Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Laser-induced fluorescence measurements of ion fluctuations in electron and ion presheaths

Electrostatic flow-driven instabilities have been predicted in the presheath region of low-temperature plasmas for both ion and electron rich sheaths. The ion-acoustic fluctuations that arise from these instabilities can influence transport through an enhanced collision rate. In this work, ion fluctuation spectra were measured using laser-induced fluorescence (LIF) in the presheath region for both sheath polarities. Furthermore, the non-invasive nature of LIF compared to that of probes is particularly valuable for these measurements because the sheath and presheath around a probe may generate their own flow-driven instabilities, which obscure the measurement. Measurements were made using a recently implemented field programmable gate array-based system able to measure ion fluctuation spectra up to 1 MHz using a two-point correlation function technique. Narrow bandwidth ion fluctuations were observed near 0:46 f pi (460 kHz) for both sheath polarities, where f pi is the ion plasma frequency. The observed fluctuations were significantly stronger in the electron sheath case and were observed over a larger volume of plasma. Fluctuations were measured in the ion sheath case at locations far enough from the sheath that linear theory predicts stability, suggesting that ion-acoustic instabilities generated in the relatively small unstable region near the boundary reflect from the sheath and perturb a much larger volume of the plasma. This is expected to affect probes with both ion and electron rich sheaths, meaning any dc biased probe may effectively act as an ion-acoustic wave antenna. These measurements are consistent with the recent theory and particle-in-cell results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual design and performance predictions for 2D beam emission spectroscopy turbulence measurements at Wendelstein 7-X

A conceptual design for a 2D beam emission spectroscopy diagnostic system to measure ion gyro-scale plasma turbulence at Wendeslstein 7-X is described. The conceptual design identifies field-aligned viewing geometries and ports for cross-field turbulence measurements in the neutral beam volume. A 2D sightline grid covers the outer plasma region, and the grid configuration provides sufficient k-space coverage in radial and poloidal directions for ion temperature gradient and trapped-electron mode turbulence measurements. Emission intensity estimates, optical transmission losses, and detector noise levels indicate that the measurements will be sensitive to plasma density fluctuations as small as δn/n ≈ 0.5% with a bandwidth of 1 MHz. Implementation challenges include a small beam emission Doppler shift due to nearly radial heating beams and reduced optical throughput due to collection aperture limitations.

47 OTHER INSTRUMENTATION↗

Electronic transport, thermal transport, thermal expansion, and magnetization in the strongly correlated metal LaNi⁢O 3

Perovskite structured LaNiO 3 is a strongly correlated metal with intriguing thermal and magnetic properties. The volume dependence of calculated and measured physical properties can add additional critical information to develop a more in-depth understanding of this strongly correlated phenomenon. Taking advantage of recent single crystal LaNiO 3 growth using the floating-zone method, we have measured the thermal expansion, the magnetostriction, and the pressure dependence of the magnetic susceptibility, which then allows derivation of the Grüneisen parameters γ e = $\frac{dlnN(E_F)}{d lnV}$, γ χ = $\frac{dlnχ}{d lnV}$, as well as of electric and thermal transport properties. We simulate the volume dependence of structural and magnetic properties using Density Functional Theory calculations at the Generalized Gradient Approximation level. A large discrepancy between experimental values and calculated ones suggests that strong correlations are likely to be dynamic in nature. This study also provides a side-by-side comparison of measurements in single crystal and polycrystalline samples of LaNiO 3 to elucidate intrinsic materials properties. A broad hump at high temperatures in the temperature dependence of magnetization found in the single crystal sample of LaNiO 3 has been rationalized by a model that includes the influence of electron correlations on the Landau diamagnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superiority of compensatory reserve measurement compared with the Shock index for early and accurate detection of reduced central blood volume status

