Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arterial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Development of a flow feedback pulse duplicator system with rhesus monkey arterial input impedance characteristics

An in vitro pulsatile pump flow system that is capable of producing physiologic pressures and flows in a mock circulatory system tuned to reproduce the first nine harmonics of the input impedance of a rhesus monkey was developed and tested. The system was created as a research tool for evaluating cardiovascular function and for the design, testing, and evaluation of electrical-mechanical cardiovascular models and chronically implanted sensors. The system possesses a computerized user interface for controlling a linear displacement pulsatile pump in a controlled flow loop format to emulate in vivo cardiovascular characteristics. Evaluation of the pump system consisted of comparing its aortic pressure and flow profiles with in vivo rhesus hemodynamic waveforms in the time and frequency domains. Comparison of aortic pressure and flow data between the pump system and in vivo data showed good agreement in the time and frequency domains, however, the pump system produced a larger pulse pressure. The pump system can be used for comparing cardiovascular parameters with predicted cardiovascular model values and for evaluating such items as vascular grafts, heart valves, biomaterials, and sensors. This article describes the development and evaluation of this feedback controlled cardiovascular dynamics simulation modeling system.

Non-NASA Center↗

System for the diagnosis and monitoring of coronary artery disease, acute coronary syndromes, cardiomyopathy and other cardiac conditions

Cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed and stored in a useful form using a computer. The computer monitor displays various useful information, and in particular graphically displays various permutations of reduced amplitude zones and kurtosis that increase the rapidity and accuracy of cardiac diagnoses. New criteria for reduced amplitude zones are defined that enhance the sensitivity and specificity for detecting cardiac abnormalities.

Schlegel, Todd T.↗

Effects of Spaceflight on Venous and Arterial Compliance

The visual impairment and intracranial pressure (VIIP) syndrome is a spaceflight-associated medical condition consisting of a constellation of symptoms affecting less than 70% of American astronauts who have flown International Space Station (ISS) missions. VIIP is defined primarily by visual acuity deficits and anatomical changes to eye structures and is hypothesized to be related to elevated intracranial pressure secondary to spaceflight-induced cephalad fluid shifts, although other space flight factors (e.g., diet, environmental factors) may contribute. Loss of visual acuity could be a significant threat to crew health and performance during and after an exploration mission and may have implications for years postflight.

Platts, S. H.↗

Effects of Spaceflight on Venous and Arterial Compliance

The visual impairment and intracranial pressure (VIIP) syndrome is a spaceflight-associated set of symptoms affecting more than 50% of American astronauts who have flown International Space Station (ISS) missions. VIIP is defined primarily by visual acuity deficits and anatomical changes to eye structures (e.g. optic disc edema, choroidal folds, and globe flattening) and is hypothesized to be related to elevated intracranial pressure secondary to a cephalad fluid shift. However, ocular symptoms have not been replicated in subjects completing prolonged bed rest, a well-accepted spaceflight analog. Altered vascular compliance along with spaceflight factors such as diet, radiation exposure, or environmental factors may cause alterations in the cardiovascular system that contribute to the manifestation of ocular changes. Loss of visual acuity could be a significant threat to crew health and performance during and after an exploration mission and may have implications for years post-flight. The overall objective of this project is to determine if spaceflight alters vascular compliance and whether such an adaptation is related to the incidence of VIIP. This objective will be met by completing three separate but related projects.

Ribeiro, L. C.↗

Effects of Long Duration Spaceflight on Venous and Arterial Compliance: Bed Rest

The primary objective was to determine whether a high sodium diet during bed rest induced alterations in vascular compliance and was related to the incidence of VIIP. Ocular structural and functional measures and vascular ultrasound of the head and neck were acquired in bed rest subjects completing 10-14 days in 6deg head-down tilt.

