Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compton Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Progress Toward Gamma-Ray Imaging for Automated Holdup Measurement in Gloveboxes

Shielded gloveboxes are currently being constructed to facilitate dilution and disposal of many tons of excess plutonium oxide. Measuring holdup in these gloveboxes is expected to be challenging because of the limited available lines of sight through the glovebox shielding. A system of gamma-ray imagers is being developed to provide localization and quantification for holdup. The system will be mounted above the glovebox, where there is minimal shielding. Multiple imagers with overlapping coded-aperture fields of view are employed to enable three-dimensional reconstruction. Compton reconstruction is also available to localize sources outside the coded-aperture field of view. Improved uncertainties with respect to current techniques are expected by virtue of the fixed installation, spectroscopic performance of the detectors, and iterative image reconstruction techniques. Measurement campaigns have been undertaken at an active glovebox at Savannah River Site to test the gamma-ray imaging system in an operational environment, providing a simple test of a single imager that mimics the geometry of the installation proposed for future shielded gloveboxes. Data taken during quiescent periods in the glovebox were used to measure the buildup of material on an outlet filter and record a trend over time. Calibration data was taken with known sources to simplify analysis and provide a reliable assay of the filter. Resulting images make it possible to isolate the filter from other sources and recognize compromised data. This paper will present details of the measurement and analysis methods.

Schmitt, Kyle↗

Comparison of equilibrium ohmic and nonequilibrium swarm models for monitoring conduction electron evolution in high-altitude EMP calculations

Here, atmospheric electromagnetic pulse (EMP) events are important physical phenomena that occur through both man-made and natural processes. Radiation-induced currents and voltages in EMP can couple with electrical systems, such as those found in satellites, and cause significant damage. Due to the disruptive nature of EMP, it is important to accurately predict EMP evolution and propagation with computational models. CHAP-LA (Compton High Altitude Pulse-Los Alamos) is a state-of-the-art EMP code that solves Maxwell inline images equations for gamma source-induced electromagnetic fields in the atmosphere. In EMP, low-energy, conduction electrons constitute a conduction current that limits the EMP by opposing the Compton current. CHAP-LA calculates the conduction current using an equilibrium ohmic model. The equilibrium model works well at low altitudes, where the electron energy equilibration time is short compared to the rise time or duration of the EMP. At high altitudes, the equilibration time increases beyond the EMP rise time and the predicted equilibrium ionization rate becomes very large. The ohmic model predicts an unphysically large production of conduction electrons which prematurely and abruptly shorts the EMP in the simulation code. An electron swarm model, which implicitly accounts for the time evolution of the conduction electron energy distribution, can be used to overcome the limitations exhibited by the equilibrium ohmic model. We have developed and validated an electron swarm model previously in Pusateri et al. (2015). Here we demonstrate EMP damping behavior caused by the ohmic model at high altitudes and show improvements on high-altitude, upward EMP modeling obtained by integrating a swarm model into CHAP-LA.

54 ENVIRONMENTAL SCIENCES↗

A spectrometer for ultrashort gamma-ray pulses with photon energies greater than 10 MeV

Herein we present a design for a pixelated scintillator based gamma-ray spectrometer for non-linear inverse Compton scattering experiments. By colliding a laser wakefield accelerated electron beam with a tightly focused, intense laser pulse, gamma-ray photons up to 100 MeV energies and with few femtosecond duration may be produced. To measure the energy spectrum and angular distribution, a 33 × 47 array of cesium-iodide crystals was oriented such that the 47 crystal length axis was parallel to the gamma-ray beam and the 33 crystal length axis was oriented in the vertical direction. Using an iterative deconvolution method similar to the YOGI code, modeling of the scintillator response using GEANT4 and fitting to a quantum Monte Carlo calculated photon spectrum, we are able to extract the gamma ray spectra generated by the inverse Compton interaction.

47 OTHER INSTRUMENTATION↗

Performance of an Array of 6 X 6 X 20 mm3 Virtual Frisch-Grid CdZnTe Detectors With A Waveform Sampling Readout System

Arrays of CdZnTe (CZT) bars with high spatial and energy resolution are an enabling technology for future space missions, such as the image plane detector of the Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO). GECCO will explore the medium-energy (100 keV – 10 MeV) gamma-ray sky, which is among the least covered windows to the Universe with a massive potential for discovery. We have integrated an array of 6x6x20 mm3 virtual Frisch-grid (VFG) CZT detectors, measuring signals from the cathodes, anodes, and pads on each of the four sides of each bar. The VFG CZT detector is read out with an IDEAS GDS-100 waveform sampling readout system to optimize the signal processing and event reconstruction. We evaluated the energy and position resolution of the integrated VFG CZT array with a 137Cs source and successfully demonstrated better than 1% energy resolution and finer than 1 mm position resolution at 662 keV. Furthermore, we carried out a beam test at the High Intensity Gamma-ray Source (HIGS) at Duke University to investigate the performance of the system for higher energy gamma-rays. Together with the basic performance obtained from the 137Cs source, we present here those results from the beam test with various gamma-ray energies up to 8 MeV.

