Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Nucleate pool boiling heat transfer characteristics of TiO{sub 2}-water nanofluids at very low concentrations

A study of nucleate pool boiling heat transfer of TiO{sub 2}-water nanofluids is experimentally conducted. Nanofluids with various concentrations of 0.00005, 0.0001, 0.0005, 0.005, and 0.01 vol.% are employed. Horizontal circular plates made from copper and aluminium with different roughness values of 0.2 and 4 {mu}m are used as heating surfaces. The experiments are performed to explore the effects of nanofluids concentration as well as heating surface material and roughness on nucleate pool boiling characteristics and the heat transfer coefficient under ambient pressure. The results show that based on the copper heated surface which is tested with a concentration of 0.0001 vol.%, higher nucleate pool boiling heat transfer coefficient is obtained when compared with the base fluid. A 15% increase is obtained for the surface roughness of 0.2 {mu}m and a 4% increase is obtained for roughness of 4 {mu}m. For concentrations higher than 0.0001 vol.%, however, the higher the concentration, the lower the heat transfer coefficient. In the case of aluminium heated surface, the corresponding heat transfer coefficients are larger than for the copper surface by around 30% with a roughness of 0.2 {mu}m and around 27% with a roughness of 4 {mu}m. Moreover, the results also indicate that the heat transfer coefficient obtained based on a roughness of 4 {mu}m is higher than that for a roughness of 0.2 {mu}m by around 12% for aluminium and by around 13% for copper. (author)

42 ENGINEERING↗

Bubble confinement in flow boiling of FC-72 in a ''rectangular'' microchannel of high aspect ratio

Boiling in microchannels remains elusive due to the lack of full understanding of the mechanisms involved. A powerful tool in achieving better comprehension of the mechanisms is detailed imaging and analysis of the two-phase flow at a fundamental level. Boiling is induced in a single microchannel geometry (hydraulic diameter 727 {mu}m), using a refrigerant FC-72, to investigate the effect of channel confinement on bubble growth. A transparent, metallic, conductive deposit has been developed on the exterior of the rectangular microchannel, allowing simultaneous uniform heating and visualisation to be achieved. The data presented in this paper is for a particular case with a uniform heat flux applied to the microchannel and inlet liquid mass flowrate held constant. In conjunction with obtaining high-speed images and videos, sensitive pressure sensors are used to record the pressure drop across the microchannel over time. Bubble nucleation and growth, as well as periodic slug flow, are observed in the microchannel test section. The periodic pressure fluctuations evidenced across the microchannel are caused by the bubble dynamics and instances of vapour blockage during confined bubble growth in the channel. The variation of the aspect ratio and the interface velocities of the growing vapour slug over time, are all observed and analysed. We follow visually the nucleation and subsequent both 'free' and 'confined' growth of a vapour bubble during flow boiling of FC-72 in a microchannel, from analysis of our results, images and video sequences with the corresponding pressure data obtained. (author)

42 ENGINEERING↗

Enhanced pool boiling heat transfer with metal foam tubes in inline tube bundle configuration

Flooded evaporators, commonly known as shell-and-tube heat exchangers, are widely used in large-scale industrial refrigeration and air-conditioning systems due to their high pool boiling heat transfer efficiency. However, their bulky configuration requires a large refrigerant inventory, which poses safety challenges—particularly when employing next-generation A2L refrigerants that are mildly flammable. Here, to address this issue, the development of compact heat exchangers with enhanced heat transfer performance is essential. In this study, a novel metal foam tube design is proposed to augment pool boiling heat transfer. Experiments were conducted at a saturation temperature of 20 °C and across a heat flux range of 7–60 kW m −2 . The tests were conducted for both smooth and metal foam tubes with an inline tube bundle configuration and for a pitch–to–diameter (P/D) ratios of 1.3 and 1.5. Pool boiling performance was evaluated for next-generation hydrofluoroolefin (HFO) refrigerants, R1234yf and R1234ze(E), with R134a serving as the baseline fluid. The results indicate that the heat transfer coefficient (HTC) of R1234yf is comparable to R134a, while R1234ze(E) shows slightly lower performance. Importantly, the metal foam tubes achieved up to a 217% enhancement in HTC compared to smooth tubes.