Ribeiro, L. Christine↗

Ergot alkaloid consumption alters serotonin receptor-induced vasoactivity in ovine umbilical vasculature

Consumption of ergot alkaloids during the second half of gestation has been shown to decrease umbilical artery vasoactivity resulting in decreased birth weights. Negative vascular effects of ergot alkaloids are mediated predominantly through serotonergic and adrenergic receptors in other tissues. Vasoactivity of serotonin (5-HT) receptors 5-HT 2A and 5-HT 1B/1D in umbilical artery and vein from ewes receiving endophyte-infected seed (E + 1.77 mg ergovaline/hd/d) or a control total mixed ration (CON; 0 mg ergovaline/hd/d) tall fescue seed at d-110 and d-133 of gestation was evaluated. Gravid reproduction tracts were collected from ewes. Two-mm sections of umbilical artery and vein were exposed to increasing concentrations of a 5-HT 1B/1D agonist and 5-HT 2A agonist. The 5-HT 1B/1D agonist did not stimulate a contractile response in artery or vein or either gestation time point. 5-HT 2A agonist caused large responses in artery with greatest occurring at d-110 and decreasing in magnitude as days of gestation increased ( p < 0.05). On d-110 and 133 of gestation, arteries from CON ewes had greater contractile response than arteries collected from E+ ewes ( p < 0.05). Veins responded to increasing concentrations of the 5-HT 2A agonist. Maximal d-110 vein response was greater than d-133 when exposed to 5-HT 2A agonist ( p < 0.05). Unlike the artery, veins from E+ ewes had greater d-133 contractile response than CON ( p < 0.05). Vascular contractions of umbilical artery and vein are induced by 5-HT 2A receptor activity and not 5-HT 1B/1D . Umbilical artery 5-HT 2A receptor activity was more sensitive to seed treatment and could be responsible for ergot alkaloid-induced intra-uterine growth restriction.

Toxicology↗

Valsalva maneuver: Insights into baroreflex modulation of human sympathetic activity

Valsalva's maneuver, voluntary forced expiration against a closed glottis, is a well-characterized research tool, used to assess the integrity of human autonomic cardiovascular control. Valsalva straining provokes a stereotyped succession of alternating positive and negative arterial pressure and heart rate changes mediated in part by arterial baroreceptors. Arterial pressure changes result primarily from fluctuating levels of venous return to the heart and changes of sympathetic nerve activity. Muscle sympathetic activity was measured directly in nine volunteers to explore quantitatively the relation between arterial pressure and human sympathetic outflow during pressure transients provoked by controlled graded Valsalva maneuvers. Our results underscore several properties of sympathetic regulation during Valsalva straining. First, muscle sympathetic nerve activity changes as a mirror image of changes in arterial pressure. Second, the magnitude of sympathetic augmentation during Valsalva straining predicts phase 4 arterial pressure elevations. Third, post-Valsalva sympathetic inhibition persists beyond the return of arterial and right atrial pressures to baseline levels which reflects an alteration of the normal relation between arterial pressure and muscle sympathetic activity. Therefore, Valsalva straining may have some utility for investigating changes of reflex control of sympathetic activity after space flight; however, measurement of beat-to-beat arterial pressure is essential for this use. The utility of this technique in microgravity can not be determined from these data. Further investigations are necessary to determine whether these relations are affected by the expansion of intrathoracic blood volume associated with microgravity.

Smith, Michael L.↗

Transfer function analysis of dynamic cerebral autoregulation in humans

To test the hypothesis that spontaneous changes in cerebral blood flow are primarily induced by changes in arterial pressure and that cerebral autoregulation is a frequency-dependent phenomenon, we measured mean arterial pressure in the finger and mean blood flow velocity in the middle cerebral artery (VMCA) during supine rest and acute hypotension induced by thigh cuff deflation in 10 healthy subjects. Transfer function gain, phase, and coherence function between changes in arterial pressure and VMCA were estimated using the Welch method. The impulse response function, calculated as the inverse Fourier transform of this transfer function, enabled the calculation of transient changes in VMCA during acute hypotension, which was compared with the directly measured change in VMCA during thigh cuff deflation. Beat-to-beat changes in VMCA occurred simultaneously with changes in arterial pressure, and the autospectrum of VMCA showed characteristics similar to arterial pressure. Transfer gain increased substantially with increasing frequency from 0.07 to 0.20 Hz in association with a gradual decrease in phase. The coherence function was > 0.5 in the frequency range of 0.07-0.30 Hz and < 0.5 at < 0.07 Hz. Furthermore, the predicted change in VMCA was similar to the measured VMCA during thigh cuff deflation. These data suggest that spontaneous changes in VMCA that occur at the frequency range of 0.07-0.30 Hz are related strongly to changes in arterial pressure and, furthermore, that short-term regulation of cerebral blood flow in response to changes in arterial pressure can be modeled by a transfer function with the quality of a high-pass filter in the frequency range of 0.07-0.30 Hz.

