Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “annual assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

JACIE: A Model Partnership

The National Aeronautics and Space Administration (NASA), National Oceanic and Atmospheric Administration (NOAA), the United States Department of Agriculture (USDA), and the United States Geological Survey (USGS), and their associates and partners, are directly responsible for establishing and leading a unique interagency team of scientists and engineers who work together to evaluate and enhance the quality remote sensing data for commercial and government use. This team is called "the Joint Agency Commercial Imagery Evaluation (JACIE) team". The team works together to define, prioritize, assign, and assess civil and commercial image quality and jointly sponsors an annual JACIE Civil Commercial Imagery Evaluation workshop with participation support from the remote sensing calibration and validation science community.

Image Data↗

Meteor Shower Forecasting in Near-Earth Space

NASA’s Meteoroid Environment Office (MEO) produces an annual meteor shower forecast in order to help spacecraft operators assess the risk posed by meteoroid streams. Previously, this forecast focused on the International Space Station and therefore reported meteoroid fluxes and enhancement factors at an orbital altitude of 400 km. This paper presents an updated forecast algorithm that has an improved calculation of the flux enhancement produced by showers and can calculate fluxes at any selected Earth or lunar orbital altitude. Finally, we discuss and generate forecasted fluxes for the 2018 Draconid meteor shower, which is expected to produce meteoroid flux enhancements near the Sun-Earth L1 and L2 Lagrange points but not at Earth.

Althea V Moorhead↗

Seasonal Tidewater Glacier Terminus Oscillations Bias Multi-Decadal Projections of Ice Mass Change

Numerical, process-based simulations of tidewater glacier evolution are necessary to project future sea-level change under various climate scenarios. Previous work has shown that nonlinearities in tidewater glacier and ice stream dynamics can lead to biases in simulated ice mass change in the presence of noisy forcings. Ice sheet modeling projections that are used in the IPCC Assessment Report 6 (AR6) utilize atmospheric and oceanic forcings at annual temporal resolution, omitting any higher frequency forcings. Here, we quantify the effect of seasonal (<1 year) tidewater glacier terminus oscillations on decadal-scale (30 years) mass change. We use an idealized geometry to mimic realistic tidewater glacier geometries and investigate the impact of the magnitude of seasonal oscillations, bed slope at the glacier terminus, and basal friction law. We find that omitting seasonal terminus motion results in biased mass change projections, with up to an 39% underestimate or 25% overestimate of mass loss when seasonality is neglected, depending on bed slope and magnitude of oscillations. The bias is most sensitive to the magnitude of the seasonal terminus oscillations and exhibits very little sensitivity to choice of friction law. Although omitting seasonal terminus motion may bias mass change projections of individual glaciers, further work is needed to investigate the impact on ice sheet mass change projections. In order to achieve this, seasonality in atmospheric and oceanic forcings must be adequately represented and observations of seasonal terminus positions and tidewater glacier thickness changes must be acquired to evaluate numerical models. Note: Zip folder contains all videos listed in the supplemental document and can be downloaded for viewing.

D. Felikson↗

Industrial Assessment Center – integration of education and practice. Final progress report

The goal of the DOE’s Industrial Assessment Center (IAC) program is twofold: first, to help US manufacturing competitiveness by providing assessments and recommendations for small and medium-sized enterprises (SMEs) on energy efficiency, productivity, sustainability and competitiveness – including measuring the impacts of these recommendations on reducing greenhouse gas emissions; and second, to address a growing shortage of engineering professionals with applied energy and manufacturing-related skills by training a diverse cross-section of engineering students through hands-on involvement in these assessments. IUPUI has an IAC, which was established in 2011, in the Department of Mechanical and Energy Engineering, Purdue School of Engineering and Technology, IUPUI. The IAC has won the awards twice. We have built the center that has the expertise and infrastructure for quality energy assessments to manufactures and commercial building owners and aligned our current research and teaching activities to the DOE’ training mission with programs to train the next generation of industrial energy efficiency experts, with theory and hands-on experience in conducting energy assessment for small and median manufacturing enterprises. We have made recommendations that have the potential to save about $20M annually. We also initiated research projects to meet DOE priorities, specifically in the areas of smart manufacturing and cybersecurity. On the energy assessment side, the Center has provided energy assessments to 144 qualified companies, primarily located in Indiana. On the training side, the center has trained students in various programs, such as the department’s Bachelor of Science (BS) programs in Mechanical Engineering (ME) and BS in Energy Engineering (EEN), both are ABET accredited engineering programs, as well as a graduate level Energy Management and Assessment certificate program. At the present, the center has trained 95 students, 43 or them received the DOE issued certificates. Research projects were developed within the center to advance energy efficiency related technologies, which provided excellent opportunities for our trainees. The center has also been building a professional network with utilities, Manufacturing Extension Partnership (MEP), government agencies, and manufacturing companies, to increase our client base and promote collaborations. The center received the 2019 Center of Excellence of the Year Award and three students received the “Outstanding Achievement in Energy Engineering by an IAC Student” awards in the past five years.

