Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “aperture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A uniformly redundant imaging array of penumbral apertures coupled with a heuristic reconstruction for hard x-ray and neutron imaging

A coded imaging and decoding (image reconstruction) scheme was developed for diagnosing a hot and dense region emitting hard x-rays and neutrons in laser-fusion plasmas. Because the imager was a uniformly redundant array of penumbral aperture (URPA) arranged in an M-matrix, URPA leads to N times (N: the total number of apertures) enhancement of signal intensity in comparison with a single penumbral aperture. A recorded penumbral image was reconstructed by a computer-based heuristic method to reduce artifacts caused by noises contained in a penumbral image. Applicability of this technique was investigated by imaging x-rays emitted from laser-produced plasmas, demonstrating a spatial resolution of 16 {mu}m. Under the present conditions, the spatial resolution was determined dominantly by a detector resolution (10.5 {mu}m) and a signal-to-noise ratio of the obtained penumbral image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational study of ion beam extraction phenomena through multiple apertures

The process of ion extraction through multiple apertures is investigated using a two-dimensional particle-in-cell code. We consider apertures with a fixed diameter with a hydrogen plasma background, and the trajectories of electrons, H{sup +} and H{sub 2}{sup +} ions in the self-consistently calculated electric field are traced. The focus of this work is the fundamental physics of the ion extraction, and not particular to a specific device. The computed convergence and divergence of the extracted ion beam are analyzed. We find that the extracted ion flux reaching the extraction electrode is non-uniform, and the peak flux positions change according to operational parameters, and do not necessarily match the positions of the apertures in the y-direction. The profile of the ion flux reaching the electrode is mainly affected by the bias voltage and the distance between grid wall and extraction electrode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral light separator based on deep-subwavelength resonant apertures in a metallic film

We propose to funnel, select, and collect light spectrally by exploiting the unique properties of deep-subwavelength resonant apertures in a metallic film. In our approach, each aperture has an electromagnetic cross section that is much larger than its physical size while the frequency of the collected light is controlled by its height through the Fabry-Pérot resonance mechanism. The electromagnetic crosstalk between apertures remains low despite physical separations in the deep-subwavelength range. The resulting device enables an extremely efficient, subwavelength way to decompose light into its spectral components without the loss of photons and spatial coregistration errors. As a specific example, we show a subwavelength-size structure with three deep-subwavelength slits in a metallic film designed to operate in the mid-wave infrared range between 3 and 5.5 μm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthetic aperture microwave imaging with active probing for fusion plasma diagnostics

A Synthetic Aperture Microwave Imaging (SAMI) system has been designed and built to obtain 2-D images at several frequencies from fusion plasmas. SAMI uses a phased array of linearly polarised antennas. The array configuration has been optimised to achieve maximum synthetic aperture beam efficiency. The signals received by antennas are down-converted to the intermediate frequency range and then recorded in a full vector form. Full vector signals allow beam focusing and image reconstruction in both real time and a post-processing mode. SAMI can scan over 16 pre-programmed frequencies in the range of 10-35GHz with a switching time of 300ns. The system operates in 2 different modes simultaneously: both a 'passive' imaging of plasma emission and also an 'active' imaging of the back-scattered signal of the radiation launched by one of the antennas from the same array. This second mode is similar to so-called Doppler backscattering (DBS) reflectometry with 2-D resolution of the propagation velocity of turbulent structures. Both modes of operation show good performance in fusion plasma experiments on Mega Amp Spherical Tokamak (MAST). We have obtained the first ever 2-D images of BXO mode conversion windows. With active probing, first ever turbulence velocity maps have been obtained. We present an overview of the diagnostic and discuss recent results. In contrast to quasi-optical microwave imaging systems SAMI requires neither big aperture viewing ports nor large 2-D detector arrays to achieve the desired imaging resolution. The number of effective 'pixels' of the synthesized image is proportional to the number of receiving antennas squared. Thus only a small number of optimised antennas is sufficient for the majority of applications. Possible implementation of SAMI on ITERand DEMO is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stopping potential and ion beamlet control for micro-resistive patterning through sub-Debye length plasma apertures