NASA Discipline Cardiopulmonary↗

'Non-hypotensive' hypovolaemia reduces ascending aortic dimensions in humans

1. The notion that small, 'non-hypotensive' reductions of effective blood volume alter neither arterial pressure nor arterial baroreceptor activity is pervasive in the experimental literature. We tested two hypotheses: (a) that minute arterial pressure and cardiac autonomic outflow changes during hypovolaemia induced by lower body suction in humans are masked by alterations in breathing, and (b) that evidence for arterial baroreflex engagement might be obtained from measurements of thoracic aorta dimensions. 2. In two studies, responses to graded lower body suction at 0 (control), 5, 10, 15, 20 and 40 mmHg were examined in twelve and ten healthy young men, respectively. In the first, arterial pressure (photoplethysmograph), R-R interval, and respiratory sinus arrhythmia amplitude (complex demodulation) were measured during uncontrolled and controlled breathing (constant breathing frequency and tidal volume). In the second, cross-sectional areas of the ascending thoracic aorta were calculated from nuclear magnetic resonance images. 3. Lower body suction with controlled breathing resulted in an increased arterial pulse pressure at mild levels (5-20 mmHg; ANOVA, P < 0.05) and a decreased arterial pulse pressure at moderate levels (40 mmHg; ANOVA, P < 0.05). Both R-R intervals and respiratory sinus arrhythmia were negatively related to lower body suction level, whether group averages (general linear regression, r > 0.92) or individual subjects (orthogonal polynomials, 12 of 12 subjects) were assessed. 4. Aortic pulse area decreased progressively and significantly during mild lower body suction, with 47% of the total decline occurring by 5 mmHg. 5. These results suggest that small reductions of effective blood volume reduce aortic baroreceptive areas and trigger haemodynamic adjustments which are so efficient that alterations in arterial pressure escape detection by conventional means.

NASA Discipline Cardiopulmonary↗

Human autonomic rhythms: vagal cardiac mechanisms in tetraplegic subjects

1. We studied eight young men (age range: 20-37 years) with chronic, clinically complete high cervical spinal cord injuries and ten age-matched healthy men to determine how interruption of connections between the central nervous system and spinal sympathetic motoneurones affects autonomic cardiovascular control. 2. Baseline diastolic pressures and R-R intervals (heart periods) were similar in the two groups. Slopes of R-R interval responses to brief neck pressure changes were significantly lower in tetraplegic than in healthy subjects, but slopes of R-R interval responses to steady-state arterial pressure reductions and increases were comparable. Plasma noradrenaline levels did not change significantly during steady-state arterial pressure reductions in tetraplegic patients, but rose sharply in healthy subjects. The range of arterial pressure and R-R interval responses to vasoactive drugs (nitroprusside and phenylephrine) was significantly greater in tetraplegic than healthy subjects. 3. Resting R-R interval spectral power at respiratory and low frequencies was similar in the two groups. During infusions of vasoactive drugs, low-frequency R-R interval spectral power was directly proportional to arterial pressure in tetraplegic patients, but was unrelated to arterial pressure in healthy subjects. Vagolytic doses of atropine nearly abolished both low- and respiratory-frequency R-R interval spectral power in both groups. 4. Our conclusions are as follows. First, since tetraplegic patients have significant levels of low-frequency arterial pressure and R-R interval spectral power, human Mayer arterial pressure waves may result from mechanisms that do not involve stimulation of spinal sympathetic motoneurones by brainstem neurones. Second, since in tetraplegic patients, low-frequency R-R interval spectral power is proportional to arterial pressure, it is likely to be mediated by a baroreflex mechanism. Third, since low-frequency R-R interval rhythms were nearly abolished by atropine in both tetraplegic and healthy subjects, these rhythms reflect in an important way rhythmic firing of vagal cardiac motoneurones.

Non-NASA Center↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.

