Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conservation of intensity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

GreenThrift: Optimizing Carbon and Cost for Flexible Residential Loads

Reducing buildings’ carbon emissions is an important sustainability challenge. While scheduling flexible building loads has been previously used for a variety of grid and energy optimizations, carbon footprint reduction using such flexible loads poses new challenges since such methods need to balance both energy and carbon costs while also reducing user inconvenience from delaying such loads. This paper highlights the potential conflict between electricity prices and carbon emissions and the resulting trade-offs in carbon-aware and cost-aware load scheduling. To address this trade-off, we propose GreenThrift, a home automation system that leverages the scheduling capabilities of smart appliances and knowledge of future carbon intensity and cost to reduce both the carbon emissions and costs of flexible energy loads. At the heart of GreenThrift is an optimization technique that automatically computes schedules based on user configurations and preferences. We evaluate the effectiveness of GreenThrift using real-world carbon intensity data, electricity prices, and load traces from multiple locations and across different scenarios and objectives. Our results show that GreenThrift can replicate the offline optimal and retains 97% of the savings when optimizing the carbon emissions. Moreover, we show how GreenThrift can balance the conflict between carbon and cost and retain 95.3% and 85.5% of the potential carbon and cost savings, respectively.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usage

To ensure that new residential air conditioners and heat pumps operate optimally, care must be taken during the initial system design and installation to avoid missteps that immediately degrade a system’s performance. Laboratory and simulation studies have quantified the impact that faults can have on capacity and efficiency. Field studies have demonstrated that installation-related faults are commonplace. However, the national impact of installation-related faults cannot be accurately estimated by only simulating a limited number of homes at several fault levels because of the variety of home characteristics and climates involved. In our analysis, we use an improved residential building stock simulation tool to predict the annual energy increase and additional utility costs resulting from two common installation faults: indoor airflow rate and refrigerant charge level. Our method considers the wide range of building characteristics and climate zones of the U.S. housing stock. We use existing field data to develop fault intensity probability distributions to inform our analysis. The study shows that these two faults result in approximately 20.7 TWh/y of additional energy use for central air conditioners and air-source heat pumps in U.S. single-family detached homes, which is a 9% increase over baseline (no-fault) usage, costing homeowners approximately $2.5 billion annually on utility bills. Air-source heat pumps are responsible for a disproportionate fraction of this energy use increase because of the larger number of operating hours compared to central air conditioners and the sensitivity of heating mode performance to the faults analyzed compared to cooling mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application Potential of a Dew-Point Cooling Tower in Selected Energy Intensive Applications in Temperate Climate

In the article, the application potential of the dew-point cooling tower (DPCT) in selected energy-intensive applications in temperate climates was analyzed and discussed. The applications selected for analysis are power generation with natural gas turbines and chilled water air conditioning systems. The study is based on a mathematical model derived from a modified ε-NTU model. The model was validated against experimental results and showed satisfactory agreement with the experimental data. DPCT was compared with a typical cooling tower limited by the wet-bulb temperature (wet-bulb cooling tower, WBCT). The simulation results showed that DPCT is able to provide significant energy savings in energy-intensive applications; therefore, its application potential in temperate climates can be considered justified. In the case of gas turbines, DPCT was able to generate 2 to 10 percentage points more capacity than operating on outdoor air and 1.8 to 5 percentage points more than operating with WBCT. In the case of air conditioning systems, the system equipped with DPCT achieved EERs (energy efficiency ratios) higher by 1 to 7.2 compared to dry cooling and by 0.3 to 5.1 compared to systems equipped with WBCT. The annual energy savings obtained by the system with DPCT were 14.7 MWh compared to WBCT and 30 MWh compared to dry cooling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RapidClave Technology Demonstrations-II Kevlar Composite Vehicle Floor