Shock index (SI) equals the ratio of heart rate (HR) to systolic blood pressure (SBP) with clinical evidence that it is more sensitive for trauma patient status assessment and prediction of outcome compared with either HR or SBP alone. We used lower body negative pressure (LBNP) as a human model of central hypovolemia and compensatory reserve measurement (CRM) validated for accurate tracking of reduced central blood volume to test the hypotheses that SI: (1) presents a late signal of central blood volume status; (2) displays poor sensitivity and specificity for predicting the onset of hemodynamic decompensation; and (3) cannot identify individuals at greatest risk for the onset of circulatory shock. We measured HR, SBP, and CRM in 172 human subjects (19–55 years) during progressive LBNP designed to determine tolerance to central hypovolemia as a model of hemorrhage. Subjects were subsequently divided into those with high tolerance (HT) (n = 118) and low tolerance (LT) (n = 54) based on completion of 60 mm Hg LBNP. The time course relationship between SI and CRM was determined and receiver operating characteristic (ROC) area under the curve (AUC) was calculated for sensitivity and specificity of CRM and SI to predict hemodynamic decompensation using clinically defined thresholds of 40% for CRM and 0.9 for SI. The time and level of LBNP required to reach a SI = 0.9 (~60 mm Hg LBNP) was significantly greater (p < 0.001) compared with CRM that reached 40% at ~40 mm Hg LBNP. Shock index did not differ between HT and LT subjects at 45 mm Hg LBNP levels. ROC AUC for CRM was 0.95 (95% CI = 0.94–0.97) compared with 0.91 (0.89–0.94) for SI (p = 0.0002). Despite high sensitivity and specificity, SI delays time to detect reductions in central blood volume with failure to distinguish individuals with varying tolerances to central hypovolemia.

60 APPLIED LIFE SCIENCES↗

Alteration in micro-mechanical characteristics of wellbore cement fracture surfaces due to fluid exposure

The stiffness of wellbore cement fracture surfaces was measured after exposing to the advective flow of nitrogen, silicone oil, and medium sweet dead crude oil for different exposure periods. The test specimens were extracted from fractured cement cylinders, where the cement fracture surfaces were exposed to the different fluids up to 15 weeks. A nanoindenter with a Berkovich indenter tip was used to measure load-indentation depth data, which was used to extract the elastic modulus (E) and nano-hardness (H) of the cement fracture surfaces. A reduction in the elastic modulus compared with an unexposed specimen were observed in all the specimens. Both elastic modulus and nano-hardness for the specimens exposed to silicone oil were lower than specimens exposed to nitrogen gas and varied with the period of exposure. The elastic modulus and nano-hardness of the specimens exposed to crude oil were the lowest with a significant decrement with the exposure period. The frequency distribution of the nanoindentation measurements shows that the volume-fraction ratio of the two types of cement hydrated nanocomposites for both the unexposed and test specimens is about 70:30%. Phase transformation beneath the indenter is observed for all of the specimens, with more obvious plastic deformation in specimens exposed to crude oil. Analytical measurements (SEM, EDS, FT-IR, and XRD) on exposed cement fracture surfaces reveal different levels of physical and chemical alteration that are consistent with the reduction in stiffness measured by nanoindentation. Furthermore, the study suggests that cement stiffness will decrease due to crude oil exposure, and the fracture will be sensitive to stress and pore pressure with time.

42 ENGINEERING↗

Accurate measurement of porosity size and morphology in aluminium alloy laser welds

Conventional two-dimensional optical microscopy is the most common tool for capturing and quantifying keyhole collapse porosity and other defects formed during the laser welding of aluminium alloys. This approach is of limited utility since only a single longitudinal or transverse metallographic cross-section, comprising only a small fraction of the overall weld volume, can be extracted or analysed at a time. X-ray computed tomography tools, on the other hand, enable three-dimensional visualisation and analysis of porosity and defects to be made across the full weld volume. When comparing these two measurement techniques, two-dimensional microscopy tools significantly underestimated the fraction of defects present within the weld at levels between 50% and 80%. Three-dimensional x-ray computed tomography tools also provide a means for accurately characterising the location, size and morphology of irregularly shaped defects. By categorising the defect shapes using a Zingg's shape analysis, in which the distribution of defect morphologies could be quantified as disk, rod and spherical shapes, a transition in defect morphology moving from stationary beam to oscillating beam welds was detected and quantified.

