SEARCH · Engineering Papers
Results for “VALID”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Chapter 10: An Introduction to Some Model Validation Concepts and Paradigms and the Real-Space Approach to Model Validation.
Abstract not provided.
Validation Assessment of Hypersonic Double-Cone Flow Simulations using UQ Sensitivity Analysis and Validation Metrics.
Abstract not provided.
Introduction to the Real Space Model Validation Approach and Its Advantages vs. the ASME VV10 and VV20 Validation Approaches.
Abstract not provided.
HE Validation Suite (HEVS): An automated approach to verify and validate HE models.
Explore the source record for details and available documents.
Integrated behavior-based infrastructure command validation
A cybersecurity infrastructure command validation system is provided herein for validating asset commands issued within an infrastructure network. The cybersecurity infrastructure command validation system can be integrated into an infrastructure network to monitor and validate infrastructure asset commands in real-time or while the infrastructure network is active. The cybersecurity infrastructure command validation system can receive or intercept commands issued by asset controllers. The cybersecurity infrastructure command validation system can validate the commands based on a command validation model. The command validation model can represent normal operating behavior of the infrastructure network. The cybersecurity infrastructure command validation system can provide valid commands to the intended infrastructure asset, or can reject invalid commands. The cybersecurity infrastructure command validation system can store validation results for use in updating the command validation model. The cybersecurity infrastructure command validation system can flag or otherwise warn the infrastructure network or administrators of invalid commands.
VADER: A Tool for Criticality Safety Validation
The purpose of criticality safety is to prevent any inadvertent criticality from occurring during the handling or storage of fissile material. Calculations are frequently used to demonstrate that a sufficient subcritical margin exists. Validation is a key aspect of the evaluation process, establishing the suitability, accuracy, and associated uncertainty of the computational method and data to be used for the intended application. The validation process is performed by comparing the results of critical experiments with the calculated results from models of the experiments using the computational method to be validated. Laboratory critical experiments are controlled systems that achieve a k eff of approximately 1 in order to investigate the parameters at which such a critical condition is achieved. The validation parameters that are traditionally applied to safety analysis calculations are the bias and the bias uncertainty . The bias is the deviation of the average k eff of the validation suite from unity. The bias uncertainty accounts for the statistical uncertainty in the bias based on the standard deviation, sample size, and distribution of k eff values of the validation suite. The values of bias and bias uncertainty ensure that the systems predicted to be subcritical by the computational method will indeed be subcritical. The bias and bias uncertainty are often combined to determine an upper subcritical limit (USL) or computational margin that can then be applied to safety analysis calculations. Many methods have been developed by different organizations to calculate the bias and bias uncertainty for various types of criticality analyses. Each of these methods typically requires that the validity of various underpinning statistical assumptions be confirmed to demonstrate that the method is appropriate for the analysis of a given validation suite. An example of the validation decision making flow is shown in Fig.1. As shown in Fig. 1, the analyst performing the validation fits a trend line to the data and performs a test to determine if the trend was a statistically better representation of the data than if it were treated as an uncorrelated sample. If the trend line is a better representation of the data, then the analyst uses any one of a number of trending techniques to determine the bias and bias uncertainty. If a trend is not an appropriate representation of the data, then the analyst proceeds to perform a normality assessment for the data. If the normal assumption can be shown to be acceptable, then the analyst calculates the bias and bias uncertainty with the parametric technique. If the assumption of normality cannot be justified, then the nonparametric technique is used. Once the decision flow has been followed and the appropriate technique has been selected, the bias and bias uncertainty is typically combined with an administrative margin to determine a USL below which calculated values of k eff for safety analysis models can be considered subcritical. The calculations used in each decision are often performed with spreadsheets or with small programs available at various sites performing criticality analyses. Expertise in understanding and interpreting the results must be maintained to perform these calculations. This can often be an error-prone process. Oak Ridge National Laboratory (ORNL) is currently developing the Validation and Data Evaluation Resource (VADER) to simplify and automate the criticality safety validation process and to provide a software quality assurance pedigree to the calculational methods used. This paper discusses the use of the Fulcrum user interface with VADER, the anticipated initial capabilities of VADER to perform validation analyses, and the output from the code.
