Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coordinated control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

On the Minimum Induced Drag of Wings

Birds do not require the use of vertical tails. They do not appear to have any mechanism by which to control their yaw. As an example the albatross is notable in this regard. The authors believe this is possible because of a unique adaptation by which there exists a triple-optimal solution that provides the maximum aerodynamic efficiency, the minimum structural weight, and it provides for coordination of control in roll and yaw. Until now, this solution has eluded researchers, and remained unknown. Here it is shown that the correct specification of spanload provides for all three solutions at once, maximum aerodynamic efficiency, minimum structural weight, and coordinated control. The implications of this result has far reaching effects on the design of aircraft, as well as dramatic efficiency improvement.

flight mechanics↗

Dynamic coordination of two robot arms

This paper presents a new control method for coordinated control of two robot arms. The two arms are assumed to work on the same object simultaneously. The control method uses a dynamic coordinator acting on relative position and velocity task space errors and on relative force-torque errors between the two arms as sensed at the end effectors. This method is novel because the position and velocity error feedback could be superimposed with the force-torque error feedback in the task space simultaneously.

Tarn, T. J.↗

Integrated lift/drag controller for aircraft

A system for altering the lift/drag characteristics of powered aircraft to provide a safe means of glide path control includes a control device integrated for coordination action with the aircraft throttle. Such lift/drag alteration devices as spoilers, dive brakes, and the like are actuated by manual operation of a single lever coupled with the throttle for integrating, blending or coordinating power control. Improper operation of the controller is inhibited by safety mechanisms.

Olcott, J. W.↗

Numerical solution of flow problems using body-fitted coordinate systems

The paper deals with numerically generated boundary-fitted coordinate systems. This procedure eliminates the shape of the boundaries as a complicating factor and allows the flow about arbitrary boundaries to be treated essentially as easily as that about simple boundaries. The technique of boundary-fitted coordinate systems is based on a method of automatic numerical generation of a general curvilinear coordinate system having a coordinate line coincident with each boundary of a general multiconnected region involving any number of arbitrarily shaped boundaries. Once the curvilinear coordinate system is generated, any partial differential system of interest may be solved on the coordinate system by transforming the equations and solving the resulting system in finite-difference approximation on the rectangular transformed plane. Attention is given to the types of boundary-fitted coordinate systems, coordinate system control, operation of the coordinate codes, solution of partial differential equations, application to free-surface flow, and other applications of interest.

Thompson, J. F.↗

Solar Dynamic Power System Stability Analysis and Control

The objective of this research is to conduct dynamic analysis, control design, and control performance test of solar power system. Solar power system consists of generation system and distribution network system. A bench mark system is used in this research, which includes a generator with excitation system and governor, an ac/dc converter, six DDCU's and forty-eight loads. A detailed model is used for modeling generator. Excitation system is represented by a third order model. DDCU is represented by a seventh order system. The load is modeled by the combination of constant power and constant impedance. Eigen-analysis and eigen-sensitivity analysis are used for system dynamic analysis. The effects of excitation system, governor, ac/dc converter control, and the type of load on system stability are discussed. In order to improve system transient stability, nonlinear ac/dc converter control is introduced. The direct linearization method is used for control design. The dynamic analysis results show that these controls affect system stability in different ways. The parameter coordination of controllers are recommended based on the dynamic analysis. It is concluded from the present studies that system stability is improved by the coordination of control parameters and the nonlinear ac/dc converter control stabilize system oscillation caused by the load change and system fault efficiently.

Momoh, James A.↗

Coordination Between Sectors in Shared Airspace Operations

Recent studies have shown that a more efficient use of airspace may involve shared airspace operations, i.e., temporal as well as spatial separation of arrival and departure flows [1][2]. Temporal separation would permit a departure aircraft to fly through an arrival flow, depending on an available gap. This would necessitate careful and precise coordination between controllers in different sectors. Three methods of coordination which permit the penetration of a controller's airspace by another controller's aircraft are described: point out, look-and-go, and prearranged coordination procedure. Requirements of each method are given, along with associated problems that have surfaced in the field as described by Aviation Safety and Reporting System (ASRS) and other reports. A Human-in-the-Loop simulation was designed to compare two of the methods: point out and prearranged coordination procedures. In prearranged coordination procedures (P-ACP), the controllers control an aircraft in another controller's airspace according to specified prearranged procedures, without coordinating each individual aircraft with another controller, as is done with point outs. In the simulation, three experienced controllers rotated through two arrival sectors and a non-involved arrival sector of a Terminal Radar Approach Control (TRACON) airspace. Results of eighteen one-hour simulation runs (nine in each of the two conditions) showed no impact of the coordination method on separation violations nor on arrival times for 208 departing aircraft crossing an arrival stream. Participant assessment indicated that although both coordination conditions were acceptable, the prearranged coordination procedure condition was slightly safer, more efficient, timely, and overall, worked better operationally. Problems arose in the point out condition regarding controllers noticing acceptance of point outs. Also, in about half of the point-out runs, time pressure was felt to have had an impact on when and if the departures could cross an arrival stream. An additional problem with point outs may be confusion in the field about which controller has responsibility for separating point-out aircraft from other aircraft.

