SEARCH · Engineering Papers
Results for “angle”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Angle-Multiplexed Metasurfaces: Encoding Independent Wavefronts in a Single Metasurface under Different Illumination Angles
Not Available
On the estimation of statistical uncertainties on powder diffraction and small-angle scattering data from two-dimensional X-ray detectors
Optimal methods are explored for obtaining one-dimensional powder pattern intensities from two-dimensional planar detectors with good estimates of their standard deviations. Methods are described to estimate uncertainties when the same image is measured in multiple frames as well as from a single frame. The importance of considering the correlation of diffraction points during the integration and the resampling process of data analysis is shown. It is found that correlations between adjacent pixels in the image can lead to seriously overestimated uncertainties if such correlations are neglected in the integration process. Off-diagonal entries in the variance–covariance (VC) matrix are problematic as virtually all data processing and modeling programs cannot handle the full VC matrix. It is shown that the off-diagonal terms come mainly from the pixel-splitting algorithm used as the default integration algorithm in many popular two-dimensional integration programs, as well as from rebinning and resampling steps later in the processing. When the full VC matrix can be propagated during the data reduction, it is possible to get accurate refined parameters and their uncertainties at the cost of increasing computational complexity. However, as this is not normally possible, the best approximate methods for data processing in order to estimate uncertainties on refined parameters with the greatest accuracy from just the diagonal variance terms in the VC matrix is explored.
Ultrabroadband and Wide-Angle Hybrid Antireflection Coatings With Nanostructures
Explore the source record for details and available documents.
Performance of a Grid-Forming Inverter Under Balanced and Unbalanced Voltage Phase Angle Jump Conditions .
Abstract not provided.
Design of wide-angle selective absorbers/emitters with dielectric filled metallic photonic crystals for energy applications
Explore the source record for details and available documents.
Multilayer-coated blazed grating with variable line spacing and a variable blaze angle
Not Available
Angle-resolved coherent wave mixing using a 4 fs ultra-broad bandwidth laser
Not Available
Angle performance on optima MDxt
Angle control on medium current implanters is important due to the high angle-sensitivity of typical medium current implants, such as halo implants. On the Optima MDxt, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through six narrow slits, and any angle adjustment is made by electrostatically steering the beam, while cross-wafer beam parallelism is adjusted by changing the focus of the electrostatic parallelizing lens (P-lens). In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightly tilting the wafer platen prior to implant. A variety of tests were run to measure the accuracy and repeatability of Optima MDxt's angle control. SIMS profiles of a high energy, channeling sensitive condition show both the cross-wafer angle uniformity, along with the small-angle resolution of the system. Angle repeatability was quantified by running a channeling sensitive implant as a regular monitor over a seven month period and measuring the sheet resistance-to-angle sensitivity. Even though crystal cut error was not controlled for in this case, when attributing all Rs variation to angle changes, the overall angle repeatability was measured as 0.16 Degree-Sign (1{sigma}). A separate angle repeatability test involved running a series of V-curves tests over a four month period using low crystal cut wafers selected from the same boule. The results of this test showed the angle repeatability to be <0.1 Degree-Sign (1{sigma}).
Implant Angle Monitor System of MC3-II
Precise implant angle control is required for the latest generation of ion implanters to meet further shrink semiconductor device requirements. Especially, the highest angle accuracy is required for Halo implant process of Logic devices. The Halo implant angle affects the device performance, because slight differences of beam divergence change the overlap profile towards the extension. Additionally, twist angle accuracy is demanded in case of channeling angle implant. Therefore monitoring beam angles and wafer twist angles is important. A new monitoring system for the MC3-II, SEN Corp.'s single wafer type medium current implanter has been developed. This paper describes the angle control performance and monitoring system of the MC3-II. For the twist angle control, we developed a wafer notch angle monitor. The system monitors the wafer notch image on the platen. And the notch angle variation is calculated by using image processing method. It is also able to adjust the notch angle according to the angle error. For the tilt angle control, we developed a vertical beam profile monitor. The monitor system can detect beam profile of vertical directions with horizontally scanning beam. It also measures beam angles of a tilt direction to a wafer. The system configuration and sample beam data are presented.
