Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Underground Test Area Activity Waste Management Plan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,515 records · Page 12

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD

Modeling Ni-Cd performance. Planned alterations to the Goddard battery model

The Goddard Space Flight Center (GSFC) currently has a preliminary computer model to simulate a Nickel Cadmium (Ni-Cd) performance. The basic methodology of the model was described in the paper entitled Fundamental Algorithms of the Goddard Battery Model. At present, the model is undergoing alterations to increase its efficiency, accuracy, and generality. A review of the present battery model is given, and the planned charges of the model are described.

Jagielski, J. M.

X-Hab 2026: LiDAR-Powered Autonomous Charging Service Capability for Surface Rovers and Systems

This document details the timeline of the LiDAR-Powered Autonomous Charging Service Capability for Surface Rovers and Systems project, initiated by the Fall 2025 semester class and completed by the Spring 2026 semester class. This project focuses on developing a fully autonomous system composed of a mobile surface rover and an induction charging station with a robotic arm, both controlled by their own NVIDIA Jetson Orin Nano. Structural improvements to the rover suspension system and body eliminated excessive camber, reduced stress and strain on the plexiglass body, and improved maneuverability and durability of the rover. The charging station robotic arm was fully redesigned to increase reach while minimizing weight and increasing misalignment tolerance during docking on uneven terrain. Electrical system improvements addressed previous torque and power limitations of both the rover and charging station arm. High-torque servo motors were selected based on updated calculations which incorporated terrain slope and Factor of Safety, enabling zero-point turning for the rover and increased payload capacity of the charging station arm. Significant progress was made in autonomy and perception. The rover now employs 3D LiDAR and SLAM mapping for localization, mapping, and path planning. The Battery Monitoring System (BMS) was created to coordinate battery management between the rover and charging station. The BMS provides continuous monitoring of battery state of charge, temperature, current, and will enable the autonomous initiation, execution, and termination of the charging cycle via Bluetooth communication. Testing of the WIBOTIC induction charging system demonstrated reliable power transfer under both aligned and misaligned conditions. This project demonstrated the ability of an autonomously navigating surface rover to independently plan a path to the charging station, dock, and the charging station to autonomously deploy a robotic charging arm and initiate charging of the rover. This work details the progress made to demonstrate the feasibility of autonomous surface rover navigation and recharging systems.

Megan Steele

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Spacesuit

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Human Thermal Modeling

Coordinated Natural Gas and Electric Planning: Case Studies of Current Approaches and Practices

This paper examines how natural gas and electric utilities across eight U.S. states and two Canadian provinces are beginning to coordinate historically separate planning processes in response to growing system interdependencies, policy mandates, aging infrastructure, and changing customer energy choices. Electricity planning has long relied on robust integrated resource planning frameworks that weigh numerous objectives, risks, and costs. Natural gas planning, on the other hand, is typically less transparent and more narrowly focused on safety and system integrity. As economic, reliability, and policy drivers place new and shared demands on both systems, jurisdictions and utilities are experimenting with approaches such as coordinated forecasting, non pipeline alternatives, and combined planning pilots. A few have issued regulatory or statutory directives for greater data sharing and methodological alignment. Case studies from British Columbia, California, Colorado, Illinois, Massachusetts, Minnesota, New York, Québec, Rhode Island, and Washington illustrate a wide range of approaches to rethinking siloed planning. The paper identifies several common themes across the jurisdictions examined. It provides observations on the methods, processes, and organizational steps that may be needed in the future to address the challenges being faced by states and utilities. Lastly, it identifies some initial steps that states and utilities can consider if they would like to pursue more integrated, cost-effective, policy-aligned energy system planning.

