Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Verification of data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Multiphase Species Transport Modeling for Molten Salt Reactors in the System Analysis Module: Generation, Decay, Deposition, and Extraction of Insoluble Fission Products

With the increase of interests in the design and deployment of advanced reactor systems, a desire for simulation tools supporting system analysis of reactor operation and safety is rising. Molten salt reactors (MSRs), one of the advanced reactor systems, utilize liquid fused salt fuel as both coolant and fuel. During operation, MSR generates insoluble fission products, including noble metals and gases. The buildup of these species in fuel salt presents safety concerns as they may deposit on surfaces of critical components and produce excessive decay heat, causing the failure of system components. Timely removal of these noble metals and gases would ensure the safe operation of the reactor system. The dynamic nature of salt fuel system, involving the generation, decay, deposition, and extraction of noble metals and gases, calls for robust species transport models to facilitate system analysis and monitoring, and design of efficient species removal components. This paper concentrates on the development of a computational framework for species transport, consisting of multiphase transport model formulation, mass transfer between phases, numerical implementation in MOOSE environment, verification through Method of Manufacture Solutions (MMS) and validation against experimental data from the Molten Salt Reactor Experiment (MSRE). Integrating this framework into the System Analysis Module (SAM) code further enhances SAM’s capabilities for advanced reactor analysis in the future.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Stone Content Influence on Land Surface Model Simulation of Soil Moisture and Evapotranspiration at Reynolds Creek Watershed

Considerable advancement in spatiotemporal resolution of remote sensing and ground-based measurements has enabled refinement of parameters used in land surface models for simulating surface water fluxes. However, land surface modeling capabilities are still inadequate for accurate representation of subsurface properties and processes, which continue to limit the accuracy of land surface model simulation. Our objective in this study was to examine the performance of the variously parameterized Noah-Multiphysics (Noah-MP) land surface model and to improve simulations of evapotranspiration (ET) and soil moisture dynamics in stony soils using verification from eddy covariance ET and in-situ soil moisture data. Meteorological and eddy covariance data from the Lower Sheep sub-catchment within the Reynolds Creek Experimental Watershed in Southwestern Idaho were employed to drive Noah-MP and to assess simulation results. We evaluated the performance of Noah-MP considering four different scenarios: (1) A one-layer soil profile with Noah-MP default soil hydraulic parameters, followed by five-layer soil profiles using -(2) Noah-MP default soil hydraulic parameters -(3) soil hydraulic parameters derived from a pedotransfer function using field observations, and -(4) hydraulic parameters from (3) which also accounted for stone content in each layer. Each modeling experiment was forced with the same set of initial conditions, atmospheric input and vegetation parameters. Our results indicated that enhanced representation of soil profile properties and stone content information noticeably improve the Noah-MP land surface model simulation of soil moisture content and evapotranspiration.

Land surface models, Soil hydrology, Noah-MP, Evap↗

Root genetics in the field to understand drought adaptation and carbon sequestration (Final Scientific/Technical Report)

