Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Incremental online object learning in a vehicular radar-vision fusion framework

In this paper, we propose an object learning system that incorporates sensory information from an automotive radar system and a video camera. The radar system provides a coarse attention for the focus of visual analysis on relatively small areas within the image plane. The attended visual areas are coded and learned by a 3-layer neural network utilizing what is called in-place learning, where every neuron is responsible for the learning of its own signal processing characteristics within its connected network environment, through inhibitory and excitatory connections with other neurons. The modeled bottom-up, lateral, and top-down connections in the network enable sensory sparse coding, unsupervised learning and supervised learning to occur concurrently. The presented work is applied to learn two types of encountered objects in multiple outdoor driving settings. Cross validation results show the overall recognition accuracy above 95% for the radar-attended window images. In comparison with the uncoded representation and purely unsupervised learning (without top-down connection), the proposed network improves the recognition rate by 15.93% and 6.35% respectively. The proposed system is also compared with other learning algorithms favorably. The result indicates that our learning system is the only one to fit all the challenging criteria for the development of an incremental and online object learning system.

99 GENERAL AND MISCELLANEOUS↗

Used nuclear fuel dry storage cask materials monitoring system: a proof of concept to deploy retrieve monitoring equipment - 15504

The cask materials monitoring system is a proof-of-concept to deploy and retrieve monitoring equipment. The system is an airlock-type system that is bolted to the cask fill/drain port. It consists of the following major components: (1) a monitoring module that contains the equipment for monitoring the cask environment, (2) a sliding shield plug that provides radiation shielding throughout the deployment and retrieval of the monitoring equipment module, (3) a primary seal flange that is permanently installed on the cask that provides cask boundary confinement, and (4) a containment tube that provides the airlock function providing cask confinement when the primary seal is broken. In this proof-of-concept development, corrosion coupons were selected as the monitoring equipment for deployment into a spent nuclear fuel cask. However, the system has the potential for a variety of uses. The integration of a camera deployment system into the cask materials monitoring system will permit inspection of used nuclear fuel while maintaining cask atmosphere. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Multi-Chamber System for Analyzing the Outgassing, Deposition,and Associated Optical Degradation Properties of Materials in a Vacuum

We report on the Camera Materials Test Chamber, a multi-vessel apparatus which analyzes the outgassing consequences of candidate materials for use in the vacuum cryostat of a new telescope camera. The system measures the outgassing products and rates of samples of materials at different temperatures, and collects films of outgassing products to measure the effects on light transmission in six optical bands. The design of the apparatus minimizes potential measurement errors introduced by background contamination.

47 OTHER INSTRUMENTATION↗

Technical Note: High temporal resolution characterization of gating response time

Purpose: Low temporal latency between a gating ON/OFF signal and the LINAC beam ON/OFF during respiratory gating is critical for patient safety. Here the authors describe a novel method to precisely measure gating lag times at high temporal resolutions. Methods: A respiratory gating simulator with an oscillating platform was modified to include a linear potentiometer for position measurement. A photon diode was placed at linear accelerator isocenter for beam output measurement. The output signals of the potentiometer and diode were recorded simultaneously at 2500 Hz with an analog to digital converter for four different commercial respiratory gating systems. The ON and OFF of the beam signal were located and compared to the expected gating window for both phase and position based gating and the temporal lag times extracted. Results: For phase based gating, a real-time position management (RPM) infrared marker tracking system with a single camera and a RPM system with a stereoscopic camera were measured to have mean gate ON/OFF lag times of 98/90 and 86/44 ms, respectively. For position based gating, an AlignRT 3D surface system and a Calypso magnetic fiducial tracking system were measured to have mean gate ON/OFF lag times of 356/529 and 209/60 ms, respectively. Conclusions: Temporal resolution of the method was high enough to allow characterization of individual gate cycles and was primary limited by the sampling speed of the data recording device. Significant variation of mean gate ON/OFF lag time was found between different gating systems. For certain gating devices, individual gating cycle lag times can vary significantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiresolution approach based on projection matrices

Active triangulation measurement systems with a rigid geometric configuration are inappropriate for scanning large objects with low measuring tolerances. The reason is that the ratio between the depth recovery error and the lateral extension is a constant that depends on the geometric setup. As a consequence, measuring large areas with low depth recovery error requires the use of multiresolution techniques. We propose a multiresolution technique based on a camera-projector system previously calibrated. The method consists of changing the camera or projector's parameters in order to increase the system depth sensitivity. A subpixel retroprojection error in the self-calibration process and a decrease of approximately one order of magnitude in the depth recovery error can be achieved using the proposed method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-J-01: A Novel and Efficient Daily QA Program for Both Modern Linear Accelerator and Optical Surface Motion Systems

