At least 217 records · Page 12

The fluid dynamic and shear environment in the NASA/JSC rotating-wall perfused-vessel bioreactor

The rotating-wall perfused-vessel (RWPV) bioreactor, used for both microgravity and Earth-based cell science experiments, is characterized in terms of the fluid dynamic and fluid shear stress environment. A numerical model of the flow field is developed and verified with laser Doppler velocimeter measurements. The effects of changes in operating conditions, including rotation rates and fluid perfusion rates, are investigated with the numerical model. The operating conditions typically used for ground-based experiments (equal rotation of the inner and outer cylinders) leads to flow patterns with relatively poor mass distribution characteristics. Approximately 50% of the inlet-perfused fluid bypasses the bulk of the fluid volume and flows to the perfusion exit. For operating conditions typical in microgravity, small differential rotation rates between the inner and outer cylinders lead to greatly improved flow distribution patterns and very low fluid shear stress levels over a large percentage of the fluid volume. Differences in flow patterns for the different operating conditions are explored. Large differences in the hydrodynamic environments for operating conditions typical of true microgravity and ground-based "microgravity simulations" are demonstrated.

Bioreactors↗

Femoral Blood Flow and Cardiac Output During Blood Flow Restricted Leg Press Exercise

Low load blood flow restricted resistance exercise (LBFR) causes muscle hypertrophy that may be stimulated by the local ischemic environment created by the cuff pressure. However, local blood flow (BF) during such exercise is not well understood. PURPOSE: To characterize femoral artery BF and cardiac output (CO) during leg press exercise (LP) performed at a high load (HL) and low load (LL) with different levels of cuff pressure. METHODS: Eleven subjects (men/women 4/7, age 31.4+/-12.8 y, weight 68.9+/-13.2 kg, mean+/-SD) performed 3 sets of supine left LP to fatigue with 90 s of rest in 4 conditions: HL (%1-RM/cuff pressure: 80%/0); LL (20%/0); LBFR(sub DBP) (20%/1.3 x diastolic blood pressure, BP); LBFR(sub SBP) (20%/1.3 x supine systolic BP). The cuff remained inflated throughout the LBFR exercise sessions. Artery diameter, velocity time integral (VTI), and stroke volume (SV) were measured using Doppler ultrasound at rest and immediately after each set of exercise. Heart rate (HR) was monitored using a 3-lead ECG. BF was calculated as VTI x vessel cross-sectional area. CO was calculated as HR x SV. The data obtained after each set of exercise were averaged and used for analyses. Multi-level modeling was used to determine the effect of exercise condition on dependent variables. Statistical significance was set a priori at p< 0.05. RESULTS: Artery diameter did not change from baseline. BF increased (p<0.05) after exercise in each condition except LBFR(sub SBP) in the order of HL (12.73+/-1.42 cm3,mean+/-SE) > LL (9.92+/-0.82 cm3) > LBFR(sub dBP)(6.47+/-0.79 cm3) > LBFR(sub SBP) (3.51+/-0.59 cm3). Blunted exercise induced increases occurred in HR, SV, and CO after LBFR compared to HL and LL. HR increased 45% after HL and LL and 28% after LBFR (p<0.05), but SV increased (p<0.05) only after HL. Consequently, the increase (p<0.05) in CO was greater in HL and LL (approximately 3 L/min) than in LBFR (approximately 1 L/min). CONCLUSION: BF during LBFR(sub SBP) was 1/3 of that observed in LL, which supports the hypothesis that local ischemia stimulates the LBFR hypertrophic response. As the cuff did not compress the artery, the ischemia may have occurred because of the blunted rise in CO or because arterial BP cannot overcome the cuff pressure. As LBFR(sub DBP) effectively reduced BF and CO with cuff pressures less than systolic BP, future studies should investigate the hypertrophic potential of LBFR at even lower cuff pressures.

