quantification of lower-stratospheric water vapor. The MOHAVE-II measurements, along with numerical simulation, were used to determine that the likely reason for the suboptimal airborne aerosol extinction performance during theWAVES_2007 campaign was amisaligned interference filter. With full laser power and a properly tuned interference filter,RASL is shown to be capable ofmeasuring themain water vapor and aerosol parameters with temporal resolutions of between 2 and 45 s and spatial resolutions ranging from 30 to 330 m from a flight altitude of 8 km with precision of generally less than 10%, providing performance that is competitive with some airborne Differential Absorption Lidar (DIAL) water vapor and High Spectral Resolution Lidar (HSRL) aerosol instruments. The use of diode-pumped laser technology would improve the performance of an airborne Raman lidar and permit additional instrumentation to be carried on board a small research aircraft. The combined airborne and ground-based measurements presented here demonstrate a level of versatility in Raman lidar that may be impossible to duplicate with any other single lidar technique.

Whiteman, David N.↗

SOMD LOX/Methane Assessment, Data Analysis Subteam: MOX-E Test Series Analysis Summary

Fundamental explosive testing was conducted by the NASA/MSFC Blast Team (N2L) to determine yields produced from cryogenic liquid mixtures of methane and oxygen for a range of oxygen-to-fuel ratios. The blast wave overpressure and high-speed video data were processed by the NASA led multi-agency data analysis team. This document serves to provide a summary of the optimized data analysis produced and the resulting conclusions regarding the yields achieved during this test program.

Combustion↗

Low-Cost Propellant Launch From a Tethered Balloon

A document presents a concept for relatively inexpensive delivery of propellant to a large fuel depot in low orbit around the Earth, for use in rockets destined for higher orbits, the Moon, and for remote planets. The propellant is expected to be at least 85 percent of the mass needed in low Earth orbit to support the NASA Exploration Vision. The concept calls for the use of many small ( 10 ton) spin-stabilized, multistage, solid-fuel rockets to each deliver 250 kg of propellant. Each rocket would be winched up to a balloon tethered above most of the atmospheric mass (optimal altitude 26 2 km). There, the rocket would be aimed slightly above the horizon, spun, dropped, and fired at a time chosen so that the rocket would arrive in orbit near the depot. Small thrusters on the payload (powered, for example, by boil-off gases from cryogenic propellants that make up the payload) would precess the spinning rocket, using data from a low-cost inertial sensor to correct for small aerodynamic and solid rocket nozzle misalignment torques on the spinning rocket; would manage the angle of attack and the final orbit insertion burn; and would be fired on command from the depot in response to observations of the trajectory of the payload so as to make small corrections to bring the payload into a rendezvous orbit and despin it for capture by the depot. The system is low-cost because the small rockets can be mass-produced using the same techniques as those to produce automobiles and low-cost munitions, and one or more can be launched from a U.S. territory on the equator (Baker or Jarvis Islands in the mid-Pacific) to the fuel depot on each orbit (every 90 minutes, e.g., any multiple of 6,000 per year).

Wilcox, Brian↗

Low-Cost, High-Performance Cryocoolers for In-Situ Propellant Production

A key feature of many In-Situ Resource Utilization (ISRU) schemes is the production of rocket fuel and oxidizer from the Martian atmosphere. Many of the fuels under consideration will require cryogenic cooling for efficient long-term storage. Although significant research has been focused on the techniques for producing the fuels from Martian resources, little effort has been expended on the development of cryocoolers to efficiently liquefy these fuels. This paper describes the design of a pulse tube liquefier optimized for liquefying oxygen produced by an In-Situ Propellant Production (ISPP) plant on Mars.

Martin, J. L.↗

Low-Cost High-Performance Cryocoolers for In-Situ Propellant Production

A key feature of many In-Situ Resource Utilization (ISRU) schemes is the production of rocket fuel and oxidizer from the Martian atmosphere. Many of the fuels under consideration will require cryogenic cooling for efficient long-term storage. Although significant research has been focused on the techniques for producing the fuels from Martian resources, little effort has been expended on the development of cryocoolers to efficiently liquefy these fuels. This paper describes the design of a pulse tube liquefier optimized for liquefying oxygen produced by an In-Situ Propellant Production (ISPP) plant on Mars.