FY2017 Pilot Project Plan for the Nuclear Energy Knowledge and Validation Center Initiative
To prepare for technical development of computational code validation under the Nuclear Energy Knowledge and Validation Center (NEKVAC) initiative, several meetings were held by a group of experts of the Idaho National Laboratory (INL) and the Oak Ridge National Laboratory (ORNL) to develop requirements of, and formulate a structure for, a transient fuel database through leveraging existing resources. It was concluded in discussions of these meetings that a pilot project is needed to address the most fundamental issues that can generate immediate stimulus to near-future validation developments as well as long-lasting benefits to NEKVAC operation. The present project is proposed based on the consensus of these discussions. Analysis of common scenarios in code validation indicates that the incapability of acquiring satisfactory validation data is often a showstopper that must first be tackled before any confident validation developments can be carried out. Validation data are usually found scattered in different places most likely with interrelationships among the data not well documented, incomplete with information for some parameters missing, nonexistent, or unrealistic to experimentally generate. Furthermore, with very different technical backgrounds, the modeler, the experimentalist, and the knowledgebase developer that must be involved in validation data development often cannot communicate effectively without a data package template that is representative of the data structure for the information domain of interest to the desired code validation. This pilot project is proposed to use the legendary TREAT Experiments Database to provide core elements for creating an ideal validation data package. Data gaps and missing data interrelationships will be identified from these core elements. All the identified missing elements will then be filled in with experimental data if available from other existing sources or with dummy data if nonexistent. The resulting hybrid validation data package (composed of experimental and dummy data) will provide a clear and complete instance delineating the structure of the desired validation data and enabling effective communication among the modeler, the experimentalist, and the knowledgebase developer. With a good common understanding of the desired data structure by the three parties of subject matter experts, further existing data hunting will be effectively conducted, new experimental data generation will be realistically pursued, knowledgebase schema will be practically designed; and code validation will be confidently planned.
Estimating uncertainty of inference for validation
We present a validation process based upon the concept that validation is an inference-making activity. This has always been true, but the association has not been as important before as it is now. Previously, theory had been confirmed by more data, and predictions were possible based on data. The process today is to infer from theory to code and from code to prediction, making the role of prediction somewhat automatic, and a machine function. Validation is defined as determining the degree to which a model and code is an accurate representation of experimental test data. Imbedded in validation is the intention to use the computer code to predict. To predict is to accept the conclusion that an observable final state will manifest; therefore, prediction is an inference whose goodness relies on the validity of the code. Quantifying the uncertainty of a prediction amounts to quantifying the uncertainty of validation, and this involves the characterization of uncertainties inherent in theory/models/codes and the corresponding data. An introduction to inference making and its associated uncertainty is provided as a foundation for the validation problem. A mathematical construction for estimating the uncertainty in the validation inference is then presented, including a possibility distribution constructed to represent the inference uncertainty for validation under uncertainty. The estimation of inference uncertainty for validation is illustrated using data and calculations from Inertial Confinement Fusion (ICF). The ICF measurements of neutron yield and ion temperature were obtained for direct-drive inertial fusion capsules at the Omega laser facility. The glass capsules, containing the fusion gas, were systematically selected with the intent of establishing a reproducible baseline of high-yield 10{sup 13}-10{sup 14} neutron output. The deuterium-tritium ratio in these experiments was varied to study its influence upon yield. This paper on validation inference is the first in a series of inference uncertainty estimations. While the methods demonstrated are primarily statistical, these do not preclude the use of nonprobabilistic methods for uncertainty characterization. The methods presented permit accurate determinations for validation and eventual prediction. It is a goal that these methods establish a standard against which best practice may evolve for determining degree of validation.
