Multi-Scale Multi-Dimensional Model for Better Cell Design and Management (Presentation)
Describes NREL's R&D to develop a multi-scale model to assist in designing better, more reliable lithium-ion battery cells for advanced vehicles.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Describes NREL's R&D to develop a multi-scale model to assist in designing better, more reliable lithium-ion battery cells for advanced vehicles.
The developed model used is to provide a better understanding and help answer engineering questions about improving the design, operational strategy, management, and safety of cells.
I am going to talk about the need for better materials for radiation detectors. I believe that government investment in this area can enable transformational technology change that could impact domestic nuclear security and also national nuclear security in some very positive and powerful ways. I'm not going to give you a lecture on how radiation detectors work, but I am going to tell you a bit about today's off-the-shelf technology and why it is not sufficient, what we need, and what security benefit you could get from improvements. I think we're at a critical point in time for some very impactful investments. In particular I'm going to focus on the use of gamma-ray radiation detectors at ports of entry. Not long before DHS was formed, Congress decreed that counter measures against the delivery of radiological and nuclear threats would be put in place at US ports of entry, under the authority of US Customs (later Customs and Border Protection in DHS). This included the screening of all cars and trucks passing through a port of entry. Existing off-the-shelf radiation detectors had to be selected for this purpose. Plans were made to make the most of the available technologies, but there are some inherent limitations of these detectors, plus the operational setting can bring out other limitations.
This document was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, usefulness, or any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, re commendation, or favoring by the United States government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof.
This fact sheet is an overview of the Department of Energy's Building Technologies program.
The Wisconsin Energy Efficiency (WE2) Program delivered residential and commercial programming for the City of Milwaukee (Me2) and the City of Madison (Green Madison) as well as commercial only programming for the City of Racine (Re2). Direct incentives and loan products for homeowners and business owners were offered, with the goal to achieve at least 15 percent in energy savings. At the time of this report, there were more than 2,000 residential energy efficiency upgrades completed and more than 300 commercial energy efficiency upgrades completed. The average energy savings for the WE2 Program’s portfolio of residential and commercial projects exceeds 15 percent and is closer to 30 percent energy savings. Combined energy savings of both residential and commercial activities were: 20,937,369 kWh; 1,018,907 Therms; and 31,655 gallons of heating oil; or at least 332,788 MMBTUs; or at least $\$3,444,828$ in estimated energy costs saved. Conservative economic impact estimates include the employment of more than 100 residential auditors and contractors, more than 90 commercial contractors, and more than $\$41$ million in total project costs expended in the targeted communities.
Explore the source record for details and available documents.
This brochure addresses gaps in actionable knowledge that can help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. This brochure should be used to make these decisions so systems can operate more energy efficiently; upfront capital costs will also decrease. This information can also be used to drive changes in negotiations about PPL energy demands. It should enable brokers and tenants to agree about lower PPL capacities. Owner-occupied buildings will also benefit. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems.
Plug loads account for approximately 30% of commercial whole-building energy use, and this percentage is growing. That means the United States spends about $60 billion per year on energy to keep our devices running. About 10% of this is attributed to computing resources, which includes both traditional laptop and desktop computers, as well as data centers that can host virtual machines (VMs) and enable teleworking trends. Teleworking and more flexible work environments are becoming increasingly popular options, and many business and building owners wonder whether hosting VMs on data center servers has the potential to save energy. To answer this question, researchers at the National Renewable Energy Laboratory (NREL) conducted a study comparing energy and usability of remote VMs (accessed through zero-client devices) with traditional laptop computers. The findings were published in the Journal of Sustainable Cities and Society in 2017.
Satellite remote sensing provides unmatched spatiotemporal information on vegetation gross primary productivity (GPP). Yet understanding of the relationship between GPP and remote sensing observations and how it changes with factors such as scale, biophysical constraint, and vegetation type remains limited. This knowledge gap is especially apparent for dryland ecosystems, which have characteristic high spatiotemporal variability and are under–represented by long–term field measurements. Here we utilize an eddy covariance (EC) data synthesis for southwestern North America in an assessment of how accurately satellite–derived vegetation proxies capture seasonal to interannual GPP dynamics across dryland gradients. We evaluate the enhanced vegetation index, solar–induced fluorescence (SIF), and the photochemical reflectivity index. We find evidence that SIF is more accurately capturing seasonal GPP dynamics particularly for evergreen–dominated EC sites and more accurately estimating the full magnitude of interannual GPP dynamics for all dryland EC sites. Furthermore, these results suggest that incorporation of SIF could significantly improve satellite–based GPP estimates.
