Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENTILATION SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Curation of Ground-Truth Validated Benchmarking Datasets for Fault Detection & Diagnostics Tools

Fault detection and diagnostics (FDD) analytical tools for heating, ventilation and air conditioning (HVAC) systems represent one of the most active areas of smart building technology development. A diversity of techniques is used for FDD analytics, spanning physical models, black box, and rule-based approaches, and researchers continuously strive to develop improved algorithms. With FDD algorithm numbers now in the hundreds, there is a need for performance evaluation of these algorithms in order to assess improvements, improve costeffectiveness, and to prioritize investment in the further development of these technologies. A persistent challenge of FDD advance has been the lack of common datasets to benchmark the performance accuracy of FDD algorithms. This paper summarizes the successful curation of HVAC operational data, paired with validated ground-truth information regarding the presence and absence of faults. The current dataset, consisting of both simulation and experimental data, will evolve to include a larger set of HVAC systems with the objective of creating the largest publicly available dataset to be used by FDD developers, users, and researchers to compare and contrast performance accuracy across FDD algorithms, helping to drive improvements that will spur greater market adoption of FDD tools. Furthermore, in order to avoid previously observed issues with contributed datasets and ensure high quality and consistency of future submissions, the development of data validation and ground-truth assessment protocol is detailed in this study.

Casillas, Armando↗

National Park Service Bus Electrification Study: 2020 Report

This report summarizes important considerations for implementing BEBs in the three national park fleets, detailing information about current buses at each fleet, electric bus demonstration vehicles, as well as performance evaluations of BEBs in Zion, Bryce, and Yosemite. Results include in-use data collection results reporting metrics such as average bus speed, energy usage per trip, and daily distance traveled, as well as effects of high heating, ventilation, and air conditioning (HVAC) system use to both heat and cool the buses, emissions estimations before and after use of electric buses, operating costs, electric vehicle infrastructure, maintenance, and bus driver user experience survey information. Analysis results from this project will help the NPS understand how BEBs and future expansion of BEBs could assist in meeting their bottom line and operational goals and assist NPS in choosing appropriate locations for future BEB deployments.

33 ADVANCED PROPULSION SYSTEMS↗

Impact of Mass Wood Walls on Building Energy Use, Peak Demand, and Thermal Comfort

Thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours. Cross-Laminated Timber (CLT) and other mass wood products provide thermal mass to the building envelope in a lighter and more environmentally friendly form than concrete. However, the influence of CLTs on heating and cooling energy, peak energy demand, and the indoor climate is not well-known. This project was formed to find the energy efficiency benefits of mass timber structures. The objectives were to (1) test the thermal performance of insulated mass wall structures in controlled laboratory conditions, (2) validate simulation models to expand performance to natural climatic conditions, (3) isolate the impact of the thermal properties of wood (thermal mass, thermal conductivity, moisture storage) on heating and cooling energy use and peak energy demand, and to optimize the performance. Currently, the designs used for CLT buildings have focused on structural and fire issues, and they do not consider the thermal mass benefits. Therefore, the thermal performance is not necessarily optimized.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Human-in-the-loop Sensing and Control for Commercial Building Energy Efficiency and Occupant Comfort

Most of the existing heating, ventilation and air conditioning (HVAC) systems in commercial buildings operate in a conservative manner by assuming maximum occupancy in each room during pre-specified periods of the week, leading to significant energy being wasted as rooms are over-conditioned compared to the actual requirements of the occupants. Though critical, our understanding of occupancy patterns and thermal comfort needs of the occupants in commercial buildings is lacking and it is well known that both of these quantities are stochastic and time-varying, thus requiring sensing solutions to estimate them. This project had the goal of designing, implementing and evaluating a hardware and software solution to ameliorate this challenge. In particular, a depth camera (one whose pixels reveal distance from the camera as opposed to color values) placed on doorways is used to detect entrance and exit events from thermal zones in the building, and thereby estimate their occupancy levels. This information is then fed to a novel control algorithm that can, through interactions with the HVAC system, learn how to provide control inputs that maximize comfort and minimize energy waste. The resulting system represents a significant improvement over existing controllers for commercial HVAC systems and allowed us to improve our understanding of the design of future human-in-the-loop control solutions. For this solution to be feasible, the project had target metrics for its performance and cost. In particular, entrance and exit events for occupants moving about the building would need to be detected with an accuracy higher than 97%; and the resulting control inputs derived from this information would need to lead to approximately 10% energy savings compared to a schedule-based controller. Furthermore, regarding the final hardware design, the project had a target bill of materials (BOM) cost for the sensing solution of less than US$200 per unit while using less than 25W of power on average. All of these target metrics were met or exceeded by our final proposed solution. We performed evaluations by deploying the system in over 20 rooms of different types across 6 commercial buildings in Pittsburgh, PA over the course of three years, and performing targeted controlled experiments to test its performance along the different metrics. The human-in-the-loop control solutions (both hardware and software) developed through this project are expected to lead to significant improvements in the comfort and energy efficiency of HVAC systems used in commercial buildings. The insights we developed through the project pave the way to HVAC systems that can condition interior spaces according to their real-time utilization and the thermal comfort needs of the occupants, thereby reducing energy use. They also open up a new learning-based way of configuring HVAC controllers without having to manually fine-tune them for each building. These innovations can significantly increase the adoption of novel control solutions by the industry and thereby save resources and reduce costs of operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Skewering the silos: using Brick to enable portable analytics, modeling and controls in buildings