Purpose: The camera-based optical surface monitoring system(OSMS) is a standard motion-tracking system for TrueBeam™ machine. Daily quality assurance(DQA) procedures for the TrueBeam and OSMS systems currently require multiple phantoms and test sequences. Machine Performance Check(MPC) uses the IsoCal™ phantom to test geometric and dosimetric aspects, and has been validated for routine TrueBeam DQA. This work examines the novel use of MPC to simultaneously conduct DQA of OSMS,utilizing one phantom and test sequence for QA of both the TrueBeam and OSMS systems. Methods: TrueBeam with 6 degree-of-freedom(6DOF) couch, MPC and OSMS were installed. The therapists routinely use MPC with the IsoCal phantom to verify geometric and dosimetric parameters with an automated sequence of varying gantry and collimator angles, MLC positions, and couch translations and rotations as the DQA for TrueBeam. A surface outline of the IsoCal phantom, generated from a CT dataset, was imported to OSMS and used to monitor the position of the phantom at isocenter and to track its movement up to 5cm/10°(yaw) and rotation in pitch and roll up to 3° in real time during the automated MPC sequence. Motion of the phantom throughout the MPC routine was compared to the couch position shown by the digital readout. Results: The coincidence of isocenter, as determined by OSMS, and TrueBeam radiation isocenter was within ±0.8mm/±0.8° in three axes. Between OSMS and TrueBeam 6DOF couch, the mean couch relative shifts/angles were within ±0.7mm/±0.8° for each axis. Reported pitch and roll values were within ±0.4mm/±0.4°. The total measurement time for each DQA session took approximately 5 minutes. Conclusion: Use of the IsoCal phantom and MPC for simultaneous DQA of TrueBeam and OSMS increases QA efficiency and reduces complexity. OSMS isocenter position and motion-tracking capability in 6DOF were verified in real-time and were found to be within 1mm of the expected value.

60 APPLIED LIFE SCIENCES↗

Imaging system for cardiac planar imaging using a dedicated dual-head gamma camera

A cardiac imaging system employing dual gamma imaging heads co-registered with one another to provide two dynamic simultaneous views of the heart sector of a patient torso. A first gamma imaging head is positioned in a first orientation with respect to the heart sector and a second gamma imaging head is positioned in a second orientation with respect to the heart sector. An adjustment arrangement is capable of adjusting the distance between the separate imaging heads and the angle between the heads. With the angle between the imaging heads set to 180 degrees and operating in a range of 140-159 keV and at a rate of up to 500kHz, the imaging heads are co-registered to produce simultaneous dynamic recording of two stereotactic views of the heart. The use of co-registered imaging heads maximizes the uniformity of detection sensitivity of blood flow in and around the heart over the whole heart volume and minimizes radiation absorption effects. A normalization/image fusion technique is implemented pixel-by-corresponding pixel to increase signal for any cardiac region viewed in two images obtained from the two opposed detector heads for the same time bin. The imaging system is capable of producing enhanced first pass studies, bloodpool studies including planar, gated and non-gated EKG studies, planar EKG perfusion studies, and planar hot spot imaging.

47 OTHER INSTRUMENTATION↗

Chapter 18: Learning and Tracking Ad Hoc Fiducial Markers in Spatial Augmented Reality

We describe a spatial augmented reality system with a tangible user interface used to control computer simulations of complex systems. In spatial augmented reality, the user’s physical space is augmented with projected imagery, blending real objects with projected information, and a tangible user interface enables users to manipulate physical objects as controllers for interactive visualizations. Our system learns ad hoc objects in the user’s environment as fiducial markers (i.e., objects that are visually recognized and tracked). When combined with simulation and visualization tools, these interfaces allow the user to control simulations or ensembles of simulations via physical objects using apt metaphors. While other research has leveraged the use of depth cameras, our system enables the use of standard cameras in readily available smartphones and webcams and has an implementation that runs completely in JavaScript in the web browser. We discuss the prerequisite object-recognition requirements for such tangible user interfaces and describe computer-vision and machine-learning algorithms meeting those requirements. We conclude by presenting example applications, which are also available online.