42 ENGINEERING↗

Applications of MODIS Fluorescent Line Height Measurements to Monitor Water Quality Trends and Algal Bloom Activity

Recent advances in satellite and airborne remote sensing, such as improvements in sensor and algorithm calibrations, processing techniques and atmospheric correction procedures have provided for increased coverage of remote-sensing, ocean-color products for coastal regions. In particular, for the Moderate Resolution Imaging Spectrometer (MODIS) sensor calibration updates, improved aerosol retrievals and new aerosol models has led to improved atmospheric correction algorithms for turbid waters and have improved the retrieval of ocean color in coastal waters. This has opened the way for studying ocean phenomena and processes at finer spatial scales, such as the interactions at the land-sea interface, trends in coastal water quality and algal blooms. Human population growth and changes in coastal management practices have brought about significant changes in the concentrations of organic and inorganic, particulate and dissolved substances entering the coastal ocean. There is increasing concern that these inputs have led to declines in water quality and have increase local concentrations of phytoplankton, which cause harmful algal blooms. In two case studies we present MODIS observations of fluorescence line height (FLH) to 1) assess trends in water quality for Tampa Bay, Florida and 2) illustrate seasonal and annual variability of algal bloom activity in Monterey Bay, California as well as document estuarine/riverine plume induced red tide events. In a comprehensive analysis of long term (2003-2011) in situ monitoring data and satellite imagery from Tampa Bay we assess the validity of the MODIS FLH product against chlorophyll-a and a suite of water quality parameters taken in a variety of conditions throughout a large optically complex estuarine system. A systematic analysis of sampling sites throughout the bay is undertaken to understand how the relationship between FLH and in situ chlorophyll-a responds to varying conditions and to develop a near decadal trend in water quality changes. In situ monitoring locations that correlated well with satellite imagery were in depths greater than seven meters and were located over five kilometers from shore. Water quality parameter of total nitrogen, phosphorous, turbidity and biological oxygen demand had high correlations with these sites, as well. Satellite FLH estimates show improving water quality from 2003-2007 with a slight decline up through 2011. Dinoflagellate blooms in Monterey Bay, California (USA) have recently increased in frequency and intensity. Nine years of MODIS FLH observations are used to describe the annual and seasonal variability of bloom activity within the Bay. Three classes of MODIS algorithms were correlated against in situ chlorophyll measurements. The FLH algorithm provided the most robust estimate of bloom activity. Elevated concentrations of phytoplankton were evident during the months of August-November, a period during which increased occurrences of dinoflagellate blooms have been observed in situ. Seasonal patterns of FLH show the on- and offshore movement of areas of high phytoplankton biomass between oceanographic seasons. Higher concentrations of phytoplankton are also evident in the vicinity of the land-based nutrient sources and outflows, and the cyclonic bay-wide circulation can transport these nutrients to the northern Bay bloom incubation region. Both of these case studies illustrate the utility MODIS FLH observations in supporting management decisions in coastal and estuarine waters.