Everett, M. E.↗

Evaluation of Human Spaceflight-Related Tissue Weight Relief Using Whole Body Finite Element Model Simulations

Tissue Weight Relief (TWR) is a physiological condition observed in human spaceflight. It not only impacts the injury biomechanics of soft tissue but also the physiological responses of the cardiovascular system both due to fluid redistribution and the effect of tissue-related transmural pressure on the large venous blood vessels. Understanding the effects of tissue weight relief is especially important because of the role it may play in understanding the cause of Space Associated Neuro-Ocular Syndrome (SANS). SANS can be characterized by a number of ocular changes which reduce visual acuity and SANS related symptoms occur in up to 51% of astronauts. A prevailing theory for the causation of SANS is that of headward (cephalad) fluid shift and a prolonged increase of Intracranial Pressure (ICP) similar to intracranial hypertension, which is not fully supported by the experimental data or astronaut symptom reporting. However, it is still believed that SANS is caused by a pressure change in the eye and the surrounding tissues. It has been proposed that TWR plays a substantial role in affecting internal pressures and fluid shifts in microgravity. In this effort, two whole-body Finite Element (FE) models – Elemance and THUMS – are used to ascertain the microgravity-associated TWR of the musculature surrounding the lower body veins. Elemance and THUMS are physics-based computational models that have been validated and verified for several automotive and domestic applications, and as such, can simulate the relief of soft tissue weight due to changes in the gravitation vector. Specifically, the current effort modeled the transition of the gravitational vector from 1G to 0G, applied across the whole-body model in a supine position. For each 1G to 0G transition simulation, the lower body vein’s transmural pressure-time profile was extracted and averaged around the anterior portion of the thigh muscle. The ascertained transmural pressure changes from 1G to 0G transition are given in Figure 1 for the Elemance and the THUMS FE models. The transmural pressure changes of 10 mmHg and 21 mmHg are in the same order of magnitude as Lu’s value of 44 mmHg. It is to be noted that Lu implemented a 0D to 1D lumped parameter model and the Elemance and THUMS are 3D higher order computational models. This proof-of-concept approach demonstrates that TWR pressure can be adequately estimated with in silico techniques however, further in silico investigations need to be conducted to address the unique contributions to the transmural pressure from each of the computational models.

Finite element modeling↗

Orion Meteoroid and Debris Analysis with a Single Kevlar® Layer Enhancement to the Propulsion Tank Multi-Layer Insulation: Comparison of the Observed Data and the Adjusted Ballistic Models

In a continual mass optimization effort for the Orion vehicle by NASA and its prime contractor Lockheed Martin Space, along with the European Space Agency (ESA) and its contractors Airbus and Thales Alenia Space-Italy (TAS-I), a series of shield characterization shots have been performed to quantify the ballistic enhancement of a single-layer of Kevlar® in multi-layer insulation (MLI). This enhanced MLI is part of Orion’s propulsion subsystem, and it is planned to replace a double-layer Kevlar® configuration starting at the Artemis IV mission. This effort has included fifty-two shield characterization shots for five different shield configurations over the four Orion propellant storage vessels. These storage vessels are located in the European Service Module (ESM). This shield characterization has been managed by the Hypervelocity Impact Technology (HVIT) group in NASA Astromaterials Research and Exploration Sciences at Johnson Space Center (JSC) for the NASA Engineering and Safety Center (NESC) and the Multi-Purpose Crew Vehicle (MPCV) program office in coordination with Lockheed Martin Space and Thales Alenia Space-Italy (TAS-I). The shield characterization has used the two-stage, light-gas-gun at the Remote Hypervelocity Test Laboratory (RHTL) of NASA JSC White Sands Test Facility (WSTF) for acceleration of projectiles to representative orbital impact speeds. From this shield characterization effort, a revised ballistic limiting equation (BLE) has been developed for each of the five representative shielding configurations of the ESM pressure vessels. This document provides a brief description of the shield configurations considered for the Orion program and the shield characterization findings. These results are compared to the assumed BLE for each configuration going into the Artemis missions that utilize this version of ballistic enhanced MLI. The models are integrated into a fourteen day High Lunar Orbit (HLO) mission as a representative reliability prediction impact for Orion, and it has been found that the predicted risk of a loss-of-crew (LOC) event is actually a little less than half of the assumed value that launched this design modification opportunity.