For all crop plants, roots play a critical role in growth. Roots anchor the plants, and are the primary site of nutrient and water uptake. Roots are also the main source of C to soil in the form of root tissues and exudates, and thus greatly influence SOM stocks. To perform these functions, primary roots extend into soil, producing a network of branching roots of characteristic form, known as its root system architecture (RSA). RSA varies among species, and among varieties within a species that are adapted to different environments. Root traits are major targets for the second green revolution because of their potential to improve crop productivity, increase drought tolerance and nutrient acquisition, and increase C capture of soil. Improving the quality of roots in maize will be particularly valuable, since this crop is planted on over 92 million acres annually in the US. The future sustainability of agricultural systems relies on their ability to enhance soil organic matter (SOM) storage and reduce GHG emissions, while maintaining or enhancing productivity. This program had two components, Sensors and Models. For the first component, we designed and built a high-throughput phenotyping platform for root pulling of maize plants. This eliminated the physical labor of manually pulling up plants and reduced the number of personnel required down to one. The standardized pulling mechanism allowed recording force curves during the pulling process, providing additional information. We validated that the maximum force for pulling the root system was well-correlated with the root system mass and provided root crowns for further RSA analysis. These root crowns identified significant correlations with 2D root area and root depth, along with 3D root volume, total root length and number of root tips. We then used this system for field-based studies in maize on the genetics of root system architecture and its relation to nitrogen-use efficiency (NUE), including using lines relevant to the Corteva breeding program. Varieties were also evaluated at Corteva sites in the cornbelt and Danforth farm in Missouri, to establish responses across sites. From these studies we have identified genetic loci associated with root traits and created mutant lines for these loci and correlations of root traits with NUE. For the Models component, we worked to incorporate root and soil characteristics into the MEMS 2.0 soil and ecosystem biogeochemical model. Existing soil C models, such as Century, are unable to represent specific root trait interactions with the soil environment and therefore to accurately forecast the potential C sequestration benefits of root breeding under different climatic and soil type conditions. We have developed the MEMS 2.0 ecosystem biogeochemical model to improve quantification of farm-scale soil carbon and greenhouse gas emissions. The new knowledge and large datasets produced by this project will be used to develop and drive an innovative model capable of forecasting the impacts on soil C stocks and nutrient dynamics. An innovation was to use the empirical data from the field studies (in 1, above) to model genetic variation in nitrogen use efficiencies and soil C input. Our work demonstrated that maize root-derived C rapidly replaces existing soil C and after 3 years of continuous maize, up to 20% of soil organic C in the topsoil (0-15cm) and 3% in the subsoil (15-30cm) was contributed by maize. However, this contribution did not entirely represent a net increase. Root C contribution to soil was affected by maize genetics. We have analyzed soils derived from the CSU field trials for C and N stocks, in the different soil physical fractions represented by the MEMS model, using both physical fractionation with elemental analyses, and Fourier transformed infrared spectroscopy. Data will be used to link crop nitrogen use efficiencies with soil C sequestration and provide data to bridge the field trials with the model development, for verification of model predictions. The project had a number of successful outcomes: we have used the new phenotyping platform to identify new genetic loci that can enhance root phenotypes; we have partnered with multiple maize seed companies phenotype varieties in their breeding programs; we have developed the MEMS model that can help inform industry on the potential for carbon sequestration in the agricultural sector, and which is now available at the CSU Soil Carbon Solutions Center for use.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of AI-enabled Digital Documented Safety Analysis

The National Reactor Innovation Center (NRIC) is leading a transformative initiative to accelerate advanced reactor deployment by fundamentally reimagining how nuclear safety basis documentation is developed, reviewed, and maintained. Traditional Documented Safety Analysis (DSA) processes for DOE-authorized facilities rely on static, document-centric workflows that consume significant time and resources, exemplified by recent major licensing efforts requiring hundreds of thousands of staff hours and millions of pages of documentation review. These conventional approaches create barriers to the rapid, cost-effective deployment of advanced reactors that America's future energy needs demand. NRIC's DOE Authorization Digital Transformation Project addresses these challenges through an innovative framework that integrates artificial intelligence (AI), digital engineering, and systems-based data management into a cohesive digital ecosystem. This white paper presents NRIC's methodology for evaluating AI-enabled document generation capabilities within this broader digital infrastructure, using the Demonstration of Microreactor Experiments (DOME) facility as a pilot case study. The evaluation will assess an AI tool's ability to generate a Preliminary Documented Safety Analysis (PDSA) through progressive integration stages—from standalone document processing to full digital thread connectivity—while maintaining rigorous verification, validation, and regulatory acceptance standards. By establishing dynamic, traceable connections between design data and safety documentation, NRIC's approach has the potential to reduce both document development time and regulatory review cycles by as much as 50%, while simultaneously improving accuracy, consistency, and traceability. This initiative represents a critical step toward establishing reusable digital infrastructure that reactor developers can leverage to accelerate their path from concept to commercial operation, directly supporting NRIC's mission to demonstrate and deploy advanced nuclear energy technologies.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Challenges in Automated Detection of COVID-19 Misinformation

The COVID-19 pandemic has made the dangers of the spread of misinformation obvious but despite much global effort to curbing its spread, fake information about the pandemic keeps proliferating. In this paper, we address the development of automated methods for verification of claims about COVID-19 and discuss the challenges associated with this task. We focus on labeled data collection, limitations of existing models, and difficulties of applying misinformation detection models in practical applications. Our initial analysis indicates label imbalance may be a particular challenge for developing claim verification models and we discuss options for alleviating this issue.

