Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time Reversal Technique”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Linearization of an Electron Beam’s Longitudinal Phase Space Using a Hollow-Channel Plasma

The removal of undesired beam nonlinear energy chirp (time-energy correlation) or linearization of the beam longitudinal phase space (LPS) is crucial for high-brightness linac-based scientific applications, such as x-ray free-electron lasers. In this paper, we propose that a low-density hollow channel plasma can be used as a near-ideal passive linearizer to significantly linearize the beam LPS and, at the same time, preserve the beam emittance. Physically, the passage of the beam through the hollow plasma channel excites a strong quasicosinoidal longitudinal wakefield that acts to mitigate the beam nonlinear energy chirp by superimposing a reverse chirp on the beam. The theoretical analyses and large-scale three-dimensional start-to-end simulations confirm that the beam longitudinal phase space can be almost completely linearized without noticeable beam emittance growth. In conclusion, application of such a near-ideal linearizer may significantly improve the performance of numerous accelerator-based applications.

43 PARTICLE ACCELERATORS↗

Cooperative control of a DNA origami force sensor

Abstract Biomolecular systems are dependent on a complex interplay of forces. Modern force spectroscopy techniques provide means of interrogating these forces, but they are not optimized for studies in constrained environments as they require attachment to micron-scale probes such as beads or cantilevers. Nanomechanical devices are a promising alternative, but this requires versatile designs that can be tuned to respond to a wide range of forces. We investigate the properties of a nanoscale force sensitive DNA origami device which is highly customizable in geometry, functionalization, and mechanical properties. The device, referred to as the NanoDyn, has a binary (open or closed) response to an applied force by undergoing a reversible structural transition. The transition force is tuned with minor alterations of 1 to 3 DNA oligonucleotides and spans tens of picoNewtons (pN). The DNA oligonucleotide design parameters also strongly influence the efficiency of resetting the initial state, with higher stability devices (≳10 pN) resetting more reliably during repeated force-loading cycles. Finally, we show the opening force is tunable in real time by adding a single DNA oligonucleotide. These results establish the potential of the NanoDyn as a versatile force sensor and provide fundamental insights into how design parameters modulate mechanical and dynamic properties.

59 BASIC BIOLOGICAL SCIENCES↗

Surface processing and discharge-conditioning of high voltage electrodes for the Ra EDM experiment

The Ra EDM experiment uses a pair of high voltage electrodes to search for the atomic electric dipole moment of 225 Ra. We use identical, plane–parallel electrodes with a primary high gradient surface of 200 mm 2 to generate reversible DC electric fields. Our statistical sensitivity is linearly proportional to the electric field strength in the electrode gap. We adapted surface decontamination and processing techniques from accelerator physics literature to chemical polish and clean a suite of newly fabricated large-grain niobium and grade-2 titanium electrodes. Three pairs of niobium electrodes and one pair of titanium electrodes were discharge-conditioned with a custom high voltage test station at electric field strengths as high as +52.5 kV/mm and –51.5 kV/mm over electrode gap sizes ranging from 0.4 mm to 2.5 mm. One pair of large-grain niobium electrodes was discharge-conditioned and validated to operate at ±20 kV/mm with steady-state leakage current ≤ 25 pA (1σ) and a polarity-averaged 98 ± 19 discharges per hour. These electrodes were installed in the Ra EDM experimental apparatus, replacing a copper electrode pair, and were revalidated to ±20 kV/mm. Here, the niobium electrodes perform at an electric field strength 3.1 times larger than the legacy copper electrodes and are ultimately limited by the maximum output of our 30 kV bipolar power supply.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of a Cephalad Fluid Shift Countermeasure