This Demonstration’s objective was to develop enhanced methods to produce a complex preform comprised of Kevlar fabric and thermoplastic adhesive and rapidly consolidate the preform into the desired functional shape of a vehicular floor protection system. The approach and outcome goals were to reduce the tooling cost by 50% and shorten the processing time by 50% using the RapidClave® to consolidate the part rather than an autoclave. UDRI partnered with O’Gara Armoring who currently produces one piece Kevlar floor composite laminates that offer enhanced impact resistance at lighter weights as compared to steel. These laminates are constructed by hand layup of 3000 denier K29 fiber in a plain weave architecture with a thermoplastic film adhesive layer manufactured by Barrday and will be referred to as semi-preg throughout this paper. The current process is labor intensive and costly. Current production rates are only about one per month but an improved process is expected to enable product growth. A 50% reduction in tooling cost was achieved through the use of additive tooling, and the RapidClave® process enabled a 60% reduction in cycle time. Further cost savings were realized through the implementation of a preforming process that resulted in a 65% reduction in labor hours. This new approach for manufacturing reinforced vehicle floors has been partially implemented by O’Gara with plans to continue work on additional vehicle models. The cost savings has potential for increasing O’Gara’s production to reach new markets, and lead to job creation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand Response in Industrial Facilities: Peak Electric Demand

The US Department of Energy’s (DOE’s) Better Buildings, Better Plants Program (Better Plants) is a voluntary energy efficiency leadership initiative for US manufacturers and water/wastewater entities. The program encourages organizations to commit to reducing the energy intensity of their US operations over a 10-year period, typically by 25%. Companies joining Better Plants are recognized by DOE for their leadership in implementing energy efficiency practices and for reducing their energy intensity. Better Plants Partners are assigned to a Technical Account Manager, who can help companies establish energy intensity baselines, develop energy management plans, and identify key resources and incentives from DOE, other federal agencies, states, utilities, and other organizations that can enable them to reach their goals. Better Plants Partners are expected to report their progress to DOE once a year. This involves establishing an energy intensity baseline upon joining the program and then tracking their progress over time. Demand Response in Industrial Facilities: Peak Electrical Demand is intended to help companies understand peak demand response programs offering by their local utility. Manufacturing industries can learn about time-varying rates and smart technologies they can use to help them reduce their energy bills. This guidance document is applicable to companies participating at either the program or challenge level. Although this guide is intended primarily to assist companies participating in Better Plants, the methodologies and guidance within the document are applicable to any organization interested in understanding peak demand response programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decarbonization pathways for the residential sector in the United States

We report residential GHG emissions in the United States are driven in part by a housing stock where onsite fossil combustion is common, home sizes are large by international standards, energy efficiency potential is large and electricity generation in many regions is GHG intensive. In this analysis, we assess decarbonization pathways for the US residential sector to 2060, through 108 scenarios describing housing stock evolution, new housing characteristics, renovation levels and clean electricity. The lowest emission pathways involve very rapid decarbonization of electricity supply alongside extensive renovations to existing homes, including improving thermal envelopes and heat pump electrification of heating. Reducing the size and increasing the electrification of new homes provide further emission cuts and combining all strategies enables reductions of 91% between 2020 and 2050. The potential of individual mitigation strategies shows great regional variation. Reaching zero emissions will require simultaneous deployment of multiple strategies and greater reduction of embodied emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing enzymes for plastic upcycling using machine learning design and high throughput experiments

