The 1972 Summer Institute for Biomedical Engineering
Design of hemoglobin tester, flow ventilation systems, blood viscometer, isotope handling equipment, and blood pressure measuring device
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Design of hemoglobin tester, flow ventilation systems, blood viscometer, isotope handling equipment, and blood pressure measuring device
The status of projects involving the adaptation of NASA technologies for medical purposes is reviewed. Devices for the measurement of joint deformation of arthritic hands, the development of an artificial pancreas, provision of an auditory signal to avert epileptic seizures, are described along with the control of medication levels, a compressed air tank to supply power for field dentistry, and an electroencephalogram monitor. The use of the Lixiscope as a portable fluoroscope, thermal laminates for hand and foot warmers for patients with Raynaud's syndrome, and the use of absorptive coatings for instruments for controlling medication levels are described. The applicability of occupation health and safety practices to industry, computerized patient scheduling, impregnation of the common facial tissue with an agent for killing respiratory viruses, commercial applications of anthropometric data, and multispectral image analysis of the skin as a diagnostic tool are reviewed.
Detection of the handful of photons generated when a dark matter particle interacts in a liquid Xenon detector requires a new type of photodetector with very high detection efficiency at ultraviolet wavelengths, very low radioactive backgrounds, and essentially no measureable readout noise (achieved with devices with high intrisic gain). Such devices would find wide applicability to not only high energy physics experiments, but to a number of commercial applications including, e.g., biomedical imaging of fluorescent tags. We developed photodetectors based on amorphous GaN thin film structures (photocathodes) grown by molecular beam epitaxy on quartz windows. We also developed approaches to integrate these photocathode device structures with vacuum electron multipliers. All materials and fabrication techniques were developed to minimize radioactive backgrounds in materials, so these detectors could be used for very low count rate experiments, such as the future liquid-Xenon dark matter detectors, and future liquid-Argon neutrino detectors. We demonstrated growth of very high quantum efficiency amorphous GaN cathodes grown on a number of different substrates (Stainless steel, p-Silicon) reaching detection efficiencies of 80% at 220nm. The key to this growth was to use nitrogen plasma-assistend MBEs and very low growth temperatures. We also discovered that thinner structures (e.g.,40nm a-GaN thin films) had the best performance. We successfully demonstrated techniques for the vacuum transfer of these photocathode structures to a novel chamber that used hydraulics and bellow to form a cold indium bond needed to integrate these cathodes into sealed-tube devices. A complete, stand-along, device could not be completed during this proposal period due to difficulties in growing structures on the thick quartz window. Subsequent work is aimed at addressing this difficulty, by growing a buffer layer on the quartz substrate.
The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographic system using techniques comparable to chest radiography. The phantom design enabled observer evaluation by a four-alternative forced choice paradigm. The acquired images were independently scored by five observers on five medical display devices: a 5 megapixel monochrome LCD, a 3 megapixel monochrome LCD, a 9 megapixel color LCD, a 5 megapixel monochrome CRT, and a mammographic-grade monochrome CRT. The data were analyzed using the method suggested by the manufacturer based on a nearest neighbor correction technique. They were further analyzed using a logistic regression response model with a natural threshold using an overall chi-square test for display type followed by pairwise comparisons for individual display performance. The differences between the display devices were small. The standard analysis of the results based on the manufacturer-recommended method did not yield any statistically discernible trend among displays. The logistic regression analysis, however, indicated that the 5 megapixel monochrome LCD was statistically significantly (p<0.0001) superior to the others, followed by the 3 megapixel monochrome LCD (p<0.0001). The three other displays exhibited lower but generally similar performance characteristics. The findings suggest that 5 and 3 megapixel monochrome LCDs provide comparable but subtly superior contrast detectability than other tested displays, with the former performing slightly better in the detection of subtle and fine details.
