Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Parabolic single-crystal diamond lenses for coherent x-ray imaging

We demonstrate parabolic single-crystal diamond compound refractive lenses designed for coherent x-ray imaging resilient to extreme thermal and radiation loading expected from next generation light sources. To ensure the preservation of coherence and resilience, the lenses are manufactured from the highest-quality single-crystalline synthetic diamond material grown by a high-pressure high-temperature technique. Picosecond laser milling is applied to machine lenses to parabolic with a similar or equal to 1 mu m precision and surface roughness. A compound refractive lens comprised of six lenses with a radius of curvature R = 200 mu m at the vertex of the parabola and a geometrical aperture A = 900 mu m focuses 10 keV x-ray photons from an undulator source at the Advanced Photon Source facility to a focal spot size of similar or equal to 20 x 90 mu m(2) with a gain factor of similar or equal to 50 - 100. (C) 2015 Author(s).

Terentyev, Sergey↗

Fast digital lossy compression for X-ray ptychographic data

Increases in X-ray brightness from synchrotron light sources lead to a requirement for higher frame rates from hybrid pixel array detectors (HPADs), while also favoring charge integration over photon counting. However, transfer of the full uncompressed data will begin to constrain detector design, as well as limit the achievable continuous frame rate. Here a data compression scheme that is easy to implement in a HPAD's application-specific integrated circuit (ASIC) is described, and how different degrees of compression affect image quality in ptychography, a commonly employed coherent imaging method, is examined. Using adaptive encoding quantization, it is shown in simulations that one can digitize signals up to 16383 photons per pixel (corresponding to 14 bits of information) using only 8 or 9 bits for data transfer, with negligible effect on the reconstructed image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three-dimensional hard X-ray ptychographic reflectometry imaging on extended mesoscopic surface structures

Many nanodevices and quantum devices, with their sizes often spanning from millimeters down to sub-nanometer, have intricate low-dimensional, non-uniform, or hierarchical structures on surfaces and interfaces. Since their functionalities are dependent on these structures, high-resolution surface-sensitive characterization becomes imperative to gain a comprehensive understanding of the function–structure relationship. We thus developed hard x-ray ptychographic reflectometry imaging, a new technique that merges the high-resolution two-dimensional imaging capabilities of hard x-ray ptychography for extended objects, with the high-resolution depth profiling capabilities of x-ray reflectivity for layered structures. The synergy of these two methods fully leverages both amplitude and phase information from ptychography reconstruction to not only reveal surface topography and localized structures, such as shapes and electron densities, but also yields statistical details, such as interfacial roughness that is not readily accessible through coherent imaging solely. The hard x-ray ptychographic reflectometry imaging is well-suited for three-dimensional imaging of mesoscopic samples, particularly those comprising planar or layered nanostructures on opaque supports, and could also offer a high-resolution surface metrology and defect analysis on semiconductor devices, such as integrated nanocircuits and lithographic photomasks for microchip fabrications.

47 OTHER INSTRUMENTATION↗

SAR image effects on coherence and coherence estimation.

Radar coherence is an important concept for imaging radar systems such as synthetic aperture radar (SAR). This document quantifies some of the effects in SAR which modify the coherence. Although these effects can disrupt the coherence within a single SAR image, this report will focus on the coherence between separate images, such as for coherent change detection (CCD) processing. There have been other presentations on aspects of this material in the past. The intent of this report is to bring various issues that affect the coherence together in a single report to support radar engineers in making decisions about these matters.

Bickel, Douglas Lloyd↗

Calibrated helium and carbon ion flow measurements in the DIII-D divertor plasma

To explore the influence of drifts on ion flows in the DIII-D divertor and Scrape-Off-Layer (SOL), a calibrated Coherence Imaging System (CIS) views the lower divertor. A new tuneable calibration laser and precision wavemeter provide the rest wavelength for CIII 465 nm plasma emissions resulting in ≤ 1 km/s uncertainty in ion velocities that are in the range of 30 km/s in the divertor plasma. The 2-D line-integrated velocity images have been tomographically inverted to obtain maps of ion velocity. Both He + and C 2+ ion velocity maps were measured in both directions of the toroidal magnetic field B T , and C 2+ images were obtained in attached and detached L- and H-mode plasmas. The measured C 2+ velocities are in the range of 20-30km/s and are compared with UEDGE modeling with full drifts. While He II as a main ion is expected to be entrained in the plasma flow, the C 2+ impurity flow involves the competition between the frictional and ion temperature gradient forces. Both the CIS data and UEDGE modeling agree that the C 2+ flow is towards the divertor plates, but flips with the direction of B T . In general, the experimental C 2+ emission and flow profiles have a wider spatial extent than the UEDGE modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of drifts on scrape-off layer transport in W7-X