Herrmannova, Dasha↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Special Observing Period (SOP) data for the Year of Polar Prediction site Model Intercomparison Project (YOPPsiteMIP)

The rapid changes occurring in the polar regions require an improved understanding of the processes that are driving these changes. At the same time, increased human activities such as marine navigation, resource exploitation, aviation, commercial fishing, and tourism require reliable and relevant weather information. One of the primary goals of the World Meteorological Organization's Year of Polar Prediction (YOPP) project is to improve the accuracy of numerical weather prediction (NWP) at high latitudes. During YOPP, two Canadian “supersites” were commissioned and equipped with new ground-based instruments for enhanced meteorological and system process observations. Additional pre-existing supersites in Canada, the United States, Norway, Finland, and Russia also provided data from ongoing long-term observing programs. These supersites collected a wealth of observations that are well suited to address YOPP objectives. In order to increase data useability and station interoperability, novel Merged Observatory Data Files (MODFs) were created for the seven supersites over two Special Observing Periods (February to March 2018 and July to September 2018). All observations collected at the supersites were compiled into this standardized NetCDF MODF format, simplifying the process of conducting pan-Arctic NWP verification and process evaluation studies. This paper describes the seven Arctic YOPP supersites, their instrumentation, data collection and processing methods, the novel MODF format, and examples of the observations contained therein. MODFs comprise the observational contribution to the model intercomparison effort, termed YOPP site Model Intercomparison Project (YOPPsiteMIP). All YOPPsiteMIP MODFs are publicly accessible via the YOPP Data Portal (Whitehorse: https://doi.org/10.21343/a33e-j150, Huang et al., 2023a; Iqaluit: https://doi.org/10.21343/yrnf-ck57, Huang et al., 2023b; Sodankylä: https://doi.org/10.21343/m16p-pq17, O'Connor, 2023; Utqiagvik: https://doi.org/10.21343/a2dx-nq55, Akish and Morris, 2023c; Tiksi: https://doi.org/10.21343/5bwn-w881, Akish and Morris, 2023b; Ny-Ålesund: https://doi.org/10.21343/y89m-6393, Holt, 2023; and Eureka: https://doi.org/10.21343/r85j-tc61, Akish and Morris, 2023a), which is hosted by MET Norway, with corresponding output from NWP models.

54 ENVIRONMENTAL SCIENCES↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emulation Modeling for Development of Cyber-Defense Capabilities for Satellite Systems

The objective of this project was to develop a novel capability to generate synthetic data sets for the purpose of training Machine Learning (ML) algorithms for the detection of malicious activities on satellite systems. The approach experimented with was to a) generate sparse data sets using emulation modeling and b) enlarge the sparse data using Generative Adversarial Networks (GANs). We based our emulation modeling on the Open Source NASA Operational Simulator for Small Satellites (NOS3) developed by the Katherine Johnson Independent Verification and Validation (IV&V) program in West Virginia. Significant new capabilities on NOS3 had to be developed for our data set generation needs. To expand these data sets for the purpose of training ML, we experimented with a) Extreme Learning Machines (ELMs) and b) Wasserstein-GANs (WGAN-GP).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Improvements to the New CTH Code Verification & Validation Test Suite (FY2020)