03 NATURAL GAS

Thermal Analysis of the Advanced Modular Power Systems (AMPS) Power Electronic Modules

In an effort to transform future space power system architectures and operations, the Advanced Modular Power Systems (AMPS) project is currently developing an interface standard for power electronic modules to enable modular architectures for space power systems. Each architecture would consist of one or more modular electronic units (MEU) that would comprise of a tailored combination of modules. The standard currently comprises modules enabling switchgear, power conversion, and data interfacing. The objective of the AMPS project is to enable the modularity and interchangeability of different architectures using these standardized modules in hopes of reducing complexity and cost, increasing inherent redundancy and reliability, and minimizing power system redesign for future programs. A key enabler to these future modular architectures will be the thermal management system, which has to contend with acquiring heat from the electronics modules at the card level and then transporting that heat to the radiator of the larger system. The focus of this paper, therefore, will be the thermal design and analysis of multiple AMPS power electronics modules and the development of their thermal-vacuum test.

Modular Power Electronics

Flexible and Extensive Platinum Ion Gel Condensers for Programmable Catalysis

Catalytic condensers composed of ion gels separating a metal electrode from a platinum-on-carbon active layer were fabricated and characterized to achieve more powerful, high surface area dynamic heterogeneous catalyst surfaces. Ion gels comprised of poly(vinylidene difluoride)/1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide were spin coated as a 3.8 μm film on a Au surface, after which carbon sputtering of a 1.8 nm carbon film and electron-beam evaporation of 2 nm Pt clusters created an active surface exposed to reactant gases. Electronic characterization indicated that most charge condensed within the Pt nanoclusters upon application of a potential bias, with the condenser device achieving a capacitance of ∼20 μF/cm 2 at applied frequencies of up to 120 Hz. The maximum charge of ∼10 14 |e – | cm –2 was condensed under stable device conditions at 200 °C on catalytic films with ∼10 15 sites cm –2 . Grazing incidence infrared spectroscopy measured carbon monoxide adsorption isobars, indicating a change in the CO* binding energy of ∼19 kJ mol –1 over an applied potential bias of only 1.25 V. Condensers were also fabricated on flexible, large area Kapton substrates allowing stacked or tubular form factors that facilitate high volumetric active site densities, ultimately enabling a fast and powerful catalytic condenser that can be fabricated for programmable catalysis applications.

Catalysis

Planning for Execution Monitoring on A Planetary Rover

A planetary rover will be traversing largely unknown and often unknowable terrain. In addition to geometric obstacles such as cliffs, rocks, and holes, it may also have to deal with non-geometric hazards such as soft soil and surface breakthroughs which often cannot be detected until rover is in imminent danger. Therefore, the rover must monitor its progress throughout a traverse, making sure to stay on course and to detect and act on any previously unseen hazards. Its onboard planning system must decide what sensors to monitor, what landmarks to take position readings from, and what actions to take if something should go wrong. The planning systems being developed for the Pathfinder Planetary Rover to perform these execution monitoring tasks are discussed. This system includes a network of planners to perform path planning, expectation generation, path analysis, sensor and reaction selection, and resource allocation.

Erann Gat

Manned Mars Systems Study

A study is underway to determine attractive system options, perform trade studies, and provide comparative data for astronaut missions to Mars. Because of an emphasis in this work on deriving requirements and candidates for the transportation and facility infrastructure for such missions, all relevant technologies and mission constraints are also being considered. These include on-orbit assembly, trajectory type, launch opportunities, propellant storage, crew size, cabin pressure, artificial gravity, life-support systems, radiation hazards, power/energy storage, thermal control, human factors, communications, abort scenarios, landing techniques, exploration strategies and science activities. It is planned to scope several example missions and to identify enabling and significantly enhancing technologies for accomplishing the goals of the human exploration of Mars.

Benton C Clark

Reaction Optimization for Enzymatic Deconstruction of Industrially Relevant Nylon Composites

Plastics such as polyamides (PAs) possess unique physicochemical properties that make them indispensable in modern society. However, their energy‐intensive production and challenging end‐of‐life management highlight the urgent need for efficient recycling or remanufacturing solutions. Enzymatic depolymerization offers a promising route toward circular recycling, yet remains constrained by limited enzyme characterization, lack of validation under industrially relevant conditions and substrates, and overall performance. Here, we optimized the reaction conditions for three recently discovered nylon‐degrading enzymes. One of them, Nyl12, achieved product titers with PA6 and PA66 that exceed previously reported values, without enzyme engineering or substrate pretreatment. We further demonstrated the scalability of the process and its application to complex PA‐based materials used in microelectronic components. Analysis of substrate features, including surface area and particle size, revealed key parameters governing enzymatic activity and provided a framework for future pretreatment and process optimization efforts. In combination, these efforts provide a new benchmark for enzymatic nylon recycling.