Parke, Bonny↗

Grid-Interactive Electric Vehicle and Building Coordination Using Coupled Distributed Control: Preprint

As an increasing number of controllable devices are introduced onto the grid, they can individually provide ancillary services in support of grid stability. However, the goals of each device differ due to their type and individual objectives, causing instances where they may conflict. To reduce the chances of these devices contributing to grid instability, these devices must effectively communicate in a cooperative manner to both meet their own needs while providing services to the grid. Previous work demonstrates that the NALD (Network Lasso-ADMM - Limited Communication - DMPC) algorithm allows coordination between two subsystems that use different control algorithms (building and charging stations) to provide services to the grid and individually optimize their performance in a specific scenario. The ideal NALD algorithm should be generalized to allow plug-and-play capabilities across devices of differing characteristics. This paper takes a step toward generalizability by updating the electric vehicle charging objective and re-defining the communication scheme compared to prior work to generalize the coordination and, as a result, improve the performance of the NALD algorithm.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

An Intelligent Propulsion Control Architecture to Enable More Autonomous Vehicle Operation

This paper describes an intelligent propulsion control architecture that coordinates with the flight control to reduce the amount of pilot intervention required to operate the vehicle. Objectives of the architecture include the ability to: automatically recognize the aircraft operating state and flight phase; configure engine control to optimize performance with knowledge of engine condition and capability; enhance aircraft performance by coordinating propulsion control with flight control; and recognize off-nominal propulsion situations and to respond to them autonomously. The hierarchical intelligent propulsion system control can be decomposed into a propulsion system level and an individual engine level. The architecture is designed to be flexible to accommodate evolving requirements, adapt to technology improvements, and maintain safety.

autonomy↗

An Intelligent Propulsion Control Architecture to Enable More Autonomous Vehicle Operation

This paper describes an intelligent propulsion control architecture that coordinates with the flight control to reduce the amount of pilot intervention required to operate the vehicle. Objectives of the architecture include the ability to: automatically recognize the aircraft operating state and flight phase; configure engine control to optimize performance with knowledge of engine condition and capability; enhance aircraft performance by coordinating propulsion control with flight control; and recognize off-nominal propulsion situations and to respond to them autonomously. The hierarchical intelligent propulsion system control can be decomposed into a propulsion system level and an individual engine level. The architecture is designed to be flexible to accommodate evolving requirements, adapt to technology improvements, and maintain safety.

autonomy↗

Telerobotic control of a mobile coordinated robotic server, executive summary

This interim report continues with the research effort on advanced adaptive controls for space robotics systems. In particular, previous results developed by the principle investigator and his research team centered around fuzzy logic control (FLC) in which the lack of knowledge of the robotic system as well as the uncertainties of the environment are compensated for by a rule base structure which interacts with varying degrees of belief of control action using system measurements. An on-line adaptive algorithm was developed using a single parameter tuning scheme. In the effort presented, the methodology is further developed to include on-line scaling factor tuning and self-learning control as well as extended to the multi-input, multi-output (MIMO) case. Classical fuzzy logic control requires tuning input scale factors off-line through trial and error techniques. This is time-consuming and cannot adapt to new changes in the process. The new adaptive FLC includes a self-tuning scheme for choosing the scaling factors on-line. Further the rule base in classical FLC is usually produced by soliciting knowledge from human operators as to what is good control action for given circumstances. This usually requires full knowledge and experience of the process and operating conditions, which limits applicability. A self-learning scheme is developed which adaptively forms the rule base with very limited knowledge of the process. Finally, a MIMO method is presented employing optimization techniques. This is required for application to space robotics in which several degrees-of-freedom links are commonly used. Simulation examples are presented for terminal control - typical of robotic problems in which a desired terminal point is to be reached for each link. Future activities will be to implement the MIMO adaptive FLC on an INTEL microcontroller-based circuit and to test the algorithm on a robotic system at the Mars Mission Research Center at North Carolina State University.