Plastic use is ubiquitous in the modern world, and polyethylene terephthalate (PET) is one of the most abundantly produced plastics (and the most highly produced polyester), with ~65 million metric tons manufactured annually. To the consumer, PET is likely most recognizable as the plastic used to make beverage bottles. Like many plastics, traditional mechanical or chemical means of PET deconstruction and upcycling are costly and inefficient. Because of these challenges, recycled plastic is generally of lower quality and is more expensive to produce than virgin plastic derived from petroleum. Ultimately, this results in most plastic ending up as waste. We view plastic waste as an underutilized resource which, with the development of more efficient and high-quality recycling processes, could (1) generate significant economic value while (2) decreasing petroleum usage and greenhouse gas emissions, as well as (3) minimizing its negative environmental and health impacts. Biocatalytic recycling, or biomanufacturing the basic building blocks of new plastic from plastic waste, is a promising approach to plastic reuse that complements existing recycling technologies. Recently, biological enzymes capable of breaking down PET have garnered significant attention as an attractive means of dealing with the plastic problem. These enzymes are currently undergoing pilot studies for implementation in industrial-scale enzyme-based recycling. However, there are significant limitations to current enzymes, including the need to perform costly pre-processing of the plastic waste before the enzymes are able to work. Further optimization of these enzymes is necessary to make these technologies competitive, and ultimately incentivise industry-wide adoption of this biology-based green recycling technology. n this work we demonstrate a means to design and generate performant biological enzymes, capable of efficiently deconstructing plastic waste. Specifically, we applied recent advances in artificial intelligence, machine learning, and statistical analysis to design new versions and discover natural enzymes capable of breaking down PET. We focused on optimizing key properties that are important for industrial-scale enzymatic recycling such as pH and thermotolerance. Normal testing of enzymatic plastic-deconstruction is extremely labor intensive and so through this work we also developed a robotic-assisted experimental pipeline capable of characterizing thousands of candidate enzymes. The results of this iterative, AI-guided, multi-discipline approach have led to increases in enzymatic breakdown of over 150X over starting enzymes. This work supports the rapidly developing and transformative field of biocatalytic solutions to environmental problems beyond the discovery and predictive understanding of enzymes for polymer recycling, and has wide implications for tackling numerous energy problems such as carbon capture and fixation (e.g., engineering carbon monoxide dehydrogenase and the rubisco-pathway), biomining (e.g., design of lanthanide-binding proteins) and biomanufacturing (e.g., lignin-deconstruction enzymes).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermally anisotropic building envelope for thermal management: finite element model calibration using field evaluation data

The thermally anisotropic building envelope (TABE) is an active building envelope that redistributes thermal loads in response to weather conditions and building energy demand. Conductive layers throughout the TABE distribute low-grade heat among hydronic loops, altering heat flow direction and intensity. Finite element models of TABE roof and wall panels were developed and calibrated using field evaluation data. The calibration results showed that heat flux differences between the experimental data and finite element models averaged –0.42% and 3.57%, with a maximum mean square error of 1.78 and 3.96 for roof and wall panels, respectively. A reduction in heat flux from the environment to the building living space over the entire testing period (weeks in July/August) was found to be 85% for roof panels and 335% (load reversed) for wall panels. Finally, these results indicate TABE can effectively harness low-grade thermal energy sources to achieve high energy efficiency and promote demand-side management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating irrigation water use from remotely sensed evapotranspiration data: Accuracy and uncertainties at field, water right, and regional scales

Irrigated agriculture is the dominant user of water globally, but most water withdrawals are not monitored or reported. As a result, it is largely unknown when, where, and how much water is used for irrigation. Here, we evaluated the ability of remotely sensed evapotranspiration (ET) data, integrated with other datasets, to calculate irrigation water withdrawals and applications in an intensively irrigated portion of the United States. We compared irrigation calculations based on an ensemble of satellite-driven ET models from OpenET with reported groundwater withdrawals from hundreds of farmer irrigation application records and a statewide flowmeter database at three spatial scales (field, water right group, and management area). At the field scale, we found that ET-based calculations of irrigation agreed best with reported irrigation when the OpenET ensemble mean was aggregated to the growing season timescale (bias = 1.6–4.9%, R 2 = 0.53–0.74), and agreement between calculated and reported irrigation was better for multi-year averages than for individual years. At the water right group scale, linking pumping wells to specific irrigated fields was the primary source of uncertainty. At the management area scale, calculated irrigation exhibited similar temporal patterns as flowmeter data but tended to be positively biased with more interannual variability. Disagreement between calculated and reported irrigation was strongly correlated with annual precipitation, and calculated and reported irrigation agreed more closely after statistically adjusting for annual precipitation. The selection of an ET model was also an important consideration, as variability across ET models was larger than the potential impacts of conservation measures employed in the region. From these results, we suggest key practices for working with ET-based irrigation data that include accurately accounting for changes in soil moisture, deep percolation, and runoff; careful verification of irrigated area and well-field linkages; and conducting application-specific evaluations of uncertainty.