nylon

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)

Simulating the Lunar Thermal Environment for the Surface-Deployed LEMS Artemis III TVAC Test

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. Presented is the system thermal vacuum test plan and configuration to validate the thermal control system performance in a flight-like environment. The test will measure the nighttime heat leaks for the bus and 18 seismometers to ensure lunar night survival and operability.

Thermal

Simulating the Lunar Thermal Environment for the Surface-Deployed LEMS Artemis III TVAC Test

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. Presented is the system thermal vacuum test plan and configuration to validate the thermal control system performance in a flight-like environment. The test will measure the nighttime heat leaks for the bus and 18 seismometers to ensure lunar night survival and operability.

Thermal

Simulating the Lunar Thermal Environment for the Surface-Deployed LEMS Artemis III TVAC Test

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. Presented is the system thermal vacuum test plan and configuration to validate the thermal control system performance in a flight-like environment. The test will measure the nighttime heat leaks for the bus and 18 seismometers to ensure lunar night survival and operability.

TVAC

Self-Leveling Inks for Printing Ultra-uniform Perovskite Solar Modules by Flexography

The report describes the development of scalable manufacturing methods for high-performance, stable perovskite solar modules using flexographic printing. The project developed self-leveling perovskite inks that exploit Marangoni flows to reduce coating defects and improve large-area film uniformity. Bayesian optimization was integrated with high-throughput photoluminescence mapping and photovoltaic measurements to efficiently optimize ink formulations and printing conditions. The resulting printed perovskite solar cells achieved champion power conversion efficiencies above 21.6%, with median efficiencies exceeding 20% across large device batches. At the module scale, printed devices achieved active-area efficiencies up to approximately 17.3% on 25 cm² substrates. The project also demonstrated improved performance and stability using additively patterned interconnections compared with laser-scribed controls. Overall, the work establishes a data-driven, roll-compatible pathway toward high-throughput, low-capital-cost manufacturing of uniform and stable perovskite photovoltaics.

14 SOLAR ENERGY

Effectively Considering the Distribution System in Integrated Resource Plans

While electricity planning practices vary by state and utility based on utility type and market structure, integrated resource planning (IRP) remains a prominent vehicle — even in states with centrally-organized wholesale electricity markets. IRP focuses on meeting forecasted long-term electricity needs. Typically, utilities have not considered impacts of design and operation of the low-voltage distribution network in IRP. With advanced capabilities of grid-edge technologies to generate and store electricity and provide load flexibility, and large utility investments in distribution systems, it's increasingly important to consider at least some distribution planning elements in IRP. This report considers the value proposition for doing so, such as reducing utility costs through resource co-optimization and strategic siting of grid-edge resources, and idenfities the most important touchpoints between planning for bulk power and distribution systems and provide a range of tactics for integrating these two processes.

Relf, Grace [Lawrence Berkeley National Laboratory

Thermal Data-driven Model Reduction for Enhanced Battery Health Monitoring

Electric aviation faces a major challenge of avoiding potentially catastrophic consequences of the battery’s thermal runaway while keeping the weight of the battery low. Detection of early warning signals of battery failures requires accurate monitoring of the battery’s health throughout its lifespan. However, identifying the parameters of the battery from field data is notoriously difficult. We investigate this problem within the framework of modeling the temperature dynamics of a Li-ion cell during tests simulating loading in electric aircraft flights. It is found that the parameters of a higher-fidelity physics-based thermal model cannot be identified from the simulated flight data. To resolve this issue, we reduce the higher-fidelity thermal model to a model with fewer parameters. The resulting reduced-order model can predict temperature dynamics accurately and is identifiable throughout the cell’s lifespan which allows using the model’s parameters to monitor the state-of-health of the aging cell and detect anomalies in thermal behavior.

Li ion batteries