The CTH multiphysics hydrocode, which is used for a wide range of important calculations, has undertaken in recent years to overhaul its software quality and testing processes. A key part of this effort entailed building a new, robust V&V test suite made up of traditional hydrocode verification problems, such as those listed in the ASC Tri-Lab Test Suite and the Enhanced Tri-Lab Test Suite, as well as validation problems for some of CTHs most frequently used equations of state, materials models, and other key capabilities. Substantial progress towards this goal was made in FY19. In FY20, this test suite has been expanded to include verification and validation tests of the Sesame and JWL equation of state models as well as the Mader verification problem from the Tri-Lab Test Suite and the Blake verification problem - a linear elastic analog to the Hunter problem from the Enhanced Tri-Lab Test Suite. This report documents CTH performance on the new test suite problems. Verification test results are compared to analytic solutions and, for most tests, convergence results are presented. Validation test results are compared to experimental data and mesh refinement studies are included. CTH performs well overall on the new test problems. Convergence rates for the Blake and Mader problems are comparable to those for similar ASC codes. The JWL and Sesame verification tests show good agreement with analytic solutions. Likewise, CTH simulation results show good agreement with experimental validation data for the Sesame and JWL equations of state for the materials tested. Future V&V work will focus on adding tests for other key capabilities like fracture and high explosive models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating Symmetry in 3-dimensional Simulation Data

The increasing use of three-dimensional simulations has led to an increased need for effective verification and validation, or V&V. Unfortunately, the high computational cost associated with three-dimensional simulations makes many standard V&V techniques cost-prohibitive. Given these circumstances, we must pay close attention to V&V metrics that can be evaluated using only a single simulation. One of the simplest of these metrics is the evaluation of physical symmetries. This report details a method of computing the deviation from symmetry in a three-dimensional dataset with an arbitrarily distributed mesh. Examples are presented for spherical and axisymmetric systems using the Paraview post-processing analysis workflow.

97 MATHEMATICS AND COMPUTING↗

Infusible Thermoplastic Composites for Wind Turbine Blade Manufacturing: Fatigue Life of Thermoplastic Laminates under Ambient and Low-Temperature Conditions

Traditionally, thermoset resins such as polyesters (PE) and epoxies are used as the polymer matrix for construction of wind turbine blades. However, concern about their end-of-life treatment garners interest to use thermoplastics for increased recyclability. However, the high viscosity of molten thermoplastics inhibits their use in manufacturing wind turbine blades with injection or compression molding. A recently developed, infusible, reactive thermoplastic resin overcomes this technological barrier. Toward verifying that this recyclable resin is suitable for use in wind turbine blades, a dataset of R?=?0.1 and R?=?10 fatigue data for glass fiber-reinforced acrylic composites is provided and equal fatigue life to industry standard epoxy and unsaturated PE resin systems is demonstrated. Specifically, R?=?0.1 fatigue data for acrylic composites at room temperature and -30?degrees C for verification of low-temperature performance are tabulated. To elucidate failure mechanisms, in situ mechanical testing with X-ray computed tomography demonstrates that damage accumulation occurs by crack propagation along the fiber-matrix interface under cyclic loading. Infrared (IR) thermography predicts failure points in composites specimens with porosity defects introduced from nonideal manufacturing processes. Furthermore, these manufacturing defects are shown to compromise the fatigue life of the acrylic laminates by an order of magnitude.

effect of defects↗

nrelWattileExt (SkySpark Wattile Extension) [SWR-24-73]

The NREL Wattile extension, nrelWattileExt, provides an interface between SkySpark, an energy management and analytics software, and Wattile, an NREL-developed Python package for probabilistic prediction of building energy consumption. Wattile models predict discrete quantiles of the probability distribution of a target quantity (typically energy consumption) using the historical time series data from one or more predictors (typically weather data). Within SkySpark, predictions from Wattile models can be used for measurement & verification of building performance, detection of energy anomalies, and fault detection. Related to: https://github.com/NREL/Wattile