Abstract Drifts affect particle, momentum, and energy transport in the scrape-off layer (SOL) of tokamaks and stellarators, altering plasma flows and creating asymmetries between divertors. To understand how drifts affect SOL transport in the W7-X island divertor, an experiment was performed to compare plasmas with matched core parameters but opposite magnetic field directions, and therefore opposite drift transport directions. Parallel flow measurements made with coherence imaging spectroscopy are interpreted with the aid of a diagnostic forward model and a 1D simple SOL model that includes the E × B drift. In low-density plasmas ( n ‾ e < 2 × 10 19 m −3 ), the poloidal E × B drift induces a large poloidal density asymmetry within the island SOL, as measured by divertor Langmuir probes. This in turn causes the parallel flow stagnation point to shift from the position halfway between targets to the X-point in the drift direction, leading to near-unidirectional flow throughout the SOL. As density increases, the effects of the poloidal E × B drift decrease substantially, resulting in a smaller density asymmetry and the development of a counter-streaming flow pattern. For the entire density range probed in this experiment ( n ‾ e = 1.5 − 6 × 10 19 m −3 ), the experimental observations are more consistent with the effects of the poloidal E × B drift than the radial E × B drift.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.

60 APPLIED LIFE SCIENCES↗

2D measurements of parallel counter-streaming flows in the W7-X scrape-off layer for attached and detached plasmas

Abstract Investigations of particle parallel flow velocities have been carried out for the scrape-off layer (SOL) of the Wendelstein 7-X (W7-X) stellarator, in order to gain insights on the SOL transport properties during attached and detached plasma scenarios. The experimental evidence is based on the coherence imaging spectroscopy (CIS) diagnostic, able to measure 2D impurity emission intensity and flow velocity. The impurity monitored by CIS is C 2+ , characterized by a line-emission intensity observed to be linearly proportional to the total plasma radiated power in both attached and detached plasmas. The related C 2+ velocity shows a strong dependence on the line-averaged electron density while remaining insensitive to the input power. During attached plasmas, the velocity increases with increasing line-averaged density. The tendency reverses in the transition to and during detachment, in which the velocity decreases by at least a factor of 2. The sharp drop in velocity, together with a rise in line-emission intensity, is reliably correlated to the detachment transition and can therefore be used as one of its signatures. The impurity flow velocity appears to be well coupled with the main ions’ one, thus implying the dominant role of impurity-main ion friction in the parallelimpurity transport dynamics. In view of this SOL impurity transport regime, the CIS measurement results are here interpreted with the help of EMC3-Eirene simulations, and their major trends are already explainable with a simple 1D fluid model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EUV photolithography mask inspection using Fourier ptychography

Fourier ptychography is a computational imaging techniques that combines various full-field coherent images acquired under varied illumination angles and combined to yield a angular spectrum with a large synthetic numerical aperture and non-interferometric phase information. We present here the implementation of this technique in a full-field soft x-ray microscope designed to emulate modern EUV lithography tools imaging conditions, and we show that this technique can be used for the study of EUV photomasks. The technique allows us to quantitatively characterize phase defects (predominant in EUV lithography), to study new mask designs made of phase structures, to study sub-resolution assist features and extend the resolution of the microscope down to 26-nm, correspond to the N1 technology node.

Wojdyla, Antoine↗

Final report: high resolution lensless 3D imaging of nanostructures with coherent x-rays

This project helped pioneer the core capabilities of coherent diffraction imaging (CDI) using X rays at synchrotron light source facilities. We developed an apparatus that was used for CDI at the Advanced Light Source, and applied it to 2D and 3D imaging of nanostructures. We also explored a number of conceptual and computational issues on the reconstruction of CDI data.

36 MATERIALS SCIENCE↗

Submillimeter Confocal Imaging Active Module

The term submillimeter confocal imaging active module (SCIAM) denotes a proposed airborne coherent imaging radar system that would be suitable for use in reconnaissance, surveillance, and navigation. The development of the SCIAM would include utilization and extension of recent achievements in monolithic microwave integrated circuits capable of operating at frequencies up to and beyond a nominal radio frequency of 340 GHz. Because the SCIAM would be primarily down-looking (in contradistinction to primarily side-looking), it could be useful for imaging shorter objects located between taller ones (for example, objects on streets between buildings). The SCIAM would utilize a confocal geometry to obtain high cross-track resolution, and would be amenable to synthetic-aperture processing of its output to obtain high along-track resolution. The SCIAM (see figure) would include multiple (two in the initial version) antenna apertures, separated from each other by a cross-track baseline of suitable length (e.g., 1.6 m). These apertures would both transmit the illuminating radar pulses and receive the returns. A common reference oscillator would generate a signal at a controllable frequency of (340 GHz + (Delta)f)/N, where (Delta)f is an instantaneous swept frequency difference and N is an integer. The output of this oscillator would be fed to a frequency- multiplier-and-power-amplifier module to obtain a signal, at 340 GHz + (Delta)f, that would serve as both the carrier signal for generating the transmitted pulses and a local-oscillator (LO) signal for a receiver associated with each antenna aperture. Because duplexers in the form of circulators or transmit/receive (T/R) switches would be lossy and extremely difficult to implement, the antenna apertures would be designed according to a spatial-diplexing scheme, in which signals would be coupled in and out via separate, adjacent transmitting and receiving feed horns. This scheme would cause the transmitted and received beams to be aimed in slightly different directions, and, hence, to not overlap fully on the targets on the ground. However, a preliminary analysis has shown that the loss of overlap would be small enough that the resulting loss in signal-to-noise ratio (SNR) would be much less than the SNR loss associated with the use of a 340-GHz T/R switch.