Magic angle hierarchy in twisted graphene multilayers
When two monolayers of graphene are stacked with a small relative twist angle, the resulting band structure exhibits a remarkably flat pair of bands at a sequence of "magic angles" where correlation effects can induce a host of exotic phases. Here we study a class of related models of n -layered graphene with an alternating relative twist angle ±θ which exhibits magic angle flat bands coexisting with several Dirac dispersing bands at the moiré K point. Remarkably, we find that the Hamiltonian for the multilayer system can be mapped exactly to a set of decoupled bilayers at different angles, revealing a remarkable hierarchy mathematically relating all these magic angles to the TBG case. For the trilayer case ( n =3), we show that the sequence of magic angle is obtained by multiplying the bilayer magic angles by $\sqrt{2}$, whereas the quadrilayer case ( n =4) has two sequences of magic angles obtained by multiplying the bilayer magic angles by the golden ratio φ=($\sqrt{5}$+1)/2≈1.62 and its inverse. We also show that for larger n , we can tune the angle to obtain several narrow (almost flat) bands simultaneously and that for n → ∞, there is a continuum of magic angles for θ ≲ 2°. Furthermore, we show that tuning several perfectly flat bands for a small number of layers is possible if the coupling between different layers is different. Furthermore, the setup proposed here can be readily achieved by repeatedly applying the "tear and stack" method without the need of any extra tuning of the twist angle and has the advantage that the first magic angle is always larger than the bilayer case.
SU-E-T-604: Dosimetric Dependence On the Collimator Angle in Prostate Volumetric Modulated Arc Therapy
Purpose: The purpose of this study is to investigate the dose-volume variations of planning target volume (PTV) and organs-at-risk (OARs) in prostate volumetric modulated arc therapy (VMAT) when using different collimator angles. It is because collimator angle awareness is essential for planner to produce an optimal prostate VMAT plan in a rational time. Methods: Single-arc VMAT plans at different collimator angles (0o, 15o, 30o, 45o, 60o, 75o and 90o) were created systematically using a Harold heterogeneous pelvis phantom. For each change of collimator angle, a new plan was re-optimized for that angle. The prescription dose was 78 Gy per 39 fractions. Conformity index (CI), homogeneity index (HI), gradient index, machine monitor unit, dose-volume histogram, the mean and maximum doses of the PTV were calculated and analyzed. On the other hand, dose-volume histogram, the mean and maximum doses of the OARs such as bladder, rectum and femoral heads for different collimator angles were determined from the plans. Results: There was no significance difference, based on the plan dose-volume evaluation criteria, found in the VMAT optimizations for all studied collimator angles. Higher CI and lower HI were found for the 45o collimator angle. In addition, the 15o collimator angle provided lower HI similar to the 45o collimator angle. The 75o and 90o collimator angle were found good for the rectum sparing, and the 75o and 30o collimator angle were found good for the right and left femur sparing, respectively. The PTV dose coverage for each plan was comparatively independent of the collimator angle. Conclusion: The dosimetric results in this study are useful to the planner to select different collimator angles to improve the PTV coverage and OAR sparing in prostate VMAT.