Joshua E Miller↗

Elastic-Plastic Thermal Stress Analysis of a High-Pressure Cryogenic Storage Tank

The thermal stresses on a cryogenic storage tank contribute strongly to the state of stress of the tank material and its ability to withstand operational stresses. These thermal stresses also affect the growth of any surface damage that might occur in the tank walls. These stresses are particularly of concern during the initial cooldown period for a new tank placed into service, and during any subsequent thermal cycles. A previous preliminary elastic analysis showed that the thermal stress on the inner wall would reach approximately 1,000MPa (145,000 psi). This stress far exceeds the ASTM specified room temperature values for both yield (170MPa) and ultimate (485 MPa) strength for 304L stainless steel. The present analysis determines the thermal stresses using an elastic-plastic model. The commercial software application ANSYS was used to determine the transient spatial temperature profile and the associated spatial thermal stress profiles in a segment of a thick-walled vessel during a typical cooldown process. A strictly elastic analysis using standard material properties for 304L stainless steel showed that the maximum thermal stress on the inner and outer walls was approximately 960 MPa (tensile) and - 270 MPa (compressive) respectively. These values occurred early in the cooldown process, but at different times, An elastic-plastic analysis showed significantly reducing stress, as expected due to the plastic deformation of the material. The maximum stress for the inner wall was approximately 225 MPa (tensile), while the maximum stress for the outer wall was approximately - 130 MPa (compressive).

Barker, J. Mark↗

Reliability Considerations for Composite Overwrapped Pressure Vessels on Spacecraft

Composite Overwrapped Pressure Vessels (COPVs) are used to store gases under high pressure onboard spacecraft. These are used for a variety of purposes such as propelling liquid fuel etc, Kevlar, glass, Carbon and other more recent fibers have all been in use to overwrap the vessels. COPVs usually have a thin metallic liner with the primary purpose of containing the gases and prevent any leakage. The liner is overwrapped with filament wound composite such as Kevlar, Carbon or Glass fiber. Although the liner is required to perform in the leak before break mode making the failure a relatively benign mode, the overwrap can fail catastrophically under sustained load due to stress rupture. It is this failure mode that is of major concern as the stored energy of such vessels is often great enough ta cause loss of crew and vehicle. The present paper addresses some of the reliability concerns associated specifically with Kevlar Composite Overwrapped Pressure Vessels. The primary focus of the paper is on how reliability of COPV's are established for the purpose of deciding in general their flight worthiness and continued use. Analytical models based on existing design data will be presented showing how to achieve the required reliability metric to the end of a specific period of performance. Uncertainties in the design parameters and how they affect reliability and confidence intervals will be addressed as well. Some trade studies showing how reliability changes with time during a program period will be presented.

Murthy, Pappu L. N.↗

Nondestructive Evaluation and Monitoring Results from COPV Accelerated Stress Rupture Testing, NASA White Sands Test Facility (WSTF)

Develop and demonstrate NDE techniques for real-time characterization of CPVs and, where possible, identification of NDE capable of assessing stress rupture related strength degradation and/or making vessel life predictions (structural health monitoring or periodic inspection modes). Secondary: Provide the COPV user and materials community with quality carbon/epoxy (C/Ep) COPV stress rupture progression rate data. Aid in modeling, manufacturing, and application of COPVs for NASA spacecraft.

Saulsberry Regor↗

Computational Fluid Dynamics Simulation of Methane Slosh and Drain Experiments

NASA possesses a wealth of historical cryogenic experiments that provide valuable insights into the design, troubleshooting, and understanding involved in the complex fluid and thermodynamics of managing cryogenic propellants. One approach to leveraging these historical datasets is by simulating these experiments to validate the accuracy of simulation environments and constituent models. This study focused on simulating a selection of the K site test series for both static and sloshing pressurized liquid methane draining experiments conducted at NASA in the 1970’s, utilizing computational fluid dynamics. The simulations were performed in the ANSYS FLUENT environment using the Volume of Fluid (VOF) numerical approach. A k-omega turbulence model was used with interfacial turbulence damping, and accurately predicted the amount of pressurant needed to maintain the required tank pressure throughout the static drain. The static simulation predicted the temperature stratification in the ullage observed at the end of the drain. During the methane expulsion with sloshing test, many features were successfully captured using the k-omega turbulence model with interfacial turbulence damping included. The rate of phase change and liquid temperature was overpredicted compared to the experimental measurements. The overprediction may be attributed to uncertainties in the vessel geometry, methane pressurant temperature and composition, and methodological differences in how the sloshing frequency was adjusted during the expulsion.

Cryogenic Propellants↗

Automatic Processing of Reactive Polymers

A series of process modeling computer codes were examined. The codes use finite element techniques to determine the time-dependent process parameters operative during nonisothermal reactive flows such as can occur in reaction injection molding or composites fabrication. The use of these analytical codes to perform experimental control functions is examined; since the models can determine the state of all variables everywhere in the system, they can be used in a manner similar to currently available experimental probes. A small but well instrumented reaction vessel in which fiber-reinforced plaques are cured using computer control and data acquisition was used. The finite element codes were also extended to treat this particular process.

