Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENTILATION SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

Requirements and Sizing Investigation for Constellation Space Suit Portable Life Support System Trace Contaminant Control

The Trace Contaminant Control System (TCCS), located within the ventilation loop of the Constellation Space Suit Portable Life Support System (PLSS), is responsible for removing hazardous trace contaminants from the space suit ventilation flow. This paper summarizes the results of a trade study that evaluated if trace contaminant control could be accomplished without a TCCS, relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Trace contaminant generation rates were revisited to verify that values reflect the latest designs for Constellation Space Suit System (CSSS) pressure garment materials and PLSS hardware. Additionally, TCCS sizing calculations were performed and a literature survey was conducted to review the latest developments in trace contaminant technologies.

Paul, Heather L.↗

Creating the Environment for Exploration Habitats

The Crew and Thermal Systems Division’s (CTSD) 20 Foot Chamber has undergone significant modifications to support NASA’s future human exploration missions to the Moon, Mars, and beyond. Existing chamber systems such as Vacuum/Repress, Heating Ventilation and Air Conditioning (HVAC), and Fire Suppression System (FSS), were upgraded, while new systems such as Air Revitalization and Gas Distribution were added. In addition, the chamber was outfitted with crew quarters, hygiene areas, storage, and workspaces. Teams across the Johnson Space Center (JSC) worked together to overcome the logistical and operational challenges of the planned test parameters. The ultimate goal was to create an analog testbed in which a maximum of 8 human test subjects could safely live and work for at least 11 days in the same conditions (reduced pressures, Oxygen concentrations, etc.) as those expected inside a base spacecraft. This would allow researchers to study the effects of such environments on humans and to validate proposed Prebreathe Protocols to enable the safe performance of surface extravehicular activities (EVAs). Over the last eighteen months, the CTSD Systems Test Branch has performed six tests of varying lengths and atmospheres for both NASA and commercial partners. To date, researchers now have collected data on 48 test subjects in the course of 42 days and over 130 simulated EVAs. This paper will discuss the history of the 20 Foot Chamber, its long road to becoming an analog testbed for human exploration, and the capabilities that make it a unique, world class facility for NASA and commercial human exploration missions. It will provide an overview of past and future testing, and the lessons learned along the way.

Cristina Aurora Anchondo↗

Creating the Environment for Exploration Habitats

The Crew and Thermal Systems Division’s (CTSD) 20 Foot Chamber has undergone significant modifications to support NASA’s future human exploration missions to the Moon, Mars, and beyond. Existing chamber systems such as Vacuum/Repress, Heating Ventilation and Air Conditioning (HVAC), and Fire Suppression System (FSS), were upgraded, while new systems such as Air Revitalization and Gas Distribution were added. In addition, the chamber was outfitted with crew quarters, hygiene areas, storage, and workspaces. Teams across the Johnson Space Center (JSC) worked together to overcome the logistical and operational challenges of the planned test parameters. The ultimate goal was to create an analog testbed in which a maximum of 8 human test subjects could safely live and work for at least 11 days in the same conditions (reduced pressures, Oxygen concentrations, etc.) as those expected inside a base spacecraft. This would allow researchers to study the effects of such environments on humans and to validate proposed Prebreathe Protocols to enable the safe performance of surface extravehicular activities (EVAs). Over the last eighteen months, the CTSD Systems Test Branch has performed six tests of varying lengths and atmospheres for both NASA and commercial partners. To date, researchers now have collected data on 48 test subjects in the course of 42 days and over 130 simulated EVAs. This paper will discuss the history of the 20 Foot Chamber, its long road to becoming an analog testbed for human exploration, and the capabilities that make it a unique, world class facility for NASA and commercial human exploration missions. It will provide an overview of past and future testing, and the lessons learned along the way.

Cristina A Anchondo↗

Creating the Test Environment for Exploration Habitats

The Crew and Thermal Systems Division’s (CTSD) 20 Foot Chamber has undergone significant modifications to support NASA’s future human exploration missions to the Moon, Mars, and beyond. Existing chamber systems such as Vacuum/Repress, Heating Ventilation and Air Conditioning (HVAC), and Fire Suppression System (FSS), were upgraded, while new systems such as Air Revitalization and Gas Distribution were added. In addition, the chamber was outfitted with crew quarters, hygiene areas, storage, and workspaces. Teams across the Johnson Space Center (JSC) worked together to overcome the logistical and operational challenges of the planned test parameters. The ultimate goal was to create an analog testbed in which a maximum of eight human test subjects could safely live and work for at least 11 days in the same conditions (e.g., reduced pressures, oxygen concentrations, and so on) as those expected inside a base spacecraft. This would allow researchers to study the effects of such environments on humans and to validate proposed Prebreathe Protocols to enable the safe performance of surface extravehicular activities (EVAs). Over the last 18 months, the CTSD Systems Test Branch has performed six tests of varying lengths and atmospheres for both NASA and commercial partners. To date, researchers now have collected data on 48 test subjects in the course of 42 days and over 130 simulated EVAs. This paper will discuss the history of the 20 Foot Chamber, its long road to becoming an analog testbed for human exploration, and the capabilities that make it a unique, world class facility for NASA and commercial human exploration missions. It will provide an overview of past and future testing and the lessons learned along the way.