Fischer, Andrew↗

2023 Annual Report of Available Drawdowns for Each Oil Storage Cavern in the Strategic Petroleum Reserve

DOE maintains an up-to-date documentation of the number of available full drawdowns of each of the caverns at the U.S. Strategic Petroleum Reserve (SPR). This information is important for assessing the SPR’s ability to deliver oil to domestic oil companies expeditiously if national or world events dictate a rapid sale and deployment of the oil reserves. Sandia was directed to develop and implement a process to continuously assess and report the evolution of drawdown capacity, the subject of this report. This report covers impacts on drawdown availability due to SPR operations during Calendar Year 2022. A cavern has an available drawdown if, after that drawdown, the long-term stability of the cavern, the cavern field, or the oil quality are not compromised. Thus, determining the number of available drawdowns requires the consideration of several factors regarding cavern and wellbore integrity and stability, including stress states caused by cavern geometry and operations, salt damage caused by dilatant and tensile stresses, the effect of enhanced creep on wellbore integrity, and the sympathetic stress effect of operations on neighboring caverns. Finite-element geomechanical models have been used to determine the stress states in the pillars following successive drawdowns. By computing the tensile and dilatant stresses in the salt, areas of potential structural instability can be identified that may represent red flags for additional drawdowns. These analyses have found that many caverns will maintain structural integrity even when grown via drawdowns to dimensions resulting in a pillar-to-diameter ratio of less than 1.0. The analyses have also confirmed that certain caverns should only be completely drawn down one time. As the SPR caverns are utilized and partial drawdowns are performed to remove oil from the caverns (e.g., for oil sales, purchases, or exchanges authorized by the Congress or the President), the changes to the cavern caused by these procedures must be tracked and accounted for so that an ongoing assessment of the cavern’s drawdown capacity may be continued. A methodology for assessing and tracking the available drawdowns for each cavern is reiterated. This report is the latest in a series of annual reports, and it includes the baseline available drawdowns for each cavern, and the most recent assessment of the evolution of drawdown expenditures. A total of 222 million barrels of oil were released in calendar-year 2022. A nearly-equal amount of raw water was injected, resulting in an estimated 34 million barrels of cavern leaching. Twenty caverns have now expended a full drawdown. Cavern BC 18 has expended all its baseline available drawdowns, and has no drawdowns remaining. Cavern BM 103 has expended one of its two baseline drawdowns, and is now a single-drawdown cavern. All other caverns with an expenditure went from at-least-5 to at-least-4 remaining drawdowns.

02 PETROLEUM↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma: Preprint

This study builds on the existing techno-economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system’s resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system’s heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma

This study builds on the existing techno economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system's resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system's heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Hydrokinetic tidal energy resource assessment following international electrotechnical commission guidelines

Marine renewable energy can be used as a viable energy source to alleviate the impact of the climate crisis and have a carbon-free electricity sector in the future. Especially the energetic tidal streams are an attractive source of clean energy due to the periodic occurrence of high tidal flows daily. However, before any deployment of tidal turbine farms, it is essential to perform a resource assessment depending on the scope and scale of the project. Here, the International Electrotechnical Commission has developed a technical standard for assessing the tidal stream resource "IEC 62600-201 TS" to aid in this effort: determine a particular site's feasibility and perform the project layout design. In this study, we implemented and validated a high-resolution three-dimensional numerical model and provided results following the IEC TS for a project layout design in a highly energetic tidal channel, Tacoma Narrows of Puget Sound, in the State of Washington, USA. Implementation of the guidelines has helped adequately identify the undisturbed theoretical and technical resources with less bias, where the latter included energy extraction from the flow field arranging a hypothetical tidal energy converter (TEC) array. Also, following the standard, we carefully assessed the changes to channel flow properties from TECs, such as the kinetic energy flux and annual energy production (AEP), to provide the detailed information required for a larger project layout design. Ultimately, this work has shown the important role of IEC TS in tidal stream resource assessment, which can simultaneously act as a benchmark for other studies worldwide.