Martin, J. L.↗

Long-Wave Infrared Dyson Spectrometer

Preliminary results are presented for an ultra compact long-wave infrared slit spectrometer based on the dyson concentric design. The dyson spectrometer has been integrated in a dewar environment with a quantum well infrared photodetecor (QWIP), concave electron beam fabricated diffraction grating and ultra precision slit. The entire system is cooled to cryogenic temperatures to maximize signal to noise ratio performance, hence eliminating thermal signal from transmissive elements and internal stray light. All of this is done while maintaining QWIP thermal control. A general description is given of the spectrometer, alignment technique and predicated performance. The spectrometer has been designed for optimal performance with respect to smile and keystone distortion. A spectral calibration is performed with NIST traceable targets. A 2-point non-uniformity correction is performed with a precision blackbody source to provide radiometric accuracy. Preliminary laboratory results show excellent agreement with modeled noise equivalent delta temperature and detector linearity over a broad temperature range.

imaging↗

Cryogenic cooling study for the advanced limb scanner

The cryogenic operating requirements for a VM refrigerator to be used for detector cooling of the advanced limb scanner (ALS) instrument are defined. Determination of these requirements include consideration of mission and environmental constraints. Based on the operating requirements a detailed refrigerator design and performance analysis is conducted resulting in an optimized VM refrigerator conceptual design. The cooler-instrument-spacecraft interfaces are evaluated resulting in recommendations as to the best approach and most effective concepts resulting in simple and satisfactory interfaces. A preliminary implementation plan and schedule describing the general tasks required to develop, design, manufacture, test, and deliver three VM coolers and required support equipment to support an ALS flight experiment are presented. The result of this effort shows that existing VM cooler technology is sufficient to satisfy ALS mission requirements and schedules.

Russo, S. C.↗

An integrated development facility for the calibration of low-energy charged particle flight instrumentation

A system was developed for the calibration and development of thermal ion instrumentation. The system provides an extended beam with usable current rates, approx. 1 pA/sq cm, at beam energies as low as 1 eV, with much higher values available with increasing energy. A tandem electrostatic and variable geometry magnetic mirror configuration within the ion source optimizes the use of the ionizing electrons. The system is integrated under microcomputer control to allow automatic control and monitoring of the beam energy and composition and the mass and angle-dependent response of the instrument under test. The system is pumped by a combination of carbon vane and cryogenic sorption roughing pumps and ion and liquid helium operating pumps.

Biddle, A. P.↗

Performance of the SBRC 190, a cryogenic multiplexer for photoconductor arrays

The SBRC 190 cryogenic readouts were developed for use with far-infrared arrays of Ge:Sb and Ge:Ga photoconductor detectors. The SBRC 190 provides an AC-coupled CTIA (capacitance transimpedance amplifier) unit cell for each detector and multiplexes up to 32 detectors. This paper presents our test results characterizing and optimizing the performance of these novel devices. We will discuss their basic behavior in addition to describing the trade-offs inherent in different sampling strategies.

Dotson, Jessie L.↗

The Role of Integrated Modeling in the Design and Verification of the James Webb Space Telescope

The James Web Space Telescope (JWST) is a large, infrared-optimized space telescope scheduled for launch in 2011. System-level verification of critical optical performance requirements will rely on integrated modeling to a considerable degree. In turn, requirements for accuracy of the models are significant. The size of the lightweight observatory structure, coupled with the need to test at cryogenic temperatures, effectively precludes validation of the models and verification of optical performance with a single test in 1-g. Rather, a complex series of steps are planned by which the components of the end-to-end models are validated at various levels of subassembly, and the ultimate verification of optical performance is by analysis using the assembled models. This paper describes the critical optical performance requirements driving the integrated modeling activity, shows how the error budget is used to allocate and track contributions to total performance, and presents examples of integrated modeling methods and results that support the preliminary observatory design. Finally, the concepts for model validation and the role of integrated modeling in the ultimate verification of observatory are described.