Roylance, D.↗

Bi-Axial Load Testing of a Woven-Webbing Inflatable Space Habitat Restraint Layer Component

This report discusses testing of a bi-axial woven panel consisting of high-strength webbings that represent a portion of the structural restraint layer of an inflatable space structure. Inflatable softgoods vessels are being researched for human space missions as possible habitats, airlocks and tunnel elements. Understanding the complex behavior of the softgoods restraint layer and maturing finite element analysis capabilities to model these structures is critical to their successful implementation. The primary goal of this research is to study the load-up and load distribution in a weave of webbings, before and after the loss of tension in one of the webbings. In addition, a key objective is to evaluate the ability to convert strains measured via photogrammetry using digital image correlation to loads in the weave. The report gives an introduction and objectives for the test program and a description of the test fixture, setup and procedure. This is followed by a section focusing on the test data and associated discussion. To streamline presentation of the data, one focus case is detailed in the main text. (Comprehensive data set can be found in Appendix A for the three remaining test cases.) In addition to the load and time histories for one case, summary charts and tables that incorporate data from all four test cases are provided. The concluding remarks include major findings, lessons learned and recommendations for future work. Appendix B provides complementary full-field strain results when considering the existing woven webbing data as a fabric. These types of results could inform models intended for global representation. Appendix C contains a description from a series of exploratory instrumented hammer tap tests and results on the weave. These tests describe an area of research for the biaxial test fixture beyond the current testing studying the propagation and detection of vibrations in a tensioned weave that has applications in impact and damage detection.

Karen H Lyle↗

Damage tolerance in filament-wound graphite/epoxy pressure vessels

Graphite/epoxy composites are extensively used in the aerospace and sporting goods industries due to their superior engineering properties compared to those of metals. However, graphite/epoxy is extremely susceptible to impact damage which can cause considerable and sometimes undetected reduction in strength. An inelastic impact model was developed to predict damage due to low-velocity impact. A transient dynamic finite element formulation was used in conjunction with the 3D Tsai-Wu failure criterion to determine and incorporate failure in the materials during impact. Material degradation can be adjusted from no degradation to partial degradation to full degradation. The developed software is based on an object-oriented implementation framework called Extensible Implementation Framework for Finite Elements (EIFFE).

Simon, William E.↗

Altered TNF-Alpha, Glucose, Insulin and Amino Acids in Islets Langerhans Cultured in a Microgravity Model System

The present studies were designed to determine effects of a microgravity model system upon lipopolysaccharide (LPS) stimulated tumor necrosis factor alpha (TNF-alpha) activity and indices of insulin and fuel homeostasis of pancreatic islets of Langerhans. Islets (1726+/-1 17,150 u IEU) from Wistar Furth rats were treated as: 1) HARV (High Aspect Ratio Vessel cell culture) , 2) HARV plus LPS, 3) static culture, 4) static culture plus LPS. TNF-alpha (L929 cytotoxicity assay) was significantly increased in LPS-induced HARV and static cultures, yet the increase was more pronounced in the static culture group (p<0.05). A decrease in insulin concentration was demonstrated in the LPS stimulated HARV culture (p<0.05). We observed a greater glucose concentration and increased disappearance of arginine in islets cultured in HARVs. While nitrogenous compound analysis indicated a ubiquitous reliance upon glutamine in all experimental groups, arginine was converted to ornithine at a two-fold greater rate in the islets cultured in the HARV microgravity model system (p<0.05). These studies demonstrate alterations in LPS induced TNF-alpha production of pancreatic islets of Langerhans, favoring a lesser TNF activity in the HARV. These alterations in fuel homeostasis may be promulgated by gravity averaged cell culture methods or by three dimensional cell assembly.

Tobin, Brian W.↗

Ultrasonic Doppler measurement of renal artery blood flow

An extensive evaluation of the practical and theoretical limitations encountered in the use of totally implantable CW Doppler flowmeters is provided. Theoretical analyses, computer models, in-vitro and in-vivo calibration studies describe the sources and magnitudes of potential errors in the measurement of blood flow through the renal artery, as well as larger vessels in the circulatory system. The evaluation of new flowmeter/transducer systems and their use in physiological investigations is reported.