13 HYDRO ENERGY↗

Historical and projected future runoff over the Mekong River basin

The Mekong River (MR) crosses the borders and connects six countries, including China, Myanmar, Laos, Thailand, Cambodia, and Vietnam. It provides critical water resources and supports natural and agricultural ecosystems, socioeconomic development, and the livelihoods of the people living in this region. Understanding changes in the runoff of this important international river under projected climate change is critical for water resource management and climate change adaptation planning. However, research on long-term runoff dynamics for the MR and the underlying drivers of runoff variability remains scarce. Here, we analyse historical runoff variations from 1971 to 2020 based on runoff gauge data collected from eight hydrological stations along the MR. With these runoff data, we then evaluate the runoff simulation performance of five global hydrological models (GHMs) forced by four global climate models (GCMs) under the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP). Furthermore, based on the best simulation combination, we quantify the impact of future climate change on river runoff changes in the MR. The result shows that the annual runoff in the MR has not changed significantly in the past 5 decades, while the establishment of dams and reservoirs in the basin visibly affected the annual runoff distribution. The ensemble-averaged result of the Water Global Assessment and Prognosis version 2 (WaterGAP2; i.e. GHM) forced by four GCMs has the best runoff simulation performance. Under Representative Concentration Pathways (RCPs; i.e. RCP2.6, RCP6.0 and RCP8.5), the runoff of the MR is projected to increase significantly (p<0.05); e.g. 3.81 ± 3.47 m 3 s -1 a -1 (9 ± 8 % increase in 100 years) at the upper reach under RCP2.6 and 16.36 ± 12.44 m 3 s -1 a -1 (13 ±10 % increase in 100 years) at the lower reach under RCP6.0. In particular, under the RCP6.0 scenario, the increase in annual runoff is most pronounced in the middle and lower reaches, due to increased precipitation and snowmelt. Under the RCP8.5 scenario, the runoff distribution in different seasons varies obviously, increasing the risk of flooding in the wet season and drought in the dry season.

54 ENVIRONMENTAL SCIENCES↗

Available Drawdowns for Each Oil Storage Cavern in the Strategic Petroleum Reserve (2021 Annual Report)

The Department of Energy maintains an up-to-date documentation of the number of available full drawdowns of each of the caverns owned by the Strategic Petroleum Reserve (SPR). This information is important for assessing the SPRs ability to deliver oil to domestic oil companies expeditiously if national or world events dictate a rapid sale and deployment of the oil reserves. Sandia was directed to develop and implement a process to continuously assess and report the evolution of drawdown capacity, the subject of this report. A cavern has an available drawdown if after that drawdown, the long-term stability of the cavern, the cavern field, or the oil quality are not compromised. Thus, determining the number of available drawdowns requires the consideration of several factors regarding cavern and wellbore integrity and stability, including stress states caused by cavern geometry and operations, salt damage caused by dilatant and tensile stresses, the effect of enhanced creep on wellbore integrity, and the sympathetic stress effect of operations on neighboring caverns. A consensus has now been built regarding the assessment of drawdown capabilities and risks for the SPR caverns (Sobolik et al., 2014; Sobolik 2016). The process involves an initial assessment of the pillar - to - diameter (P/D) ratio for each cavern with respect to neighboring caverns. A large pillar thickness between adjacent caverns should be strong enough to withstand the stresses induced by closure of the caverns due to salt creep. The first evaluation of P/D includes a calculation of the evolution of P/D after a number of full cavern drawdowns. The most common storage industry standard is to keep this value greater than 1.0, which should ensure a pillar thick enough to prevent loss of fluids to the surrounding rock mass. However, many of the SPR caverns currently have a P/D less than 1.0 or will likely have a low P/D after one or two full drawdowns. For these caverns, it is important to examine the structural integrity with more detail using geomechanical models. Finite-element geomechanical models have been used to determine the stress states in the pillars following successive drawdowns. By computing the tensile and dilatant stresses in the salt, areas of potential structural instability can be identified that may represent red flags for additional drawdowns. These analyses have found that many caverns will maintain structural integrity even when grown via drawdowns to dimensions resulting in a P/D of less than 1.0. The analyses have also confirmed that certain caverns should only be completely drawn down one time. As the SPR caverns are utilized and partial drawdowns are performed to remove oil from the caverns (e.g., for occasional oil sales , purchases, or exchanges authorized by the Congress or the President), the changes to the cavern caused by these procedures must be tracked and accounted for so that an ongoing assessment of the caverns drawdown capacity may be continued. A proposed methodology for assessing and tracking the available drawdowns for each cavern was presented in Sobolik et al. (2018). This report is the latest in a series of annual reports, and it includes the baseline available drawdowns for each cavern, and the most recent assessment of the evolution of drawdown expenditure for several caverns .