Mosier, Gary E.↗

Development of a distributed-parameter mathematical model for simulation of cryogenic wind tunnels

A one-dimensional distributed-parameter dynamic model of a cryogenic wind tunnel was developed which accounts for internal and external heat transfer, viscous momentum losses, and slotted-test-section dynamics. Boundary conditions imposed by liquid-nitrogen injection, gas venting, and the tunnel fan were included. A time-dependent numerical solution to the resultant set of partial differential equations was obtained on a CDC CYBER 203 vector-processing digital computer at a usable computational rate. Preliminary computational studies were performed by using parameters of the Langley 0.3-Meter Transonic Cryogenic Tunnel. Studies were performed by using parameters from the National Transonic Facility (NTF). The NTF wind-tunnel model was used in the design of control loops for Mach number, total temperature, and total pressure and for determining interactions between the control loops. It was employed in the application of optimal linear-regulator theory and eigenvalue-placement techniques to develop Mach number control laws.

Tripp, J. S.↗

Development and Testing of Femtosecond Laser Surface Processing (FLSP) Treated Guide Vanes for Application to Advanced Cryogenic Liquid Acquisition Devices

Liquid Acquisition Devices (LADs) are used inside propellant tanks in microgravity to collect liquid propellant to move towards the sump or outlet of a tank during expulsion or transfer. In microgravity, vehicle thrusters can produce necessary phase separation, but in the absence of thrust, surface tension is the driver of fluid behavior. Liquid in microgravity will tend to form a sphere to minimize surface area. If a LAD can be made more “attractive” to a propellant (omniphilic), then it should perform its function more effectively. This paper presents preliminary results on using femtosecond laser surface processing (FLSP) to change the wetting properties of a vane LAD. FLSP can make metals superhydrophilic or omniphilic; by controlling the applied laser parameters, the resulting micro and nanoscale surface features can be tailored to control and optimize hydrophilic/omniphilic properties. Two LAD galleries with guide vanes were recently fabricated, a control sample and an FLSP-treated sample. The LADs were ground tested and also implemented in a parabolic flight experiment. Based on contact angle and roll-off angle measurements of the surface-treated vane, FLSP appears to be a promising technique to improve efficiency of LADs

Liquid Acquisition Devices↗

Alignment Test Results of the JWST Pathfinder Telescope Mirrors in the Cryogenic Environment

After integration of the Optical Telescope Element (OTE) to the Integrated Science Instrument Module (ISIM) to become the OTIS, the James Webb Space Telescope OTIS is tested at NASAs Johnson Space Center (JSC) in the cryogenic vacuum Chamber A for alignment and optical performance. The alignment of the mirrors comprises a sequence of steps as follows: The mirrors are coarsely aligned using photogrammetry cameras with reflective targets attached to the sides of the mirrors. Then a multi-wavelength interferometer is aligned to the 18-segment primary mirror using cameras at the center of curvature to align reflected light from the segments and using fiducials at the edge of the primary mirror. Once the interferometer is aligned, the 18 primary mirror segments are then adjusted to optimize wavefront error of the aggregate mirror. This process phases the piston and tilt positions of all the mirror segments. An optical fiber placed at the Cassegrain focus of the telescope then emits light towards the secondary mirror to create a collimated beam emitting from the primary mirror. Portions of the collimated beam are retro-reflected from flat mirrors at the top of the chamber to pass through the telescope to the SI detector. The image on the detector is used for fine alignment of the secondary mirror and a check of the primary mirror alignment using many of the same analysis techniques used in the on-orbit alignment. The entire process was practiced and evaluated in 2015 at cryogenic temperature with the Pathfinder telescope.

Interferometer↗

Alignment Test Results of the JWST Pathfinder Telescope Mirrors in the Cryogenic Environment

After integration of the Optical Telescope Element (OTE) to the Integrated Science Instrument Module (ISIM) to become the OTIS, the James Webb Space Telescope OTIS is tested at NASAs Johnson Space Center (JSC) in the cryogenic vacuum Chamber A for alignment and optical performance. The alignment of the mirrors comprises a sequence of steps as follows: The mirrors are coarsely aligned using photogrammetry cameras with reflective targets attached to the sides of the mirrors. Then a multi-wavelength interferometer is aligned to the 18-segment primary mirror using cameras at the center of curvature to align reflected light from the segments and using fiducials at the edge of the primary mirror. Once the interferometer is aligned, the 18 primary mirror segments are then adjusted to optimize wavefront error of the aggregate mirror. This process phases the piston and tilt positions of all the mirror segments. An optical fiber placed at the Cassegrain focus of the telescope then emits light towards the secondary mirror to create a collimated beam emitting from the primary mirror. Portions of the collimated beam are retro-reflected from flat mirrors at the top of the chamber to pass through the telescope to the SI detector. The image on the detector is used for fine alignment of the secondary mirror and a check of the primary mirror alignment using many of the same analysis techniques used in the on-orbit alignment. The entire process was practiced and evaluated in 2015 at cryogenic temperature with the Pathfinder telescope.