INTRODUCTION: This project will provide critical data required to objectively determine how an optimized thigh cuff could be incorporated into the NASA integrated physiological countermeasure suite. This project will determine if thigh cuffs used during simulated spaceflight impact intracranial pressure (ICP), ocular structure and function, and intraocular pressure (IOP) using state of-the-art techniques. Additionally, some of the same methods, hardware, and protocols will be employed in the present investigation to enable direct comparisons to the International Space Station (ISS) "Fluid Shifts" experiment with Chibis-Lower Body Negative Pressure (LBNP). This study will determine the temporal physiological responses of thigh cuff application and removal on ocular and cerebral variables (including invasive ICP) in a microgravity analog. Furthermore, this proposed study will determine tissue pressure distribution applied by thigh cuffs in order to improve comfort, mobility, and efficacy of the countermeasure. Our specific aim is to determine the efficacy of a novel thigh cuff device to mitigate cephalad fluid shifts. We hypothesize that a thigh cuff countermeasure employed in a microgravity analog will temporarily reverse or attenuate ocular and cerebral-volume-pressure variables, approaching normal Earth-based seated posture, the most frequent posture assumed in daily life. In addition, we hypothesize that the magnitude of fluid and pressure redistribution using a thigh cuff countermeasure may require a longer exposure time than that of Chibis-LBNP (using ground-based data from our "Fluid Shifts" project). This project directly addresses Critical Path Roadmap Risks and Questions regarding "Risk of Spaceflight-Induced Intracranial Hypertension/Vision Alterations," and IRP Gap VIIP13: We need to identify preventative and treatment countermeasures to mitigate changes in ocular structure and function and intracranial pressure during spaceflight. METHODS: Noninvasive measures and tissue pressure distributions beneath thigh cuffs The objectives of this study are to: 1) determine the distribution of skin surface pressures beneath the advanced thigh cuff in ten subjects, 2) calibrate the built-in pressure measurement system of the advanced thigh cuff using an industry standard device, and 3) collect subjective feedback and data on the new cuff design to allow for further adjustments prior to invasive studies. A Tekscan Industrial Sensing (I-Scan) system will measure the pressure distribution of the advanced thigh cuff against the skin. In addition, we will measure blood pooling in the thigh and record the circumference of the thigh using Hokanson strain gauge plethysmography. The advanced thigh cuff will be adjusted to obtain a skin contact pressure of 30-50 mmHg as visualized on the Tekscan system. The built-in advanced thigh cuff pressure monitor will be recorded simultaneously to allow direct comparison to the Tekscan measurements. The volunteer will then remove the thigh cuff and remain at rest for five minutes with no legging applied. The thigh cuff will be donned again and pressure measurements will be taken in the same manner for up to 10 repetitions to show reproducibility of pressure after donning. At the conclusion of the study, subjects will be asked to flex their knee, stand, walk, and sit with the thigh cuff activated. During each of these maneuvers the subject will rate their pain/comfort using a modified Borg scale. Effect of thigh cuffs on ICP during simulated microgravity Ommaya reservoir patients will be recruited from the John Wayne Cancer Institute. Ommaya reservoirs provide safe and direct access for the measurement of ICP. Subjects will be instrumented for continuous blood pressure, ECG, and invasive ICP measures. The subjects will be positioned in the upright sitting posture for a 10-minute stabilization period. After the 10-minute stabilization period, imaging measures [ICP, Optical Coherence Tomography, IOP, ocular and vascular ultrasound] will be performed. Following baseline seated measures, the subject will be positioned randomly in the supine, 15deg head-down-tilt, and 15deg head-down-tilt with thigh cuffs and measures repeated. DISCUSSION: Tests to down-select thigh cuff designs will occur in early 2016. Invasive ICP and noninvasive eye imaging tests will begin in spring 2016. Supported by NSBRI through NCC 9-58.

Macias, B.↗

Comprehensive earthquake catalogue update and spatiotemporal distribution analysis for Iraq and surrounding regions, northeastern Arabian Plate

The updated earthquake catalogue for Iraq covers the period from 1900 to the end of 2021 and includes over 37 000 recorded earthquakes. To create this comprehensive catalogue, five key steps were taken: compiling bulletins, calculating moment magnitudes, harmonizing magnitudes, establishing empirical conversion relations and evaluating the completeness of the catalogue. A notable enhancement in this update is the direct calculation of moment magnitudes for approximately 2800 earthquakes, achieved through the coda envelope technique and waveform data from the Mesopotamian Seismological Network (MPSN) in Iraq. This updated catalogue serves as a valuable resource for examining the spatiotemporal distribution of earthquakes, with respect to earthquake density, maximum moment magnitude and seismogenic depths. Additionally, the Gutenberg–Richter relationship was applied to calculate the a- and b-values specific to Iraq. The findings show that the Zagros Fold-Thrust Belt has a seismogenic layer (source) that ranges from 2 to 33 km deep and experiences high seismic activity. In contrast, the Mesopotamian Foredeep has a seismogenic layer ranging from 1 to 25 km deep and has lower seismic activity. The greatest seismic activity is concentrated around the Mandili-Badra-Teeb fault, which has experienced significant ruptures over time. The Outer Arabian Platform is identified as the main area of seismic activity, while additional activity occurs on the Inner Arabian Platform. Three major tectonic boundaries define the distribution of earthquakes in the northeastern Arabian Plate. These boundaries are defined by the Main Zagros Reverse Fault, the Zagros Foredeep Fault and the Anah Graben and Abu Jir-Euphrates Fault Zone. These boundaries highlight variations in seismicity levels and the spatial distribution of deformation in the region. The updated earthquake catalogue presented in this study is expected to play a vital role in regional seismicity assessments and seismic hazard analyses for Iraq and its surrounding areas.