Focused multiple ion beamlets from a microwave plasma source is investigated for localized micron-scale modification of substrates in a patterned manner. Plasma electrodes (PE) with an array of through apertures having aperture diameters of the order of plasma Debye length are investigated for generating the beamlets. Extraction through sub-Debye length apertures becomes possible when the PE is kept at floating potential. It is found that the current – voltage characteristics of the extracted beamlets exhibits interesting features such as a space-charge-limited region that has a different behaviour than the conventional Child-Langmuir’s law and an extraction-voltage-limited region that does not undergo saturation but exhibits a Schottky-like behaviour similar to that of a vacuum diode. A switching technique to control the motion of individual beamlets is developed and the stopping potential determined. The beamlets are thereafter used to create localized micro-resistive patterns. The experimental results are compared with simulations and reasonably good agreement is obtained.

36 MATERIALS SCIENCE↗

Development of design technique for vacuum insulation in large size multi-aperture multi-grid accelerator for nuclear fusion

Design techniques for the vacuum insulation have been developed in order to realize a reliable voltage holding capability of multi-aperture multi-grid (MAMuG) accelerators for fusion application. In this method, the nested multi-stage configuration of the MAMuG accelerator can be uniquely designed to satisfy the target voltage within given boundary conditions. The evaluation of the voltage holding capabilities of each acceleration stages was based on the previous experimental results about the area effect and the multi-aperture effect. Since the multi-grid effect was found to be the extension of the area effect by the total facing area this time, the total voltage holding capability of the multi-stage can be estimated from that per single stage by assuming the stage with the highest electric field, the total facing area, and the total apertures. By applying these consideration, the analysis on the 3-stage MAMuG accelerator for JT-60SA agreed well with the past gap-scan experiments with an accuracy of less than 10% variation, which demonstrated the high reliability to design MAMuG accelerators and also multi-stage high voltage bushings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of topologically diverse acoustic vortex beams using a compact metamaterial aperture

Here, we present a class of metamaterial-based acoustic vortex generators which are both geometrically simple and broadly tunable. The aperture overcomes the significant limitations of both active phasing systems and existing passive coded apertures. The metamaterial approach generates topologically diverse acoustic vortex waves motivated by recent advances in leaky wave antennas by wrapping the antenna back upon itself to produce an acoustic vortex wave antenna. We demonstrate both experimentally and analytically that this single analog structure is capable of creating multiple orthogonal orbital angular momentum modes using only a single transducer. The metamaterial design makes the aperture compact, with a diameter nearly equal to the excitation wavelength and can thus be easily integrated into high-density systems. Applications range from acoustic communications for high bit-rate multiplexing to biomedical devices such as microfluidic mixers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Closed laser-beam trajectories in plano-spherical resonators with Gaussian apertures

The closed trajectories of a Gaussian beam in plano-spherical degenerate and nondegenerate resonators with two Gaussian apertures (with two pump regions with the Gaussian distribution of the gain) are described analytically and the existence conditions are found for such trajectories. It was assumed that Gaussian apertures (gain regions) were located in the plane of a flat mirror at equal distances on both sides of the resonator axis and the size of apertures restricted their action by the corresponding half-plane. (beams, resonators)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transmission of evanescent modes through a subwavelength aperture of a cylindrical waveguide. 1. Ideal metal approximation

The transmission of an evanescence electromagnetic wave through the subwavelength aperture of a dielectric cylindrical metal-coated waveguide is studied. In the ideal metal approximation a theoretical approach to the description of the field structure in a nanowaveguide is developed, which takes into account the transformation of the initial wave reflected from the output aperture. The complex reflection coefficient of a supercritical waveguide mode from the subwavelength aperture is calculated. The dependence of the field structure at the waveguide output on the ratio of its radius to the optical wavelength and on the dielectric constants of the waveguide core and the environment is found. The conditions for the appearance of a plasmon resonance in the presence of a medium with the negative dielectric constant in front of the input hole of the waveguide are found. (waveguides)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ANALYTIC APERTURE CALCULATION AND SCALING LAWS FOR RADIO DETECTION OF LUNAR-TARGET ULTRA-HIGH-ENERGY NEUTRINOS