Hong, John↗

Real-Time Holographic Image Correction Using Bacteriorhodopsin

We present experimental results of one-way coherent imaging through a thin phase-aberrating medium using a holographic technique with bacteriorhodopsin as a real-time holographic material. Bacteriorhodopsin is well suited for the application when the aberration is time varying because of its real-time writing and erasing characteristics, sensitivity, and spatial resolution. We show results with final image resolution of greater than 20 line pairs/mm and high signal-to-noise ratio using a polarization-holography approach.

Downie, John D.↗

Single-shot hyperspectral coherent Raman planar imaging in the range 0–4200 cm⁻¹

We propose a technique for ultrabroadband planar coherent Raman spectroscopy that enables wideband chemically selective mapping of molecular partition functions in the gas-phase within a single-laser-shot. A spectral region spanning 0–4200 cm⁻¹ is excited simultaneously, in principle allowing for coherent planar imaging of most all fundamental Raman-active modes. This unique instantaneous and spatially correlated assessment enables multiplexed studies of transient dynamical systems in a two-dimensional (2D) field. Here, we demonstrate single-laser-shot high temperature diagnostics of H₂, with spatially resolved 2D measurement of transitions of both the pure-rotational H₂ S-branch and the vibrational H₂ Q-branch, analyzing the temperature contour of a reacting fuel-species as it evolves at a flame-front.

08 HYDROGEN↗

Far-field speckle correlations as a function of object position for microscopically distinguishing objects hidden in a randomly scattering medium

Super-resolution optical sensing is of critical importance in science and technology and has required prior information about an imaging system or obtrusive near-field probing. Additionally, coherent imaging and sensing in heavily scattering media such as biological tissue has been challenging, and practical approaches have either been restricted to measuring the field transmission of a single point source, or to where the medium is thin. We present the concept of far-subwavelength spatial sensing with relative object motion in speckle as a means to coherently sense through heavy scatter. Experimental results demonstrate the ability to distinguish nominally identical objects with nanometer-scale translation while hidden in randomly scattering media, without the need for precise or known location and with imprecise replacement. The theory and supportive illustrations presented provide the basis for super-resolution sensing and the possibility of virtually unlimited spatial resolution, including through thick, heavily scattering media with relative motion of an object in a structured field. This work provides enabling opportunities for material inspection, security, and biological sensing.

Hastings, Ryan L. (ORCID:0009000095977807)↗

Diffractive Imaging Using Partially Coherent X Rays

The measured spatial coherence characteristics of the illumination used in a diffractive imaging experiment are incorporated in an algorithm that reconstructs the complex transmission function of an object from experimental x-ray diffraction data using 1.4 keV x rays. Conventional coherent diffractive imaging, which assumes full spatial coherence, is a limiting case of our approach. Even in cases in which the deviation from full spatial coherence is small, we demonstrate a significant improvement in the quality of wave field reconstructions. Our formulation is applicable to x-ray and electron diffraction imaging techniques provided that the spatial coherence properties of the illumination are known or can be measured.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extreme ultraviolet microscope characterization using photomask surface roughness

We demonstrate a method for characterizing the field-dependent aberrations of a full-field synchrotron-based extreme ultraviolet microscope. The statistical uniformity of the inherent, atomic-scale roughness of readily-available photomask blanks enables a self-calibrating computational procedure using images acquired under standard operation. We characterize the aberrations across a 30-um field-of-view, demonstrating a minimum aberration magnitude of smaller than λ/21 rms averaged over the center 5-um area, with a measurement accuracy better than λ/180 rms. The measured field variation of aberrations is consistent with system geometry and agrees with prior characterizations of the same system. In certain cases, it may be possible to additionally recover the illumination wavefront from the same images. Our method is general and is easily applied to coherent imaging systems with steerable illumination without requiring invasive hardware or custom test objects; hence, it provides substantial benefits when characterizing microscopes and high-resolution imaging systems in situ.

47 OTHER INSTRUMENTATION↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

Role of multiple scattering in formation of OCT skin images

Optical coherence tomography (OCT) images of model human skin samples are obtained by using Monte Carlo simulations. The contributions of least and multiple scattering, diffusion and nondiffusion components and of separate scattering orders are studied by using a multilayer skin model based on experimental images. The model images are obtained by neglecting speckles or taking them into account. It is shown that least scattering forms the image of the upper skin layers, while the contribution of multiple scattering can be characterised as a blurred full image with a lower contrast. Repeated scattering mainly contributes to the OCT image at depths up to 1 mm. The diffusion component contributes to the image beginning from the epidermal basal layer. The partial image produced by this component is more blurred compared to the partial image produced by to multiple scattering. The nondiffusion component forms the OCT skin image at depths up to {approx}1.3 mm. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