Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Analysis of data user's needs for performance evaluation of solar heating and cooling systems

In a successful data acquisition program, the information needs must be evaluated, the design and cost factors of the program must be determined, and a data management loop must be organized and operated in order to collect, process, and disseminate the needed information in useable formats. This paper describes each of these program elements in detail as an aid for the solar heating and cooling data manager and user to implement effective data acquisition and monitoring systems. Consideration is given to the development of evaluation techniques which will aid in the determination of solar energy systems performances.

Christensen, D. L.↗

Cooling systems for satellite remote sensing instrumentation

The current and developing state-of-the-art in cryogenic coolers for satellite sensors was studied for earth oriented satellites. Six representative sensor categories in the 77 K to 300 K range were defined. Cooling capacities were 50 to 1000 mw; both continuous and intermittent duty cycles were considered; lifetimes were one to two years. Conceptual designs were prepared for the most promising coolers in each category. These coolers are Joule-Thomson, Solid Cryogen, Vuilleumier, Thermoelectric, Shielded Radiator, Optical Solar Reflector Radiator and Unshielded Radiator. Weight, envelope, power requirements and operating characteristics of each cooler are described. Scaling data for each cooler are included.

Copeland, R. J.↗

A study of central cryogenic cooling system for the comet rendezvous spacecraft

Several science instruments required temperatures between 100 K and 120 K on a proposed Halley Flyby, Tempel-2 Rendezvous Mission. Significant features of the thermal environment are a large variation in heliocentric as well as comet distance, very large solar panels for a Solar Electric Propulsion stage, and the comet dust environment. The best cooling is achieved by one central radiative cooler connected by insulated cryogenic heat pipes to the instruments. The conceptual design is of a single-stage rectangular shielded radiator deployed on a boom some distance from the spacecraft bus and solar panels. Thermal modeling determined sensitivity to solar and comet distance and was used to optimize cooler geometry.

Salazar, R. P.↗

Seasonal Host Shifts for Legionella Within an Industrial Water‐Cooling System

Legionella is a genus of environmental bacteria containing pathogenic species such as Legionella pneumophila that are responsible for Legionnaires' disease, a potentially fatal respiratory infection. Disease aetiology can involve Legionella replication intracellularly within protists and this study aimed to characterise the Legionella -protist relationship to develop novel outbreak prevention targets. Water and sediment samples were collected from a water-cooling tower in South Carolina over a 6-month period. Concomitantly, multiple environmental parameters were recorded. Bacterial and eukaryotic communities were characterised using 16S rRNA gene V4 region and a 252 bp fragment of 18S rRNA gene, respectively. Co-occurrence network analyses were performed to elucidate Legionella -protist correlations through time. We found that Legionella correlated with different protists as the seasons progressed. Acanthamoeba correlated with Legionella in early spring followed by Vannella and Korotnevella in late spring and early summer, and were joined by Echinamoeba in mid-summer. Vannella and Acanthamoeba are known potential hosts for Legionella , while Korotnevella is a potential undocumented host. Of the environmental parameters, temperature showed strong correlation with protists genera, suggesting that Legionella abundance was driven by temperature-dependent protist availability. Our results highlight ecological shifts that are associated with elevated Legionella levels, which offers potential targets to help predict and prevent disease outbreaks.

microbial communities↗

Design of Refractory Metal Heat Pipe Life Test Environment Chamber, Cooling System, and Radio Frequency Heating System

