Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “XFELs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Time-resolved RIXS experiment with pulse-by-pulse parallel readout data collection using X-ray free electron laser

Abstract Time-resolved resonant inelastic X-ray scattering (RIXS) is one of the developing techniques enabled by the advent of X-ray free electron laser (FEL). It is important to evaluate how the FEL jitter, which is inherent in the self-amplified spontaneous emission process, influences the RIXS measurement. Here, we use a microchannel plate (MCP) based Timepix soft X-ray detector to conduct a time-resolved RIXS measurement at the Ti L 3 -edge on a charge-density-wave material TiSe 2 . The fast parallel Timepix readout and single photon sensitivity enable pulse-by-pulse data acquisition and analysis. Due to the FEL jitter, low detection efficiency of spectrometer, and low quantum yield of RIXS process, we find that less than 2% of the X-ray FEL pulses produce signals, preventing acquiring sufficient data statistics while maintaining temporal and energy resolution in this measurement. These limitations can be mitigated by using future X-ray FELs with high repetition rates, approaching MHz such as the European XFEL in Germany and LCLS-II in the USA, as well as by utilizing advanced detectors, such as the prototype used in this study.

36 MATERIALS SCIENCE↗

Physics constrained unsupervised deep learning for rapid, high resolution scanning coherent diffraction reconstruction

By circumventing the resolution limitations of optics, coherent diffractive imaging (CDI) and ptychography are making their way into scientific fields ranging from X-ray imaging to astronomy. Yet, the need for time consuming iterative phase recovery hampers real-time imaging. While supervised deep learning strategies have increased reconstruction speed, they sacrifice image quality. Furthermore, these methods’ demand for extensive labeled training data is experimentally burdensome. Here, we propose an unsupervised physics-informed neural network reconstruction method, PtychoPINN, that retains the factor of 100-to-1000 speedup of deep learning-based reconstruction while improving reconstruction quality by combining the diffraction forward map with real-space constraints from overlapping measurements. In particular, PtychoPINN gains a factor of 4 in linear resolution and an 8 dB improvement in PSNR while also accruing improvements in generalizability and robustness. This blend of performance and computational efficiency offers exciting prospects for high-resolution real-time imaging in high-throughput environments such as X-ray free electron lasers (XFELs) and diffraction-limited light sources.

97 MATHEMATICS AND COMPUTING↗

Helium-electrospray improves sample delivery in X-ray single-particle imaging experiments

Abstract Imaging the structure and observing the dynamics of isolated proteins using single-particle X-ray diffractive imaging (SPI) is one of the potential applications of X-ray free-electron lasers (XFELs). Currently, SPI experiments on isolated proteins are limited by three factors: low signal strength, limited data and high background from gas scattering. The last two factors are largely due to the shortcomings of the aerosol sample delivery methods in use. Here we present our modified electrospray ionization (ESI) source, which we dubbed helium-ESI (He-ESI). With it, we increased particle delivery into the interaction region by a factor of 10, for 26 nm-sized biological particles, and decreased the gas load in the interaction chamber corresponding to an 80% reduction in gas scattering when compared to the original ESI. These improvements have the potential to significantly increase the quality and quantity of SPI diffraction patterns in future experiments using He-ESI, resulting in higher-resolution structures.

Science & Technology - Other Topics↗

Efficient prediction of attosecond two-colour pulses from an X-ray free-electron laser with machine learning