Abstract Deficiencies in the parameterizations of convection used in global climate models often lead to a distorted representation of the simulated rainfall intensity distribution (i.e., too much rainfall from weak rain rates). While encouraging improvements in high percentile rainfall intensity have been found as the horizontal resolution of the Community Atmosphere Model is increased to ∼25 km, we demonstrate no corresponding improvement in the moderate rain rates that generate the majority of accumulated rainfall. Using a statistical framework designed to emphasize links between precipitation intensity and accumulated rainfall beyond just the frequency distribution, we show that CAM cannot realistically simulate moderate rain rates, and cannot capture their intensification with climate change, even as resolution is increased. However, by separating the parameterized convective and large‐scale resolved contributions to total rainfall, we find that the intensity, geographic pattern, and climate change response of CAM's large‐scale rain rates are more consistent with observations (TRMM 3B42), superparameterization, and theoretical expectations, despite issues with parameterized convection. Increasing CAM's horizontal resolution does improve the representation of total rainfall intensity, but not due to changes in the intensity of large‐scale rain rates, which are surprisingly insensitive to horizontal resolution. Rather, improvements occur through an increase in the relative contribution of the large‐scale component to the total amount of accumulated rainfall. Analysis of sensitivities to convective timescale and entrainment rate confirm the importance of these parameters in the possible development of scale‐aware parameterizations, but also reveal unrecognized trade‐offs from the entanglement of precipitation frequency and total amount.
Abstract not provided
There has been increased interest in the design and applications of small polyaromatic molecules for energy conversion and storage, organic transistors and OLEDs, and other emerging areas of modern technology.[1] In particular, functionalized polycyclic aromatic hydrocarbons (PAHs) were shown to demonstrate excellent electrical mobilities, in organic thin-film transistors, in some cases even under ambient conditions.[2] It has been suggested that air stability of such organic materials is correlated with their electronic properties, and more specifically, with a high electron affinity.[3] Until recently, geodesic PAHs, such as corannulene[4] or sumanene[5] and their numerous derivatives have not been seriously considered for optoelectronic applications because (i) they typically possess very low electron affinities (e.g., EA(C20H10) = 0.5(1) eV),[6] and (ii) laborious multistep syntheses with moderate-to-low yields made them practically unavailable for such studies.[7] Although the low availability of sumanene remains unchanged, significant progress has been made lately in the large-scale synthesis of corannulene.[8] Furthermore, our recent work demonstrated that functionalization of corannulene molecule with electron withdrawing groups (EWGs) results in drastic enhancement of its electron acceptor properties.[9] In particular, for trifluoromethylated derivative C20H5(CF3)5, a 950 mV positive shift in the reduction potential relative to the parent C20H10 was measured. We also predicted that other EWGs, including halogen atoms or cyanide group, could be used to enhance electron affinity of corannulene. Nearly linear correlation between the number of EWGs and the electron affinity (reduction potential) of the corresponding EWG-substituted corannulene molecules that was demonstrated by our DFT calculations, and, more recently, confirmed for C20H10-x(CF3)x=2,3,[10] provides a good tool for design of the molecules with desired electronic properties. Here, we report the first synthesis, structure, and electronic properties (in solution and in the gas phase) of the derivative of corannulene, which has a higher electron affinity (EA) than a well-studied acceptor fullerene C60
Explore the source record for details and available documents.
Abstract Many operational analyses of wind power plants require a statistical relationship, which can be called the wind plant power curve, to be developed between wind plant energy production and concurrent atmospheric variables. Currently, a univariate linear regression at monthly resolution is the industry standard for post‐construction yield assessments. Here, we evaluate the benefits in augmenting this conventional approach by testing alternative regressions performed with multiple inputs, at a finer time resolution, and using nonlinear machine‐learning algorithms. We utilize the National Renewable Energy Laboratory's open‐source software package OpenOA to assess wind plant power curves for 10 wind plants. When a univariate generalized additive model at daily or hourly resolution is used, regression uncertainty is reduced, in absolute terms, by up to 1.0 % and 1.2 % (corresponding to a −59 % and −80 % relative change), respectively, compared to a univariate linear regression at monthly resolution; also, a more accurate assessment of the mean long‐term wind plant production is achieved. Additional input variables also reduce the regression uncertainty: when temperature is added as an input to the conventional monthly linear regression, the operational analysis uncertainty connected to regression is reduced, in absolute terms, by up to 0.5 % (−43 % relative change) for wind power plants with strong seasonal variability. Adding input variables to the machine‐learning model at daily resolution can further reduce regression uncertainty, with up to a −10 % relative change. Based on these results, we conclude that a multivariate nonlinear regression at daily or hourly resolution should be recommended for assessing wind plant power curves.
This paper provides a global overview of the design, implementation, and evolution of building energy codes. Reflecting alternative policy goals, building energy codes differ significantly across the United States, the European Union, and China. This review uncovers numerous innovative practices including greenhouse gas emissions caps per square meter of building space, energy performance certificates with retrofit recommendations, and inclusion of renewable energy to achieve “nearly zero-energy buildings”. These innovations motivated an assessment of an aggressive commercial building code applied to all US states, requiring both new construction and buildings with major modifications to comply with the latest version of the ASHRAE 90.1 Standards. Using the National Energy Modeling System (NEMS), we estimate that by 2035, such building codes in the United States could reduce energy for space heating, cooling, water heating and lighting in commercial buildings by 16%, 15%, 20% and 5%, respectively. Impacts on different fuels and building types, energy rates and bills as well as pollution emission reductions are also examined.
Abstract not provided.