Lee, Yong Jin↗

Defining the Relationship between Biomarkers of Oxidative and Inflammatory Stress and the Risk for Atherosclerosis in Astronauts during and after Long-duration Spaceflight

Future human space travel will consist primarily of long-duration missions onboard the International Space Station (ISS) or exploration-class missions to Mars, its moons, or nearby asteroids. These missions will expose astronauts to increased risk of oxidative and inflammatory damage from a variety of sources, including radiation, psychological stress, reduced physical activity, diminished nutritional status, and hyperoxic exposure during extravehicular activity. Evidence exists that increased oxidative damage and inflammation can accelerate the development of atherosclerosis. PURPOSE The purpose of this investigation is to determine whether biomarkers of oxidative and inflammatory stress are elevated during and after long-duration spaceflight and investigate if a relation exists between levels of these biomarkers and structural and functional indices of atherosclerotic risk measured in the carotid and brachial arteries. This is the first study to propose assessing atherosclerotic risk using biochemical, structural, and functional measures before, during, and immediately after spaceflight, and structural and functional measures for up to 5 years after landing. METHODS We will study 12 astronauts before, during, and up to 5 years after long-duration ISS missions. A panel of biomarkers of oxidative and inflammatory stress will be measured twice before flight, early (flight days 15 and 60) and late (2 weeks before landing) during the mission, and early in the postflight recovery phase (approx 3 days after landing). Arterial structure and vascular compliance will be measured at the same times and also at 1, 3, and 5 years after landing (surveillance). Arterial function will be measured using the same preflight, postflight, and surveillance schedule as arterial structure and vascular compliance measures, but will not be measured inflight. Biomarkers, some of which we have previously shown to be elevated with spaceflight, will be measured in venous blood samples and 24-h (in-flight) and 48-h (pre- and post-flight) urine pools. Arterial structure will be assessed from measures of carotid intima-media thickness, which have been shown to be better indicators of atherosclerotic than the Framingham Risk Score. Arterial function will be assessed using brachial flow-mediated dilation, a well-validated measure used to assess endothelium-dependent vasodilation and is a sensitive predictor of atherosclerotic risk. Arterial pulse pressure measured in the brachial artery and stroke volume measured from cardiac ultrasound will be used to assess hemodynamic status, cardiac function, and systemic vascular compliance. Three astronauts are actively participating in the preflight data collection and training activities. One astronaut has completed all preflight activities and will participate in the first in-flight data collection sessions by the end of 2013. The first post-flight data collection sessions will occur in the spring of 2014. EXPECTED RESULTS We hypothesize that biomarkers of oxidative and inflammatory stress will increased with spaceflight and will correlate with increased carotid intima-media thickness during and after flight and with decreased flow-mediated dilation after the mission. Furthermore, we hypothesize that measures of oxidative stress will return to baseline after flight, but biomarkers of inflammatory stress and vascular indices of atherosclerotic risk will remain elevated.

Lee, Stuart M. C.↗

Acute Stent-Induced Endothelial Denudation: Biomechanical Predictors of Vascular Injury

Recent concern for local drug delivery and withdrawal of the first Food and Drug Administration-approved bioresorbable scaffold emphasizes the need to optimize the relationships between stent design and drug release with imposed arterial injury and observed pharmacodynamics. In this study, we examine the hypothesis that vascular injury is predictable from stent design and that the expanding force of stent deployment results in increased circumferential stress in the arterial tissue, which may explain acute injury poststent deployment. Using both numerical simulations and ex vivo experiments on three different stent designs (slotted tube, corrugated ring, and delta wing), arterial injury due to device deployment was examined. Furthermore, using numerical simulations, the consequence of changing stent strut radial thickness on arterial wall shear stress and arterial circumferential stress distributions was examined. Regions with predicted arterial circumferential stress exceeding a threshold of 49.5 kPa compared favorably with observed ex vivo endothelial denudation for the three considered stent designs. In addition, increasing strut thickness was predicted to result in more areas of denudation and larger areas exposed to low wall shear stress. We conclude that the acute arterial injury, observed immediately following stent expansion, is caused by high circumferential hoop stresses in the interstrut region, and denuded area profiles are dependent on unit cell geometric features. Such findings when coupled with where drugs move might explain the drug–device interactions.

Conway, Claire↗