58 GEOSCIENCES↗

Chemical Thermodynamics and the Mathematical Integration of Reaction Kinetics

Key advances in the development of numerical methods for non-reacting compressible flows have been enabled by translating physical requirements into concrete numerical guidelines, such as the satisfaction of entropy inequalities for shock-capturing techniques [Lax, Contributions to Nonlinear Functional Analysis (1971) 603-634]. In the present work, we present nonlinear numerical analysis tools that draw from Chemical Thermodynamics , the branch of Nonequilibrium Thermodynamics that deals with chemical reactions. Through Gibbs formalism, chemical thermodynamics provides a well-known theoretical expression for the chemical equilibrium constant of a reaction in terms of reduced chemical potentials. A less-known, yet extremely valuable result, due to [Krambeck, Arch. Ration. Mech. Anal. , 38 (1970) 317], states that when this expression is implemented, mass-action kinetic models are consistent with the dynamical prescriptions of the 2nd law of thermodynamics. For fixed-temperature ordinary differential equations modeling constant-volume reacting gas mixtures, this leads to a decreasing Helmholtz free energy. If the temperature is allowed to vary in accordance with conservation of energy (1st law), this leads to the statement of increasing entropy. These nonlinear prescriptions can, and should be, used to further develop temporal integration techniques for reaction kinetics. We demonstrate that Krambeck's result holds even when the equilibrium constants are approximated from data. We prove this result by constructing the implicit free energy and the implicit entropy inherent to a given approximation. This is first done for a 5-species, 17-reaction model problem for air. With this structure established, elements of discrete entropy-stability theory [Tadmor, Acta Numer. , 12 (2003) 451] are leveraged to examine the consistency of time-integration schemes with these prescriptions. Using chemical potentials, one can compute the respective contributions of the kinetics model and of the temporal scheme to free energy/entropy variations. We introduce a nonlinear-stable version of the Discontinuous-Galerkin (DG) scheme in time which shows robustness improvements over the standard linearly-stable version. Most notably, the maximum timestep that can be resolved with the nonlinearly-stable variant tends to grow with polynomial order, in contrast to the linearly-stable variant. We generalize our constructions to arbitrary systems of reversible chemical reactions, ultimately showing that the compressible reacting Euler system admits the opposite of the implicitly constructed thermodynamic entropy as a mathematical entropy . This lays important theoretical foundations towards robust scheme development [Harten, J. Comput. Phys. 49 (1983) 151-164].

STMD↗

Status of TRMM Monthly Estimates of Tropical Precipitation

Nearly three years of Tropical Rainfall Measuring Mission Satellite (TRMM Satellite) monthly estimates of tropical surface rainfall are analyzed to document and understand the differences among the TRMM-based estimates and how these differences relate to the pre-TRMM estimates and current operational analyses. Variation among the TRMM estimates is shown to be considerably smaller than among a pre-TRMM collection of passive microwave-based products. Use of both passive and active microwave techniques in TRMM should lead to increased confidence in converged estimates. Current TRMM estimates are shown to have a range of about 20% for the tropical ocean as a whole, with variations in heavily raining ocean areas of the ITCZ and SPCZ having differences over 30%. In mid-latitude ocean areas the differences are smaller. Over land there is a distinct difference between the tropics and mid-latitude with a reversal between some of the products as to which tends to be relatively high or low. Comparisons of TRMM estimates with ocean atoll and land gauge information point to products that might have significant regional biases. The radar-based product is significantly low biased compared with atoll raingauge data, while the passive microwave product is significantly high compared to raingauge data in the deep tropics. The evolution of rainfall patterns during the recent change from intense El Nino to a long period of La Nina and then a gradual return to near neutral conditions is described using TRMM. The time history of integrated rainfall over the tropical oceans (and land) during this period differs among the passive and active microwave TRMM estimates.