02 PETROLEUM↗

Available Drawdowns for Each Oil Storage Cavern in the Strategic Petroleum Reserve (2022 Annual Report)

The Department of Energy maintains an up-to-date documentation of the number of available full drawdowns of each of the caverns owned by the Strategic Petroleum Reserve (SPR). This information is important for assessing the SPR's ability to deliver oil to domestic oil companies expeditiously if national or world events dictate a rapid sale and deployment of the oil reserves. Sandia was directed to develop and implement a process to continuously assess and report the evolution of drawdown capacity, the subject of this report. A cavern has an available drawdown if after that drawdown, the long-term stability of the cavern, the cavern field, or the oil quality are not compromised. Thus, determining the number of a vailable drawdowns requires the consideration of several factors regarding cavern and wellbore integrity and stability, including stress states caused by cavern geometry and operations, salt damage caused by dilatant and tensile stresses, the effect of enhanced creep on wellbore integrity, and the sympathetic stress effect of operations on neighboring caverns. A consensus has now been built regarding the assessment of drawdown capabilities and risks for the SPR caverns (Sobolik et al., 2014; Sobolik 2016). The process involves an initial assessment of the pillar-to-diameter (P/D) ratio for each cavern with respect to neighboring caverns. A large pillar thickness between adjacent caverns should be strong enough to withstand the stresses induced by closure of the caverns due to salt creep. The first evaluation of P/D includes a calculation of the evolution of P/D after a number of full cavern drawdowns. The most common storage industry standard is to keep this value greater than 1.0, which should ensure a pillar thick enough to prevent loss of fluids to the surrounding rock mass. However, many of the SPR caverns currently have a P/D less than 1.0 or will likely have a low P/D after one or two full drawdowns. For these caverns, it is important to examine the s tructural integrity with more detail using geomechanical models. Finite - element geomechanical models have been used to determine the stress states in the pillars following successive drawdowns. By computing the tensile and dilatant stresses in the salt, areas of potential structural instability can be identified that may represent "red flags" for additional drawdowns. These analyses have found that many caverns will maintain structural integrity even when grown via drawdowns to dimensions resulting in a P/D of less than 1.0. The analyses have also confirmed that certain caverns should only be completely drawn down one time. As the SPR caverns are utilized and partial drawdowns are performed to remove oil from the caverns (e.g., for occasional oil sales , purchases, or exchanges authorized by the Congress or the President), the changes to the cavern caused by these procedures must be tracked and accounted for so that an ongoing assessment of the cavern's drawdown capacity may be continued. A proposed methodology for assessing and tracking the available drawdowns for each cavern was presented in Sobolik et al. (2018). This report is the latest in a series of annual reports, and it includes the baseline available drawdowns for each cavern, and the most recent assessment of the evolution of drawdown expenditure for several caverns.

02 PETROLEUM↗

Wabash CarbonSAFE Static and Dynamic Modeling: Task 9.0 (Technical Report)

The objective of the Wabash CarbonSAFE project’s static and dynamic modeling task is to assess the feasibility of storing 50 million tonnes (1.67 million metric tonnes annually; MMTA) of industrially-sourced carbon dioxide (CO 2 ) in a commercial-scale geological storage complex at Wabash Valley Resources LLC (WVR) gasification facility near Terre Haute, Indiana over a period of 30 years. The targeted formations for storing CO 2 are: 1) Mt. Simon Sandstone (MSS) and the 2) Potosi Dolomite (Knox Group). All of the available data from the recently drilled Wabash #1 stratigraphic test well (now plugged and abandoned) were used in the construction of both the static and dynamic models. Geologic models were constructed to characterize both the Mt. Simon Sandstone and Potosi Dolomite storage complexes. Dynamic simulation models were constructed and used to assess the feasibility of injecting CO 2 into the Mt. Simon and Potosi formations. The geocellular models for the Potosi Dolomite and Mt. Simon Sandstone were built using Petrel™, Schlumberger’s reservoir modeling software. The dynamic simulations were run using Landmark’s Nexus ® reservoir simulation software.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Influence of sampling frequency and estimation method on phosphorus load uncertainty in the Western Lake Erie Basin, Ohio, USA