Freund, W. R.↗

GPS Moving Vehicle Experiment

The Naval Research Laboratory (NRL) in the development of timing systems for remote locations, had a technical requirement for a Y code (SA/AS) Global Positioning System (GPS) precise time transfer receiver (TTR) which could be used both in a stationary mode or mobile mode. A contract was awarded to the Stanford Telecommunication Corporation (STEL) to build such a device. The Eastern Range (ER) als had a requirement for such a receiver and entered into the contract with NRL for the procurement of additional receivers. The Moving Vehicle Experiment (MVE) described in this paper is the first in situ test of the STEL Model 5401C Time Transfer System in both stationary and mobile operations. The primary objective of the MVE was to test the timing accuracy of the newly developed GPS TTR aboard a moving vessel. To accomplish this objective, a joint experiment was performed with personnel from NRL and the er at the Atlantic Undersea Test and Evaluation Center (AUTEC) test range at Andros Island. Results and discussion of the test are presented in this paper.

Oaks, O. J.↗

Validation and Verification of Composite Pressure Vessel Design

Ten composite pressure vessels were instrumented with fiber Bragg grating sensors and pressure tested Through burst. This paper and presentation will discuss the testing methodology, the test results, compare the testing results to the analytical model, and also compare the fiber Bragg grating sensor data with data obtained against that obtained from foil strain gages.

Kreger, Stephen T.↗

High-Power Piezoelectric Acoustic-Electric Power Feedthru for Metal Walls

Piezoelectric acoustic-electric power feed-through devices transfer electric power wirelessly through a solid wall by using acoustic waves. This approach allows for the removal of holes through structures. The technology is applicable to power supply for electric equipment inside sealed containers, vacuum or pressure vessels, etc where the holes on the wall are prohibitive or result in significant performance degrade or complex designs. In the author's previous work, 100-W electric power was transferred through a metal wall by a small, simple-structure piezoelectric device. To meet requirements of higher power applications, the feasibility to transfer kilowatts level power was investigated. Pre-stressed longitudinal piezoelectric feedthru devices were analyzed by finite element model. An equivalent circuit model was developed to predict the power transfer characteristics to different electric loads. Based on the analysis results, a prototype device was designed, fabricated and a demonstration of the transmission of electric power up to 1-kW was successfully conducted. The methods to minimize the plate wave excitation on the wall were also analyzed. Both model analysis and experimental results are presented in detail in this presentation.

acoustic wave↗

LIMEX '87 ice surface characteristics - Implications for C-band SAR backscatter signatures

Ice surface characterization data collected in 1987, during the Labrador Sea Ice Margin Experiment, are analyzed to estimate the changes in snow and ice properties at the onset of melt. Surface measurements were made from an ice research vessel on several days (some of which had coincident remote-sensing flights) at a number of locations in the marginal ice zone. These data are used as input parameters in a simple scattering model to simulate the effects of variations in material properties upon C-band scattering signatures. Snow moisture and large-scale surface roughness are demonstrated to have the largest effect upon HH polarization scattering cross-section sigma(HH)(O) and large differences are predicted between undeformed floe surfaces and deformed or undulating rough ice surfaces. Using a parametric approach, an approximate picture of rough and smooth ice signatures and their relative contrast are provided. The models reproduce a trend observed in synthetic aperture radar (SAR) images of increasing backscatter contrast between deformed and underformed ice over an early period of warning: such observations are consistent with the results of analysis of SAR images to date. The model also reproduces a calibrated SAR-derived signature with a reasonable degree of accuracy.

Drinkwater, Mark R.↗

Gravitational Effects on Signal Transduction

An understanding of the mechanisms by which individual cells perceive gravity and how these cells transduce and respond to gravitational stimuli is critical for the development of long-term manned space flight experiments. We now propose to use a well-characterized model erythroid cell system and to investigate gravitational perturbations of its erythropoietin (Epo) signaling pathway and gene regulation. Cells will be grown at 1-G and in simulated microgravity in the NASA Rotating Wall Vessel bioreactor (RWV). Cell growth and differentiation, the Epo-receptor, the protein kinase C pathway to the c-myc gene, and the protein phosphatase pathway to the c-myb gene will be studied and evaluated as reporters of gravitational stimuli. The results of these experiments will have impact on the problems of 1) gravitational sensing by individual cells, and 2) the anemia of space flight. This ground-based study also will serve as a Space Station Development Study in gravitational effects on intracellular signal transduction.

Sytkowski, Arthur J.↗