59 BASIC BIOLOGICAL SCIENCES↗

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel regulator of the fungal phosphate starvation response revealed by transcriptional profiling and DNA affinity purification sequencing

Cells must accurately sense and respond to nutrients to compete for resources and establish growth. Phosphate is a critical nutrient source necessary for signaling, energy metabolism, and synthesis of nucleic acids, phospholipids, and cellular metabolites. During phosphate limitation, fungi import phosphate from the environment and liberate phosphate from phosphate-containing molecules in the cell. In the model filamentous fungus Neurospora crassa, the phosphate starvation response is regulated by the conserved transcription factor NUC-1. The activity of NUC-1 is repressed by a complex of the cyclin-dependent kinase MDK-1 and the cyclin PREG when phosphate is plentiful. When phosphate is limiting, NUC-1 repression by MDK-1/PREG is relieved by the cyclin-dependent kinase inhibitor NUC-2. We investigated the global response of N. crassa to phosphate starvation. During phosphate starvation, NUC-1 directly activated the expression of genes encoding phosphatases, nucleases, and a phosphate transporter and directly repressed genes associated with the ribosome. Additionally, NUC-1 indirectly activated the expression of an uncharacterized transcription factor, which we named nuc-3. NUC-3 directly repressed the expression of genes involved in phosphate acquisition and liberation after an extended period of phosphate starvation. Additionally, NUC-3 directly repressed the expression of the cyclin-dependent kinase inhibitor nuc-2. Thus, through the combination of NUC-3 direct repression of genes in the phosphate starvation response and nuc-2, an activator of the phosphate starvation response, NUC-3 serves to act as a brake on the phosphate starvation response after an extended period of phosphate starvation. This braking mechanism could reduce transcription, a phosphate-intensive process, under conditions of extended phosphate limitation.IMPORTANCEFungi have evolved regulatory networks to respond to available nutrients. Phosphate is often a limiting nutrient for fungi that is critical for many cellular functions, including nucleic acid and phospholipid biosynthesis, cell signaling, and energy metabolism. The fungal response to phosphate limitation is important in interactions with plants and animals. We investigated the global transcriptional response to phosphate starvation and the role of a major transcriptional regulator, NUC-1, in the model filamentous fungus Neurospora crassa. Our data show that NUC-1 is a bifunctional transcription factor that directly activates phosphate acquisition genes, while directly repressing genes associated with phosphate-intensive processes. NUC-1 indirectly regulates an uncharacterized transcription factor, which we named nuc-3. NUC-3 directly represses phosphate acquisition genes and nuc-2, an activator of the phosphate starvation response, during extended periods of phosphate starvation. Thus, NUC-3 acts as a brake on the phosphate starvation response to reduce phosphate-intensive activities, like transcriptional activation, when phosphate starvation persists.

DNA affinity purification sequencing↗

Substitution or Shared Utilization? Intrahousehold Vehicle Use in Mixed-Powertrain Households

While previous research has focused heavily on understanding the factors deriving alternative fuel vehicle adoption rates, there remains a significant gap in understanding how households distribute mileage across different powertrains. This study utilizes data from the 2022 Next Generation National Household Travel Survey to investigate vehicle miles traveled within a sample of 150 plug-in electric vehicle (PEV)-owning households (in which at least one battery electric vehicle is present), characterizing how different powertrains are integrated into daily mobility. Leveraging a Seemingly Unrelated Regression (SUR) framework the study jointly models the utilization of PEVs, hybrid electric vehicles (HEV), and internal combustion engine vehicles (ICEVs) while accounting for household-level substitution effects. The results provide evidence of an asymmetric substitution effect. In households with mixed-powertrain configurations, the ICEV captures a substantially higher share of household miles (compared with the PEV), acting as a utility sponge. Conversely, the model identifies specific socioeconomic and geographic cohorts that prioritize PEV as the primary household workhorse, indicating a systematic sorting effect. Although the sample size limits broader generalizability, these findings suggest that PEVs are used for frequent, specific routine-intensive roles, whereas the ICEV remains a specialized utility vehicle. These insights highlight distinct intrahousehold vehicle use behaviors that are often obscured by aggregate fleetwide statistics.