Nearly all large commercial buildings have heating, ventilation and air conditioning (HVAC) systems, lighting systems, safety and other systems controlled by a computer—a dedicated server with a building energy management system (BMS). However, these BMSs are proprietary with each building’s assets (that is, fans, valves, pumps, and their setpoints) named and coded uniquely by the BMS vendor or engineer; building analytics and control algorithms are written specific to the assets and the building. Thus, any control updates or analytics to improve building performance—especially critical to reduce greenhouse emissions or improve load flexibility—are labor intensive and costly. The Brick schema was developed so the same analysis or control algorithms can work on a variety of buildings if each is digitally represented in a Brick data model. The goal of this project was to further the development of Brick to extend it beyond an academic project with demonstrated success in a small field study, to a practical choice for industrial and commercial stakeholders seeking to realize value from building data. To do this, we executed four objectives: (1) expand the Brick schema including its modeling capabilities and vocabulary, (2) develop tools for integrating Brick with existing digital technologies and representations in buildings, (3) develop an open-source analytics platform to facilitate use of Brick in delivering data value, and (4) demonstrate Brick-driven analytics and controls in real settings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Stock Segmentation for Decarbonization Planning

This document discusses the development of a segmentation approach for the U.S. commercial building stock that is focused on identifying similarities that align with common decarbonization strategies. The resulting nine-segment approach primarily uses similarities in heating, ventilation, and air conditioning (HVAC) systems, service water heating systems, and presence of cooking equipment to separate buildings into categories.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of thermally anisotropic building envelopes with TES and advanced controls to tailor HVAC loads

Heating, ventilation, and air conditioning (HVAC) systems are the primary energy consumers in buildings to meet heating or cooling energy demands. The building envelope can play an active role in reducing this demand and associated costs by collecting thermal energy naturally available, such as diurnal temperature swings, solar irradiance, and night sky radiation cooling, to offset heating and cooling loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hot, Cold, or Just Right? Using a Wide-View Infrared Biometric Sensor to Improve Occupant Comfort and Reduce Overcooling in Buildings via Closed-loop Control (CRADA Final Report)

This research adds to the understanding of building energy management by fundamentally challenging the long-standing paradigm of controlling an environmental parameter—air temperature—and assuming occupant comfort will follow. The project developed and demonstrated a novel approach that directly senses physiological indicators of human comfort to enable closedloop, human-centric control of heating, ventilation, and air conditioning (HVAC) systems. This work shifts the focus from open-loop environmental control to a closed-loop system that prioritizes the occupants' actual thermal state. The primary benefit to the public is the potential for a simultaneous improvement in the quality of indoor environments, where people spend most of their time, and a significant reduction in national energy consumption. Overcooling, or the overuse of cooling energy in a way that discomforts occupants, wastes approximately 0.5 Quads of primary energy annually in U.S. commercial buildings and creates unproductive indoor environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Wireless Power Technology for Use in Electrochromic Window Retrofit Applications

Electrochromic (EC) windows, often referred to as smart windows, have the ability to adjust their tint in response to electrical signals, thereby controlling the amount of sunlight and heat entering a building. This dynamic modulation can lead to significant energy savings by reducing the reliance on artificial lighting and minimizing the load on heating, ventilation, and air conditioning (HVAC) systems. However, the widespread adoption of electrochromic window technology, especially in existing buildings, faces challenges, particularly concerning the installation cost associated with the need for electrical wiring to power and control the EC glass (tinting). In this project, GuRu Wireless demonstrated that it’s mmWave-based wireless power energy transfer technology can provide the necessary power for operation of electrochromic windows, wirelessly, and address the wiring challenges of electrochromic windows in retrofit applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercial Building HVAC Technology Challenge - Carrier (Final Report)

The purpose of this Cooperative Research and Development Agreement (CRADA) was to test two rooftop commercial heating, ventilation, and air conditioning (HVAC) systems supplied by Carrier Corporation to determine if they met the laboratory test requirements of the United States Department of Energy (DOE) Commercial Building HVAC Technology Challenge (hereafter noted as “the Challenge”). Results of the laboratory testing completed at Oak Ridge National Laboratory (ORNL) demonstrated that the systems met all requirements of the Challenge. Carrier Corporation has successfully completed this aspect of the Challenge. This CRADA report will briefly describe the Challenge, the test plan created to measure the success of systems provided by Challenge participants, and the results of laboratory testing of the Carrier commercial rooftop systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗

A multi-scale time-series dataset of anthropogenic heat from buildings in Los Angeles County