Makoto Sasaki↗

Fundamental x-ray interaction limits in diagnostic imaging detectors: Frequency-dependent Swank noise

A frequency-dependent x-ray Swank factor based on the ''x-ray interaction'' modulation transfer function and normalized noise power spectrum is determined from a Monte Carlo analysis. This factor was calculated in four converter materials: amorphous silicon (a-Si), amorphous selenium (a-Se), cesium iodide (CsI), and lead iodide (PbI{sub 2}) for incident photon energies between 10 and 150 keV and various converter thicknesses. When scaled by the quantum efficiency, the x-ray Swank factor describes the best possible detective quantum efficiency (DQE) a detector can have. As such, this x-ray interaction DQE provides a target performance benchmark. It is expressed as a function of (Fourier-based) spatial frequency and takes into consideration signal and noise correlations introduced by reabsorption of Compton scatter and photoelectric characteristic emissions. It is shown that the x-ray Swank factor is largely insensitive to converter thickness for quantum efficiency values greater than 0.5. Thus, while most of the tabulated values correspond to thick converters with a quantum efficiency of 0.99, they are appropriate to use for many detectors in current use. A simple expression for the x-ray interaction DQE of digital detectors (including noise aliasing) is derived in terms of the quantum efficiency, x-ray Swank factor, detector element size, and fill factor. Good agreement is shown with DQE curves published by other investigators for each converter material, and the conditions required to achieve this ideal performance are discussed. For high-resolution imaging applications, the x-ray Swank factor indicates: (i) a-Si should only be used at low-energy (e.g., mammography); (ii) a-Se has the most promise for any application below 100 keV; and (iii) while quantum efficiency may be increased at energies just above the K edge in CsI and PbI{sub 2}, this benefit is offset by a substantial drop in the x-ray Swank factor, particularly at high spatial frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a 2 MeV Compton scattering gamma-ray source for DNDO missions

Nuclear resonance fluorescence-based isotope-specific detection and imaging is a powerful new technology that can enable access to new mission spaces for DNDO. Within this context, the development of advanced mono-energetic gamma ray sources plays an important role in the DNDO R&D portfolio, as it offers a faster, more precise, and safer alternative to conventional Bremsstrahlung sources. In this report, a specific design strategy is presented, along with a series of theoretical and computational tools, with the goal of optimizing source parameters for DNDO applications. In parallel, key technologies are outlined, along with discussions justifying specific choices and contrasting those with other alternatives. Finally, a complete conceptual design is described, and machine parameters are presented in detail.

42 ENGINEERING↗

Free-electron laser inverse-Compton interaction x-ray source

Free-electron lasers (FEL) and synchrotron sources of high brilliance x-rays have been confirmed to be of tremendous value in basic and applied research. Inverse-Compton sources (ICS) can achieve brilliance matching the requirements of many applications pioneered at those FEL and synchrotron facilities—including phase contrast imaging, macromolecular x-ray crystallography, and x-ray microscopy—but with size, cost, and complexity compatible with a small laboratory. The free-electron laser inverse-Compton interaction compact x-ray source at the University of Hawaii at Manoa is a unique approach to an ICS which employs an FEL as the laser source. We have measured a total average flux of 3.0 × 10 5 photons / second with an average brilliance of 2.0 × 10 7 photons / s mm 2 mrad 2 0.1% of bandwidth (BW) with a peak energy of 10.9 keV from the source. While these results are modest in comparison to the standards set by other IC sources, upgrades to the system have the potential to increase the total average flux to 9.2 × 10 11 photons / second with an average brilliance of 1.9 × 10 12 photons / s mm 2 mrad 2 0.1% BW: comparing more favorably to other sources. We discuss the scientific program, the progress made in design and development, and the achievements of the source to date. We also outline future upgrades and integration needed to yield an enabling source for emerging high brilliance x-ray applications.

