Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VISUAL SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Feature Tracking and Visualization of Madden-Julian Osciallation in Climate Simulation

Madden-Julian Oscillation (MJO) is one of the less understood aspects of tropical meteorology, which plays a significant role in tropical intra-seasonal variations in rain, temperature and winds over the Indian and Pacific Oceans. In this paper, we present an integrated analysis and visualization framework for MJO episodes simulated by a high resolution regional model. To distinguish MJOs from other weather phenomena, our framework utilizes domain knowledge to track MJOs as finding the globally optimized properties in the data. In addition to enhancing the animation with feature tracking, our visualization system also integrates different visualization components such as Virtual Globe and Hovmoller Diagrams to visualize large scale events both in space and time. By linking all of these visualization components on a web-based interface, scientists can identify cloud and environmental processes associated with the initiation and eastward propagation of MJO more easily.

big-data visualization↗

SU-E-J-196: Implementation of An In-House Visual Feedback System for Motion Management During Radiation Therapy

Purpose: To describe an in-house video goggle feedback system for motion management during simulation and treatment of radiation therapy patients. Methods: This video goggle system works by splitting and amplifying the video output signal directly from the Varian Real-Time Position Management (RPM) workstation or TrueBeam imaging workstation into two signals using a Distribution Amplifier. The first signal S[1] gets reconnected back to the monitor. The second signal S[2] gets connected to the input of a Video Scaler. The S[2] signal can be scaled, cropped and panned in real time to display only the relevant information to the patient. The output signal from the Video Scaler gets connected to an HDMI Extender Transmitter via a DVI-D to HDMI converter cable. The S[2] signal can be transported from the HDMI Extender Transmitter to the HDMI Extender Receiver located inside the treatment room via a Cat5e/6 cable. Inside the treatment room, the HDMI Extender Receiver is permanently mounted on the wall near the conduit where the Cat5e/6 cable is located. An HDMI cable is used to connect from the output of the HDMI Receiver to the video goggles. Results: This video goggle feedback system is currently being used at two institutions. At one institution, the system was just recently implemented for simulation and treatments on two breath-hold gated patients with 8+ total fractions over a two month period. At the other institution, the system was used to treat 100+ breath-hold gated patients on three Varian TrueBeam linacs and has been operational for twelve months. The average time to prepare the video goggle system for treatment is less than 1 minute. Conclusion: The video goggle system provides an efficient and reliable method to set up a video feedback signal for radiotherapy patients with motion management.

60 APPLIED LIFE SCIENCES↗

A Prospective Design Method for Nuclear Power: The Evaluation, Requirements, and Goals Outline for Nuclear (ERGON) Method

Human factors researchers at Idaho National Laboratory (INL) have worked on projects spanning control room modernization, operator support systems, visualization design, and novel system creation. These projects demonstrated the need for an explicit design method for nuclear power. Human factors teams found a high standard in the Human Factors Engineering Program Review Model (NUREG-0711) and needed a design methodology which could be successful in gaining approval. Previous work has been synthesized as the Evaluation, Requirements, and Goals Outline for Nuclear (ERGON) method here. Design tasks are broken into four phases: Context and Orientation, Human Factors Review, Prototyping and Evaluation, Iteration and Improvement. ERGON is intended as a flexible and direct design method for many applications in nuclear power. ERGON has been vetted through collaborative research and development with nuclear utilities and as such, the ERGON method can assist utilities to achieve approval from a NUREG-0711 summative evaluation for HSI implementations.

42 ENGINEERING↗

A unified approach to the classification of visual data systems.

Description of an approach to attaining a unified means of characterizing film, TV, and optical data systems. The concept is based on the premise that all of these imaging systems can be described by an equation similar to the ideal imaging system described by Rose (1948). This technique permits the direct comparison of film and TV performance without converting speed, film resolution lines, TV resolution lines, highlight output current and video bandwidth into compatible units, only to find some essential element of the conversion has been omitted from the particular specification in use. Most important, it permits system performance criteria to be based on input and output criteria without extensive manipulation of the elements between input and output.

Black, J.↗

Vision

Some data on human vision, important in present and projected space activities, are presented. Visual environment and performance and structure of the visual system are also considered. Visual perception during stress is included.

Taylor, J. H.↗

Multiplane binocular visual display system

Electro-optic system is interfaced with digital computer in flight simulator to generate simultaneous multiple-image planes in real time. System may have applications with other display and remote-control systems.

Chase, W. D.↗

Automatic visual inspection system for microelectronics

A system for automatically inspecting an integrated circuit was developed. A device for shining a scanning narrow light beam at an integrated circuit to be inspected and another light beam at an accepted integrated circuit was included. A pair of photodetectors that receive light reflected from these integrated circuits, and a comparing system compares the outputs of the photodetectors.

Micka, E. Z.↗

The 2RE J0241-525: A Nearby Post T-Tauri Visual Binary System

We present high spatial resolution X-ray observations, photometry and spectroscopy of the two low mass, active stars proposed as optical counterparts to the extreme ultraviolet source 2RE J0241-525 (equal to EUVE J0241-530). It is confirmed that both stars, which are of types dK7e and dM3e and separated by 22 arcsecs, are sources of soft X-ray emission and exhibit substantial chromospheric activity. Radial velocity measurements indicate that the two components are physically associated and most probably single. The projected equatorial velocities are measured as (75 +/- 3) km/s and (11.7 +/- 0.7) km/s for the hotter and cooler components, respectively, and whilst the hotter component has a relatively high photospheric lithium abundance, log N(Li) equal to 1.5 +/- 0.2, we are unable to detect any lithium in the cooler star. Isochrone fitting to this 'mini-cluster' yields an age of (3-70) Myr and a distance of (19-60) pc. An empirical comparison of the lithium abundances with those for similar stars in young clusters and associations narrows this age range to (5-30) Myr and a corresponding distance of (26-50) pc. We conclude that this object is a nearby post T-Tauri system, but we cannot locate any possible birth site. It appears unlikely that the system can have been ejected from a nearby open cluster in a two or three body encounter.

