Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Solar domestic hot water system installed at Texas City, Texas

This is the final technical report of the solar energy system located at LaQuinta Motor Inn, Texas City, Texas. The system was designed to supply 63 percent of the total hot water load for a new 98 unit motor inn. The solar energy system consists of a 2100 square feet Raypack liquid flat plate collector subsystem and a 2500 gallon storage subsystem circulating hot water producing 3.67 x 10 to the 8th power Btu/year. Abstracts from the site files, specification references, drawings, installation, operation, and maintenance instructions are included.

Source record↗

Solar heating and hot water system installed at Southeast of Saline, Unified School District 306, Mentor, Kansas

The solar system, installed in a new building, was designed to provide 52 percent of the estimated annual space heating load and 84 percent of the estimated annual potable hot water requirement. The liquid flat plate collectors are ground-mounted and cover a total area of 5125 square feet. The system will provide supplemental heat for the school's closed-loop water-to-air heat pump system and domestic hot water. The storage medium is water inside steel tanks with a capacity of 11,828 gallons for space heating and 1,600 gallons for domestic hot water. The solar heating facility is described and drawings are presented of the completed system which was declared operational in September 1978, and has functioned successfully since.

Source record↗

Solar hot water system installed at Day's Inn Motel, Dallas, Texas (Valley View)

The solar system was designed to provide 65 percent of the total domestic hot water (DHW) demand. A liquid (water) flat plate collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank when the solar pump is not running. Heat is transferred from the DHW tanks through a shell and tube heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up standby losses. All pumps are controlled by differential temperature controllers.

Source record↗

ReaxFF molecular dynamics simulations of electrolyte–water systems at supercritical temperature

We have performed ReaxFF molecular dynamics simulations of alkali metal–chlorine pairs in different water densities at supercritical temperature (700 K) to elucidate the structural and dynamical properties of the system. The radial distribution function and the angular distribution function explain the inter-ionic structural and orientational arrangements of atoms during the simulation. The coordination number of water molecules in the solvation shell of ions increases with an increase in the radius of ions. We find that the self-diffusion coefficient of metal ions increases with a decrease in density under supercritical conditions due to the formation of voids within the system. The hydrogen bond dynamics has been interpreted by the residence time distribution of various ions, which shows Li+ having the highest water retaining capability. The void distribution within the system has been analyzed by using the Voronoi polyhedra algorithm providing an estimation of void formation within the system at high temperatures. We observe the formation of salt clusters of Na+ and K+ at low densities due to the loss of dielectric constants of ions. The diffusion of ions gets altered dramatically due to the formation of voids and nucleation of ions in the system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solar heating and domestic hot water system installed at Kansas City, Fire Stations, Kansas City, Missouri

The solar system was designed to provide 47 percent of the space heating, 8,800 square feet area and 75 percent of the domestic hot water (DHW) load. The solar system consists of 2,808 square feet of Solaron, model 2001, air, flat plate collector subsystem, a concrete box storage subsystem which contains 1,428 cubic feet of 0.5 inch diameter pebbles weighing 71.5 tons, a DHW preheat tank, blowers, pumps, heat exchangers, air ducting, controls and associated plumbing. Two 120 gallon electric DHW heaters supply domestic hot water which is preheated by the solar system. Auxiliary space heating is provided by three electric heat pumps with electric resistance heaters and four 30 kilowatt electric unit heaters. There are six modes of system operation.

Source record↗

Nitrous oxide in fresh water systems: An estimate for the yield of atmospheric N2O associated with disposal of human waste

The N2O content of waters in the Potomac and Merrimack Rivers was measured on a number of occasions over the period April to July 1977. The concentrations of dissolved N2O exceeded those which would apply in equilibrium with air by factors ranging from about 46 in the Potomac to 1.2 in the Merrimack. Highest concentrations of dissolved N2O were associated with sewage discharges from the vicinity of Washington, D. C., and analysis indicates a relatively high yield, 1.3 to 11%, for prompt conversion of waste nitrogen to N2O. Measurements of dissolved N2O in fresh water ponds near Boston demonstrated that aquatic systems provide both strong sources and sinks for atmospheric N2O.