energy distribution↗

Multi-MGy Radiation Hardened Camera for Nuclear Facilities

There is an increasing interest in developing cameras for surveillance systems to monitor nuclear facilities or nuclear waste storages. Particularly, for today's and the next generation of nuclear facilities increasing safety requirements consecutive to Fukushima Daiichi's disaster have to be considered. For some applications, radiation tolerance needs to overcome doses in the MGy(SiO{sub 2}) range whereas the most tolerant commercial or prototypes products based on solid state image sensors withstand doses up to few kGy. The objective of this work is to present the radiation hardening strategy developed by our research groups to enhance the tolerance to ionizing radiations of the various subparts of these imaging systems by working simultaneously at the component and system design levels. Developing radiation-hardened camera implies to combine several radiation-hardening strategies. In our case, we decided not to use the simplest one, the shielding approach. This approach is efficient but limits the camera miniaturization and is not compatible with its future integration in remote-handling or robotic systems. Then, the hardening-by-component strategy appears mandatory to avoid the failure of one of the camera subparts at doses lower than the MGy. Concerning the image sensor itself, the used technology is a CMOS Image Sensor (CIS) designed by ISAE team with custom pixel designs used to mitigate the total ionizing dose (TID) effects that occur well below the MGy range in classical image sensors (e.g. Charge Coupled Devices (CCD), Charge Injection Devices (CID) and classical Active Pixel Sensors (APS)), such as the complete loss of functionality, the dark current increase and the gain drop. We'll present at the conference a comparative study between these radiation-hardened pixel radiation responses with respect to conventional ones, demonstrating the efficiency of the choices made. The targeted strategy to develop the complete radiation hard camera electronics will be exposed. Another important element of the camera is the optical system that transports the image from the scene to the image sensor. This arrangement of glass-based lenses is affected by radiations through two mechanisms: the radiation induced absorption and the radiation induced refractive index changes. The first one will limit the signal to noise ratio of the image whereas the second one will directly affect the resolution of the camera. We'll present at the conference a coupled simulation/experiment study of these effects for various commercial glasses and present vulnerability study of typical optical systems to radiations at MGy doses. The last very important part of the camera is the illumination system that can be based on various technologies of emitting devices like LED, SLED or lasers. The most promising solutions for high radiation doses will be presented at the conference. In addition to this hardening-by-component approach, the global radiation tolerance of the camera can be drastically improve by working at the system level, combining innovative approaches eg. for the optical and illumination systems. We'll present at the conference the developed approach allowing to extend the camera lifetime up to the MGy dose range. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of mode activity in NBI-heated experiments of Wendelstein 7-X

The 2018 operation phase (OP 1.2b) of the stellarator Wendelstein 7-X (W7-X) included, for the first time, neutral beam injection (NBI) to heat the plasma. Since the injection geometry at W7-X is not parallel, this generates both passing and trapped fast particles. During longer phases of NBI injection, with the primary purpose to study the heating efficiency of this system, Alfvén eigenmodes (AEs) were observed by a number of diagnostics, including the phase contrast imaging (PCI) system, the magnetic pick-up coils (Mirnov coils), and the soft x-ray multi-camera tomography system (XMCTS). Alfvén eigenmodes are of great interest for future fusion reactors as it has been shown that the resonant interaction of fast ions with self-excited AEs can lead to enhanced transport of fast ions and potentially to energy losses. This is especially true for so-called gap-modes, Alfvén eigenmodes with frequencies in gaps of the continuous spectrum, since they lack continuum damping. These modes are commonly known to be excited by fast ions, but other destabilizing mechanisms, e.g. the electron-pressure gradient are also possible. In this article we present a first analysis of the experimentally observed frequencies from the theoretical side. The calculation of shear Alfvén wave continua for selected cases and the assignment of observed frequencies to the gaps of the continuous spectra are presented. Using the ideal-MHD code CKA (Könies A. 2007 10th IAEA TM on Energetic Particles in Magnetic Confinement System), we find gap modes that match the experimental measurements in terms of the observed frequencies. We emphasize the crucial roles played by the coupling of sound and Alfvén waves as well as of the Doppler shift arising as a consequence of the radial electric field in W7-X. We employ the perturbative gyrokinetic code CKA-EUTERPE (Feh´er 2013 Simulation of the interaction between Alfv´en waves and fast particles), using a slowing-down distribution function for the fast ions as calculated by the Monte-Carlo particle following code ASCOT (Hirvijoki et al 2014 Comput. Phys. Commun. 185 1310–21) to assess the fast-ion drive. Here we find that the fast-ion drive is insufficient to overcome the background-plasma damping. The fact that unstable modes were observed experimentally may point to problems with the modelling or indicate the existence of other destabilizing mechanisms, e.g. associated with the electron-pressure gradient (Windisch et al 2017 Plasma Phys. Control. Fusion 59 105002) that sensitively depend on the profiles of the background plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intelligent technique to search for patterns within images in massive databases