Cristina A Anchondo↗

Creating the Test Environment for Exploration Habitats

The Crew and Thermal Systems Division’s (CTSD) 20 Foot Chamber has undergone significant modifications to support NASA’s future human exploration missions to the Moon, Mars, and beyond. Existing chamber systems such as Vacuum/Repress, Heating Ventilation and Air Conditioning (HVAC), and Fire Suppression System (FSS), were upgraded, while new systems such as Air Revitalization and Gas Distribution were added. In addition, the chamber was outfitted with crew quarters, hygiene areas, storage, and workspaces. Teams across the Johnson Space Center (JSC) worked together to overcome the logistical and operational challenges of the planned test parameters. The ultimate goal was to create an analog testbed in which a maximum of eight human test subjects could safely live and work for at least 11 days in the same conditions (e.g., reduced pressures, oxygen concentrations, and so on) as those expected inside a base spacecraft. This would allow researchers to study the effects of such environments on humans and to validate proposed Prebreathe Protocols to enable the safe performance of surface extravehicular activities (EVAs). Over the last 18 months, the CTSD Systems Test Branch has performed six tests of varying lengths and atmospheres for both NASA and commercial partners. To date, researchers now have collected data on 48 test subjects in the course of 42 days and over 130 simulated EVAs. This paper will discuss the history of the 20 Foot Chamber, its long road to becoming an analog testbed for human exploration, and the capabilities that make it a unique, world class facility for NASA and commercial human exploration missions. It will provide an overview of past and future testing and the lessons learned along the way.

Chris Briggs↗

Advanced life support study

Summary reports on each of the eight tasks undertaken by this contract are given. Discussed here is an evaluation of a Closed Ecological Life Support System (CELSS), including modeling and analysis of Physical/Chemical Closed Loop Life Support (P/C CLLS); the Environmental Control and Life Support Systems (ECLSS) evolution - Intermodule Ventilation study; advanced technologies interface requirements relative to ECLSS; an ECLSS resupply analysis; the ECLSS module addition relocation systems engineering analysis; an ECLSS cost/benefit analysis to identify rack-level interface requirements of the alternate technologies evaluated in the ventilation study, with a comparison of these with the rack level interface requirements for the baseline technologies; advanced instrumentation - technology database enhancement; and a clean room survey and assessment of various ECLSS evaluation options for different growth scenarios.

Source record↗

The De-Icing Comparison Experiment (D-ICE): a study of broadband radiometric measurements under icing conditions in the Arctic

Abstract. Surface-based measurements of broadband shortwave (solar) and longwave (infrared) radiative fluxes using thermopile radiometers are made regularly around the globe for scientific and operational environmental monitoring. The occurrence of ice on sensor windows in cold environments – whether snow, rime, or frost – is a common problem that is difficult to prevent as well as difficult to correct in post-processing. The Baseline Surface Radiation Network (BSRN) community recognizes radiometer icing as a major outstanding measurement uncertainty. Towards constraining this uncertainty, the De-Icing Comparison Experiment (D-ICE) was carried out at the NOAA Atmospheric Baseline Observatory in Utqiaġvik (formerly Barrow), Alaska, from August 2017 to July 2018. The purpose of D-ICE was to evaluate existing ventilation and heating technologies developed to mitigate radiometer icing. D-ICE consisted of 20 pyranometers and 5 pyrgeometers operating in various ventilator housings alongside operational systems that are part of NOAA's Barrow BSRN station and the US Department of Energy Atmospheric Radiation Measurement (ARM) program North Slope of Alaska and Oliktok Point observatories. To detect icing, radiometers were monitored continuously using cameras, with a total of more than 1 million images of radiometer domes archived. Ventilator and ventilator–heater performance overall was skillful with the average of the systems mitigating ice formation 77 % (many >90 %) of the time during which icing conditions were present. Ventilators without heating elements were also effective and capable of providing heat through roughly equal contributions of waste energy from the ventilator fan and adiabatic heating downstream of the fan. This provided ∼0.6 ∘C of warming, enough to subsaturate the air up to a relative humidity (with respect to ice) of ∼105 %. Because the mitigation technologies performed well, a near complete record of verified ice-free radiometric fluxes was assembled for the duration of the campaign. This well-characterized data set is suitable for model evaluation, in particular for the Year of Polar Prediction (YOPP) first Special Observing Period (SOP1). We used the data set to calculate short- and long-term biases in iced sensors, finding that biases can be up to +60 W m−2 (longwave) and −211 to +188 W m−2 (shortwave). However, because of the frequency of icing, mitigation of ice by ventilators, cloud conditions, and the timing of icing relative to available sunlight, the biases in the monthly means were generally less than the aggregate uncertainty attributed to other conventional sources in both the shortwave and longwave.