36 MATERIALS SCIENCE↗

Polymer Retention Evaluation in a Heavy Oil Sand for a Polymer Flooding Application on Alaska’s North Slope

For a polymer flooding field trial in a heavy oil reservoir on Alaska’s North Slope, polymer retention is a key parameter. Because of the economic impact of retention, this parameter was extensively studied using field core material and conditions. Several important findings were noted. Polymer retention based on effluent viscosity measurements can be overestimated unless the correct (non-linear) relation between polymer concentration and viscosity is used. Polymer degradation (either mechanical or oxidative) can also lead viscosity-based measurements to overestimate retention. Inaccessible pore volume (IAPV) can be overestimated if insufficient brine is flushed through the sand between polymer banks. Around 100 pore volumes (PV) of brine may be needed to displace mobile polymer to approach a true residual resistance factor and properly measure IAPV. Even for a sand pack with kwsor = 20 mD, IAPV was zero for HPAM with molecular weight (Mw) of 18 million g/mol. Fine-grain particles (<20 μm) strongly impacted polymer retention values. Native NB#1 sand with a significant component of particles <20 μm exhibited 290 μg/g, while the same sand exhibited 28 μg/g after these small particles were removed. Polymer retention did not necessarily correlate with mineral composition. The NB#1, NB#3, and OA sands had similar elemental and clay compositions, but the NB#1 sand exhibited ~10 times higher retention than the NB#3 sand. Polymer retention did not necessarily correlate with permeability. NB#1 sand exhibited much higher retention than OA sand, even though NB#1 sand was twice as permeable as OA sand. No evidence of chromatographic separation of HPAM molecular weights was found in our experiments. Although retention tended to be greater without a residual oil saturation (than at Sor), the effect was not strong. Aging a core (with high oil saturation) at 60°C reduced HPAM retention by a factor of two. As expected, under similar conditions, polymer retention was greater for a higher Mw HPAM (18 million g/mol) than for a lower Mw HPAM (10-12 million g/mol). In many cases with high polymer retention values (e.g., 240 μg/g), polymer arrival at the end of the core was relatively quick, but achieving the injected concentration occurred gradually over many pore volumes. This effect was not due chromatographic separation of polymer molecular weights. Results from modeling of this behavior was consistent with concentrationdependent polymer retention. The form assumed for the retention function in a simulator can have an important impact on the timing and magnitude of the oil response from a polymer flood. Field-based observations can underestimate polymer retention, depending on when the tracer and polymer concentrations were measured and the assumptions made about reservoir heterogeneity.

Wang, Dongmei↗

On the Development of Order and Interfaces during the Growth of Ultrathin La 2 CuO 4 Films by Molecular Beam Epitaxy

While the atomic structure of interfaces in complex oxide heterostructures created by epitaxial growth has been investigated extensively, few studies have been conducted on how interfaces form and restructure at the initial stage of film growth. The dynamic aspects of the growth behavior can strongly influence the final interfacial atomic structure, which may lead to the emergence of interface-specific properties, such as the rise of interfacial superconductivity between certain Ruddlesden-Popper oxide materials. In this report, the structural development of La2CuO 4 thin films grown by molecular beam epitaxy on a LaSrAlO 4 substrate is investigated by X-ray diffraction measurements with rapid scans over a volume of reciprocal space. This method provides far more detailed information on interface formation than traditional fixed-point measurements. The results show that the atomic structure of the interface becomes fully established after just a single unit cell of growth. Interestingly, restructuring continues to occur within the topmost half to one unit cell of the film during the deposition process. However, diffraction intensity oscillations from both reflection high-energy electron and X-ray measurements stabilize only after the growth of two unit cells, indicating that the growth front morphology continues to evolve until the start of the third unit cell. This multimodal investigation provides insights into the atomic processes taking place during layered oxide interface formation, including the dynamical rearrangement of LaO and CuO 2 layers. Such information is not only relevant to the engineering and optimization of functional layer structures but can also be critical for ultrathin films.

36 MATERIALS SCIENCE↗

Low fractional volume superconductivity in single crystals of Pr{sub 4}Ni{sub 3}O{sub 10} under pressure