Metal foam tubes↗

High salinity seawater boiling point elevation: Experimental verification

Boiling point elevation (BPE) for high salinity solutions is a crucial parameter that significantly affects the overall thermal efficiency of desalination, water treatment, and many other industrial processing systems, especially when minimum or zero liquid discharge is a key requirement. This paper addresses the discrepancies among the empirical correlations reported in the literature that were commonly used to determine BPE for seawater solutions. An evaluation of the experimental data with low solution concentration reveals that the data cannot be extrapolated to determine the BPE at high concentration (X > 140 ppt or g/kg). Besides, disparities are established within different equations used to determine the BPE for high salinity seawater. As a result of the minimal availability of experimental data of BPE for X > 140 ppt and the need to eliminate the discrepancies, an experimental setup was built, which can produce reliable and repeatable BPE data for any solution concentration. Boiling points were obtained experimentally for seawater solutions with a wide range of salinity (X between 20 and 280 ppt) and brine solution temperature (t b between 20 and 80°C). The experimental results of boiling point elevations for seawater are further compared with the experimental data and analytical results reported in the literature. The newly obtained experimental results show that the minimum and maximum BPE values for the brine solutions tested are 0.175°C at t b = 80°C and X = 20 ppt, and 11.6°C at t b = 80°C and X = 280 ppt, respectively. Furthermore, the measured BPE data for seawater concentration over 80 ppt are fitted and presented using an appropriate fitting model. The new correlation can accurately predict the BPE for high salinity seawater brines and thus should be very helpful in the design of high-energy-efficient evaporation systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental investigations of boiling heat transfer hysteresis on sintered, metal - Fibrous, porous structures

The paper discusses the results of experimental investigations of boiling heat transfer on sintered metal capillary-porous coverings of the heating surface. The experiments were carried out for copper, fibrous structures with stochastic distribution of pores. The boiling curves were obtained at the increasing and decreasing of the heat flux, which made it possible to detect the hysteresis phenomena of different types. The classification of the hysteresis phenomena, based on the author's own results and those available in the literature, was provided. Three types of hysteresis were observed. The physical mechanism of the phenomenon was presented and the features characteristic of boiling in the porous covering were taken into account. (author)

42 ENGINEERING↗

Roughness and surface material effects on nucleate boiling heat transfer from cylindrical surfaces to refrigerants R-134a and R-123

This paper presents results of an experimental investigation carried out to determine the effects of the surface roughness of different materials on nucleate boiling heat transfer of refrigerants R-134a and R-123. Experiments have been performed over cylindrical surfaces of copper, brass and stainless steel. Surfaces have been treated by different methods in order to obtain an average roughness, Ra, varying from 0.03 {mu}m to 10.5 {mu}m. Boiling curves at different reduced pressures have been raised as part of the investigation. The obtained results have shown significant effects of the surface material, with brass being the best performing and stainless steel the worst. Polished surfaces seem to present slightly better performance than the sand paper roughened. Boiling on very rough surfaces presents a peculiar behavior characterized by good thermal performance at low heat fluxes, the performance deteriorating at high heat fluxes with respect to smoother surfaces. (author)

42 ENGINEERING↗

Numerical analysis of coalescence-induced bubble departure for enhanced boiling heat transfer

Boiling heat transfer plays a crucial role in a wide range of applications, such as power generation, refrigeration, electronics cooling, and pharmaceutics. Among the various factors that influence boiling heat transfer, the dynamics of vapor bubble nucleation, growth, and departure from the heated surface stand out as particularly important. An emerging phenomenon that can promote the departure of bubbles smaller than the Fritz diameter is coalescence-induced departure. If the dynamics of this process are fully understood, then surfaces can be engineered to promote faster bubble departure and substantially increase the performance of boiling heat transfer. Further, this work expands on published results by presenting a detailed numerical analysis of bubble coalescence and departure for a range of initial bubble diameters and size ratios between coalescing bubbles. Analysis of the results is focused on explaining how the release of surface energy and bubble surface dynamics lead to bubble departure, as well as fundamentally distinguishing capillary–inertial jumping and buoyant–inertial departure mechanisms across different bubble sizes and size ratios. The results show that both the initial sizes of the coalescing bubbles and the ratio between their sizes can determine whether the merged bubble will leave the surface through capillary–inertial jumping or buoyant departure. Below a certain bubble size, the release of surface energy by the merger is not sufficient to propel the merged bubble from the surface.