Adler, Robert F.↗

Robust analysis of space-, time-, and energy-resolved soft x-ray measurements of magnetically confined fusion plasmas (invited)

A novel compact multi-energy soft x-ray (ME-SXR) diagnostic based on the PILATUS3 100K x-ray detector has been developed in collaboration between the Princeton Plasma Physics Laboratory and the University of Wisconsin-Madison and tested on the Madison Symmetric Torus (MST) reversed-field pinch. This solid-state photon-counting detector consists of a two-dimensional array of ~100 000 pixels for which the lower photon absorption cutoff energy can be independently set, allowing it to be configured for a unique combination of simultaneous spatial, spectral, and temporal resolution of ~1 cm, 100 eV, and 500 Hz, respectively. The diagnostic is highly versatile and can be readily adapted to diverse plasma operating conditions and scientific needs without any required downtime. New results from improved-confinement and quasi-single helicity plasmas in the MST demonstrate how the detector can be applied to study multiple aspects of the evolution of magnetically confined fusion-grade plasmas. These include observing the evolution of thermal emissivity, characterizing the energy of mid-Z excitation lines, extracting the T e profile, and observing the evolution of non-thermal populations. A technique for integrating the ME-SXR diagnostic into an integrated data analysis framework based on Bayesian inference is also presented. As a result, this allows ME-SXR measurements to be combined with data for complementary diagnostics in order to simultaneously infer Te and nZ from all available information.

47 OTHER INSTRUMENTATION↗

Aircraft automatic-flight-control system with inversion of the model in the feed-forward path using a Newton-Raphson technique for the inversion

A new automatic flight control system concept suitable for aircraft with highly nonlinear aerodynamic and propulsion characteristics and which must operate over a wide flight envelope was investigated. This exact model follower inverts a complete nonlinear model of the aircraft as part of the feed-forward path. The inversion is accomplished by a Newton-Raphson trim of the model at each digital computer cycle time of 0.05 seconds. The combination of the inverse model and the actual aircraft in the feed-forward path alloys the translational and rotational regulators in the feedback path to be easily designed by linear methods. An explanation of the model inversion procedure is presented. An extensive set of simulation data for essentially the full flight envelope for a vertical attitude takeoff and landing aircraft (VATOL) is presented. These data demonstrate the successful, smooth, and precise control that can be achieved with this concept. The trajectory includes conventional flight from 200 to 900 ft/sec with path accelerations and decelerations, altitude changes of over 6000 ft and 2g and 3g turns. Vertical attitude maneuvering as a tail sitter along all axes is demonstrated. A transition trajectory from 200 ft/sec in conventional flight to stationary hover in the vertical attitude includes satisfactory operation through lift-cure slope reversal as attitude goes from horizontal to vertical at constant altitude. A vertical attitude takeoff from stationary hover to conventional flight is also demonstrated.

Smith, G. A.↗

Variable Step Integration Coupled with the Method of Characteristics Solution for Water-Hammer Analysis, A Case Study

One-dimensional water-hammer modeling involves the solution of two coupled non-linear hyperbolic partial differential equations (PDEs). These equations result from applying the principles of conservation of mass and momentum to flow through a pipe, and usually the assumption that the speed at which pressure waves propagate through the pipe is constant. In order to solve these equations for the interested quantities (i.e. pressures and flow rates), they must first be converted to a system of ordinary differential equations (ODEs) by either approximating the spatial derivative terms with numerical techniques or using the Method of Characteristics (MOC). The MOC approach is ideal in that no numerical approximation errors are introduced in converting the original system of PDEs into an equivalent system of ODEs. Unfortunately this resulting system of ODEs is bound by a time step constraint so that when integrating the equations the solution can only be obtained at fixed time intervals. If the fluid system to be modeled also contains dynamic components (i.e. components that are best modeled by a system of ODEs), it may be necessary to take extremely small time steps during certain points of the model simulation in order to achieve stability and/or accuracy in the solution. Coupled together, the fixed time step constraint invoked by the MOC, and the occasional need for extremely small time steps in order to obtain stability and/or accuracy, can greatly increase simulation run times. As one solution to this problem, a method for combining variable step integration (VSI) algorithms with the MOC was developed for modeling water-hammer in systems with highly dynamic components. A case study is presented in which reverse flow through a dual-flapper check valve introduces a water-hammer event. The predicted pressure responses upstream of the check-valve are compared with test data.