Conceptual study on using Doppler backscattering to measure magnetic pitch angle in tokamak plasmas
We introduce a new approach to measure the magnetic pitch angle profile in tokamak plasmas with Doppler backscattering (DBS), a technique traditionally used for measuring flows and density fluctuations. The DBS signal is maximised when its probe beam's wavevector is perpendicular to the magnetic field at the cutoff location, independent of the density fluctuations [Hillesheim \emph{et al} 2022 \emph{Nucl. Fusion} \textbf{55} 073024]. Hence, if one could isolate this effect, DBS would then yield information about the magnetic pitch angle. By varying the toroidal launch angle, the DBS beam reaches cutoff with different angles with respect to the magnetic field, but with other properties remaining similar. Hence, the toroidal launch angle which gives maximum backscattered power is thus that which is matched to the pitch angle at the cutoff location, enabling inference of the magnetic pitch angle. We performed systematic scans of the DBS toroidal launch angle for repeated DIII-D tokamak discharges. Experimental DBS data from this scan were analysed and combined with Gaussian beam-tracing simulations using the Scotty code [Hall-Chen \emph{et al} 2022 \emph{Plasma Phys. Control. Fusion} \textbf{64} 095002]. The pitch-angle inferred from DBS is consistent with that from magnetics-only and motional-Stark-effect-constrained (MSE) equilibrium reconstruction in the edge. In the core, the pitch angles from DBS and magnetics-only reconstructions differ by one to two degrees, while simultaneous MSE measurements were not available. The uncertainty in these measurements was under a degree; we show that this uncertainty is primarily due to the error in toroidal steering, the number of toroidally separated measurements, and shot-to-shot repeatability. We find that the error of pitch-angle measurements can be reduced by optimising the poloidal launch angle and initial beam properties. Since DBS has high spatial and temporal resolutions, is non-perturbative, does not require neutral beams, and is likely robust to neutron damage of and debris on the first mirrors, using DBS to measure the pitch angle in future fusion energy systems is especially appealing.
Optimization of the x-ray monitoring angle for creating a correlation model between internal and external respiratory signals
Purpose: To perform dynamic tumor tracking irradiation with the Vero4DRT (MHI-TM2000), a correlation model [four dimensional (4D) model] between the displacement of infrared markers on the abdominal wall and the three-dimensional position of a tumor indicated by a minimum of three implanted gold markers is required. However, the gold markers cannot be detected successfully on fluoroscopic images under the following situations: (1) overlapping of the gold markers; and (2) a low intensity ratio of the gold marker to its surroundings. In the present study, the authors proposed a method to readily determine the optimal x-ray monitoring angle for creating a 4D model utilizing computed tomography (CT) images. Methods: The Vero4DRT mounting two orthogonal kV x-ray imaging subsystems can separately rotate the gantry along an O-shaped guide-lane and the O-ring along its vertical axis. The optimal x-ray monitoring angle was determined on CT images by minimizing the root-sum-square of water equivalent path lengths (WEPLs) on the orthogonal lines passing all of the gold markers while rotating the O-ring and the gantry. The x-ray monitoring angles at which the distances between the gold markers were within 5 mm at the isocenter level were excluded to prevent false detection of the gold markers in consideration of respiratory motions. First, the relationship between the WEPLs (unit: mm) and the intensity ratios of the gold markers was examined to assess the validity of our proposed method. Second, our proposed method was applied to the 4D-CT images at the end-expiration phase for 11 lung cancer patients who had four to five gold markers. To prove the necessity of the x-ray monitoring angle optimization, the intensity ratios of the least visible markers (minimum intensity ratios) that were estimated from the WEPLs were compared under the following conditions: the optimal x-ray monitoring angle and the angles used for setup verification. Additionally, the intra- and interfractional variations in the intensity ratio were examined from the optimal x-ray monitoring angle. Results: A negative strong correlation was observed between the WEPL (x) and the intensity ratio (y) (y= 6.57 exp[-0.0125x]+ 1, R=-0.88 [95% confidence interval: -0.85 to -0.90], p < 0.01). Our proposed method effectively avoided having the x-ray beam pass through high-density structures, although there were large interpatient variations in the optimal x-ray monitoring angle because of the geometric arrangement between the gold markers and the anatomical structures. The minimum intensity ratios that were estimated from the WEPLs at the optimal x-ray monitoring angle ranged from 1.43 to 2.48, which was an average of 1.27 times (range, 1.02-1.66) higher than the angles used for setup verification. The maximum intra- and interfractional decreases in the intensity ratio were 0.23 and 0.17, respectively. Conclusions: The authors demonstrated that the optimal x-ray monitoring angle for creating a 4D model can improve the visibility of gold markers.