High‐resolution 3D printing technologies are enabling a new generation of microstructured materials for applications where biocompatibility is critical. However, most conventional 3D‐printable resins yield materials that exhibit trade‐offs between antifouling properties and mechanical robustness, limiting their applicability in living systems. In nature, zwitterionic surface groups form tightly bound hydration layers that act as effective barriers against protein and cell attachment. Inspired by this strategy, a zwitterionic acrylamide‐based photoresist—carboxybetaine di‐methacrylamide (CBDA)—is developed for projection‐based vat photopolymerization, enabling the fabrication of complex microarchitectures with exceptional antifouling properties. The bifunctional monomer allows the formation of dense, cross‐linked networks that resist swelling while maintaining a high density of zwitterionic groups. Printed structures exhibit strong resistance to protein and cell adhesion, as confirmed by porcine blood assays, alongside robust mechanical performance. As a demonstration, a tubular structure featuring a negative Poisson's ratio lattice is printed to showcase structural fidelity and versatility. This resin formulation offers a broadly applicable strategy for fabricating microscale devices and surfaces where antifouling performance and structural integrity are both essential—spanning biomedical interfaces, soft robotics, and beyond.
Shape memory polymers (SMPs) are a rapidly emerging class of smart materials that can be stored in a deformed temporary shape, and can actively return to their original shape upon application of an external stimulus such as heat, pH or light. This behavior is particularly advantageous for minimally invasive biomedical applications comprising embolic/regenerative scaffolds, as it enables a transcatheter delivery of the device to the target site. The focus of this work was to exploit this shape memory behavior of polyurethanes, and develop an efficient embolic SMP foam device for the treatment of intracranial aneurysms.In summary, this work reports a novel family of ultra low density polymer foams which can be delivered via a minimally invasive surgery to the aneurysm site, actuated in a controlled manner to efficiently embolize the aneurysm while promoting physiological fluid/blood flow through the reticulated/open porous structure, and eventually biodegrade leading to complete healing of the vasculature.
The Lawrence Livermore National Laboratory Center for Micro and Nanotechnology (CMNT) is located on the LLNL campus in Livermore, CA. LLNL employs over 7000 employees with a broad range of science and engineering backgrounds with an administrative structure that encourages multidisciplinary teaming, a key ingredient in our ability to address diverse technical problems. Our CMNT facility houses a 6,400 ft 2 class 100 cleanroom (class 10 capable) with an additional 1,000 ft 2 Class 1000 space, and 6000 ft 2 of other laboratories. Most equipment can accommodate 6” wafers, although some is limited to 4”. The CMNT is a multi-user, multi-programmatic facility that offers a broad set of instruments for microfabrication to invent, develop, and apply microscale and nanoscale technologies to support national security missions in Stockpile Stewardship, Homeland Security, Directed Energy, Nonproliferation, biomedical research, and more. The research and capabilities of the Center cover materials, devices, instruments, and systems that require microfabricated components, including microelectromechanical systems (MEMS), electronics, photonics, micro- and nanostructures, bio-implantable devices, and micro- and nanoactuators.
Inspired by the ideas of many authors, we provide insight on state-of-the-art potential technologies for the prevention and prediction of infectious diseases before they spread. This review also surveys virus sterilization with ultraviolet light and low temperature plasma technologies. Researchers in the various fields of medicine, materials, electronics, and plasma sciences have addressed increasingly challenging demands and the discussion encompasses the major challenges in societies that are faced with the threat of infectious diseases. In addition, technologies that use nanomaterials are evaluated for infection prevention and hygiene purposes. Advances in biomedical diagnostics for health care in terms of complementary metal-oxide-semiconductor transistors-based devices and telemetry for health monitoring are also reviewed.
Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited. Therefore, compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Rigorous testing of these proposed devices in space flight is difficult so computational modeling provides an estimation of the muscle forces and joint loads during exercise to gain insight on the efficacy to protect the musculoskeletal health of astronauts. The NASA Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) project and the National Space Biomedical Research Institute (NSBRI) funded researchers by developing computational models of exercising with these new advanced exercise device concepts
Developments in applying aerospace medical technology to the design and production of medical equipment and instrumentation are reported. Projects described include intercranial pressure transducers, leg negative pressure devices, a synthetic speech prosthesis for victims of cerebral palsy, and a Doppler blood flow instrument. Commercialization activities for disseminating and utilizing NASA technology, and new biomedical problem areas are discussed.