An image retrieval system for JET has been developed. The image database contains the images of the JET high speed visible camera. The system input is a pattern selected inside an image and the output is the group of frames (defined by their discharge numbers and time slices) that show patterns similar to the selected one. This approach is based on morphological pattern recognition and it should be emphasized that the pattern is found independently of its location in the frame. The technique encodes images into characters and, therefore, it transforms the pattern search into a character-matching problem.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LiDAR-Aided Interior Orientation Parameters Refinement Strategy for Consumer-Grade Cameras Onboard UAV Remote Sensing Systems

Unmanned aerial vehicles (UAVs) are quickly emerging as a popular platform for 3D reconstruction/modeling in various applications such as precision agriculture, coastal monitoring, and emergency management. For such applications, LiDAR and frame cameras are the two most commonly used sensors for 3D mapping of the object space. For example, point clouds for the area of interest can be directly derived from LiDAR sensors onboard UAVs equipped with integrated global navigation satellite systems and inertial navigation systems (GNSS/INS). Imagery-based mapping, on the other hand, is considered to be a cost-effective and practical option and is often conducted by generating point clouds and orthophotos using structure from motion (SfM) techniques. Mapping with photogrammetric approaches requires accurate camera interior orientation parameters (IOPs), especially when direct georeferencing is utilized. Most state-of-the-art approaches for determining/refining camera IOPs depend on ground control points (GCPs). However, establishing GCPs is expensive and labor-intensive, and more importantly, the distribution and number of GCPs are usually less than optimal to provide adequate control for determining and/or refining camera IOPs. Moreover, consumer-grade cameras with unstable IOPs have been widely used for mapping applications. Therefore, in such scenarios, where frequent camera calibration or IOP refinement is required, GCP-based approaches are impractical. To eliminate the need for GCPs, this study uses LiDAR data as a reference surface to perform in situ refinement of camera IOPs. The proposed refinement strategy is conducted in three main steps. An image-based sparse point cloud is first generated via a GNSS/INS-assisted SfM strategy. Then, LiDAR points corresponding to the resultant image-based sparse point cloud are identified through an iterative plane fitting approach and are referred to as LiDAR control points (LCPs). Finally, IOPs of the utilized camera are refined through a GNSS/INS-assisted bundle adjustment procedure using LCPs. Seven datasets over two study sites with a variety of geomorphic features are used to evaluate the performance of the developed strategy. The results illustrate the ability of the proposed approach to achieve an object space absolute accuracy of 3–5 cm (i.e., 5–10 times the ground sampling distance) at a 41 m flying height.

47 OTHER INSTRUMENTATION↗

OpenCSP Camera Calibration: Document Version 1.0

This report provides instructions on how to perform an OpenCSP camera lens calibration, which characterizes the inherent distortion in camera-lens systems. This calibration is necessary for many OpenCSP photogrammetry calculations and should be performed individually for every new camera or after adjusting lens settings.

42 ENGINEERING↗

Ultrathin Optics for Low-Profile Innocuous Imager

This project demonstrates the feasibility of a novel imager with a thickness measured in microns rather than inches. Traditional imaging systems, i.e. cameras, cannot provide both the necessary resolution and innocuous form factor required in many data acquisition applications. Designing an imaging system with an extremely thin form factor (less than 1 mm) immediately presents several technical challenges. For instance, the thickness of the optical lens must be reduced drastically from currently available lenses. Additionally, the image circle is reduced by a factor equal to the reduction in focal length. This translates to fewer detector pixels across the image. To reduce the optical total track requires the use of specialized micro-optics and the required resolution necessitates the use of a new imaging modality. While a single thin imager will not produce the desired output, several thin imagers can be multiplexed and their low resolution (LR) outputs used together in post-processing to produce a high resolution (HR) image. The utility of an Iterative Back Projection (IBP) algorithm has been successfully demonstrated for performing the required post-processing. Advanced fabrication of a thin lens was also demonstrated and experimental results using this lens as well as commercially available lenses are presented.