Jeffries, R. D.↗

Effects of Weightlessness on Vestibular Development: Summary of Research on NIH.R1

In our original application we proposed to investigate the effects of gravity on the formation of connections between the gravity receptors of the ear and the brain in rat pups raised in space beginning at an age before these connections are made until near the time of birth, when they are to some extent functional. We used the neuronal tracer, Dil, which could be applied to tissue obtained immediately after landing of the space shuttle, thus minimizing changes due to the earth's gravity. We hoped to determine whether the vestibular system develops in two phases, as do other sensory systems (such as the visual system). In these other systems the first phase of development is controlled genetically and the second phase is controlled by environmental stimulation. Our data collected strongly supports the idea that the vestibular system has these same two phases of development. The tissue obtained from the NIH.R1 experiment was of exceptionally high quality for our analysis. Therefore, we expanded our investigation into the ultrastructural effects of microgravity on vestibular development. For the sake of clarity we will subdivide our summary into two categories: (1) analysis of the branching pattern of axons between the vestibular nerve and the gravistatic receptors of the ear in flight and control animals, and (2) analysis of the branching pattern of axons between the vestibular nerve and the brain in flight and control animals.

Fritzsch, Bernd↗

A Visual Database System for Image Analysis on Parallel Computers and its Application to the EOS Amazon Project

The goal of this task was to create a design and prototype implementation of a database environment that is particular suited for handling the image, vision and scientific data associated with the NASA's EOC Amazon project. The focus was on a data model and query facilities that are designed to execute efficiently on parallel computers. A key feature of the environment is an interface which allows a scientist to specify high-level directives about how query execution should occur.

Shapiro, Linda G.↗

The effects of spaceflight on open-loop and closed-loop postural control mechanisms: human neurovestibular studies on SLS-2

Stabilogram-diffusion analysis was used to examine how prolonged periods in microgravity affect the open-loop and closed-loop postural control mechanisms. It was hypothesized that following spaceflight: (1) the effective stochastic activity of the open-loop postural control schemes in astronauts is increased; (2) the effective stochastic activity and uncorrelated behavior, respectively, of the closed-loop postural control mechanisms in astronauts are increased; and (3) astronauts utilized open-loop postural controls schemes for shorter time intervals and smaller displacements. Four crew members and two alternates from the 14-day Spacelab Life Sciences 2 Mission were included in the study. Each subject was tested under eyes-open, quiet-standing conditions on multiple preflight and postflight days. The subjects' center-of-pressure trajectories were measured with a force platform and analyzed according to stabilogram-diffusion analysis. It was found that the effective stochastic activity of the open-loop postural control schemes in three of the four crew members was increased following spaceflight. This result is interpreted as an indication that there may be in-flight adaptations to higher-level descending postural control pathways, e.g., a postflight increase in the tonic activation of postural muscles. This change may also be the consequence of a compensatory (e.g., "stiffening") postural control strategy that is adopted by astronauts to account for general feeling of postflight unsteadiness. The crew members, as a group, did not exhibit any consistent preflight/postflight differences in the steady-state behavior of their closed-loop postural control mechanisms or in the functional interaction of their open-loop and closed-loop postural control mechanisms. These results are interpreted as indications that although there may be in-flight adaptations to the vestibular system and/or proprioceptive system, input from the visual system can compensate for such changes during undisturbed stance.

NASA Program Flight↗

Galfenol Tactile Sensor Array and Visual Mapping System

The smart material, Galfenol, is being explored for its uses as a magnetostrictive material. This project seeks to determine if Galfenol can be used as a tactile sensor in a 2-D grid array, magnetic circuit system. When used within a magnetic circuit, Galfenol indicates induced stress and force as a change in flux, due to a change in permeability of the material. The change in flux is detected by Giant MagnetoResistive (GMR) Sensors, which produce a voltage change proportional to the field change. By using Galfenol in an array, this research attempts to create a sensory area. Galfenol is an alloy made of Iron and Gallium. FexGax, where 15 less than or equal to x less than or equal to 28, creates a material with useful mechanical and transduction attributes (Clark et al and Kell). Galfenol is also distinguished by the crystalline structure of the material. Two types currently exist: single crystal and polycrystalline. Single crystal has higher transduction coefficients than polycrystalline, but is more costly. Polycrystalline Galfenol is currently available as either production or research grade. The designations are related to the sample growth rate with the slower rate being the research grade. The slower growth rate more closely resembles the single crystal Galfenol properties. Galfenol 17.5- 18% research grade is used for this experiment, provided by Etrema Products Inc. The magnetic circuit and sensor array is first built at the macro scale so that the design can be verified. After the macro scale is proven, further development will move the system to the nano-level. Recent advances in nanofabrication have enabled Galfenol to be grown as nanowires. Using the nanowires, research will seek to create high resolution tactile sensors with spatial resolutions similar to human finger tips, but with greater force ranges and sensitivity capabilities (Flatau & Stadler). Possible uses of such systems include robotics and prosthetics.

Hale, Kathleen↗