OTIS↗

A 3D-printed Broadband Millimeter Wave Absorber

We present the design, manufacturing technique, and characterization of a 3D-printed broadband graded index millimeter wave absorber. The absorber is additively manufactured using a fused filament fabrication (FFF) 3D printer out of a carbon-loaded high impact polystyrene (HIPS) filament and is designed using a space-filling curve to optimize manufacturability using said process. The absorber's reflectivity is measured from 63 GHz to 115 GHz and from 150 GHz to 215 GHz and is compared to electromagnetic simulations. The intended application is for terminating stray light in Cosmic Microwave Background (CMB) telescopes, and the absorber has been shown to survive cryogenic thermal cycling.

Matthew Petroff↗

Parametric Analysis of the Charge-Hold-Vent Method for Cryogenic Propellant Tank Chill Down

In the absence of external heat exchangers, the on-orbit transfer of cryogenic propellants requires the receiver tank to first be quenched to a sufficiently low energy state to allow for a continuous no-vent fill to avoid unnecessary venting of liquid. One proposed method for tank chilldown that minimizes the potential for venting liquid is the charge hold vent (CHV) method. CHV follows a cyclic process that gradually removes thermal energy from the receiver tank by injecting liquid with the vent valve closed and allowing the fluid and wall to reach near-thermal equilibrium before venting the superheated vapor. However, the CHV method must be optimized to minimize complexity, mass, and time. This paper presents a modular CHV analytical model used to quantify the number of cycles and propellant mass consumed based on first principles. The model is used to examine the effect of eight parameters: receiver tank material, volume, mass, maximum expected operating pressure, and initial pressure, liquid injection pressure and temperature, and the target temperature. The model is validated against the only two available CHV datasets. Based on results, the tank mass-to-volume ratio is the most important factor in determining the number of CHV cycles and thus degree of difficulty in tank chilldown. The model can easily be used for early-stage design, sizing, and analysis of cryogenic propellant transfer systems.

Tank Chilldown↗

Parametric Analysis of the Charge-Hold-Vent Method for Cryogenic Propellant Tank Chill Down

Abstract. In the absence of external heat exchangers, the on-orbit transfer of cryogenic propellants requires the receiver tank to first be quenched to a sufficiently low energy state to allow for a continuous no-vent fill to avoid unnecessary venting of liquid. One proposed method for tank chilldown that minimizes the potential for venting liquid is the charge hold vent (CHV) method. CHV follows a cyclic process that gradually removes thermal energy from the receiver tank by injecting liquid with the vent valve closed and allowing the fluid and wall to reach near-thermal equilibrium before venting the superheated vapor. However, the CHV method must be optimized to minimize complexity, mass, and time. This paper presents a modular CHV analytical model used to quantify the number of cycles and propellant mass consumed based on first principles. The model is used to examine the effect of eight parameters: receiver tank material, volume, mass, maximum expected operating pressure, and initial pressure, liquid injection pressure and temperature, and the target temperature. The model is validated against the only two available CHV datasets. Based on results, the tank mass-to-volume ratio is the most important factor in determining the number of CHV cycles and thus degree of difficulty in tank chilldown. The model can easily be used for early-stage design, sizing, and analysis of cryogenic propellant transfer systems. Keywords: tank chilldown, charge-hold-vent, no-vent fill

Tank Chilldown↗

A large cooled infrared telescope facility for Spacelab

An optimized cooled IR telescope of 1 m aperture diameter will offer sensitivities over the 1 micron to 1 mm spectrum at least 1000 times greater than can be achieved from the ground in the atmospheric windows, and comparable sensitivities at wavelengths that are outside the windows. A study has shown that a cryogenically-cooled telescope of up to 1.6 m aperture diameter for Spacelab is feasible without new technology, although some development of detectors and scientific instruments to take advantage of the extreme sensitivity is indicated.-

Mccarthy, S. G.↗