42 ENGINEERING↗

Comparison of steady and transient flow boiling critical heat flux for FeCrAl accident tolerant fuel cladding alloy, Zircaloy, and Inconel

Steady and transient (with a heating rate of 685?/s) internal-flow CHF (Critical Heat Flux) experiments were conducted under atmospheric pressure at a fixed inlet temperature (40? or 60?) and mass flow (300kg/m 2 s) on Fe-13Cr-6Al alloy, Inconel 600 and Zircaloy-4 tube samples. Multiple experiments were repeated on the same specimen to investigate the effect of surface characteristic changes (i.e., roughness, wettability, and oxide scale morphology) on the occurrence of CHF. Despite notable changes of wettability, roughness, and oxide layer characteristics on samples that had already been subjected to CHF, measured flow CHF remained unchanged throughout repeated experiments for tested materials. This demonstrates that the surface effects on flow CHF are limited in the test conditions. In the steady-state flow boiling condition, Fe-13Cr-6Al alloy demonstrated a 22% and 14% increase in CHF compared to Zircaloy-4 and Inconel 600, respectively. Compared to the 2006 Groeneveld CHF lookup table, Fe-13Cr-6Al alloy gives a 13% increase in the tested flow boiling condition. Material properties are considered primarily responsible for the observed CHF differences among the tested materials. The surface thermal economy parameter $\frac{(pc_p)^{3/2}}{\sqrt{k}}$ is proposed as an explanation for the observed CHF differences; this parameter is related to material’s ability to avoid an irreversible dry spot formation. The apparent disagreement of Zircaloy-4 CHF with both the look up table predictions and Inconel 600 shows the limitation of departure of nuclate boiling (DNB) evaluations that do not consider cladding materials. The transient Fe-13Cr-6Al CHF is 39% and 23% higher than the lookup table prediction and the steady-state condition experimental result, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study of the film boiling heat transfer and two-phase flow interface behavior using image processing

Here, in this study, based on a small-scale quench test facility, the two-phase flow interface behavior during quench transients is visualized and analyzed utilizing an image processing framework. The high-fidelity experimental results obtained for two-phase flow in the current framework can support various studies both in the time domain and in the frequency domain. In particular, visualization of the data obtained from different heating surfaces under different test conditions are used to perform a full-scale transient 2-D vapor film reconstruction. The liquid-vapor interface variations in various heat transfer regimes as well as at the initial film breakup point can be directly obtained through the processed data. Moreover, the temporal variation of the interfacial wave frequency approaching quench is investigated in detail. Based on the high-resolution data obtained for the liquid-vapor interface, the detailed phase velocity and temperature profiles are obtained through theoretic analysis, based on which the film boiling heat transfer coefficient (HTC) can be determined. In addition, an improved film boiling HTC model is developed considering the effects of wall superheat, liquid subcooling temperature, vapor film thickness as well as fluid properties. The model is found to predict film boiling HTC well within 15% error.

42 ENGINEERING↗

Towards understanding the development and characteristics of under-expanded flash boiling jets

Here in this research, the n-hexane jets discharged from a straight channel were studied numerically to reveal the development and characteristics of under-expanded flashing jets. Firstly, the development of flash boiling jets was investigated and compared to that of two-phase jets without phase transition. It was shown that the two-phase jets without phase transition can be under-expanded only if the flow is choked. In contrast, flash boiling jets can be under-expanded whether or not the choked conditions are verified. Secondly, the factors affecting the flashing jet behaviors were discussed. The relaxation time in phase transition, the expansion ratio, and the injection pressure have been identified as three key factors determining the jet characteristics. With high enough expansion ratio and low enough relaxation time, the expansion was so strong that the flow became transonic and shock structures similar to those of under-expanded gaseous jets appeared near the orifice exit. Finally, two types of choking have been identified for flash boiling jets, i.e., vaporization-induced choking and expansion-induced choking. The former one is mainly ascribed to the vapor formation in the orifice which reduces the local speed of sound, while the latter one is due to the expansion of under-expanded two-phase flow and the resultant flow acceleration.

42 ENGINEERING↗

New flow boiling heat transfer model for hydrocarbons evaporating inside horizontal tubes

Hydrocarbons have high thermodynamic performances, belong to the group of natural refrigerants, and they are the main components in mixture Joule-Thomson low temperature refrigerators (MJTR). New evaluations of nucleate boiling contribution and nucleate boiling suppression factor in flow boiling heat transfer have been proposed for hydrocarbons. A forced convection heat transfer enhancement factor correlation incorporating liquid velocity has also been proposed. In addition, the comparisons of the new model and other classic models were made to evaluate its accuracy in heat transfer prediction.