Soil Moisture Active Passive Mission L4_SM Data Product Assessment (Version 2 Validated Release)
During the post-launch SMAP calibration and validation (Cal/Val) phase there are two objectives for each science data product team: 1) calibrate, verify, and improve the performance of the science algorithm, and 2) validate the accuracy of the science data product as specified in the science requirements and according to the Cal/Val schedule. This report provides an assessment of the SMAP Level 4 Surface and Root Zone Soil Moisture Passive (L4_SM) product specifically for the product's public Version 2 validated release scheduled for 29 April 2016. The assessment of the Version 2 L4_SM data product includes comparisons of SMAP L4_SM soil moisture estimates with in situ soil moisture observations from core validation sites and sparse networks. The assessment further includes a global evaluation of the internal diagnostics from the ensemble-based data assimilation system that is used to generate the L4_SM product. This evaluation focuses on the statistics of the observation-minus-forecast (O-F) residuals and the analysis increments. Together, the core validation site comparisons and the statistics of the assimilation diagnostics are considered primary validation methodologies for the L4_SM product. Comparisons against in situ measurements from regional-scale sparse networks are considered a secondary validation methodology because such in situ measurements are subject to up-scaling errors from the point-scale to the grid cell scale of the data product. Based on the limited set of core validation sites, the wide geographic range of the sparse network sites, and the global assessment of the assimilation diagnostics, the assessment presented here meets the criteria established by the Committee on Earth Observing Satellites for Stage 2 validation and supports the validated release of the data. An analysis of the time average surface and root zone soil moisture shows that the global pattern of arid and humid regions are captured by the L4_SM estimates. Results from the core validation site comparisons indicate that "Version 2" of the L4_SM data product meets the self-imposed L4_SM accuracy requirement, which is formulated in terms of the ubRMSE: the RMSE (Root Mean Square Error) after removal of the long-term mean difference. The overall ubRMSE of the 3-hourly L4_SM surface soil moisture at the 9 km scale is 0.035 cubic meters per cubic meter requirement. The corresponding ubRMSE for L4_SM root zone soil moisture is 0.024 cubic meters per cubic meter requirement. Both of these metrics are comfortably below the 0.04 cubic meters per cubic meter requirement. The L4_SM estimates are an improvement over estimates from a model-only SMAP Nature Run version 4 (NRv4), which demonstrates the beneficial impact of the SMAP brightness temperature data. L4_SM surface soil moisture estimates are consistently more skillful than NRv4 estimates, although not by a statistically significant margin. The lack of statistical significance is not surprising given the limited data record available to date. Root zone soil moisture estimates from L4_SM and NRv4 have similar skill. Results from comparisons of the L4_SM product to in situ measurements from nearly 400 sparse network sites corroborate the core validation site results. The instantaneous soil moisture and soil temperature analysis increments are within a reasonable range and result in spatially smooth soil moisture analyses. The O-F residuals exhibit only small biases on the order of 1-3 degrees Kelvin between the (re-scaled) SMAP brightness temperature observations and the L4_SM model forecast, which indicates that the assimilation system is largely unbiased. The spatially averaged time series standard deviation of the O-F residuals is 5.9 degrees Kelvin, which reduces to 4.0 degrees Kelvin for the observation-minus-analysis (O-A) residuals, reflecting the impact of the SMAP observations on the L4_SM system. Averaged globally, the time series standard deviation of the normalized O-F residuals is close to unity, which would suggest that the magnitude of the modeled errors approximately reflects that of the actual errors. The assessment report also notes several limitations of the "Version 2" L4_SM data product and science algorithm calibration that will be addressed in future releases. Regionally, the time series standard deviation of the normalized O-F residuals deviates considerably from unity, which indicates that the L4_SM assimilation algorithm either over- or under-estimates the actual errors that are present in the system. Planned improvements include revised land model parameters, revised error parameters for the land model and the assimilated SMAP observations, and revised surface meteorological forcing data for the operational period and underlying climatological data. Moreover, a refined analysis of the impact of SMAP observations will be facilitated by the construction of additional variants of the model-only reference data. Nevertheless, the “Version 2” validated release of the L4_SM product is sufficiently mature and of adequate quality for distribution to and use by the larger science and application communities.