Automatic cytogenetic analysis system with digital computer, scanning device, and microscope for mitotic cell detection and classification
The purpose of this study was to evaluate and compare microcalcification detectability of two commercial full-field digital mammography (DM) systems. The first unit was a flat panel based DM system (FFDM) which employed an anti-scatter grid method to reject scatter, and the second unit was a charge-coupled device-based DM system (SSDM) which used scanning slot imaging geometry to reduce scatter radiation. Both systems have comparable scatter-to-primary ratios. In this study, 125-160 and 200-250 {mu}m calcium carbonate grains were used to simulate microcalcifications and imaged by both DM systems. The calcium carbonate grains were overlapped with a 5-cm-thick 50% adipose/50% glandular simulated breast tissue slab and an anthropomorphic breast phantom (RMI 165, Gammex) for imaging at two different mean glandular dose levels: 0.87 and 1.74 mGy. A reading study was conducted with seven board certified mammographers with images displayed on review workstations. A five-point confidence level rating was used to score each detection task. Receiver operating characteristic (ROC) analysis was performed and the area under the ROC curve (A{sub z}) was used to quantify and compare the performances of these two systems. The results showed that with the simulated breast tissue slab (uniform background), the SSDM system resulted in higher A{sub z}'s than the FFDM system at both MGD levels with the difference statistically significant at 0.87 mGy only. With the anthropomorphic breast phantom (tissue structure background), the SSDM system performed better than the FFDM system at 0.87 mGy but worse at 1.74 mGy. However, the differences were not found to be statistically significant.
Purpose: To evaluate the task specific imaging performance of a new 25µm pixel pitch, 1000µm thick amorphous selenium direct detection system with CMOS readout for typical angiographic exposure parameters using the relative object detectability (ROD) metric. Methods: The ROD metric uses a simulated object function weighted at each spatial frequency by the detectors’ detective quantum efficiency (DQE), which is an intrinsic performance metric. For this study, the simulated objects were aluminum spheres of varying diameter (0.05–0.6mm). The weighted object function is then integrated over the full range of detectable frequencies inherent to each detector, and a ratio is taken of the resulting value for two detectors. The DQE for the 25µm detector was obtained from a simulation of a proposed a-Se detector using an exposure of 200µR for a 50keV x-ray beam. This a-Se detector was compared to two microangiographic fluoroscope (MAF) detectors [the MAF-CCD with pixel size of 35µm and Nyquist frequency of 14.2 cycles/mm and the MAF-CMOS with pixel size of 75µm and Nyquist frequency of 6.6 cycles/mm] and a standard flat-panel detector (FPD with pixel size of 194µm and Nyquist frequency of 2.5cycles/mm). Results: ROD calculations indicated vastly superior performance by the a-Se detector in imaging small aluminum spheres. For the 50µm diameter sphere, the ROD values for the a-Se detector compared to the MAF-CCD, the MAF-CMOS, and the FPD were 7.3, 9.3 and 58, respectively. Detector performance in the low frequency regime was dictated by each detector’s DQE(0) value. Conclusion: The a-Se with CMOS readout is unique and appears to have distinctive advantages of incomparable high resolution, low noise, no readout lag, and expandable design. The a-Se direct detection system will be a powerful imaging tool in angiography, with potential break-through applications in diagnosis and treatment of neuro-vascular disease. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.