42 ENGINEERING↗

Visualization of R410A Flow Boiling Inside Horizontal Smooth Tubes under Diabatic Conditions

This article presents a novel approach to visualize the flow boiling in round tubes under “diabatic conditions”. In the visualization test section, a 3D printed round tube is placed inside a glass tube with secondary fluid at a higher temperature flowing in the annulus between the two tubes thus providing diabatic conditions. Experimental work was conducted for evaporating R410A flow in a horizontal smooth round tube with the inner diameter of 6.3 mm. Compared to the traditional adiabatic visualization technique, the more realistic evaporative condition is simulated and the developing evaporation process is captured. New insights for the flow behavior at low vapor quality are brought by this diabatic method. The vapor plug occurs at very low vapor quality, and this is attributed to the coalescence of bubbles generated on the heated tube wall. For the intermittent flow, liquid slug triggered by Kelvin–Helmholtz instability affects the nucleation on the tube wall. It brings the fresh liquid to rewet the dry surface and activate the nucleation sites. Finally, heat flux condition affects the heat transfer mechanisms during the flow boiling, and the heat transfer through the nucleate boiling mechanism increases as the heat flux increases.

3D printed↗

Boiling and cavitation caused by transient heat transfer in superfluid helium-4

Superfluid helium-4 (He II) has been widely utilized as a coolant in various scientific and engineering applications due to its superior heat transfer capability. An important parameter required in the design of many He II based cooling systems is the peak heat flux $q^*$, which refers to the threshold heat flux above which boiling spontaneously occurs in He II. Past experimental and numerical studies showed that $q^*$ increases when the heating time $t_h$ is reduced, which leads to an intuitive expectation that very high $q^*$ may be achievable at sufficiently small $t_h$. Knowledge on how $q^*$ actually behaves at small $t_h$ is important for applications such as laser ablation in He II. Furthermore we present a numerical study on the evolution of the thermodynamic state of the He II in front of a planar heater by solving the He II two-fluid equations of motion. For an applied heat flux, we determine the heating time beyond which the He II near the heater transits to the vapor phase. As such, a curve correlating $q^*$ and $t_h$ can be obtained, which nicely reproduces some relevant experimental data. Surprisingly, we find that there exists a critical peak heat flux $q^*_c$, above which boiling occurs nearly instantaneously regardless of $t_h$. We reveal that the boiling in this regime is essentially cavitation caused by the combined effects of the first-sound and the second-sound waves in He II. Based on this physical picture, an analytical model for $q^*_c$ is developed, which reproduces the simulated $q^*_c$ values at various He II bath temperatures and hydrostatic head pressures. This work represents a major progress in our understanding of transient heat transfer in He II.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

R and D program for French sodium fast reactor: On the description and detection of sodium boiling phenomena during sub-assembly blockages

In support of the French ASTRID (Advanced Sodium Technological Reactor for Industrial Demonstration) reactor program, which aims to demonstrate the industrial applicability of sodium fast reactors with an increased level of safety demonstration and availability compared to the past French sodium fast reactors, emphasis is placed on reactor instrumentation. It is in this framework that CEA studies continuous core monitoring to detect as early as possible the onset of sodium boiling. Such a detection system is of particular interest due to the rapid progress and the consequences of a Total Instantaneous Blockage (TIB) at a subassembly inlet, where sodium boiling intervenes in an early phase. In this paper, the authors describe all the particularities which intervene during the different boiling stages and explore possibilities for their detection. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Incredible Effect of Heat Load Increase Rate on the Specific Heat Flux at Boiling of Some Nanofluids

Boiling curves for different heat-load increase rates (HLIRs) are obtained for distilled water, tap water, and two nanofluids (NFs) based on a natural mixture of montmorillonite and attapulgite (AlSi-7) and titanium dioxide (NF-8). An unusually strong influence of the HLIR on the thermal parameters of NFs is detected upon boiling of AlSi-7 based on a mixture of highly anisometric nanoparticles of aluminosilicates of various morphologies capable of forming nanostructured openwork “architectures” on the heater surface. An explanation of the reasons for the observed effect is proposed. The data obtained indicate the existence of an optimal HLIR at which the structure of the deposit appearing on the heating surface during the boiling of an NF is most favorable for heat exchange.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