Magnetotransport measurements of P⁢r4⁢N⁢i3⁢O10 single crystals performed under externally applied pressures up to 73 GPa in diamond anvil cells with either KBr or Nujol oil as pressure media yield signatures of superconductivity with a maximum onset temperature of approximately 31 K. True zero resistance was not observed, consistent with a nonpercolating superconducting volume fraction. Magnetization measurements provided corroborating evidence of superconductivity, with a pressure-dependent diamagnetic signal occurring below the onset temperature, and an estimate from the absolute value of the susceptibility suggests a superconducting volume fraction on the order of 10%. We observe sample to sample variations in the magnitude and pressure dependence of 𝑇𝑐 as well as a dependence on the configuration of electrical contacts on a given sample. Possible causes of this behavior may be significant inhomogeneities in the pressure and/or damage to the samples induced by the pressure media as well as inhomogeneities in the crystals themselves. The results imply that our as-grown P⁢r4⁢N⁢i3⁢O10 single crystals are not bulk superconductors but that there is a minority structure present within the crystals that is indeed superconductin

Chen, Xinglong↗

First Measurement of Antideuteron Number Fluctuations at Energies Available at the Large Hadron Collider

The first measurement of event-by-event antideuteron number fluctuations in high energy heavy-ion collisions is presented. The measurements are carried out at midrapidity (|η|<0.8) as a function of collision centrality in Pb-Pb collisions at $\sqrt{^sNN}$=5.02 TeV using the ALICE detector. A significant negative correlation between the produced antiprotons and antideuterons is observed in all collision centralities. The results are compared with a state-of-the-art coalescence calculation. While it describes the ratio of higher order cumulants of the antideuteron multiplicity distribution, it fails to describe quantitatively the magnitude of the correlation between antiproton and antideuteron production. On the other hand, thermal-statistical model calculations describe all the measured observables within uncertainties only for correlation volumes that are different with respect to those describing proton yields and a similar measurement of net-proton number fluctuations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optically detected NMR in a diamond-anvil cell for geochemistry

Developments in quantum-information processing are being adapted to perform nuclear-magnetic resonance (NMR) measurements on solutions in very small volumes. Here we describe efforts to adapt the technology to a diamond-anvil cell (DAC), with the goal of conducting solution NMR measurements at elevated pressures and temperatures. At the center of the method is the use of diamonds that have a particular type of defect that pairs a nitrogen atom substitution for near-surface carbon with a vacancy. These NV sites have unpaired electrons that can be excited while conserving electron spins and the amount of light released upon decay of the excited state depends upon the orientation of the electron spin. Under certain conditions the NV centers can probe AC magnetic fields from nearby nuclei with exquisite sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous real-time measurement of composition, flow, attenuation, density, and pipe-wallthickness in multiphase fluids

Apparatus (10) and methods for making simultaneous measurements of composition (water-cut), fluid flow, and sound attenuation in a multiphase fluid flowing (15) through a pipe (12) in real-time, using the same apparatus (10) are described. Additionally, the apparatus (10) provides real-time pipe wall thickness monitoring for observing pipe corrosion or internal deposition. Knowledge of wall thickness is necessary to correct for water-cut (oil-water composition) automatically by adjusting the liquid path length internal to the pipe (spool). The use of short duration frequency chirp excitation signals (24) enables the apparatus to provide information that can be used to extract multiple levels of information from the same measurement in multiphase fluids including the presence of a significant quantity of gas (˜60% gas volume fraction) in different flow regimes. Besides measuring steady flow, this device is useful for measurements during fast changing flows, such as for a rod-pumped well. Measurements up to about 1000 times a second can reliably be made.

Sinha, Dipen N.↗

Analysis of time-dependent strain heterogeneity in shales using X-ray microscopy and digital volume correlation

In this paper, we report the results of a 4-dimensional (3 spatial dimensions plus time) in-situ creep experiment on a milli-core shale plug from Barnett formation in Texas. An outstanding challenge in shale mechanics is connecting observable characteristics to predictable mechanical and hydraulic behavior. We employ novel imaging and analysis techniques to statistically link sample mineralogy and structure to observed deformation. In particular, we focus on mechanisms of porosity reduction during transient response to step changes in stress, analogous to the aseismic deformation that occurs after an episode of fracturing. Our main goal in this study is to take the first steps to visualize and capture the small-scale deformation mechanisms involved in creep of shales, using imaging techniques. To do so, we conducted a uniaxial creep experiment inside an Xradia Versa 520 micro-CT system for 12 h at room temperature under a constant uniaxial stress of 25 MPa. We employed a Digital Volume Correlation (DVC) method to measure micro-scale deforspmation of the sample by comparing the resulting volumetric images with a high-resolution scan of the sample obtained prior to the creep experiment. The results indicate that the time-dependent deformation in the compliant clay plus kerogen matrix constituents facilitates rigid grain rotation and compaction of intergranular porosity at the boundary between rigid grains and matrix.