Kaplan, W. A.↗

Preliminary Testing of Electrolytic Silver Ion Generation for Spacecraft Potable Water Systems

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of imparting biocidal silver into potable water on exploration spacecraft. This method of water disinfection is used commercially in hospitals and marine vessels, but the spacecraft application poses unique challenges such as low water conductivity, increased importance of electrode longevity, and an interface with other systems that may be sensitive to any particles released in the electrolysis process. Testing has shown that due to the low conductivity of the water, the electroactive area of the cell can be scaled linearly to achieve a target electrolysis current despite the general non-linearity of electrochemical systems. More importantly, however, the low conductivity dictates that a large electroactive area and minimal electrode gap be employed in the design. Furthermore, thermodynamic considerations suggest that a low applied voltage is necessary to avoid undesired electrode reactions that could negatively impact long-term performance. Preliminary testing of long-term electrode health suggests that anodic oxide formation may not present as significant a challenge as anticipated; however, further testing in a system closed to the atmosphere is required to rule out the influence of atmospheric CO2 on the pH of the process water. Comparison of filtered and unfiltered silver concentration measurements indicates that release of particles larger than 0.2 μm was negligible in this preliminary test. A test article has been developed to facilitate further testing of silver electrolysis, which continues to be a candidate technology for spacecraft potable water disinfection.

silver↗

Solar heating, cooling, and domestic hot water system installed at Kaw Valley State Bank and Trust Company, Topeka, Kansas

The building has approximately 5600 square feet of conditioned space. Solar energy was used for space heating, space cooling, and preheating domestic hot water (DHW). The solar energy system had an array of evacuated tube-type collectors with an area of 1068 square feet. A 50/50 solution of ethylene glycol and water was the transfer medium that delivered solar energy to a tube-in-shell heat exchanger that in turn delivered solar heated water to a 1100 gallon pressurized hot water storage tank. When solar energy was insufficient to satisfy the space heating and/or cooling demand, a natural gas-fired boiler provided auxiliary energy to the fan coil loops and/or the absorption chillers. Extracts from the site files, specification references, drawings, and installation, operation and maintenance instructions are presented.

Source record↗

Solar hot water system installed at Day's Inn Motel, Savannah, Georgia

The Solar System was designed to provide 50 percent of the total Domestic Hot Water (DHW) demand. Liquid Flat Plate Collectors (900 square feet) are used for the collector subsystem. The collector subsystem is closed loop, using 50 percent Ethylene Glycol solution antifreeze for freeze protection. The 1,000 gallon fiber glass storage tank contains two heat exchangers. One of the heat exchangers heats the storage tank with the collector solar energy. The other heat exchanger preheats the cold supply water as it passes through on the way to the Domestic Hot Water (DHW) tank heaters. Electrical energy supplements the solar energy for the DHW. The Collector Mounting System utilizes guy wires to structurally tie the collector array to the building.

Source record↗

Ultrapure Water System at JSC for High Purity Cleaning of Flight Hardware, Astromaterial Handling Tools and Solar Wind Samples

Use of Ultrapure Water (UPW) for cleaning of astromaterial sample handling tools and containers was driven by the discontinuation of Freon 113 as a cleaning solvent, due to environmental concerns. Freon 113, recycled using distillation, was very effective at removing organic residues from sample handling hardware. The initial switch to high purity water for astromaterial tool cleaning was modeled after efforts at White Sands Test Facility (WSTF) and current semiconductor UPW production practices in the early 1990s. JSC curation’s first system was comprised of ion exchange polishing cylinders, 55 gallon PVDF-lined storage tank, a few tens of feet of PVDF piping, UV and particle filtration, and this system supported cleaning for lunar, meteorite and Cosmic Dust collectors lab operations. By 2000 a major expansion and upgrade was providing UPW of quality E-1 (ASTM D5127-90) or better at 10 gpm for cleaning of the Genesis solar wind payload for flight, in addition to sample handling tools for other astromaterials. This expansion included a 1000 gallon storage tank and several hundred feet of PVDF piping located in B. 31 and 31N. An extra reverse osmosis process unit was added to incoming water in 2005. Subsequently several major components were replaced, and in anticipation of adding new labs, an enlarged UPW system was designed in 2018 and completed in 2019. This system produces grade E1.1 UPW at 15 gpm in a continuous 1100 ft. loop with 5000 gal. storage tank, supplying 8 laboratories.