Impact of recent ENDF nuclear data update, high initial enrichment and high burnup fuel on critical experiments applicability determination via the integral index c k for burnup credit validation
In 2012, NUREG/CR-7109 reported on the validation of burnup credit calculations involving major and minor actinides and major fission products which was investigated for pressurized and boiling water reactor (PWR and BWR) fuel enrichments up to 5 wt% 235 U and assembly-average burnups up to 60 GWd/MTU. Recently, there has been interest in increasing the maximum enrichment used in PWR fuel as high as 8 wt% 235 U and correspondingly increasing the maximum assembly-average burnups to approximately 75 GWd/MTU. These proposed increases in enrichment and burnup necessitate reinvestigation of the validation basis for k eff calculations for this expanded application space. Additionally, the 2012 study was performed by using the Evaluated Nuclear Data File (ENDF)/B-VII.0 nuclear data with the SCALE 6 covariance library, and the effects of using the newly released ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data and covariance libraries should be evaluated. In this work, published in NUREG/CR-7309 in 2025, the validation assessment was performed consistently with NUREG/CR-7109: modeling irradiated fuel assemblies in the Generic Burnup Credit (GBC)-32 cask defined in NUREG/CR-6747. The TSUNAMI-3D sequence was used to generate sensitivity data for the application model, and the data were compared with sensitivity data from select benchmark models. The integral parameter c k is the metric of similarity used in this study and is consistent with NUREG/CR-7109, where a c k value in excess of 0.8 indicates sufficient similarity for use in validation. A new set of benchmark experiments with sensitivity data has been assembled for this effort. The number of experiments with available sensitivity data is now 2,104, compared to 474 in NUREG/CR-7109. This increase was facilitated by the efforts of the Nuclear Energy Agency to generate sensitivity data for a majority of the experiments in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook to supplement the data available in the Oak Ridge National Laboratory (ORNL) Verified, Archived Library of Inputs and Data (VALID). The complete set of benchmarks considered here includes experiments for low-enriched uranium (LEU), intermediate enriched uranium (IEU), and a mixture of uranium and plutonium (MIX) from the ICSBEP Handbook and VALID, as well as ORNL models of the Haut Taux de Combustion (HTC) experiments and other potentially relevant models not included in VALID. The updated similarity study shows that none of the extended burnup and higher enrichment combinations considered show a significant decrease in the number of potentially applicable experiments, meaning sufficient critical experiments exist for the validation of BUC criticality safety calculations, with initial enrichments up to 8 wt% 235 U and burnups up to 80 GWd/MTU. Additionally, both the ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data libraries can be used for validation since the number of critical experiments applicable for validation increases for most cases with the most recent nuclear data compared to the previous one. As in previous BUC validation studies, the French HTC experiments are the most similar in a majority of the application cases studied, especially from representative discharge burnups ranging from 40 to 80 GWd/MTU. In conclusion, these results match the conclusions presented in NUREG/CR-7109 regarding validation of the primary actinides in BUC analyses.
Nuclear Energy Knowledge and Validation Center (NEKVaC) Needs Workshop Summary Report
The Department of Energy (DOE) has made significant progress developing simulation tools to predict the behavior of nuclear systems with greater accuracy and of increasing our capability to predict the behavior of these systems outside of the standard range of applications. These analytical tools require a more complex array of validation tests to accurately simulate the physics and multiple length and time scales. Results from modern simulations will allow experiment designers to narrow the range of conditions needed to bound system behavior and to optimize the deployment of instrumentation to limit the breadth and cost of the campaign. Modern validation, verification and uncertainty quantification (VVUQ) techniques enable analysts to extract information from experiments in a systematic manner and provide the users with a quantified uncertainty estimate. Unfortunately, the capability to perform experiments that would enable taking full advantage of the formalisms of these modern codes has progressed relatively little (with some notable exceptions in fuels and thermal-hydraulics); the majority of the experimental data available today is the "historic" data accumulated over the last decades of nuclear systems R&D. A validated code-model is a tool for users. An unvalidated code-model is useful for code developers to gain understanding, publish research results, attract funding, etc. As nuclear analysis codes have become more sophisticated, so have the measurement and validation methods and the challenges that confront them. A successful yet cost-effective validation effort requires expertise possessed only by a few, resources possessed only by the well-capitalized (or a willing collective), and a clear, well-defined objective (validating a code that is developed to satisfy the need(s) of an actual user). To that end, the Idaho National Laboratory established the Nuclear Energy Knowledge and Validation Center to address the challenges of modern code validation and to manage the knowledge from past, current, and future experimental campaigns. By pulling together the best minds involved in code development, experiment design, and validation to establish and disseminate best practices and new techniques, the Nuclear Energy Knowledge and Validation Center (NEKVaC or the ‘Center’) will be a resource for industry, DOE Programs, and academia validation efforts.