The dataset contains hourly Anthropogenic heat (AH) from buildings in Los Angeles County, based on weather data from 2018. The hourly AH is aggregated at three spatial resolutions: 450m x 450m grid, 12km x 12km grid, and census tract. The AH is broken down into three components: building envelope surface convection, heating, ventilation, and air conditioning (HVAC) system heat release, and zone exfiltration and exhaust air heat loss. The dataset is created with the physics-based EnergyPlus building energy models to calculate individual buildings' AH considering WRF-UCM simulated microclimate conditions. Please refer to the paper "A multi-scale time-series dataset of anthropogenic heat from buildings in Los Angeles County" for more information about the data generation workflow and the data validation procedure. The data set contains two folders: the "output_data" folder holds the simulation results (EP_output and EP_output_csv), building metadata (building_metadata.geojson and building_metadata.csv), aggregated heat emission and energy consumption time-series data (hourly_heat_energy), and geographical data (geo_data) associated with the GEOID referenced in heat and energy consumption data. The "input_data" folder contains the raw data used to generate files in the "output_data" folder as well as data sets used in the validation. The code repository (https://github.com/IMMM-SFA/xu_etal_2022_sdata) holds the processing scripts for data curation, validation, and visualization.

Energy↗

Advanced Frost Sensor for HVAC Applications

Frost is a common problem in heating, ventilation, and air conditioning (HVAC) systems that can degrade their efficiencies, leading to excessive electricity consumption. Appropriate defrosting is therefore essential for heat pumps and refrigeration systems. However, these systems typically run the defrost cycle based on a predetermined time interval, a method that does not accurately identify the amount of frost and thus consume excessive electricity. To substantially improve defrosting initiation and termination, this paper describes development of a smart sensor based on a capacitive sensing technique that can quantify frost accumulation and difference between frost, ice, and water. The reported sensor adopts interdigitated comb electrodes and can be updated to a potential multifunctional sensor array for the enhancing identification of frost, ice, and water with the integrated measurement of surface temperature, frost capacitance, and resistance. The proposed frost sensor is potentially expected to have widespread applications in HVAC systems, including heat pumps, refrigerators, and commercial refrigeration systems.

Gao, Zhiming↗

Energy Demand Management in Buildings Using PCM-Integrated Wall

The buildings in the United States annually consume nearly 40% of total U.S. energy consumption and approximately 75% of U.S. electricity consumption. Almost half of the total U.S. energy consumption in buildings is attributed to the space conditioning through Heating, Ventilation, and Air Conditioning (HVAC) systems. Utilizing thermal energy storage in buildings, particularly integrating phase change material (PCM) in the walls, has been reported to be an effective method of managing the space heating and cooling loads. This presentation covers an in-depth discussion on the integration of a PCM to building walls, the key conditions required for effective utilization of the PCM, and effect of the PCM transition temperature and the PCM location on energy-saving potential of the PCM-integrated wall.

building↗

Validation of HVAC Hardware-in-the-Loop Simulation for Advanced Control Strategies in Smart Homes: Preprint

Residences with smart thermostats can use advanced control strategies to manage their cooling/heating demand, but it is difficult to evaluate optimal control strategies for flexible heating, ventilation, and air conditioning (HVAC) systems in a traditional laboratory setting. The HVAC hardware-in-the-loop (HIL) system combines physical HVAC equipment and a physical thermostat with a simulated house to enable realistic operation of the hardware in any climate. This HIL platform allows researchers to evaluate advanced control strategies for homes with different construction or vintage types, as well as different climates and occupancy schedules. To demonstrate the capabilities of the HVAC HIL system, experimental results with a SEER 16, HSPF 9.5, 3 ton single-speed air source heat pump are validated against past field data collected from a heavily instrumented, unoccupied, retrofit house located in Sacramento, California. Three different cooling strategies are recreated in the HVAC HIL platform, including two different pre-cooling schedules that were designed to shift energy use away from the evening peak. The room temperatures, heat pump energy use, and run time show good agreement between the field data and HIL experimental results for three strategies.

cooling strategies↗

Multi-Fidelity Modeling and Control for Building Temperature Control

The ability to control energy loads such as a building's heating, ventilation, and air conditioning (HVAC) system can help facilitate increased penetration of variable renewable energy sources into the electric grid. To be able to control these HVAC systems more effectively, detailed simulations of the corresponding building physics is becoming increasingly important. These detailed simulations can be complex, nonlinear, and can require immense computational power when used in an advanced control method such as model predictive control (MPC), prompting the need to explore less computationally intensive strategies. In this work, a multi-fidelity approach is proposed to combine samples from a complex, high-fidelity model with a simple, low-fidelity model within the MPC control loop. More specifically, the parameters of a reduced-order, linear building model are periodically updated with knowledge from its high-fidelity counterpart - an EnergyPlus model - in an online fashion using a Gaussian Process surrogate model. Hence, highly accurate predictions of current and future conditions in a building are maintained with a substantially reduced computational burden compared to using the high-fidelity models alone. In other words, this linear parameter varying model preserves the low computational requirements of a low-order linear model while accurately modeling a building's dynamics. This allows a building controller to take highly informed actions without requiring a large computational budget.

building modeling↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