54 ENVIRONMENTAL SCIENCES↗

Stochastic Home Energy Management Systems with Varying Controllable Resources

This paper studies the performance of a model predictive control (MPC) algorithm in a home energy management system (HEMS) as the set of controllable resources varies and under both a constant and a time-of-use (TOU) electricity price structure. The set of controllable resources includes residentially-owned photovoltaic (PV) panels, a home battery system (HBS), an electric vehicle (EV), and a home heating, ventilation, and air conditioning (HVAC) system. The HEMS optimally schedules the set of controllable resources given user preferences such as indoor thermal comfort and electricity cost sensitivity. The home energy management system is built on a chance constrained, MPC-based algorithm, where the chance constraint ensures the indoor thermal comfort is satisfied with a high probability given uncertainty in the outdoor temperature and solar irradiance forecasts. Simulation results for varying sets of controllable resources under two different electricity price structures demonstrate the variation in the HEMS control with respect to HBS operation, electricity cost, and grid power usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A framework for calibrating and validating an air loop dynamic model in an HVAC system in Modelica

The use of Modelica for simulating the dynamic behaviors of building heating, ventilation, and air conditioning (HVAC) systems has gained popularity. Calibration of a model that represents large and complex HVAC systems in Modelica involves the determination of hundreds of parameters using real-world operation data. Considering the coupling effects among various components, such a calibration process is complex and time-consuming. In this study, we propose a systematic framework to efficiently calibrate and validate a complex HVAC system model in Modelica. The framework includes strategies to solicit real-system operation data and to decouple the model. The goal of this calibration framework is to accurately and efficiently determine a set of Modelica model parameters that provide a good match between the simulated and real system behaviors. To demonstrate the validity of the framework, it was applied to calibrate the parameters of a Modelica model of the air loop subsystem of a real AHU-VAV system. The results show that the calibrated model can generate simulated results, including VAV air flow rate, outdoor air flow, and fan power consumption, that match well with the operational data of the real system. The coefficient of the variation of the root mean square error, CV(RMSE), of the air flow rate and power consumption are 14.6 % and 11.5 %, respectively. The results prove that the framework is valid and effective, and it can be used to calibrate other complex HVAC system Modelica models in the future.

Li, Yicheng↗

ECLSS and Thermal Systems Integration Challenges Across the Constellation Architecture

As the Constellation Program completes its initial capability Preliminary Design Review milestone for the Initial Capability phase, systems engineering of the Environmental Control and Life Support (ECLS) and Thermal Systems for the various architecture elements has progressed from the requirements to design phase. As designs have matured for the Ares, Orion, Ground Systems, and Extravehicular (EVA) System, a number of integration challenges have arisen requiring analyses and trades, resulting in changes to the design and/or requirements. This paper will address some of the key integration issues and results, including the Orion-to-Ares shared compartment venting and purging, Orion-to-EVA suit loop integration issues with the suit system, Orion-to-ISS and Orion-to-Altair intermodule ventilation, and Orion and Ground Systems impacts from post-landing environments.

Carrasquillo, Robyn↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Analysis and Design of Crew Sleep Station for ISS