Development of Criticality Safety Validation Guidance for NRC-Regulated Activities
Some guidance documents support validation of criticality safety evaluations for many system types, and some accommodate different regulators or regulatory requirements. While these reports address specific applications, no single document applies to all systems and incorporates both traditional and sensitivity/uncertainty-based validation techniques. Oak Ridge National Laboratory will develop a single reference report for the US Nuclear Regulatory Commission (NRC) that provides modern examples and suggested recommendations for a uniform approach for performing and documenting k eff calculation validations applicable to any system containing fissile material. The project will include a literature review and development of a new, comprehensive NUREG/CR document on nuclear criticality safety validation. The NUREG will address the following experiences from recent reviews: 1. Inappropriate critical experiment selection 2. Insufficient trending analysis 3. Incorrectly calculated 95/95 uncertainties 4. Failure to address how validation applies to safety analysis 5. Lack of goodness-of-fit testing in trending analyses 6. Incorrect use of commercial reactor critical data 7. Failure to meet bias determination methodology prerequisites 8. Inappropriate extrapolation of bias and uncertainty 9. Failure to identify validation analysis gaps and weaknesses 10. Inadequate validation analysis documentation the final report will provide guidance on use of trending analysis results, acceptable confidence levels for normality testing and trending analysis, management of validation analysis gaps and weaknesses, use of sensitivity and uncertainty analysis in validation analysis, and potential impact of correlations among critical experiments used in validation. It will also consolidate existing guidance documents using both traditional and sensitivity/uncertainty-based approaches. This document will support NRC-regulated activities, as well as validation used in criticality safety within other regulatory frameworks.
Development of criticality safety validation guidance for NRC-regulated activities
Some guidance documents support validation of criticality safety evaluations for many system types, and some accommodate different regulators or regulatory requirements. While these reports address specific applications, no single document applies to all systems and incorporates both traditional and sensitivity/uncertainty-based validation techniques. Oak Ridge National Laboratory will develop a single reference report for the US Nuclear Regulatory Commission (NRC) that provides modern examples and suggested recommendations for a uniform approach for performing and documenting k{sub eff} calculation validations applicable to any system containing fissile material. The project will include a literature review and development of a new, comprehensive NUREG/CR document on nuclear criticality safety validation. The NUREG will address the following experiences from recent reviews: 1) Inappropriate critical experiment selection; 2) Insufficient trending analysis; 3) Incorrectly calculated 95/95 uncertainties; 4) Failure to address how validation applies to safety analysis; 5) Lack of goodness-of-fit testing in trending analyses; 6) Incorrect use of commercial reactor critical data; 7) Failure to meet bias determination methodology prerequisites; 8) Inappropriate extrapolation of bias and uncertainty; 9) Failure to identify validation analysis gaps and weaknesses; and 10) Inadequate validation analysis documentation. The final report will provide guidance on use of trending analysis results, acceptable confidence levels for normality testing and trending analysis, management of validation analysis gaps and weaknesses, use of sensitivity and uncertainty analysis in validation analysis, and potential impact of correlations among critical experiments used in validation. It will also consolidate existing guidance documents using both traditional and sensitivity/uncertainty-based approaches. This document will support NRC-regulated activities, as well as validation used in criticality safety within other regulatory frameworks. (authors)
OECD/NEA EGMPEBV Activities in Multi-Physics Verification and Validation
The Expert Group on Multi-Physics Experimental Data, Benchmarks and Validation (EGMPEBV) was established in 2014 by the Nuclear Energy Agency (NEA) at the Organization for Economic Co-operation and Development (OECD) to establish processes for certification of experimental data and development of benchmark models for validation of Multi-Physics (MP) Modeling and Simulation (M and S) computational systems. The aim of the group is to provide member countries with guidelines and recommendations for validating and improving their novel multi-physics simulations, and with an access to key experimental data. To be used to their full potential, these novel tools will require a more complex suite of validation experiments due to the multiple energy, spatial and temporal scales, as well as the number of physical phenomena being simulated. They will also require accurate measurements of all terms, including coupling terms representing the feedback effects, in situations where the appropriate experimental techniques and facilities might not exist today. However, the ability to conduct validation experiments has for certain applications progressed at a slower pace than for computational methods, or in some cases it has significantly regressed (through shutdown of facilities, or through retirement of experts). In addition, as modelling capabilities are reaching deeper levels in single physics phenomena and in coupled behaviors, appropriate experimental techniques may not yet exist. Validation of multiple physics models requires a wide variety of experimental data, which emphasizes the importance of maximizing