Accurate estimates of nutrient loads are necessary to identify critical source areas and quantify the impact of management practices on pollutant export. Previous studies have investigated nutrient load estimate uncertainty, but they often focus on nutrient loads estimated using an interpolation method for large-scale watersheds with short-term datasets. The study objective was to quantify uncertainty in soluble reactive phosphorus (SRP), total phosphorus (TP), and suspended solids (SS) load estimates from two small (<10 3 km 2 ) agricultural watersheds in the western Lake Erie Basin resulting from different sampling frequencies. Each watershed had high temporal resolution datasets of discharge (15 min) and nutrient concentration (1 to 3 samples per day) collected over a 30-year period (1990–2020). Firstly, SRP, TP, and SS loads were calculated using the high temporal resolution datasets, which was assumed as “true loads”. Secondly, the high temporal concentration data were decomposed to semiweekly, weekly, biweekly, and monthly sampling and annual loads were estimated using four common load estimation methods to assess the effect of sampling frequency and load estimation method on load estimate error. Across the four different methods, the composite method had the lowest relative root mean square and absolute bias, but the rectangular interpolation method was the most precise. Furthermore, even with semiweekly sampling, the composite method resulted in an unacceptable level of precision (average imprecision = 39 %), while the interpolation method resulted in an unacceptable bias (average absolute bias = 16 %). Because neither method could provide acceptable accuracy and precision at the lowest decrease in sampling (e.t. semiweekly sampling), continued daily sampling is recommended in these watersheds.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of historical precipitation interannual variability in CMIP6 over the United States

Interannual precipitation variability profoundly influences society via its effects on agriculture, water resources, infrastructure, and disaster risks. In this study, we use daily in situ precipitation observations from the global historical climatology network-daily (GHCN-D) to assess the ability of 21 Coupled Model Intercomparison Project Phase 6 (CMIP6) models, including the 50-member fifth-generation Canadian Earth System Model single model initial-condition large ensemble (CanESM5_SMILE), to realistically simulate historical interannual precipitation variability trends within 17 regions of the contiguous United States (CONUS). We assess how accurately the CMIP6 simulations align with observational data across annual, summer, and winter periods, focusing on four key hydrometeorological metrics, including interannual precipitation variability, relative interannual precipitation variability (coefficient of variation), annual mean precipitation, and annual wet day frequency. Our findings reveal that CMIP6 ensemble members generally reproduce the spatial patterns of observed trends in annual mean precipitation. In most regions, models agree well with the signs of observed changes in annual mean precipitation, though discrepancies in trend magnitude are evident. Further, observed trends in winter mean precipitation broadly exhibit a spatial pattern similar to that of the observed annual mean. However, analysis of the CanESM5_SMILE shows that trends in precipitation variability may primarily be the result of model-simulated internal variability, suggesting caution in interpreting multi-model single-realization ensemble results. Challenges in accurately simulating interannual precipitation variability underscore the need for ongoing model refinement and validation to enhance climate projections, especially in regions vulnerable to extreme precipitation events.

54 ENVIRONMENTAL SCIENCES↗

“QGP Signatures” revisited

Abstract We revisit the graphic table of QCD signatures in our 1996 Annual Reviews article “The Search for the Quark–Gluon Plasma” and assess the progress that has been made since its publication towards providing quantitative evidence for the formation of a quark–gluon plasma in relativistic heavy-ion collisions and its characteristic properties.

Physics↗

Characteristics of Veterans With Depression Who Use the Veterans Choice Program of the Veterans Health Administration

Objective: The Veterans Choice Program (VCP) of the Veterans Health Administration (VHA) allowed eligible veterans to use their benefits with participating providers outside the VHA. The authors aimed to identify characteristics of veterans with depression who used or did not use mental health care through the VCP. Methods: In this cross-sectional study, the authors analyzed secondary data from the national VHA Corporate Data Warehouse. VHA administrative data were linked with VCP claims to examine characteristics of VCP-eligible veterans with depression. Further, the study sample included 595,943 unique veterans who were enrolled in the VHA before 2013, were eligible for the VCP in 2016, were alive in 2018, and had an assessed Patient Health Questionnaire–9 (PHQ-9) score or depressive disorder diagnosis documented in the VHA between 2016 and 2018. Results: Veterans who used the VCP had lower medical comorbidity scores and lived in less socioeconomically disadvantaged counties, compared with veterans who received only VHA care. VCP veterans were also more likely to have a PHQ-9 score assessment and to have higher mean depression scores. Mean counts of annual mental health visits per 1,000 veterans were markedly higher for direct VHA care than for care provided via the VCP. As a percentage of the total counts of visits per 1,000 veterans across the VCP and VHA, residential programs and outpatient procedures were the services that were most frequently delivered through the VCP. Conclusions: Between 2016 and 2018, the VCP was used primarily to augment mental health care provided by the VHA, rather than to fill a gap in care.

60 APPLIED LIFE SCIENCES↗