A series of 16 Mo-44.5%Re alloy/sodium heat pipes will be experimentally tested to examine heat pipe aging. To support this evaluation, an environmental test chamber and a number of auxiliary subsystems are required. These subsystems include radio frequency (RF) power supplies/inductive coils, recirculation water coolant loops, and chamber gas conditioning. The heat pipes will be grouped, based on like power and gas mixture requirements, into three clusters of five units each, configured in a pentagonal arrangement. The highest powered heat pipe will be tested separately. Test chamber atmospheric purity is targeted at <0.3 ppb oxygen at an approximate operating pressure of 76 torr (.1.5 psia), maintained by active purification (oxygen level is comparable to a 10(exp -6) torr environment). Treated water will be used in two independent cooling circuits to remove .85 kW. One circuit will service the RF hardware while the other will maintain the heat pipe calorimetry. Initial procedures for the startup and operation of support systems have been identified. Each of these subsystems is outfitted with a variety of instrumentation, integrated with distributed real-time controllers and computers. A local area network provides communication between all devices. This data and control network continuously monitors the health of the test hardware, providing warning indicators followed by automatic shutdown should potentially damaging conditions develop. During hardware construction, a number of checkout tests.many making use of stainless steel prototype heat pipes that are already fabricated.will be required to verify operation.

Martin, J. J.↗

Thermal analysis and design of a cooling system for a Mach 14 nozzle

The analysis and design of a Mach 14 converging diverging nozzle wall liner is provided. The analysis indicates that: no fin on the coolant side of the nozzle wall is optimum, the thermal stresses are dominant, and the critical area is very near the throat. The molybdenum alloy TZM, with a wall thickness of 2.0 mm in the throat area, appears to be the only material capable of meeting design requirements. Additionally, cooling water at 2000 psia with a flow velocity of 25 m/s in the coolant passages is required.

Mullisen, Ronald↗

Oil cooling system for a gas turbine engine

A gas turbine engine fuel delivery and control system is provided with means to recirculate all fuel in excess fuel control requirements back to the aircraft fuel tank. This increases the fuel pump heat sink and decreases the pump temperature rise without the addition of valving other than normally employed. A fuel/oil heat exchanger and associated circuitry is provided to maintain the hot engine oil in heat exchange relationship with the cool engine fuel. Where anti-icing of the fuel filter is required, means are provided to maintain the fuel temperature entering the filter at or above a minimum level to prevent freezing thereof. In one embodiment, a divider valve is provided to take all excess fuel from either upstream or downstream of the fuel filter and route it back to the tanks, the ratio of upstream to downstream extraction being a function of fuel pump discharge pressure.

Coffinberry, G. A.↗

Full-scale study of the cooling system aerodynamics of an operating piston engine installed in a light aircraft wing panel

Measurements of the drag and of the nacelle internal pressures on a wing and nacelle that housed a horizontally opposed piston engine were made in the 40- by 80-Foot Wind Tunnel at Ames Research Center. These tests are follow-ons to earlier tests made with the same wing and nacelle but in which the engine was replaced with an electric motor and an adjustable orifice plate. In the initial tests the orifice plate was used to control the rate of cooling-air flow through the nacelle and thereby to simulate a range of gasoline engine types. Good agreement was found between the results of those tests and of the test reported here. Also, the upper and lower plenum pressure and cooling-air flow rate were found to be related by conventional equations used to represent the flow through orifices. Tests were run with three cooling air inlet sizes over a free-stream velocity range from 50 to 150 knots, an angle of attack range from 0 deg to 10 deg, and a cowl-flap deflection range from 0 deg to 30 deg. The data were analyzed by computing a flow coefficient similar to that used in the analysis of orifices. It was found that all of the flow coefficient values fell within a band that varied linearly with inlet area. The linear mean line through this band provides an estimate of the relationship between cooling-air flow rate and upper plenum pressure over a wide range of test conditions.

Corsiglia, V. R.↗

A Cooling System for the EAPU Shuttle Upgrade

The Shuttle orbiter currently uses hydrazine-powered APU's for powering its hydraulic system pumps. To enhance vehicle safety and reliability, NASA is pursuing an APU upgrade where the hydrazine powered turbine is replaced by an electric motor pump and battery power supply. This EAPU (Electric APU) upgrade presents several thermal control challenges most notably the new requirement for moderate temperature control of high-power electron ics at 132 of (55.6 C). This paper describes how the existing Water Spray Boiler (WSB), which currently cools the hydraulic fluid and APU lubrication oil, is being modified to provide EAPU thermal management.