Abstract X-ray free-electron lasers are sources of coherent, high-intensity X-rays with numerous applications in ultra-fast measurements and dynamic structural imaging. Due to the stochastic nature of the self-amplified spontaneous emission process and the difficulty in controlling injection of electrons, output pulses exhibit significant noise and limited temporal coherence. Standard measurement techniques used for characterizing two-coloured X-ray pulses are challenging, as they are either invasive or diagnostically expensive. In this work, we employ machine learning methods such as neural networks and decision trees to predict the central photon energies of pairs of attosecond fundamental and second harmonic pulses using parameters that are easily recorded at the high-repetition rate of a single shot. Using real experimental data, we apply a detailed feature analysis on the input parameters while optimizing the training time of the machine learning methods. Our predictive models are able to make predictions of central photon energy for one of the pulses without measuring the other pulse, thereby leveraging the use of the spectrometer without having to extend its detection window. We anticipate applications in X-ray spectroscopy using XFELs, such as in time-resolved X-ray absorption and photoemission spectroscopy, where improved measurement of input spectra will lead to better experimental outcomes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Site-specific interrogation of an ionic chiral fragment during photolysis using an X-ray free-electron laser

Abstract Short-wavelength free-electron lasers with their ultrashort pulses at high intensities have originated new approaches for tracking molecular dynamics from the vista of specific sites. X-ray pump X-ray probe schemes even allow to address individual atomic constituents with a ‘trigger’-event that preludes the subsequent molecular dynamics while being able to selectively probe the evolving structure with a time-delayed second X-ray pulse. Here, we use a linearly polarized X-ray photon to trigger the photolysis of a prototypical chiral molecule, namely trifluoromethyloxirane (C 3 H 3 F 3 O), at the fluorine K-edge at around 700 eV. The created fluorine-containing fragments are then probed by a second, circularly polarized X-ray pulse of higher photon energy in order to investigate the chemically shifted inner-shell electrons of the ionic mother-fragment for their stereochemical sensitivity. We experimentally demonstrate and theoretically support how two-color X-ray pump X-ray probe experiments with polarization control enable XFELs as tools for chiral recognition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visualizing plasmons and ultrafast kinetic instabilities in laser-driven solids using X-ray scattering

Ultra-intense lasers that ionize atoms and accelerate electrons in solids to near the speed of light can lead to kinetic instabilities that alter the laser absorption and subsequent electron transport, isochoric heating, and ion acceleration. These instabilities can be difficult to characterize, but X-ray scattering at keV photon energies allows for their visualization with femtosecond temporal resolution on the few nanometer mesoscale. Here, we perform such experiment on laser-driven flat silicon membranes that shows the development of structure with a dominant scale of 60 nm in the plane of the laser axis and laser polarization, and 95 nm in the vertical direction with a growth rate faster than 0.1 fs -1 . Combining the XFEL experiments with simulations provides a complete picture of the structural evolution of ultra-fast laser-induced plasma density development, indicating the excitation of plasmons and a filamentation instability. Particle-in-cell simulations confirm that these signals are due to an oblique two-stream filamentation instability. These findings provide new insight into ultra-fast instability and heating processes in solids under extreme conditions at the nanometer level with possible implications for laser particle acceleration, inertial confinement fusion, and laboratory astrophysics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

Spiers Memorial Lecture: activating metal sites for biological electron transfer

Metal sites in biology often exhibit unique spectroscopic features that reflect novel geometric and electronic structures imposed by the protein that are key to reactivity. The blue copper active site involved in long range, rapid biological electron transfer is a classic example. This review presents an overview of both traditional and synchrotron based spectroscopic methods and their coupling to electronic structure calculations to understand the unique features of the blue copper active site, their contributions to function and the role of the protein in determining the geometric and electronic structure of the active site (called the “entatic state”). The relation of this active site to other biological electron transfer sites is further developed. Specifically, ultrafast XFEL spectroscopy is used to evaluate the methionine–S–Fe bond in cytochrome c, and its entatic control by the protein in determining function (electron transfer vs. apoptosis).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

dCache CI/CD migration to Kubernetes

For over two decades, the dCache project has provided open-source to satisfy ever-more demanding storage requirements. More than 80 sites worldwide rely on dCache to provide services for LHC experiments, Belle-II, Eu- XFEL, and others. This can be achieved only with a well-established process from a whiteboard, where ideas are created through development, packaging, and testing. The project’s build and test infrastructure is based on Jenkins CI and a set of virtual machines. This infrastructure is maintained by dCache developers. With the introduction of the DESY-central Gitlab server, the developers have started migrating from VM-based testing to container-based deployments in the onsite Kubernetes cluster. As a result, we have packaged dCache containers and Helm charts that can be used by other sites to reproduce our test and build steps quickly or to evaluate new releases on their pre-production systems and, eventually, become a standard model of dCache deployment at the sites. This paper describes the challenges we have faced, the techniques we used to solve them, and the issues that still need to be addressed.