In-cylinder spray evolution in a motored central-injection gasoline engine: Imaging and simulating the effects of flash-boiling and intake crossflow

Accurate predictions of fuel spray behavior and mixture formation in simulations of direct-injection spark-ignition (DISI) engines are fundamental to ensure proper description of all subsequent processes including ignition, combustion, and emissions. In this work, the spray evolution in a single-cylinder optical DISI engine was studied experimentally and numerically with the goal of enabling predictive computational fluid dynamics (CFD) modeling of in-cylinder sprays. The authors explored a wide range of operating conditions characterized by several fuel injection temperatures and engine speeds, using a well-characterized nine-component gasoline surrogate known as PACE-20. The effect of flash boiling and intake crossflow on the spray is discussed, with a focus on evaluating the ability of the spray models to capture highly transient spray behavior. In the experiments, the fuel temperature was varied between 20°C and 80°C, allowing for non-flash- to flash-boiling transition to emerge with enhanced flashing intensity at the highest temperatures. Spray collapse resulted in vapor-rich regions, owing to the locally lower inertia of the fluid. Varying the engine speed from 650 to 1950 rpm promoted increasingly more turbulent in-cylinder crossflow which interacted with the spray during the injection event and resulted in enhanced spray dispersion. The CFD model was able to capture the spray morphology transition at different fuel temperatures and engine speeds adequately. Further, it is shown that the spray breakup model could capture the transitional spray behavior induced by flash boiling atomization and intake flow via proper initialization of the spray cone angle and calibration of the spray models’ constants.

33 ADVANCED PROPULSION SYSTEMS↗

Flow boiling of R134a in a large surface area microchannel array for high-flux laser diode cooling

Packaging high average power laser diode arrays that generate heat at an area average flux in excess of 1 kW·cm -2 is a significant engineering challenge. While liquid microchannel coolers have demonstrated up to 11.9 kW·cm -2 , two-phase microchannel array coolers have not achieved 1 kW cm -2 due to critical heat flux and flow instabilities. In the current study, flow boiling heat transfer was characterized by a 1 &times; 10 mm heated zone centered over a 5 &times; 10 mm array of 125 very small channels (45 &times; 200 &mu;m) with R134a as the phase change fluid. The high aspect ratio channels (4.4:1) were manufactured using MEMS fabrication techniques, which yielded a large heat transfer surface area to volume ratio. A test facility was used to characterize the heat transfer performance of boiling R134a over a range of saturation temperatures (15&deg;C to 25&deg;C), mass fluxes (735-2230 kg·m -2 ·s -1 ), and heat duties (< 110.3 W). During the tests, the calculated outlet vapor quality exceeded 61%, and the base heat flux at the heater reached a maximum of 1.1 kW·cm -2 . The resulting average experimental flow boiling heat transfer coefficients are found to be as large a 13.4 kW·m -2 ·K -1 over the approximately 3 mm two-phase region, with an average uncertainty of ± 2.72%. A substantial amount of heat was spread downstream via the low thermal resistance silicon floor. Specifically, between 29.5% and 55.1% of the heat dissipated in the two-phase region was dissipated over the heater. Finally, the remaining heat dissipated in the two-phase region was dissipated in the 2 mm of channel downstream of the heater. This suggests that heat spreading from the hotspot played a vital role in dissipating the heat load.

42 ENGINEERING↗

Evaluation of CASL boiling model for DNB performance in full scale 5x5 fuel bundle with spacer grids

As one of main tasks for FY17 CASL-THM activity, Evaluation study on applicability of the CASL baseline boiling model for 5x5 DNB application is conducted and the predictive capability of the DNB analysis is reported here. While the baseline CASL-boiling model (GEN- 1A) approach has been successfully implemented and validated with a single pipe application in the previous year’s task, the extended DNB validation for realistic sub-channels with detailed spacer grid configurations are tasked in FY17. The focus area of the current study is to demonstrate the robustness and feasibility of the CASL baseline boiling model for DNB performance in a full 5x5 fuel bundle application. A quantitative evaluation of the DNB predictive capability is performed by comparing with corresponding experimental measurements (i.e. reference for the model validation). The reference data are provided from the Westinghouse Electricity Company (WEC). Two different grid configurations tested here include Non-Mixing Vane Grid (NMVG), and Mixing Vane Grid (MVG). Thorough validation studies with two sub-channel configurations are performed at a wide range of realistic PWR operational conditions.

42 ENGINEERING↗