Ultrapure water↗

Irreversible Wash Aid Additive for Cesium Mitigation: Phase II. Selection and/or Modification of COTS Field Portable Waste Water Systems

After an accidental or malicious release of radioactivity, large urban areas may be contaminated, compromising response efforts by first responders and law enforcement officials. In addition, some public services (e.g., drinking water and wastewater treatment, electrical power distribution, etc.) may be disrupted. In such an event, it may be important to deploy mitigation efforts in certain areas to restore response activities and public services (Fig. S-1). This report explores the state-of-the-art approach for a system to rapidly return critical infrastructure components to service following a cesium-137 (Cs-137) radiological dispersal device (RDD) release while avoiding the spread of Cs-137 beyond its original deposition area and minimizing the amount of Cs-137-contaminated wastewater. Specifically, we describe a wash system consisting of chemical additives added to fire hydrant water and irreversible solid sequestering agents added as the water is collected and treated for recycle in situ. The wash system is intended to be a rapidly deployable, cost-effective means of mitigating an urban setting for the purpose of restoring critical infrastructure and operational activities after a radiological release.

61 RADIATION PROTECTION AND DOSIMETRY↗

Survey on the micro-pollutants presence in surface water system of northern Serbia and environmental and health risk assessment

Highlights: • First survey on the occurrence of 940 substances in the middle part of the Danube Basin. • Micro-pollutants from canals water had higher abundance of contaminants that from river. • High level of sterols indicated dominant effect of untreated domestic wastewater. • Correlations among the groups of micro-pollutants indicated their common origin. • Ecological risk suggesting a potential for adverse effects on fish. This study demonstrates the occurrence of 940 organic micro-pollutants in surface water of four rivers, one irrigation canal system, and two lakes in Vojvodina Province, the northern part of Serbia, summing in total eighteen samples. The number of detected chemicals ranged from 22 to 84, with 127 micro-pollutants detected at least once, representing 13% of the studied substances. The targeted compounds include n-alkanes, sterols, polycyclic aromatic hydrocarbons (PAHs), organochlorine pesticides polychlorinated biphenyls, pesticides, pharmaceutical active compounds, industrial chemicals, plasticizers, etc. Among the analysed compounds, sterols were the most dominant with maximum quantified concentrations. The substances which were quantified with frequency over 50% were two PAHs (2-methylnaphthalene, benzo(ghi)perylene), five sterols (cholesterol, cholestanol, stigmasterol, fucosterol, beta-sitosterol), three pharmaceuticals and personal care products (L-menthol, diethyltoluamide, caffeine), and ten household chemicals (4-tert-octylphenol, dimethyl phthalate, methyl palmitate, phenylethyl alcohol, 1-nonanol, alpha-terpineol, 2-phenoxy-ethanol, methyl myristate, acetophenone, and 2-ethyl-1-hexanol). The list of priority substances under the European Union Directive 2013/39/EU includes 49 priority substances (PSs) out of which 34 were analysed. Among these, eleven PSs were quantified, and only two compounds (fluoranthene and benzo (a) pyrene) exceeded EU Environmental Quality Standards targeted values. The obtained results were compared with the previously published data that dealt with the same targeted number of micro-pollutants in sediment samples. This revealed connections between the same sampling locations. Environmental risk assessment showed the existence of potential ecological risk as 72% of the obtained values for the ecological hazard index (HI) at investigated locations were higher that the targeted value (HI > 1). Estimated values for hazard quotient (HQ) and hazard index (HI) for non-carcinogenic risk were lower than the targeted value, indicating no non-carcinogenic risk through dermal contact and non-intentional ingestion of water. Estimated values for cancer risk were all below 1 × 10{sup −6}, which is not considered to pose significant human health risk.

54 ENVIRONMENTAL SCIENCES↗

Availability and redundancy design considerations for Electron-Ion Collider cooling water systems and components

The Electron-Ion Collider (EIC) is composed of several large-scale systems, which all require highly available cooling systems based on the Conceptual Design Report. Since the overall EIC availability goal is 85%, all the subsystems will contribute. Availability is defined by the time that a component or system is functional given a required or scheduled run time. The focus of the project was to determine if redundant or extra cooling water and deionized water pumps were needed in a subsystem to increase the overall EIC availability. The largest subsystem in the ring is the 10 o’clock cooling system, so this was used for redundancy analysis. Relationships between the components were defined as parallel, series, or m-out-of-n for the cooling towers, valves, pumps and heat exchangers to perform calculations. A comparison between an original system versus a redundant one was then done using component availability from industry standards. Cost analysis was also performed to see how much the availability and cost would decrease if the redundancy application was not chosen. The Collider-Accelerator Department (CAD) also has a calculation in place for the Relativistic-Heavy Ion Collider (RHIC), so cooling water failure data was collected from their operational log and analyzed for real-life component availability. A comparison of component availability from the CAD data to the industry standards was made through the 10 o’clock cooling system layout. The results showed that the subsystems need to have over a 98% availability for an 85% goal, and that the CAD data is very close to the industry component standards. The cost differential is miniscule compared to the potential availability increase. Therefore, redundant systems can increase the overall EIC availability by a sizable amount and are worth implementing.