Turpin, Jason B.↗

Growth and differentiation of human lens epithelial cells in vitro on matrix

PURPOSE: To characterize the growth and maturation of nonimmortalized human lens epithelial (HLE) cells grown in vitro. METHODS: HLE cells, established from 18-week prenatal lenses, were maintained on bovine corneal endothelial (BCE) extracellular matrix (ECM) in medium supplemented with basic fibroblast growth factor (FGF-2). The identity, growth, and differentiation of the cultures were characterized by karyotyping, cell morphology, and growth kinetics studies, reverse transcription-polymerase chain reaction (RT-PCR), immunofluorescence, and Western blot analysis. RESULTS: HLE cells had a male, human diploid (2N = 46) karyotype. The population-doubling time of exponentially growing cells was 24 hours. After 15 days in culture, cell morphology changed, and lentoid formation was evident. Reverse transcription-polymerase chain reaction (RT-PCR) indicated expression of alphaA- and betaB2-crystallin, fibroblast growth factor receptor 1 (FGFR1), and major intrinsic protein (MIP26) in exponential growth. Western analyses of protein extracts show positive expression of three immunologically distinct classes of crystallin proteins (alphaA-, alphaB-, and betaB2-crystallin) with time in culture. By Western blot analysis, expression of p57(KIP2), a known marker of terminally differentiated fiber cells, was detectable in exponential cultures, and levels increased after confluence. MIP26 and gamma-crystallin protein expression was detected in confluent cultures, by using immunofluorescence, but not in exponentially growing cells. CONCLUSIONS: HLE cells can be maintained for up to 4 months on ECM derived from BCE cells in medium containing FGF-2. With time in culture, the cells demonstrate morphologic characteristics of, and express protein markers for, lens fiber cell differentiation. This in vitro model will be useful for investigations of radiation-induced cataractogenesis and other studies of lens toxicity.

Non-NASA Center↗

Quantum simulation of boson-related Hamiltonians: techniques, effective Hamiltonian construction, and error analysis

Elementary quantum mechanics proposes that a closed physical system consistently evolves in a reversible manner. However, control and readout necessitate the coupling of the quantum system to the external environment, subjecting it to relaxation and decoherence. Consequently, system-environment interactions are indispensable for simulating physically significant theories. A broad spectrum of physical systems in condensed-matter and high-energy physics, vibrational spectroscopy, and circuit and cavity QED necessitates the incorporation of bosonic degrees of freedom, such as phonons, photons, and gluons, into optimized fermion algorithms for near-future quantum simulations. In particular, when a quantum system is surrounded by an external environment, its basic physics can usually be simplified to a spin or fermionic system interacting with bosonic modes. Nevertheless, troublesome factors such as the magnitude of the bosonic degrees of freedom typically complicate the direct quantum simulation of these interacting models, necessitating the consideration of a comprehensive plan. This strategy should specifically include a suitable fermion/boson-to-qubit mapping scheme to encode sufficiently large yet manageable bosonic modes, and a method for truncating and/or downfolding the Hamiltonian to the defined subspace for performing an approximate but highly accurate simulation, guided by rigorous error analysis. In this pedagogical tutorial review, we aim to provide such an exhaustive strategy, focusing on encoding and simulating certain bosonic-related model Hamiltonians, inclusive of their static properties and time evolutions. Specifically, we emphasize two aspects: (1) the discussion of recently developed quantum algorithms for these interacting models and the construction of effective Hamiltonians, and (2) a detailed analysis regarding a tightened error bound for truncating the bosonic modes for a class of fermion-boson interacting Hamiltonians.

bosonic Hamiltonian↗

COVID-19 Biomarkers and Advanced Sensing Technologies for Point-of-Care (POC) Diagnosis

COVID-19, also known as SARS-CoV-2 is a novel, respiratory virus currently plaguing humanity. Genetically, at its core, it is a single-strand positive-sense RNA virus. It is a beta-type Coronavirus and is distinct in its structure and binding mechanism compared to other types of coronaviruses. Testing for the virus remains a challenge due to the small market available for at-home detection. Currently, there are three main types of tests for biomarker detection: viral, antigen and antibody. Reverse Transcription-Polymerase Chain Reaction (RT-PCR) remains the gold standard for viral testing. However, the lack of quantitative detection and turnaround time for results are drawbacks. This manuscript focuses on recent advances in COVID-19 detection that have lower limits of detection and faster response times than RT-PCR testing. The advancements in sensing platforms have amplified the detection levels and provided real-time results for SARS-CoV-2 spike protein detection with limits as low as 1 fg/mL in the Graphene Field Effect Transistor (FET) sensor. Additionally, using multiple biomarkers, detection levels can achieve a specificity and sensitivity level comparable to that of PCR testing. Proper biomarker selection coupled with nano sensing detection platforms are key in the widespread use of Point of Care (POC) diagnosis in COVID-19 detection.