We derive analytic expressions and approximate them in closed form, for the effective detection aperture for Cerenkov radio emission from ultra-high-energy neutrinos striking the Moon. The resulting apertures are in good agreement with recent Monte Carlo simulations and support the conclusion of James and Protheroe that neutrino flux upper limits derived from the GLUE search were too low by an order of magnitude. We also use our analytic expressions to derive scaling laws for the aperture as a function of observational and lunar parameters. We find that at low frequencies downward-directed neutrinos always dominate, but at higher frequencies, the contribution from upward-directed neutrinos becomes increasingly important, especially at lower neutrino energies. Detecting neutrinos from Earth near the Greisen-Zatsepin-Kuz'min regime will likely require radio telescope arrays with extremely large collecting area (A{sub e} approx 10{sup 6} m{sup 2}) and hundreds of hours exposure time. Higher-energy neutrinos are most easily detected using lower frequencies. Lunar surface roughness is a decisive factor for obtaining detections at higher frequencies (nuapprox> 300 MHz) and higher energies (E approx> 10{sup 21} eV).

79 ASTRONOMY AND ASTROPHYSICS↗

Bethe's aperture theory for arrays

Bethe's theory is applied to the optical transmission through an array of apertures in an infinitely thin perfect electric conductor. This method shows that, in the small-aperture limit, the lowest-order TM evanescent mode governs the transmission process, allowing for both 100% transmission at the passband wavelength and zero transmission at the Wood's anomaly. The applicability of this theory to total transmission in other systems is discussed, and a specific example of a single aperture in a transverse screen of a rectangular waveguide is given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electromagnetic transmission resonances for a single annular aperture in a metal plate

We present a theory for the reflection phase and amplitude of the lowest-order TEM mode in an annular aperture at the end of a metal plate. This reflection coefficient determines the frequency and peak width of the Fabry-Perot transmission resonances. The theory assumes that the width of the aperture is subwavelength; however, the annular radius can be quite large, and we show that the theory reproduces the reflection of a linear slit in the limit of infinite radius. Finite-difference time-domain calculations agree well with the theory, in terms of both the transmission resonance frequency values and the extracted reflectivity. The theory presented shows that both the phase and amplitude of reflection can vary substantially with changes in geometry and frequency, and that both are modulated by transverse resonances. This work has implications for filters, near-field aperture probes, sensors, and metamaterials.

74 ATOMIC AND MOLECULAR PHYSICS↗

Aperture-time of oxygen-precursor for minimum silicon incorporation into the interface-layer in atomic layer deposition-grown HfO{sub 2}/Si nanofilms

Hafnium oxide nanofilms were grown with atomic layer deposition on H-terminated Si (001) wafers employing tetrakis dimethyl amino hafnium (TDMA-Hf) and water as precursors. While the number of cycles (30) and the aperture-time for TDMA-Hf (0.08 s) were kept constant, the aperture-time (τ{sub H{sub 2O}}) for the oxidant-agent (H{sub 2}O) was varied from 0 to 0.10 s. The structure of the films was characterized with robust analysis employing angle-resolved x-ray photoelectron spectroscopy. In addition to a ∼1 nm hafnium oxide layer, a hafnium silicate interface layer, also ∼1 nm thick, is formed for τ{sub H{sub 2O}} > 0. The incorporation degree of silicon into the interface layer (i.e., the value of 1 − x in Hf{sub x}Si{sub 1−x}O{sub y}) shows a minimum of 0.32 for τ{sub H{sub 2O}} = 0.04 s. By employing the simultaneous method during peak-fitting analysis, it was possible to clearly resolve the contribution from the silicate and from oxide to the O 1s spectra, allowing for the assessment of the oxygen composition of each layer as a function of oxidant aperture time. The uncertainties of the peak areas and on the thickness and composition of the layers were calculated employing a rigorous approach.