25 ENERGY STORAGE↗

Operating Hardware Impact on the Heat Transfer Properties of Windows

Despite significant advancements in fenestration technology in the last two decades, the thermal transmittance of fenestration products is still significantly higher than that of walls. This corresponds to 60% of the total energy loss of a modern building envelope through the windows. Hence, further development and improvements of fenestration products are necessary. Increasingly stringent codes and standards for fenestration stimulate industry to work on improved solutions. Thus, it is crucial that assessment techniques are able to account for innovations accurately. The thermal effects of non-continuous hardware in window frames are currently ignored by international rating procedures. A preliminary investigation conducted by our team showed significant performance degradation in two of the three out-opening casement profiles caused by the presence of operating hardware. Frames with the structure made of vinyl and fiberglass consist of many air cavities that are penetrated by operating hardware made of highly conductive materials. In these frames, in order to have an accurate assessment, it may be required to employ three-dimensional modeling due to the convective nature of heat transfer within the cavities. However, in this study, we demonstrate that the three-dimensional (3D) effects of non-continuous hardware can be approximated accurately with simpler two-dimensional (2D) simulations. We then develop a simplified model based on weighted average capable of replacing the time- and computation-intensive 3D simulations with 2D simulations and validate it against market available frames and their corresponding hardware. Validation results show that our approximation technique results in discrepancies lower than 0.05 W/(m2K), or 3% of the total thermal transmittance. Thus, we conclude that simplified 2D simulation models may be used for predicting hardware impact in window frames with reasonable accuracy. As windows and glazing structures are becoming ever better thermally insulated, it is becoming even more important to be able to model the impact of the operating hardware on the total thermal performance in order to design the best windows possible and not let the operating hardware ruin an otherwise well-proven design, which is hence addressed in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Analytic Formula for Entraining CAPE in Midlatitude Storm Environments

Abstract This article introduces an analytic formula for entraining convective available potential energy (ECAPE) with an entrainment rate that is determined directly from an environmental sounding, rather than prescribed by the formula user. Entrainment is connected to the background environment using an eddy diffusivity approximation for lateral mixing, updraft geometry assumptions, and mass continuity. These approximations result in a direct correspondence between the storm-relative flow and the updraft radius and an inverse scaling between the updraft radius squared and entrainment rate. The aforementioned concepts, combined with the assumption of adiabatic conservation of moist static energy, yield an explicit analytic equation for ECAPE that depends entirely on state variables in an atmospheric profile and a few constant parameters with values that are established in past literature. Using a simplified Bernoulli-like equation, the ECAPE formula is modified to account for updraft enhancement via kinetic energy extracted from the cloud’s background environment. CAPE and ECAPE can be viewed as predictors of the maximum vertical velocity w max in an updraft. Hence, these formulas are evaluated using w max from past numerical modeling studies. Both of the new formulas improve predictions of w max substantially over commonly used diagnostic parameters, including undiluted CAPE and ECAPE with a constant prescribed entrainment rate. The formula that incorporates environmental kinetic energy contribution to the updraft correctly predicts instances of exceedance of by w max , and provides a conceptual explanation for why such exceedance is rare among past simulations. These formulas are potentially useful in nowcasting and forecasting thunderstorms and as thunderstorm proxies in climate change studies. Significance Statement Substantial mixing occurs between the upward-moving air currents in thunderstorms (updrafts) and the surrounding comparatively dry environmental air, through a process called entrainment. Entrainment controls thunderstorm intensity via its diluting effect on the buoyancy of air within updrafts. A challenge to representing entrainment in forecasting and predictions of the intensity of updrafts in future climates is to determine how much entrainment will occur in a given thunderstorm environment without a computationally expensive high-resolution simulation. To address this gap, this article derives a new formula that computes entrainment from the properties of a single environmental profile. This formula is shown to predict updraft vertical velocity more accurately than past diagnostics, and can be used in forecasting and climate prediction to improve predictions of thunderstorm behavior and impacts.