This paper details the analysis and design of the Temporary Sleep Station (TeSS) environmental control system for International Space Station (ISS). The TeSS will provide crewmembers with a private and personal space, to accommodate sleeping, donning and doffing of clothing, personal communication and performance of recreational activities. The need for privacy to accommodate these activities requires adequate ventilation inside the TeSS. This study considers whether temperature, carbon dioxide, and humidity within the TeSS remain within crew comfort and safety levels for various expected operating scenarios. Evaluation of these scenarios required the use and integration of various simulation codes. An approach was adapted for this study, whereby results from a particular code were integrated with other codes when necessary. Computational Fluid Dynamics (CFD) methods were used to evaluate the flow field inside the TeSS, from which local gradients for temperature, velocity, and species concentration such as CO (sub 2) could be determined. A model of the TeSS, containing a human, as well as equipment such as a laptop computer, was developed in FLUENT, a finite-volume code. Other factors, such as detailed analysis of the heat transfer through the structure, radiation, and air circulation from the TeSS to the US Laboratory Aisle, where the TeSS is housed, were considered in the model. A complementary model was developed in G189A, a code which has been used by NASA/JSC for environmental control systems analyses since the Apollo program. Boundary conditions were exchanged between the FLUENT and G189A TeSS models. G189A provides human respiration rates to the FLUENT model, while the FLUENT model provides local convective heat transfer coefficients to G189A model. An additional benefit from using an approach with both a systems simulation and CFD model, is the capability to verify the results of each model by comparison to the results of the other model. The G189A and FLUENT models were used to evaluate various ventilation designs for the TeSS over a range of operating conditions with varying crew metabolic load, equipment operating modes, ventilation flow rates, and with the TeSS doors open and closed. Results from the study were instrumental in the optimization of a design for the TeSS ventilation hardware. A special case was considered where failure of the TeSS ventilation system occurred. In this case, a study was conducted in order to determine the time required for the CO (sub 2) concentration inside the TeSS to increase to ISS limit values under transient conditions. A lumped-capacitance code, SINDA-FLUINT was used in this case to provide accurate predictions of the human reaction to the TeSS cabin conditions including core and skin temperatures and body heat storage. A simple two-dimensional CFD model of a crewmember inside the TeSS was developed in FLUENT in order to determine the volume envelope of the respired air from the human, which maintained a minimum velocity profile. This volume was then used in the SINDA-FLUINT model to facilitate the calculations of CO (sub 2) concentrations, dry bulb temperatures and humidity levels inside the TeSS.

Keener, John F.↗

An encoder–decoder LSTM-based EMPC framework applied to a building HVAC system

Numerous studies have demonstrated the benefit of economic model predictive control (EMPC) applied to building heating, ventilation, and air conditioning (HVAC) systems. However, the construction and training of predictive models for building HVAC systems are widely recognized as a key technological barrier preventing large-scale adoption of EMPC for buildings. In this work, an encoder–decoder long short-term memory-based EMPC framework is developed. The key advantage of the approach is that a model may be automatically generated from a list of inputs and outputs. From the definition of inputs and outputs, the constructed model may be trained and automatically embedded into the EMPC framework for real-time estimation and control. The overall end-to-end EMPC framework from model training to on-line estimation and control are described. To this end, the encoder–decoder model provides a natural framework for state estimation (encoder), which is required to provide an initial condition for the predictive model of EMPC (decoder). Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated closed-loop system consists of a building zone from a multi-zone building, which is served by an air handling unit-variable air volume HVAC system. For the HVAC example considered, the trained encoder–decoder model can predict the indoor air temperature and HVAC sensible cooling rate of a building zone over a two-day horizon with high accuracy. Overall, we find that considering a time-of-use electric rate structure, the EMPC, which manipulates the zone temperature setpoint, can reduce the HVAC power consumption cost relative to keeping the zone temperature setpoint at its maximum value (i.e., minimum energy approach).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HVAC System Performance for Energy Codes (Technical Brief)

The prescriptive path is likely the most widely used approach for commercial code compliance in the United States. Though easy to implement, the prescriptive approach does not discriminate between high-performing and poorly performing heating, ventilation, air conditioning (HVAC) system configurations that are both minimally compliant. To meet aggressive energy and carbon reduction goals, energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. HVAC System Performance is a discipline performance path and provides a simpler solution to HVAC system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution that could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A web-based calculation tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach has also been evaluated by the ASHRAE Standard 90.1 Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive Control for Residential HVAC Systems to Support Grid Services

In this paper, we propose an adaptive control strategy for residential buildings' heating ventilation and air conditioning (HVAC) systems to support grid services. The proposed control strategy captures the time-varying characteristics of the building and weather environments. It assigns to each building a local controller to maintain the indoor temperature within a desired comfort level, while the load aggregator allocates the assigned reference power provided by the distribution system operator to support a specific grid service, such as demand peak reduction, balancing supply and demand, and consuming the solar photovoltaic (PV) power locally. Simulation results are presented to verify the performance of the proposed control strategy in terms of maintaining the indoor temperatures of several buildings within the desired comfort bands while tracking the reference power profile. Also, a comparison with a recently developed model-free control strategy is presented.

Wu, Tumin↗