the use of historically accumulated data to avoid the significant cost of performing similar experiments today. Moreover, the pedigree and quality of this data as it pertains to modern day simulation methods may be insufficient for rigorous validation of high fidelity modeling and simulation tools. Thus, these data can often exhibit limitations including a lack of measurement accuracy or a lack of knowledge of the measurement uncertainty in the experimental techniques; an absence of measurements for some critical parameters; an obscuring of relationships between individual physics phenomena owing to the output data resolution; or simply an inability to allow for a detailed reinterpretation of the experiments based on the documented information. The organization of the EGMPEBV relies on three Task Forces, focused on 1) Experimental Data Qualification and Benchmark Evaluation; 2) Methods and Standards, and 3) Specific Applications. Task Force 1 is focused on providing better and more accurate experimental datasets, which support validation of high-fidelity multi-physics modelling and simulation (M and S) tools. At the same time it has to consider the incompleteness of past experimental data sets (in terms of data, documentation, or uncertainties) and with the limited number of available multi-physics experimental facilities. Task Force 2 is designed to develop validation methods and guidelines, and uncertainty qualification for the new family of multi-physics, multi-scale codes in the context of emerging demands such as longer fuel cycles and power uprate. Task Force 3 is focused on applications of validation experiments and has the objective to organize multi-physics M and S benchmarks involving validation experiments.
Blind Modeling Validation Exercises Using the Horizontal Dry Cask Simulator
The U.S. Department of Energy (DOE) established a need to understand the thermal-hydraulic properties of dry storage systems for commercial spent nuclear fuel (SNF) in response to a shift towards the storage of high-burnup (HBU) fuel (> 45 gigawatt days per metric ton of uranium, or GWd/MTU). This shift raises concerns regarding cladding integrity, which faces increased risk at the higher temperatures within spent fuel assemblies present within HBU fuel compared to low-burnup fuel (≤ 45 GWd/MTU). A dry cask simulator (DCS) was built at Sandia National Laboratories (SNL) in Albuquerque, New Mexico to produce validation-quality data that can be used to test the accuracy of the modeling used to predict cladding temperatures. These temperatures are critical to evaluating cladding integrity throughout the storage cycle of commercial spent nuclear fuel. A model validation exercise was previously carried out for the DCS in a vertical configuration. Lessons learned during the previous validation exercise have been applied to a new, blind study using a horizontal dry cask simulator (HDCS). Three modeling institutions – the Nuclear Regulatory Commission (NRC), Pacific Northwest National Laboratory (PNNL), and Empresa Nacional del Uranio, S.A., S.M.E. (ENUSA) – were granted access to the input parameters from the DCS Handbook, SAND2017-13058R, and results from a limited data set from the horizontal BWR dry cask simulator tests reported in the HDCS update report, SAND2019-11688R. With this information, each institution was tasked to calculate peak cladding temperatures and air mass flow rates for ten HDCS test cases. Axial as well as vertical and horizontal transverse temperature profiles were also calculated. These calculations were done using modeling codes (ANSYS/Fluent, STAR-CCM+, or COBRA-SFS), each with their own unique combination of modeling assumptions and boundary conditions. For this validation study, the ten test cases of the horizontal dry cask simulator were defined by three independent variables – fuel assembly decay heat (0.5 kW, 1 kW, 2.5 W, and 5 kW), internal backfill pressure (100 kPa and 800 kPa), and backfill gas (helium and air). The plots provided in Chapter 3 of this report show the axial, vertical, and horizontal temperature profiles obtained from the dry cask simulator experiments in the horizontal configuration and the corresponding models used to describe the thermal-hydraulic behavior of this system. The tables provided in Chapter 3 illustrate the closeness of fit of the model data to the experiment data through root mean square (RMS) calculations of the error in peak cladding temperatures (PCTs), PCT axial locations, axial temperature profiles, vertical and horizontal temperature profiles at two different axial locations, and air mass flow rates for the ten test cases, normalized by the experimental results. The model results are assigned arbitrary model numbers to retain anonymity. Due to the relatively flat axial temperature profiles, small temperature gradients resulted in large deviations of all models’ PCT axial location from the experimental PCT axial location. When the PCT axial location error is excluded in the calculation of the combined RMS of the normalized errors that considers PCT, the temperature profiles, and the air mass flow rates, the model data fits the experimental data to within 5%. When the vault information is excluded, the model data fits the experimental data to within 2.5%. An error analysis was developed further for one model, using the model and experimental uncertainties in each validation parameter to calculate validation uncertainties. The uncertainties for each parameter were used to define quantifiable validation criteria. For this analysis, the model was considered validated for a given comparison metric if the normalized error in that metric divided by the validation uncertainty was less than or equal to 1. When considering the combined RMS of the normalized errors of all metrics divided by their validation uncertainties, the model was found to have satisfied the criterion for model validation.