43 PARTICLE ACCELERATORS↗

Visualizing redox orbitals and their potentials in advanced lithium-ion battery materials using high-resolution x-ray Compton scattering

Reduction-oxidation (redox) reactions are the key processes that underlie the batteries powering smartphones, laptops, and electric cars. A redox process involves transfer of electrons between two species. For example, in a lithium-ion battery, current is generated when conduction electrons from the lithium anode are transferred to the redox orbitals of the cathode material. The ability to visualize or image the redox orbitals and how these orbitals evolve under lithiation and delithiation processes is thus of great fundamental and practical interest for understanding the workings of battery materials. In this study, we show that inelastic scattering spectroscopy using high-energy x-ray photons (Compton scattering) can yield faithful momentum space images of the redox orbitals by considering lithium iron phosphate (LiFePO 4 or LFP) as an exemplar cathode battery material. Our analysis reveals a new link between voltage and the localization of transition metal 3d orbitals and provides insight into the puzzling mechanism of potential shift and how it is connected to the modification of the bond between the transition metal and oxygen atoms. Our study thus opens a novel spectroscopic pathway for improving the performance of battery materials.

25 ENERGY STORAGE↗

CANGAROO-III SEARCH FOR TeV GAMMA RAYS FROM TWO CLUSTERS OF GALAXIES

Because accretion and merger shocks in clusters of galaxies may accelerate particles to high energies, clusters are candidate sites for the origin of ultra-high-energy (UHE) cosmic rays. A prediction was presented for gamma-ray emission from a cluster of galaxies at a detectable level with the current generation of imaging atmospheric Cherenkov telescopes. The gamma-ray emission was produced via inverse Compton upscattering of cosmic microwave background photons by electron-positron pairs generated by collisions of UHE cosmic rays in the cluster. We observed two clusters of galaxies, Abell 3667 and Abell 4038, searching for very high energy gamma-ray emission with the CANGAROO-III atmospheric Cherenkov telescope system in 2006. The analysis showed no significant excess around these clusters, yielding upper limits on the gamma-ray emission. From a comparison of the upper limit for the northwest radio relic region of Abell 3667 with a model prediction, we derive a lower limit for the magnetic field of the region of approx0.1 muG. This shows the potential of gamma-ray observations in studies of the cluster environment. We also discuss the flux upper limit from cluster center regions using a model of gamma-ray emission from neutral pions produced in hadronic collisions of cosmic-ray protons with the intracluster medium. The derived upper limit of the cosmic-ray energy density within this framework is an order of magnitude higher than that of our Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

COMPTEL observations of the 1.809 MeV gamma-ray line from galactic Al-26

The COMPTEL experiment on the Compton Gamma-Ray Observatory (CGRO) has been demonstrated to be capable of imaging the Galaxy within its field of view of about 1 steradian in the 1.809 MeV gamma-ray line originating from radioactive Al-26. The combined data from the CGRO sky survey in 1991/1992 have been analyzed to provide a first map of the inner Galaxy in this gamma-ray line. The 1.809 MeV emission appears extended along the inner 70 deg of the Galactic plane, with a relatively sharp falloff outside this regime. Correlations with massive stars and supernova remnants as possible tracers of the candidate Al-26 sources are discussed.

Diehl, R.↗

Performance of the Three-Dimensional Track Imager (3-DTI) for Gamma-Ray Telescopes

We have been developing a gas time projection chamber for the imaging of gamma-rays between 0.3 - 50 MeV, the Three-Dimensional Track Imager (3DTI). The detector is being designed for use on satellite experiments for the imaging of astrophysical gamma-ray sources. Electrons produced by pair production or Compton scattering ionize the gas and these ionization electrons are detected by the cross-strip micro-well detector at the bottom of the chamber. Discrete component of front end electronics and time digitization electronics have been developed. We will present results of prototype microwell detector and laboratory set-up in various gas mixtures.

Son, Seunghee↗

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

Precision X-Band Linac Technologies for Nuclear Photonics Gamma-Ray Sources

Nuclear photonics is an emerging field of research requiring new tools, including high spectral brightness, tunable gamma-ray sources; high photon energy, ultrahigh-resolution crystal spectrometers; and novel detectors. This presentation focuses on the precision linac technology required for Compton scattering gamma-ray light sources, and on the optimization of the laser and electron beam pulse format to achieve unprecedented spectral brightness. Within this context, high-gradient X-band technology will be shown to offer optimal performance in a compact package, when used in conjunction with the appropriate pulse format, and photocathode illumination and interaction laser technologies. The nascent field of nuclear photonics is enabled by the recent maturation of new technologies, including high-gradient X-band electron acceleration, robust fiber laser systems, and hyper-dispersion CPA. Recent work has been performed at LLNL to demonstrate isotope-specific detection of shielded materials via NRF using a tunable, quasi-monochromatic Compton scattering gamma-ray source operating between 0.2 MeV and 0.9 MeV photon energy. This technique is called Fluorescence Imaging in the Nuclear Domain with Energetic Radiation (or FINDER). This work has, among other things, demonstrated the detection of {sup 7}Li shielded by Pb, utilizing gamma rays generated by a linac-driven, laser-based Compton scattering gamma-ray source developed at LLNL. Within this context, a new facility is currently under construction at LLNL, with the goal of generating tunable {gamma}-rays in the 0.5-2.5 MeV photon energy range, at a repetition rate of 120 Hz, and with a peak brightness in the 10{sup 20} photons/(s x mm{sup 2} x mrad{sup 2} x 0.1% bw).