SU-F-T-177: Impacts of Gantry Angle Dependent Scanning Beam Properties for Proton Treatment
Purpose: In pencil beam scanning (PBS), the delivered spot MU, position and size are slightly different at different gantry angles. We investigated the level of delivery uncertainty at different gantry angles through a log file analysis. Methods: 34 PBS fields covering full 360 degrees gantry angle spread were collected retrospectively from 28 patients treated at our institution. All fields were delivered at zero gantry angle and the prescribed gantry angle, and measured at isocenter with the MatriXX 2D array detector at the prescribed gantry angle. The machine log files were analyzed to extract the delivered MU per spot and the beam position from the strip ionization chambers in the treatment nozzle. The beam size was separately measured as a function of gantry angle and beam energy. Using this information, the dose was calculated in a water phantom at both gantry angles and compared to the measurement using the 3D γ-index at 2mm/2%. Results: The spot-by-spot difference between the beam position in the log files from the delivery at the two gantry angles has a mean of 0.3 and 0.4 mm and a standard deviation of 0.6 and 0.7 mm for × and y directions, respectively. Similarly, the spot-by-spot difference between the MU in the log files from the delivery at the two gantry angles has a mean 0.01% and a standard deviation of 0.7%. These small deviations lead to an excellent agreement in dose calculations with an average γ pass rate for all fields being approximately 99.7%. When each calculation is compared to the measurement, a high correlation in γ was also found. Conclusion: Using machine logs files, we verified that PBS beam delivery at different gantry angles are sufficiently small and the planned spot position and MU. This study brings us one step closer to simplifying our patient-specific QA.
Calculation of contact angles at triple phase boundary in solid oxide fuel cell anode using the level set method
A level set method is applied to characterize the three dimensional structures of nickel, yttria stabilized zirconia and pore phases in solid oxide fuel cell anode reconstructed by focused ion beam-scanning electron microscope. A numerical algorithm is developed to evaluate the contact angles at the triple phase boundary based on interfacial normal vectors which can be calculated from the signed distance functions defined for each of the three phases. Furthermore, surface tension force is estimated from the contact angles by assuming the interfacial force balance at the triple phase boundary. The average contact angle values of nickel, yttria stabilized zirconia and pore are found to be 143°–156°, 83°–138° and 82°–123°, respectively. The mean contact angles remained nearly unchanged after 100 hour operation. However, the contact angles just after reduction are different for the cells with different sintering temperatures. In addition, standard deviations of the contact angles are very large especially for yttria stabilized zirconia and pore phases. The calculated surface tension forces from mean contact angles were close to the experimental values found in the literature. Slight increase of surface tensions of nickel/pore and nickel/yttria stabilized zirconia were observed after operation. Present data are expected to be used not only for the understanding of the degradation mechanism, but also for the quantitative prediction of the microstructural temporal evolution of solid oxide fuel cell anode. - Highlights: • A level set method is applied to characterize the 3D structures of SOFC anode. • A numerical algorithm is developed to evaluate the contact angles at the TPB. • Surface tension force is estimated from the contact angles. • The average contact angle values are found to be 143o-156o, 83o-138o and 82o-123o. • Present data are expected to understand degradation and predict evolution of SOFC.
Beyond-Cassie Mode of Wetting and Local Contact Angles of Droplets on Checkboard-Patterned Surfaces
Droplet wetting and distortion on flat surfaces with heterogeneous wettability are studied using the 3D Shan–Chen pseudopotential multiphase lattice Boltzmann model (LBM). The contact angles are compared with the Cassie mode, which predicts an apparent contact angle for flat surfaces with different wetting properties, where the droplet size is large compared to the size of the heterogeneity. The surface studied consists in a regular checkboard pattern with two different Young’s contact angles (hydrophilic and hydrophobic) and equal surface fraction. The droplet size and patch size of the checkboard are varied beyond the limit where Cassie’s equation is valid. A critical ratio of patch size to droplet radius is found below which the apparent contact angle follows the Cassie mode. Above the critical value, the droplet shape changes from a spherical cap to a more distorted form, and no single contact angle can be determined. The local contact angles are found to vary along the contact line between minimum and maximum values. The droplet is found to wet preferentially the hydrophilic region, and the wetted area fraction of the hydrophilic region increases quasi-linearly with the ratio between patch and droplet sizes. We propose a new equation beyond the critical ratio, defining an equivalent contact angle, where the wetted area fractions are used as weighting coefficients for the maximum and minimum local contact angles. This equivalent contact angle is found to equal Cassie’s contact angle.