Frank, Stephen↗

Verification and Benchmarking of High Fidelity Physics Peat Smoldering Model

Peat fires are a major contributor to greenhouse gas emissions. The estimates of these emissions currently contain major uncertainties, due to the difficulty of determining the mass of peat burned in a fire. To address these uncertainties, we develop a computational physics-based peat smoldering model, which will be leveraged for high-fidelity quantitative estimates of peat fire emissions relevant to climate change. We present the verification of the 2-D axisymmetric model, a first step towards developing a full 3-D model. Verification includes the solution verification against a literature model for the 0-D smoldering case and verification of the heat transfer problem in 1-D and 2-D. Also presented is the effect of reaction mechanism on the smoldering model, for which we found a relatively simple three-step reaction mechanism is able to capture key behavior. These verification results provide the foundation for moving forward with validation against experimental data of the 2-D model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical Analysis of Blast Effects and Mitigation in the Far-Field from Small Explosions

Requirements for explosive safety are often given in terms of a “K-Factor”, correlating incident blast effects with the distance and TNT equivalent weight of an explosion. Traditionally, this is conducted using empirical correlations to experimental measurements (e.g., the Kingery–Bulmash equations). In the far-field, empirical verification of incident overpressure and impulse magnitudes can be difficult; extrapolations from data give expected values at reasonable standoff distances that sometimes are too small to measure on available equipment but are larger than some regulations require. The present paper describes the results of numerical hydrocode analysis to verify the expected incident overpressure and impulse from small hemispherical ground charges of TNT at these relatively large distances. Furthermore, the dynamic effect of incident blast waves on lightweight, modular mitigation barriers is studied to gauge their effectiveness at providing safety standard compliance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated Operations for Nuclear Business Operation Model Analysis and Industry Validation

The purpose of this report is to refine and analyze five work reduction opportunities first presented in INL/EXT-21-64134, Process for Significant Nuclear Work Function Innovation Based on Integrated Operations Concepts. This report seeks to further refine and analyze five work reduction opportunities first presented in the original report. Researchers selected five work reduction opportunities from the full Integrated Operations for Nuclear (ION) suite. A selected group of utilities then verified details and inputs from the original report. Categories for verification included capital cost, technology requirements, and savings. Researchers then modeled the data points and data ranges using probabilistic analysis which predicts the likelihood of positive or negative net present value. Research results show four out of the five work reduction opportunities have a greater than fifty percent chance of a positive net present value outcome when analyzed independently. When the five work reduction opportunities are grouped and analyzed together the model indicates a sixty percent chance that the outcome of all five taken together will be positive. The nuclear industry should interpret these results as encouraging. In line with the ION model, positive financial analysis supports the investment of capital dollars into existing nuclear power plants along the ION model. Implementation of the five work reduction opportunities in this report is likely to result in substantive long-term savings for the owners and operators of domestic nuclear power plants.

99 GENERAL AND MISCELLANEOUS↗

Synthetic Scientific Image Generation with VAE, GAN, and Diffusion Model Architectures

Generative AI (genAI) has emerged as a powerful tool for synthesizing diverse and complex image data, offering new possibilities for scientific imaging applications. This review presents a comprehensive comparative analysis of leading generative architectures, ranging from Variational Autoencoders (VAEs) to Generative Adversarial Networks (GANs) on through to Diffusion Models, in the context of scientific image synthesis. We examine each model's foundational principles, recent architectural advancements, and practical trade-offs. Our evaluation, conducted on domain-specific datasets including microCT scans of rocks and composite fibers, as well as high-resolution images of plant roots, integrates both quantitative metrics (SSIM, LPIPS, FID, CLIPScore) and expert-driven qualitative assessments. Results show that GANs, particularly StyleGAN, produce images with high perceptual quality and structural coherence. Diffusion-based models for inpainting and image variation, such as DALL-E 2, delivered high realism and semantic alignment but generally struggled in balancing visual fidelity with scientific accuracy. Importantly, our findings reveal limitations of standard quantitative metrics in capturing scientific relevance, underscoring the need for domain-expert validation. We conclude by discussing key challenges such as model interpretability, computational cost, and verification protocols, and discuss future directions where generative AI can drive innovation in data augmentation, simulation, and hypothesis generation in scientific research.

Generative Adversarial Networks↗