58 GEOSCIENCES↗

Performance of Vehicle Fuel System Elastomers and Plastics with Test Fuels Representing Gasoline Blended with 10% Ethanol (E10) and 16% Isobutanol (iBu16)

The compatibilities of fuel system elastomers and plastics were evaluated for test fuels containing 16 vol.% isobutanol (iBu16) and 10 vol.% ethanol (E10). Elastomers included two fluorocarbons, four acrylonitrile butadiene rubbers (NBRs), and one type of fluorosilicone, neoprene, and epichlorohydrin/ethylene oxide. Plastic materials included four nylon grades, three polyamides, polytetrafluoroethylene (PTFE), polyvinylidene fluoride (PVDF), ethylene tetrafluoroethylene (ETFE), polyphenylene sulfide (PPS), high-density polyethylene (HDPE), polybutylene terephthalate (PBT), polyoxymethylene (POM), flexible polyvinylchloride (PVC), polyetherimide (PEI), polyetheretherketone (PEEK), and a phenol formaldehyde reinforced with glass fiber (GFPF). For each polymer material, the volume, mass, and hardness were measured before and after drying. Dynamic mechanical analysis (DMA) measurements were also performed on the dried specimens.For the elastomer materials the measured properties were similar for both fuels. The fluorocarbons and fluorosilicone swelled the least (~20%), while more moderate (20-45%) expansion occurred for the two NBR hose grades and (ECO). HNBR, neoprene, and silicone exhibited high swelling and softening, which likely precludes their use in many fuel systems. For the plastic materials, the observed swell was low; Nylon 11 swelled around 15%, but otherwise, their measured swell was <10%. Many of the plastics also showed sensitivity to alcohol type, as the E10 test fuel often imparted appreciably higher swell than iBu16. In general, the plastic materials showed good compatibility with the iBu16 and E10 test fuels. Here, the sole exception was the PVC material, which was structurally degraded from exposure to either fuel type. Compositional analysis showed high fuel retention in Nylon 12 and PVC. PVC also experienced a significant reduction in plasticizer compounds following exposure, which resulted in embrittlement and an increase in the glass-to-rubber transition temperature.

33 ADVANCED PROPULSION SYSTEMS↗

Simultaneous x-ray diffraction measurements of nine pressure calibrants to 140 GPa

Accurate pressure calibration is fundamental to quantitative high-pressure science, yet inconsistencies among widely used secondary pressure scales persist. In this work, we report simultaneous synchrotron x-ray diffraction meatogether in diamond anvil cells to 140 GPa. This simultaneous-measurement strategy minimizes transitive errors and run-to-run inconsistencies inherent to paired-measurement approaches, yielding direct experimental volume-volume (V-V) relations among the calibrants. These V-V relations link the compression state of each phase to that of every other phase measured in the same experiment. By anchoring these V-V relations to the reduced 300 K equation of state (EOS) of copper derived from ramp-compression measurements, we derive an internally consistent set of Cu-referenced pressure scales via Vinet EOS fits. Because the primary experimental result is the V-V dataset, it provides an EOS-independent constraint that can be rereferenced if primary standards are revised. The dataset further enables a direct experimental cross-check of consistency between the adopted reduced 300 K Cu EOS and the corresponding reduced 300 K ramp-derived EOSs for Pt, Au, Ta, and hcp-Fe under a fixed V-V constraint. The residuals quantify small, material-dependent mismatches between each phase EOS and the Cu reference EOS.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Burning velocities of R-32/O 2 /N 2 mixtures: Experimental measurements and development of a validated detailed chemical kinetic model