Mkrtchyan, Tigran [DESY]↗

Non-thermal structural transformation of diamond driven by x-rays

Intense x-ray pulses can cause the non-thermal structural transformation of diamond. At the SACLA XFEL facility, pump x-ray pulses triggered this phase transition, and probe x-ray pulses produced diffraction patterns. Time delays were observed from 0 to 250 fs, and the x-ray dose varied from 0.9 to 8.0 eV/atom. The intensity of the (111), (220), and (311) diffraction peaks decreased with time, indicating a disordering of the crystal lattice. From a Debye–Waller analysis, the rms atomic displacements perpendicular to the (111) planes were observed to be significantly larger than those perpendicular to the (220) or (311) planes. At a long time delay of 33 ms, graphite (002) diffraction indicates that graphitization did occur above a threshold dose of 1.2 eV/atom. These experimental results are in qualitative agreement with XTANT+ simulations using a hybrid model based on density-functional tight-binding molecular dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-shot in-line x-ray phase-contrast imaging of void-shockwave interactions in fusion energy materials

Recent breakthroughs in nuclear fusion, specifically the report of reactions exceeding scientific breakeven at the National Ignition Facility (NIF), highlight the potential of inertial fusion energy (IFE) as a sustainable and virtually limitless energy source. However, further progress in IFE requires characterization of defects in ablator materials and how they affect fuel capsule compression. Voids within the ablator can degrade energy yield, but their impact on the density distribution has primarily been studied through simulations, with limited high-resolution experimental validation. To address this, we used the x-ray free-electron laser (XFEL) at the matter in extreme conditions (MECs) instrument at the Linac coherent light source (LCLS) to capture 2D x-ray phase-contrast (XPC) images of a void-bearing sample with a composition similar to inertial confinement fusion (ICF) ablators. By driving a compressive shockwave through the sample using MEC's long-pulse laser system, we analyzed how voids influence shockwave propagation and density distribution during compression. To quantify this impact, we extracted phase information using two phase retrieval algorithms. First, we applied the contrast transfer function (CTF) method, paired with Tikhonov regularization and a fast optimization approach to generate an initial phase estimate. We then refined the result using a projected gradient descent (PGD) method that works directly with the sample's refractive index. Comparing these results with radiation adaptive grid Eulerian (xRAGE) radiation hydrodynamic simulations enables identification of model validation needs or improvements. By calculating phase maps in situ, it becomes possible to reconstruct areal density maps, improving understanding of laser-capsule interactions and advancing IFE research.

Hodge, D. S. [Colorado State Univ., Fort Collins, ↗

Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. Here, we also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

angle metrology↗

X-ray circular dichroism measured by cross-polarization x-ray transient grating

Measuring natural circular dichroism in the x-ray regime to extract stereochemical information from chiral molecules in solution remains a challenge. This is primarily due to technical limitations of the existing synchrotron sources, which hinder access to measurements of local chirality by exploiting core hole electronic transitions. In response to this challenge, we propose an alternative approach: utilizing XFEL-based cross-polarization x-ray transient grating (XTG). This method provides an indirect means to measure x-ray circular dichroism (XCD). Notably, our findings reveal that the signal emerges only once the excited cores have undergone dephasing through relaxation. XTG is now routinely measured in the XUV regime and has recently been made available for hard x-rays. Free electron lasers now offer polarization controls, and XTG can be extended to various polarization states for the two pump beams, making XCD measured by XTG feasible with the current state-of-the-art technology.