Lee, Gordon↗

Co-Simulation Model for Optimal Wind-Hydro Coordination Using Wind Farm Control Dynamics

The growing share of Variable Renewable Energy sources (VRES) in power systems presents challenges for regula- tors, grid operators and energy producers. The VRES’ operation has limited flexibility in their operations, as they are highly dependent on ambient environments. To address these challenges, decision-makers must consider multiple objectives, among these are revenue, power system services and mechanical load on wind turbines. Coordinated operation of power plants and different wind farm control strategies are examples of measures that can benefit these objectives. This study proposes a Multi-Objective Linear Programming (MOLP) model to simulate the optimum operation of wind and hydropower plants that share limited transmission capacity. Further, wind farm control dynamics are included to obtain realistic output power and accumulated damage. From this, a case study based on a relevant location in Norway is presented to analyze the improved effect of wind- hydro coordination and wind farm control in achieving the objectives of accumulated wind turbine damage and total revenue of the hybrid power system. In addition, the study considers the potential advantages of adding a variable-speed pump to the hydropower plant. The results demonstrate that by considering multiple objectives in the optimization, one may achieve better overall performance of the objectives. By utilizing the flexibility of hydro storage, the decision maker may adjust to obtain the most desired outcome. Moreover, the added flexibility of utilizing a pump for hydro storage shows great improvements for the combined revenue of the power plants and reduced curtailment of the wind farm. However, less impact is observed from using a variable speed pump compared to a fixed speed pump.

13 HYDRO ENERGY↗

Fine-tuned local coordination environment of Pt single atoms on ceria controls catalytic reactivity

Constructing single atom catalysts with fine-tuned coordination environments can be a promising strategy to achieve satisfactory catalytic performance. Herein, via a simple calcination temperature-control strategy, CeO 2 supported Pt single atom catalysts with precisely controlled coordination environments are successfully fabricated. The joint experimental and theoretical analysis reveals that the Pt single atoms on Pt 1 /CeO 2 prepared at 550 °C (Pt/CeO 2 -550) are mainly located at the edge sites of CeO 2 with a Pt–O coordination number of ca. 5, while those prepared at 800 °C (Pt/CeO 2 -800) are predominantly located at distorted Ce substitution sites on CeO 2 terrace with a Pt–O coordination number of ca. 4. Pt/CeO 2 -550 and Pt/CeO 2 -800 with different Pt 1 -CeO 2 coordination environments exhibit a reversal of activity trend in CO oxidation and NH 3 oxidation due to their different privileges in reactants activation and H 2 O desorption, suggesting that the catalytic performance of Pt single atom catalysts in different target reactions can be maximized by optimizing their local coordination structures.

36 MATERIALS SCIENCE↗

TokenPasser: A petri net specification tool

In computer program design it is essential to know the effectiveness of different design options in improving performance, and dependability. This paper provides a description of a CAD tool for distributed hierarchical Petri nets. After a brief review of Petri nets, Petri net languages, and Petri net transducers, and descriptions of several current Petri net tools, the specifications and design of the TokenPasser tool are presented. TokenPasser is a tool to allow design of distributed hierarchical systems based on Petri nets. A case study for an intelligent robotic system is conducted, a coordination structure with one dispatcher controlling three coordinators is built to model a proposed robotic assembly system. The system is implemented using TokenPasser, and the results are analyzed to allow judgment of the tool.

Mittmann, Michael↗

Performance Evaluation of Peer-to-Peer Distributed Microgrids Coordination for Voltage Regulation

This paper presents the performance evaluation of a peer-to-peer microgrids coordination algorithm for sub-transmission systems. As distributed energy resources (DERs) in distribution system start to show negative impact to the bulk power system, a paradigm shift is needed for transmission planning and operation. Because distribution substations are located far from the sub-transmission system, and it is hard to use traditional centralized control for real-time control and coordination. Thus, distributed control is a natural choice because it requires less communication and central computation. In this paper, each distribution substation is treated as a microgrid, and the peer-to-peer distributed microgrids control is formulated as a real-time optimal power flow problem to reduce the negative impact in sub-transmission systems. A distributed primal-dual optimization algorithm is adopted to solve the problem. Validation of the peer-to-peer algorithm is performed through the simulation of a real-world sub-transmission system composing of many distribution systems with high renewable penetration. Simulation results show that the peer-to-peer algorithm can achieve satisfactory performance (e.g., voltage regulation) in sub-transmission system by coordinating and controlling DERs in distribution systems.

distributed control↗

Performance Evaluation of Peer-to-Peer Distributed Microgrids Coordination for Voltage Regulation: Preprint

This paper presents the performance evaluation of a peer-to-peer microgrids coordination algorithm for sub-transmission systems. As distributed energy resources (DERs) in distribution system start to show negative impact to the bulk power system, a paradigm shift is needed for transmission planning and operation. Because distribution substations are located far from the sub-transmission system, and it is hard to use traditional centralized control for real-time control and coordination. Thus, distributed control is a natural choice because it requires less communication and central computation. In this paper, each distribution substation is treated as a microgrid, and the peer-to-peer distributed microgrids control is formulated as a real-time optimal power flow problem to reduce the negative impact in sub-transmission systems. A distributed primal-dual optimization algorithm is adopted to solve the problem. Validation of the peer-to-peer algorithm is performed through the simulation of a real-world sub-transmission system composing of many distribution systems with high renewable penetration. Simulation results show that the peer-to-peer algorithm can achieve satisfactory performance (e.g., voltage regulation) in sub-transmission system by coordinating and controlling DERs in distribution systems.

distributed control↗