36 MATERIALS SCIENCE↗

MCTP system model based on linear programming optimization of apertures obtained from sequencing patient image data maps

Purpose: The authors present a hybrid direct multileaf collimator (MLC) aperture optimization model exclusively based on sequencing of patient imaging data to be implemented on a Monte Carlo treatment planning system (MC-TPS) to allow the explicit radiation transport simulation of advanced radiotherapy treatments with optimal results in efficient times for clinical practice. Methods: The planning system (called CARMEN) is a full MC-TPS, controlled through aMATLAB interface, which is based on the sequencing of a novel map, called “biophysical” map, which is generated from enhanced image data of patients to achieve a set of segments actually deliverable. In order to reduce the required computation time, the conventional fluence map has been replaced by the biophysical map which is sequenced to provide direct apertures that will later be weighted by means of an optimization algorithm based on linear programming. A ray-casting algorithm throughout the patient CT assembles information about the found structures, the mass thickness crossed, as well as PET values. Data are recorded to generate a biophysical map for each gantry angle. These maps are the input files for a home-made sequencer developed to take into account the interactions of photons and electrons with the MLC. For each linac (Axesse of Elekta and Primus of Siemens) and energy beam studied (6, 9, 12, 15 MeV and 6 MV), phase space files were simulated with the EGSnrc/BEAMnrc code. The dose calculation in patient was carried out with the BEAMDOSE code. This code is a modified version of EGSnrc/DOSXYZnrc able to calculate the beamlet dose in order to combine them with different weights during the optimization process. Results: Three complex radiotherapy treatments were selected to check the reliability of CARMEN in situations where the MC calculation can offer an added value: A head-and-neck case (Case I) with three targets delineated on PET/CT images and a demanding dose-escalation; a partial breast irradiation case (Case II) solved with photon and electron modulated beams (IMRT + MERT); and a prostatic bed case (Case III) with a pronounced concave-shaped PTV by using volumetric modulated arc therapy. In the three cases, the required target prescription doses and constraints on organs at risk were fulfilled in a short enough time to allow routine clinical implementation. The quality assurance protocol followed to check CARMEN system showed a high agreement with the experimental measurements. Conclusions: A Monte Carlo treatment planning model exclusively based on maps performed from patient imaging data has been presented. The sequencing of these maps allows obtaining deliverable apertures which are weighted for modulation under a linear programming formulation. The model is able to solve complex radiotherapy treatments with high accuracy in an efficient computation time.

60 APPLIED LIFE SCIENCES↗

Dose equations for shift-variant CT acquisition modes using variable pitch, tube current, and aperture, and the meaning of their associated CTDI{sub vol}

Purpose: With the increasing clinical use of shift-variant CT protocols involving tube current modulation (TCM), variable pitch or pitch modulation (PM), and variable aperture a(t), the interpretation of the scanner-reported CTDI{sub vol} is called into question. This was addressed for TCM in their previous paper published by Dixon and Boone [Med. Phys. 40, 111920 (14pp.) (2013)] and is extended to PM and concurrent TCM/PM as well as variable aperture in this work. Methods: Rigorous convolution equations are derived to describe the accumulated dose distributions for TCM, PM, and concurrent TCM/PM. A comparison with scanner-reported CTDI{sub vol} formulae clearly identifies the source of their differences with the traditional CTDI{sub vol}. Dose distribution simulations using the convolution are provided for a variety of TCM and PM scenarios including a helical shuttle used for perfusion studies (as well as constant mA)—all having the same scanner-reported CTDI{sub vol}. These new convolution simulations for TCM are validated by comparison with their previous discrete summations. Results: These equations show that PM is equivalent to TCM if the pitch variation p(z) is proportional to 1/i(z), where i(z) is the local tube current. The simulations show that the local dose at z depends only weakly on the local tube current i(z) or local pitch p(z) due to scatter from all other locations along z, and that the “local CTDI{sub vol}(z)” or “CTDI{sub vol} per slice” do not represent a local dose but rather only a relative i(z) or p(z). The CTDI-paradigm does not apply to shift-variant techniques and the scanner-reported CTDI{sub vol} for the same lacks physical significance and relevance. Conclusions: While the traditional CTDI{sub vol} at constant tube current and pitch conveys useful information (the peak dose at the center of the scan length), CTDI{sub vol} for shift-variant techniques (TCM or PM) conveys no useful information about the associated dose distribution it purportedly represents. On the other hand, the total energy absorbed E (“integral dose”) as well as its surrogate DLP remain robust (invariant) with respect to shift-variance, depending only on the total mAs = 〈i〉t{sub 0} accumulated during the total beam-on time t{sub 0} and aperture a, where 〈i〉 is the average current.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-P-40: Dosimetric Characteristics of Field Aperture Margin Design in Stereotactic Body Radiation Therapy (SBRT)