Purpose: This work investigates the energy response and dose-response curve determinations for XR-QA2 radiochromic film dosimetry system used for synchrotron radiation work and for quality assurance in diagnostic radiology, in the range of effective energies 18–46.5 keV. Methods: Pieces of XR-QA2 films were irradiated, in a plane transverse to the beam axis, with a monochromatic beam of energy in the range 18–40 keV at the ELETTRA synchrotron radiation facility (Trieste, Italy) and with a polychromatic beam from a laboratory x-ray tube operated at 80, 100, and 120 kV. The film calibration curve was expressed as air kerma (measured free-in-air with an ionization chamber) versus the net optical reflectance change (netΔR) derived from the red channel of the RGB scanned film image. Four functional relationships (rational, linear exponential, power, and logarithm) were tested to evaluate the best curve for fitting the calibration data. The adequacy of the various fitting functions was tested by using the uncertainty analysis and by assessing the average of the absolute air kerma error calculated as the difference between calculated and delivered air kerma. The sensitivity of the film was evaluated as the ratio of the change in net reflectance to the corresponding air kerma. Results: The sensitivity of XR-QA2 films increased in the energy range 18–39 keV, with a maximum variation of about 170%, and decreased in the energy range 38–46.5 keV. The present results confirmed and extended previous findings by this and other groups, as regards the dose response of the radiochromic film XR-QA2 to monochromatic and polychromatic x-ray beams, respectively. Conclusions: The XR-QA2 radiochromic film response showed a strong dependence on beam energy for both monochromatic and polychromatic beams in the range of half value layer values from 0.55 to 6.1 mm Al and corresponding effective energies from 18 to 46.5 keV. In this range, the film response varied by 170%, from a minimum sensitivity of 0.0127 to a maximum sensitivity of 0.0219 at 10 mGy air kerma in air. The more suitable function for air kerma calibration of the XR-QA2 radiochromic film was the power function. A significant batch-to-batch variation, up to 55%, in film response at 120 kV (46.5 keV effective energy) was observed in comparison with published data.
No abstract prepared.
Non-destructive optical-based spectroscopic methods are needed for analyzing “real world” devices that consist of thin polymer waveguide films. Many applications (e.g., sensors, microelectronics, optics, and biomedical applications, etc.) utilize thin polymer waveguide films, and non-destructive characterization methods based on Fourier transform (FT)-plasmon waveguide spectroscopy (PWR) and scanning angle (SA) Raman spectroscopy are used to extract optical, physical, and chemical properties simultaneously. The FT-PWR method measures reflected light at polymer waveguide interface as both the incident frequency (wavelength) and incident angle are scanned. This method uses p- and s-polarized light to simultaneously extract the polymer waveguide thickness and apparent anisotropic indices of refraction. Polystyrene waveguide films ranging from 360 to 800 nm are used to demonstrate the method and it has an average 0.4% relative error when compared to profilometry and atomic force microscopy measurements. SA Raman spectroscopy is used to measure mixed waveguide polymer films consisting of polystyrene-block-poly(methyl methacrylate) and homopolymer poly(methyl methacrylate) (PS-b-PMMA:PMMA), and poly(2-vinylnapthalene)-block-poly(methyl methacrylate) (P2VN-b-PMMA). PMMA homopolymer is added to the PS-b-PMMA solutions to vary the chemical composition. The chemical composition of each mixed film is quantified (SA Raman peak amplitude ratios) and averaged over all incident angles and is termed the Raman amplitude ratio (rps). This parameter is used to calculate the refractive index of each mixed waveguide polymer film. The refractive index is an input parameter for sum square electric field (SSEF) calculations, which are used to model SA Raman spectra as a function of incident angle to extract the film thickness. The mixed polymer waveguide film thicknesses ranged from 495 to 971 nm, and the SA Raman spectroscopy method has an average 5% difference between the values determined by profilometry. The SA Raman spectroscopy method developed for mixed polymer waveguide films is used to measure the chemical composition and extract interface locations in bilayer and trilayer films consisting of PMMA/PS or PMMA/PS/PMMA, respectively. The rps value is averaged over angle ranges corresponding to waveguide mode 0 and waveguide mode 1 for the bilayer and trilayer films, respectively. Six multilayer films are analyzed and their total thicknesses range from 330 to 1260 nm. Iterative SSEF calculations are used to model the SA Raman spectra as a function of incident angle, and the best fit to the experimental data is used to extract the total thickness and interface location(s). The method has an axial spatial resolution of 7 to 80 nm and provides comparable values to films measured by profilometry with an average 8% and 7% difference for the bilayer and trilayer films, respectively.
Lower body negative pressure testing in cardiac patients has been completed as well as the design and construction of a new leg negative unit for evaluating heart patients. This technology is based on NASA research, using vacuum chambers to stress the cardiovascular system during space flight. Additional laboratory tests of an intracranial pressure transducer, have been conducted. Three new biomedical problems to which NASA technology is applicable are also identified. These are: a communication device for the speech impaired, the NASA development liquid-cooled garment, and miniature force transducers for heart research.