43 PARTICLE ACCELERATORS↗

BioMoSS: Biocidal MoS2 for Disinfection of Spacecraft Potable Water Systems

It has been reported in the literature that few-layered, vertically-aligned molybdenum disulfide (FLV-MoS2) can produce biocidal agents for water disinfection with great effectiveness under visible light excitation. The nano-structure, with limited layers and small domain size increases the band gap of the MoS2 in the visible region such that visible light can be used to drive the production of reactive oxygen species (ROS) for biocidal control. This paper will present the BioMoSS (biocidal MoS2) for space applications concept and present initial results of the investigation into turning the FLV-MoS2 into a viable biocidal system.

Delzeit, Lance↗

Advancing Asset Management in Water Infrastructure Systems

Aging water system infrastructure, including drinking water, wastewater, and stormwater, poses a growing challenge for utilities and municipalities. These water systems have well documented challenges with respect to their age, condition, and level of service. ASCE annual report cards consistently rate these infrastructure systems in the United States as underfunded, overcapacity, or past service life (ASCE 2025 Report Card). For example, Chini and Stillwell (2017) estimated that the mean water loss in drinking water systems, i.e., non-revenue water, is approximately 16% across the United States. These concerns are not just relegated to the United States, with Courtenay, British Columbia, identifying 17% of their water main pipes as in a ‘poor’ condition state, defined as a category condition 5 out of 5 (City of Courtenay, 2024). These cases illustrate the challenges utilities are facing to manage extensive networks of infrastructure to deliver a consistent and high level of service. For buried infrastructure such as water systems, studies suggest that preventative interventions can lead to lower maintenance costs and fewer service disruptions (Mazumder et al, 2018; Li et al, 2014). The demonstrated need and benefit of appropriately applied asset management is juxtaposed against the relatively sparse literature that evaluates water systems within an asset management construct. Since 2020, just 37 papers specifically reference asset management in the Journal of Water Resources Planning and Management. Of those, only a few specifically look to develop strategies for improved asset management. Therefore, we highlight four key research areas that represent opportunities for advancement of asset management research for water systems. First, advances in condition assessment and forecasting are needed to better estimate asset deterioration using diverse datasets. Second, machine learning (ML) and artificial intelligence (AI) hold promise for predictive maintenance and investment prioritization, though questions of generalizability and model transparency remain. Third, applying a value of information framework can guide utilities in making cost-effective sensor deployment and data collection decisions, to direct monitoring strategies towards data-informed asset management decisions. Finally, integrated infrastructure management is critical, requiring coordinated planning with other infrastructure systems and stakeholder engagement to reduce costs and enhance service delivery.

Chini, Christopher M.↗

Economic evaluation of a solar hot-water-system

Analysis shows economic benefits at six representative sites using actual data from Tempe, Arizona and San Diego, California installations. Model is two-tank cascade water heater with flat-plate collector array for single-family residences. Performances are forecast for Albuquerque, New Mexico; Fort Worth, Texas; Madison, Wisconsin; and Washington, D.C. Costs are compared to net energy savings using variables for each site's environmental conditions, loads, fuel costs, and other economic factors; uncertainty analysis is included.

Source record↗

Draining and drying process development of the Tokamak Cooling Water System of ITER

The ITER Organization (IO) developed a thermal-hydraulic (TH) model of the complex first wall and blanket (FW/BLK) cooling channels to determine gas flow rate and pressure required to effectively blow out the water in the FW/BLK. In addition, US ITER conducted experiments for selected geometries of FW/BLK flow channels to predict the blowout parameters. The analysis indicates that as low as 2 MPa of pressure difference over the blanket modules will ensure substantial evacuation of the water in blankets with just a few percent remaining in the blanket flow channels. A limited validation study indicates that the analysis yields less conservative results to compare against data collected from experiments. Therefore, the designed blow out flow of the drying system was selected with a large margin above the measured values to ensure the blow out operation.

Kim, Seokho H.↗