54 ENVIRONMENTAL SCIENCES↗

Systems Packages for Washington State Building Performance Standard Incentive Program: Phase 1 Analysis

Starting in 2026 Washington State building performance standards will come into effect that require commercial buildings larger than 50,000 sf to meet site energy use intensity targets. To support a state incentive program designed to encourage building owners to start complying early, we characterized the building stock energy use of 11 building types, analyzed 43 energy upgrade measures, and developed seven packages of energy upgrade measures using the ComStock energy analysis tool. Each energy upgrade package included from 4 to 17 energy measures consisting of lighting, HVAC, and envelope upgrades. Package savings were calculated for four priority building types using a sample of 35,000 buildings characterized by four building area bins, three climate zones, and two county types (urban and rural). Of the 28 package and building type combinations analyzed, 17 (61%) met or exceeded program energy savings targets and two packages met targets for all four building types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the energy impact potential of energy efficiency measures for retrofit applications: A case study with U.S. medium office buildings

Quantifying the energy savings of various energy efficiency measures (EEMs) for an energy retrofit project often necessitates an energy audit and detailed whole building energy modeling to evaluate the EEMs; however, this is often cost-prohibitive for small and medium buildings. In order to provide a defined guideline for projects with assumed common baseline characteristics, this paper applies a sensitivity analysis method to evaluate the impact of individual EEMs and groups these into packages to produce deep energy savings for a sample prototype medium office building across 15 climate zones in the United States. We start with one baseline model for each climate zone and nine candidate EEMs with a range of efficiency levels for each EEM. Three energy performance indicators (EPIs) are defined, which are annual electricity use intensity, annual natural gas use intensity, and annual energy cost. Then, a Standard Regression Coefficient (SRC) sensitivity analysis method is applied to determine the sensitivity of each EEM with respect to the three EPIs, and the relative sensitivity of all EEMs are calculated to evaluate their energy impacts. For the selected range of efficiency levels, the results indicate that the EEMs with higher energy impacts (i.e., higher sensitivity) in most climate zones are high-performance windows, reduced interior lighting power, and reduced interior plug and process loads. However, the sensitivity of the EEMs also vary by climate zone and EPI; for example, improved opaque envelope insulation and efficiency of cooling and heating systems are found to have a high energy impact in cold and hot climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring the Potential of Factory Installed Solar + Storage for Homebuilding

In recent years, an increasing number of grid disruptions due to intense weather events, natural disasters, and high peak loads resulted in increased interest in energy-resilient homes. Solar + storage (S+S) as an energy resiliency solution can provide continuity, onsite generation, and backup power during critical events. This project explored factory-installed solar plus storage (FISS) to overcome first cost and installation barriers and bring this resiliency solution to scale for single-family affordable and market-rate homebuyers. Guided by the principles of Lean manufacturing, the team explored how factories building high-performance zero energy modular homes can incorporate S+S into their existing construction system while improving quality and productivity and reducing the costs of the resilient energy system.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Staying Competitive in Clean Manufacturing: Insights on Barriers from Industry Interviews

While industrial emissions research has historically focused on energy-intensive sectors like steel, cement, and chemicals, this study addresses a critical gap by examining barriers across all the manufacturing industry in the U.S. Sectors like food processing, retail, plastics, and transportation face unique challenges distinct from heavy industry, operating on thin margins with limited bargaining power while experiencing heightened consumer and stakeholder pressure for improved environmental responsibility. Through structured interview data collection process and using quantitative ratings and qualitative analysis, this research identifies and categorizes emission reduction barriers across four key themes: financial, technical, organizational, and regulatory. Unlike energy-intensive industries that may pursue hydrogen or carbon capture technologies, discrete manufacturing industry like automotive, electrical and electronics, and machine manufacturers typically focus on energy efficiency, electrification of thermal processes, and alternate fuel switching, solutions better aligned with their lower-temperature processes and distributed facility profiles. The study’s primary contribution lies in documenting specific barrier manifestations within organizations and identifying proven mitigation strategies that companies have successfully implemented or observed among peers.

business competitiveness↗