This work entails characterizing the flammability of the refrigerant R-32 (CH 2 F 2 ) by both experimental measurements and modeling. Burning velocities S u were measured using a constant-volume spherical-flame method for R-32/O2/N 2 mixtures with O 2 /N 2 ratios ranging from 21% (synthetic air) to 40%, pressures of (1 to 3) bar, and equivalence ratios $\phi$ of (0.8 to 1.3). Based on a critical assessment of available data, and extended by our own calculations, a detailed chemical kinetic model was developed and key reactions determined using reaction path and sensitivity analyses. Initiation and combustion were identified as distinct kinetic regimes and burning velocities were found to be controlled by two primary reactions: unimolecular decomposition of CH 2 F 2 → CHF + HF and the subsequent reaction, CHF + O 2 → CHFO + O, the latter reaction initiating the radical chain propagating and branching by producing O atoms. Sensitive rate constants in the kinetic model were critically adjusted within their uncertainties and current knowledge bounds to best fit the experimental burning velocities. We found that rate constants in the model could be adjusted to match a given experimental S u for specific conditions (O 2 loading, P, T, $\phi$). This, however, then fixes predicted burning velocities for other all conditions within (3 to 4)% if physically realistic rate parameters are maintained. Thus, the entire set of experimental data is fit, not just to particular conditions. Relative random uncertainties in the experimental Su measurements were (4 to 6)%, but assumptions made for thermal radiation lost by the burned gas in the spherical-flame experiments add an additional systematic uncertainty. Systematic differences between the limiting cases of adiabatic (no thermal radiation lost) and optically-thin (all thermal radiation lost) varied significantly with conditions and ranged from (4 to 30)% at high to low velocities, respectively, translating into uncertainties of (2 to 15)% considering the average of two limiting cases. Comparison of experimental and kinetically modeled Su values suggests that the burned gas tends towards the optically-thin limit at the lowest pressures and fuel loadings and toward the adiabatic limit at the highest pressures and loadings. We tested and found support for this conclusion with a detailed analysis as a function of all the conditions (T, P, % O 2 , $\phi$). This behavior appears to transition from optically-thin to adiabatic as the density of the initial fuel increases, which results in increased CO 2 in the burned gas and thus increased absorption of the thermal radiation (consistent with the Beer-Lambert Law). The validated detailed model based on evaluated kinetics is shown to accurately predict burning velocities for R-32 O 2 /N 2 mixtures over a wide range of conditions and provides a reliable basis for extrapolation to other conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal Pressure in the Laser‐Heated Diamond Anvil Cell: A Quantitative Study and Implications for the Density Versus Mineralogy Correlation of the Mantle

Abstract Thermal pressure is an inevitable thermodynamic consequence of heating a volumetrically constrained sample in the diamond anvil cell. Its possible influences on experimentally determined density‐mineralogy correlations are widely appreciated, yet the effect itself has never been experimentally measured. We present here the first quantitative measurements of the spatial distribution of thermal pressure in a laser‐heated diamond anvil cell (LHDAC) in both olivine and AgI. The observed thermal pressure is strongly localized and closely follows the distribution of the laser hotspot. The magnitude of the thermal pressure is of the order of the thermodynamic thermal pressure ( αK T Δ T ) with gradients between 0.5 and 1.0 GPa/10 μm. Remarkably, we measure a steep gradient in thermal pressure even in a sample that is heated close to its melting line. This generates consequences for pressure determinations in pressure‐volume‐temperature (PVT) equation of state measurements when using an LHDAC. We show that an incomplete account of thermal pressure in PVT experiments can lead to biases in the coveted depth versus mineralogy correlation. However, the ability to spatially resolve thermal pressure in an LHDAC opens avenues to measure difficult‐to‐constrain thermodynamic derivative properties, which are important for comprehensive thermodynamic descriptions of the interior of planets.

Yen, Connor Ethan↗

SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenna array, which surrounds a volume of tritium gas, to detect and measure the cyclotron radiation of the resulting β-decay electrons. To validate the feasibility of this method, Project 8 has designed a test stand to benchmark the performance of an antenna array at reconstructing signals that mimic those of genuine CRES events. To generate synthetic CRES events, a novel probe antenna has been developed, which emits radiation with characteristics similar to the cyclotron radiation produced by charged particles in magnetic fields. This paper outlines the design, construction, and characterization of this Synthetic Cyclotron Antenna (SYNCA). Furthermore, we perform a series of measurements that use the SYNCA to test the position reconstruction capabilities of the digital beamforming reconstruction technique. Finally, we find that the SYNCA produces radiation with characteristics closely matching those expected for cyclotron radiation and reproduces experimentally the phenomenology of digital beamforming simulations of true CRES signals.

47 OTHER INSTRUMENTATION↗