Validation on the Europa Clipper Mission in the Formulation Phase
The Europa Clipper mission will perform a detailed investigation of Europa’s environment and habitability by placing a spacecraft into a looping orbit around Jupiter and performing repeated close Europa flybys. The Europa Clipper Project Verification and Validation (V&V) team is responsible for verifying that the Project System is compliant with the science and engineering requirements levied on it and validating that it is capable of meeting the mission objectives. Europa Clipper has developed a V&V framework to ensure that mission capabilities are realized at a reasonable confidence level prior to launch. The V&V team will coordinate the validation activities defined by this framework throughout the project lifecycle as the spacecraft evolves from design to implementation and operations. Validation of space missions is typically grouped into three categories: 1) requirements validation, 2) model validation, and 3) system validation. System validation, along with verification activities, are often the primary focus of V&V programs and these efforts peak in the implementation phase. However, the increasing reliance of exploration missions on models and simulations, and the complexity of the Europa Clipper mission, have dictated attention to requirements and model validation in the formulation phase. This paper discusses the development of the Europa Clipper V&V framework with emphasis on the validation of models and simulations, and of requirements. Approaches include the adaptation of institutional guidelines, such as those in the NASA-STD-7009 document, to create a Project Model V&V Plan and the use of tools such as DOORS NG to plan model validation and derive requirement quality metrics.
The SCALE Verified, Archived Library of Inputs and Data - VALID
The Verified, Archived Library of Inputs and Data (VALID) at ORNL contains high quality, independently reviewed models and results that improve confidence in analysis. VALID is developed and maintained according to a procedure of the SCALE quality assurance (QA) plan. This paper reviews the origins of the procedure and its intended purpose, the philosophy of the procedure, some highlights of its implementation, and the future of the procedure and associated VALID library. The original focus of the procedure was the generation of high-quality models that could be archived at ORNL and applied to many studies. The review process associated with model generation minimized the chances of errors in these archived models. Subsequently, the scope of the library and procedure was expanded to provide high quality, reviewed sensitivity data files for deployment through the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). Sensitivity data files for approximately 400 such models are currently available. The VALID procedure and library continue fulfilling these multiple roles. The VALID procedure is based on the quality assurance principles of ISO 9001 and nuclear safety analysis. Some of these key concepts include independent generation and review of information, generation and review by qualified individuals, use of appropriate references for design data and documentation, and retrievability of the models, results, and documentation associated with entries in the library. Some highlights of the detailed procedure are discussed to provide background on its implementation and to indicate limitations of data extracted from VALID for use by the broader community. Specifically, external users of data generated within VALID must take responsibility for ensuring that the files are used within the QA framework of their organization and that use is appropriate. The future plans for the VALID library include expansion to include additional experiments from the IHECSBE, to include experiments from areas beyond criticality safety, such as reactor physics and shielding, and to include application models. In the future, external SCALE users may also obtain qualification under the VALID procedure and be involved in expanding the library. The VALID library provides a pathway for the criticality safety community to leverage modeling and analysis expertise at ORNL.