Tongue, Stephen↗

Spacesuit Water Membrane Evaporator; An Enhanced Evaporative Cooling Systems for the Advanced Extravehicular Mobility Unit Portable Life Support System

Spacesuit Water Membrane Evaporator - Baseline heat rejection technology for the Portable Life Support System of the Advanced EMU center dot Replaces sublimator in the current EMU center dot Contamination insensitive center dot Can work with Lithium Chloride Absorber Radiator in Spacesuit Evaporator Absorber Radiator (SEAR) to reject heat and reuse evaporated water The Spacesuit Water Membrane Evaporator (SWME) is being developed to replace the sublimator for future generation spacesuits. Water in LCVG absorbs body heat while circulating center dot Warm water pumped through SWME center dot SWME evaporates water vapor, while maintaining liquid water - Cools water center dot Cooled water is then recirculated through LCVG. center dot LCVG water lost due to evaporation (cooling) is replaced from feedwater The Independent TCV Manifold reduces design complexity and manufacturing difficulty of the SWME End Cap. center dot The offset motor for the new BPV reduces the volume profile of the SWME by laying the motor flat on the End Cap alongside the TCV.

Bue, Grant C.↗

Integrated Transpiration and Lattice Cooling Systems developed by Additive Manufacturing with Oxide-Dispersion-Strengthened (ODS) Alloys (Final Report)

The primary goal of this research was to develop an innovative approach to provide a significantly improved level of thermal protection for hot-section components, such as turbine airfoils, in modern and future gas turbines. Current and future designs for “air breathing” turbine systems are targeting turbine inlet temperatures of 1700°C or higher, which is well beyond the substrate melting temperature, and a combined cycle energy efficiency of 65%. Meanwhile, targeted cycle efficiency calls for a reduction of the amount of coolant air significantly below the current level. Hence the development of novel internal airfoil designs that provide a satisfactory level of component durability with affordable coolant management is critical to the further advances of today’s turbine technology. This project was a response to this grand challenge with the research efforts primarily focused on the development of integrating transpiration cooling with lattice enhanced internal cooling. The research on these advanced cooling technologies was accompanied with development of anti-oxidation material in the form of oxide dispersion strengthened (ODS) alloy which also possessed enhanced high temperature strength. A novel approach of fabricating the ODS alloy as powder with high compatibility with state-of-the-art additive manufacturing (AM) process was also developed.

03 NATURAL GAS↗

Field evaluation of zone temperature response to control actions in cooling systems of small and medium-sized office buildings

The response of zone temperature to control actions in heating, ventilation, and air conditioning (HVAC) systems, known as zone temperature response, has been a central focus of building control research owing to its crucial role in determining control performance. However, existing studies often overlook the representativeness of the buildings being studied, resulting in unclear generalizations. In addition, those studies tend to focus on a single aspect of the response. Furthermore, this paper provides the first comprehensive characterization of zone temperature response applicable to a clearly defined building sector—small and medium-sized office (SMO) buildings (<5000 m 2 ) in the US. Specifically, two representative SMO buildings, selected based on the US Department of Energy’s commercial prototype buildings, were studied. Field tests were conducted over a 2-month period during summer, and the collected data were analyzed with two key metrics—delay time and nonlinearity index—to quantify zone temperature response, capturing both short- and long-term patterns. Beyond this quantitative characterization, the analysis reveals that the HVAC system type, rather than factors like floor area or zone location, is the primary determinant of the zone temperature response. Drawing on the field test results, we recommend that building control strategies monitor zone temperatures at intervals shorter than 10 minutes, configure controls independently for VAV- and RTU-served zones, and implement nonlinear methods at the zone level—particularly for VAV zones—rather than across the entire building.

Building control↗