42 ENGINEERING↗

VLBI Observations of Southern EGRET Identifications: PKS 0208-512, PKS 0521-365 and PKS 0537-441 - 1

We present high-resolution very long baseline interferometry images of three southern radio sources that the Energetic Gamma-Ray Experiment Telescope (EGRET), on board the Compton Gamma Ray Observatory, has identified as greater than 100 MeV gamma-ray sources. These are the first results in a continuing program of VLBI observations of southern EGRET identifications. For two of these sources, PKS 0208-512 (at 4.851 GHz) and PKS 0537-441 (at 4.851 and 8.418 GHz), the images represent first-epoch observations. For the remaining lower redshift object, PKS 0521-365, we present images from three epochs at 4.851 GHz and an image from one further epoch at 8.418 GHz, spanning approximately 1 yr. We discuss the need for further extensive VLBI observations of EGRET-identified radio sources.

Tingay, S. J.↗

Integrated NDVI images for Niger 1986-1987

Two NOAA AVHRR images are presented which provide a comparison of the geographic distribution of an integration of the normalized difference vegetation index (NDVI) for the Sahel zone in Niger for the growing seasons of 1986 and 1987. The production of the images and the application of the images for resource management are discussed. Daily large area coverage with a spatial resolution of 1.1 km at nadir were transformed to the NDVI and geographically registered to produce the images.

Harrington, John A., Jr.↗

DISCOVERY OF A KILOPARSEC-SCALE X-RAY/RADIO JET IN THE z = 4.72 QUASAR GB 1428+4217

We report the discovery of a one-sided 3.''6 (24 kpc, projected) long jet in the high-redshift, z = 4.72, quasar GB 1428+4217 in new Chandra X-ray and Very Large Array (VLA) radio observations. This is the highest redshift kiloparsec-scale X-ray/radio jet known. Analysis of archival very long baseline interferometry 2.3 and 8.6 GHz data reveal a faint one-sided jet extending out to {approx}200 pc and aligned to within {approx}30 Degree-Sign of the Chandra/VLA emission. The 3.''6 distant knot is not detected in an archival Hubble Space Telescope image, and its broadband spectral energy distribution is consistent with an origin from inverse Compton scattering of cosmic microwave background photons for the X-rays. Assuming also equipartition between the radiating particles and magnetic field, the implied jet Lorentz factor is Almost-Equal-To 5. This is similar to the other two known z {approx} 4 kpc scale X-ray jet cases and smaller than typically inferred in lower-redshift cases. Although there are still but a few such very high redshift quasar X-ray jets known, for an inverse Compton origin, the present data suggest that they are less relativistic on large scales than their lower-redshift counterparts.

79 ASTRONOMY AND ASTROPHYSICS↗

Quasiclassical Computations of Compton-Scattered Spectra

Quality X-ray sources are crucial to fundamental physics research, medical radiology, humanities research, and materials science. While synchrotron radiation (SR) facilities produce the state-of-the-art emissions with respect to brilliance and frequency tunability, the great expense required to build, maintain, and operate these structures greatly limits their accessibility to researchers. Much of the research conducted at SR facilities, however, may be conducted with inverse Compton sources (ICS). Accelerator-based Compton scattering light sources generate high-energy, high-brilliance emissions. Compton scattering is the process by which a photon scatters o? an electron. ICS offer an affordable, in-lab alternative to SR facilities. Even though SR facilities produce greater intensity emissions, Compton sources provide the same frequency tunability at the intensities suitable for the purposes of many researchers currently fighting for time at SR facilities, i.e., ICS provides intensities suitable for contrast imaging, X-ray fluorescence, X-ray-diffraction, and X-ray spectroscopy. The focus of this work is to create computational models to simulate Compton-scattered spectra. These models have been used to build a theoretical basis for methods of improving the quality of future Compton sources and to preform diagnostic analysis of existing light sources. The theoretical basis of each model is derived from first principles. The numerical methods employed by each model are defined. A full description of the various functionalities of each code will be addressed. Furthermore, an in-depth analysis of spectral bandwidth sources is discussed. The complex physics arising from an extremely high-intensity, nonlinear laser pulse is explored in detail. Methods of frequency modulation of the incident laser, i.e., a method for correcting the nonlinear broadening effects on the scattered spectrum, will also be discussed. The work will conclude with a an exploration of the ongoing research efforts regarding regimes of operation outside of the limits of these current models.

Johnson, Erik↗