74 ATOMIC AND MOLECULAR PHYSICS↗

Advances in Nb 3 Sn superconducting radiofrequency cavities towards first practical accelerator applications

Abstract Nb 3 Sn is a promising next-generation material for superconducting radiofrequency cavities, with significant potential for both large scale and compact accelerator applications. However, so far, Nb 3 Sn cavities have been limited to continuous wave accelerating fields <18 MV m −1 . In this paper, new results are presented with significantly higher fields, as high as 24 MV m −1 in single cell cavities. Results are also presented from the first ever Nb 3 Sn-coated 1.3 GHz 9-cell cavity, a full-scale demonstration on the cavity type used in production for the European XFEL and LCLS-II. Results are presented together with heat dissipation curves to emphasize the potential for industrial accelerator applications using cryocooler-based cooling systems. The cavities studied have an atypical shiny visual appearance, and microscopy studies of witness samples reveal significantly reduced surface roughness and smaller film thickness compared to typical Nb 3 Sn films for superconducting cavities. Possible mechanisms for increased maximum field are discussed as well as implications for physics of RF superconductivity in the low coherence length regime. Outlook for continued development is presented.

43 PARTICLE ACCELERATORS↗

Ultra-fast transverse beam orbit control in LCLS copper linac. Part I

We report current and future experiments at LCLS require x-ray pulse trains of variable time separation on the nanosecond scale. For instance, the cavity-based XFEL (CBXFEL) will use up to 4 pulses separated by 218.5 ns, the X-ray Laser Oscillator (XLO) will use 15 to 25 ns spaced pulses, and the Matter under Extreme Conditions (MEC) experiments use pulse trains separated by 5 nanoseconds or less. In this paper, we demonstrate an ultra-fast e-beam trajectory control method based on transverse electro-magnetic (TEM) striplines and state-of-the-art power sources, to enhance LCLS operations in these regimes.

47 OTHER INSTRUMENTATION↗

A high repetition rate millimeter wavelength accelerator for an X-ray free-electron laser

A compact collinear wakefield accelerator has been designed for an X-ray free-electron laser capable of operating at a pulse repetition rate in the tens of kilohertz. The maximum achievable accelerating gradient has been determined, with its limitation linked to beam breakup instability. The fabrication techniques for the principal components of the accelerator including wakefield generation, couplers for excess power extraction and diagnostics, focusing quadrupoles, and a novel undulator have been discussed. Results from various laboratory and beam-based tests on these components have been compared to their original design specifications and demonstrated very good agreement. A preliminary design for the XFEL has been presented, featuring a novel small-period, force-neutral, adjustable-phase undulator.

26 undulator↗

Two-electron interference in two-photon attosecond double ionization of neon

The pump-probe experiments enabled by x-ray free-electron lasers (XFEL) will allow us to directly observe correlated electronic motion with attosecond time resolution by detecting photoelectron pairs in coincidence. In helium, the transition between the nonsequential and sequential regime in two-photon double ionization (TPDI) is well explained by a virtual-sequential model. Much less is known, however, about the TPDI process in more complex atoms. Recently, we extended the virtual-sequential model to arbitrary light pulses [Chattopadhyay Phys. Rev. A 108, 013114 (2023)]. This extension employs multichannel scattering states for the single ionization of both the neutral and the ionized target, which we initially applied to helium. In the present study, we show that our extended virtual-sequential model reproduces the qualitative features of the angularly integrated observables with available experimental results for neon, a considerably more complex target. We observe an intriguing feature of inverted two-particle interference in the joint-energy distribution of Ne compared to He. Finally, this phenomenon, attributable to the presence of a final doubly ionized state with triplet symmetry coupled to the two photoelectrons, should be observable with current experimental technologies.

74 ATOMIC AND MOLECULAR PHYSICS↗