47 OTHER INSTRUMENTATION↗

Use of Data Libraries for IAEA Nuclear Security Assessment Methodologies (NUSAM) [section 5.4]

Data libraries are essential for the characterization of the facility and provide the documented input which enables the facility assessment results and subsequent conclusions. Data Libraries are historical, verifiable, quantified, and applicable collections of testing data on different types of barriers, sensors, cameras, procedures, and/or personnel. Data libraries are developed and maintained as part of any assessment program or process. Data is collected during the initial stages of facility characterization to aid in the model and/or simulation development process. Data library values may also be developed through the use of state testing centers and/or site resources by testing different types of barriers, sensors, cameras, procedures, and/or personnel. If no data exists, subject matter expert opinion and manufacturer's specifications/ testing values can be the basis for initially assigning values, but are generally less reliable and lack appropriate confidence measures. The use of existing data libraries that have been developed by a state testing organization reduces the assessment costs by establishing standard delay, detection and assessment values for use by multiple sites or facilities where common barriers and alarms systems exist.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Poster — Thur Eve — 23: Dose and Position Quality Assurance using the RADPOS System for 4D Radiotherapy with CyberKnife

Introduction: RADPOS 4D dosimetry system consists of a microMOSFET dosimeter combined with an electromagnetic positioning sensor, which allows for performing real-time dose and position measurements simultaneously. In this report the use of RADPOS as an independent quality assurance (QA) tool during CyberKnife 4D radiotherapy treatment is described. In addition to RADPOS, GAFCHROMIC® films were used for simultaneous dose measurement. Methods: RADPOS and films were calibrated in a Solid Water® phantom at 1.5 cm depth, SAD= 80 cm, using 60 mm cone. CT based treatment plan was created for a Solid Water® breast phantom containing metal fiducials and RADPOS probe. Dose calculations were performed using iPlan pencil beam algorithm. Before the treatment delivery, GAFCHROMIC® film was inserted inside the breast phantom, next to the RADPOS probe. Then the phantom was positioned on the chest platform of the QUASAR, to which Synchrony LED optical markers were also attached. Position logging began for RADPOS and the Synchrony tracking system, the QUASAR motion was initiated and the treatment was delivered. Results: RADPOS position measurements very closely matched the LED marker positions recorded by the Synchrony camera tracking system. The RADPOS measured dose was 2.5% higher than the average film measured dose, which is within the experimental uncertainties. Treatment plan calculated dose was 4.1 and 1.6% lower than measured by RADPOS and film, respectively. This is most likely due to the inferior nature of the dose calculation algorithm. Conclusions: Our study demonstrates that RADPOS system is a useful tool for independent QA of CyberKnife treatments.

07 ISOTOPE AND RADIATION SOURCES↗

A novel, cost-effective, multi-point Thomson scattering system on the Pegasus Toroidal Experiment (invited)

Here, a novel, cost-effective, multi-point Thomson scattering system has been designed, implemented, and operated on the Pegasus Toroidal Experiment. Leveraging advances in Nd:YAG lasers, high-efficiency volume phase holographic transmission gratings, and increased quantum-efficiency Generation 3 image-intensified charge coupled device (ICCD) cameras, the system provides Thomson spectra at eight spatial locations for a single grating/camera pair. The on-board digitization of the ICCD camera enables easy modular expansion, evidenced by recent extension from 4 to 12 plasma/background spatial location pairs. Stray light is rejected using time-of-flight methods suited to gated ICCDs, and background light is blocked during detector readout by a fast shutter. This –10 3 reduction in background light enables further expansion to up to 24 spatial locations. The implementation now provides single-shot T e (R) for n e > 5 × 10 18 m –3 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of the Triple Theta assembly station with machine vision feedback

Increased requirements for tighter tolerances on assembled target components in complex three-dimensional geometries with only days to assemble complete campaigns require the implementation of a computer-controlled high-precision assembly station. Over the last year, an 11-axis computer-controlled assembly station has been designed and built with custom software to handle the multiple coordinate systems and automatically calculate all relational positions. Preliminary development efforts have also been done to explore the benefit of a machine vision feedback module with a dual-camera viewing system to automate certain basic features like crosshair calibration, component leveling, and component centering.

36 MATERIALS SCIENCE↗