Purpose: To characterize the dosimetric effects of field aperture margin design in Stereotactic Body Radiation Therapy (SBRT). Methods: Three artificial spherical PTVs, with diameter of 10mm, 20mm and 30mm, were created on CT images of a human body thoracic phantom. Seven non-coplanar isocentric fields were used for treatment planning. For each PTV, treatment plans with margins 0mm, 1mm, 2mm and 3mm were planned. Dosimetric comparison among plans was done considering the following parameters: prescribed isodose line for target coverage, maximum dose, mean dose as well as dose spillages of V80, V50, and V20. Results: Corresponding to aperture margins of 0mm, 1mm,2m and 3mm used in the treatment planning, the percentage of isodose line chosen for dose prescription increases from 65% to 93% for 10mm PTV, 70% to 92% for 20mm PTV, and 75% to 92% for 30mm PTV. The maximum dose decrease accordingly from 155.7% to 109.5% for 10mm PTV, 145% to 111.6% for 20mm PTV, 137% to 112.2% for 30mm PTV. The mean dose decrease from 138.% to 104.4% for 10mm PTV, 122.8% to 106.1% for 20mm PTV, 121.3% to 106% for 30mm PTV. Dose spillages (mm3) increase (V80−2.6 to 4.02, V50−4.55 to 9.3, V20–87.86 to 101.71) for 10 mm PTV, (V80−6.78 to 9.89, V50–13.46 to 20.4, V20-119.16 to 219.1) for 20 mm PTV, (V80–22.01 to 28.59, V50–41.56 to 52.66, V20-532.71 to 551.84) for 30 mm PTV. Conclusion: In SBRT treatment planning, tight field aperture margin requires prescribing dose to lower isodose line that leading to higher dose inhomogeneity and higher mean dose to PTV. Loose margin allows prescribing dose to higher isodose line, therefore improves the dose homogeneity. However, it increases dose spillages. Clinician could try different margins according to the PTV size and location of surrounding critical organs to optimize the dose delivered to the patient.

60 APPLIED LIFE SCIENCES↗

Split in phase singularities of an optical vortex by off-axis diffraction through a simple circular aperture

Here, diffraction patterns of an optical vortex through several shaped apertures reveal its topological charge. In this letter, we theoretically and experimentally show that diffraction of a Laguerre Gaussian beam through a circular aperture at an off-axis position can be used to determine the magnitude and sign of the topological charge. To our knowledge, this is the first time that a simple circular aperture has been used to detect orbital angular momentum of an incident optical vortex.

43 PARTICLE ACCELERATORS↗

Comments on Momentum Aperture of 100 GeV/n Au Runs in RHIC

In RHIC 2010 100 GeV/n Au run, the momentum aperture has been an issue in the re-bucketing and the beam intensity lifetime in store. Both Blue and Yellow beams with comparable storage RF voltage and peak current have suffered more beam loss than in Run 2007. In this note, some comments are made for the momentum aperture of the lattices used from the Au runs in 2007, 2008 and 2010. From the wigglings and the beam decays of each lattice, information regarding the machine momentum aperture is presented. Several directions in further improvement are discussed.

43 PARTICLE ACCELERATORS↗