60 APPLIED LIFE SCIENCES↗

Interdigitated electrode geometry variation and external quantum efficiency of GaN/AlGaN-based metal-semiconductor-metal UV photodetectors

Aluminum gallium-nitride (Al x Ga 1–x N)-based metal–semiconductor–metal (MSM) ultraviolet photodetectors photodetectors (PD’s) have been successfully designed and fabricated using conventional photolithography techniques and tested experimentally to study their spectral sensitivity across different Al content, x, with x varying from 0 to 0.3. (Al)GaN-based UV PD’s have wide and tunable direct band gaps. The ability to easily select the photodetected wavelength by simply varying the aluminum content of GaN thin film (Al x Ga 1–x N) is a significant advantage of these group III–V compounds. Typically, MSM PD’s grown on (Al)GaN thin films result in ultrafast photodetection because of their highly mobile carriers. These devices are limited by the carrier transit time due to the negligible capacitance presented by the interdigitated fingers. Various electrode geometries were fabricated to investigate the influence of metal contact shapes on the devices’ performance indices with emphasis on the response speed and bias-voltage–independent efficiency. Here, coupled with the independently measured Hall mobility and electric field, we computed the carrier transit time of the devices to be as short as 1.31 ps and the bias-voltage–independent external quantum efficiencies were as high as 70% at 60 V for n-doped and intrinsic devices when operated in the reverse bias regime. Here, (Al x )Ga 1–x N photodetectors were designed to explore spectral sensitivity by altering x from 0 to 0.3.

42 ENGINEERING↗

Hubble Space Telescope Fine Guidance Sensor Post-Flight Bearing Inspection

Aerospace mechanism engineering success stories often, if not always, consist of overcoming developmental, test and flight anomalies. Many times it is these anomalies that stimulate technology growth and more reliable future systems. However, one must learn from these to achieve an ultimately successful mission. It is not often that a spacecraft engineer is able to inspect hardware that has flown in orbit for several years. However, in February 1997, the Fine Guidance Sensor-I (FGS-1) was removed from the Hubble Space Telescope (HST) and returned to NASA Goddard Space Flight Center (GSFC) during the second Servicing Mission (SM2). At the time of removal, FGS-1 had nearly 7 years of service and the bearings in the Star Selector Servos (SSS) had accumulated approximately 25 million Coarse Track (CT) cycles. The main reason for its replacement was due to a bearing torque anomaly leading to stalling of the B Star Selector Servo (SSS-B) when reversing direction during a vehicle offset maneuver, referred to herein as a Reversal Bump (RB). The returned HST FGS SSS bearings were disassembled for post-service condition assessment to better understand the actual cause of the torque spikes, identify potential process/design improvements, and provide information for remedial on-orbit operation modifications. The methods and technology utilized for this inspection are not unique to this system and can be adapted to most investigation ai varying stages of the mechanism life from development, through testing, io post night evaluation. The systematic methods used for the HST Fine Guidance Sensor (FGS) SSS and specific findings are the subjects presented in this paper. The lessons learned include the importance of cleanliness and handling for precision instrument bearings and the potential effects from contamination. The paper describes in detail, the analytical techniques used for the SSS and their importance in this investigation. Inspection analytical data and photographs are included throughout the paper.

Pellicciotti, Joseph↗

Hubble Space Telescope Fine Guidance Sensor Post-Flight Bearing Inspection

Aerospace mechanism engineering success stories often, if not always, consist of overcoming developmental, test and flight anomalies. Many times it is these anomalies that stimulate technology growth and more reliable future systems. However, one must learn from these to achieve an ultimately successful mission. It is not often that a spacecraft engineer is able to inspect hardware that has flown in orbit for several years. However, in February 1997, the Fine Guidance Sensor-1 (FGS-1) was removed from the Hubble Space Telescope (HST) and returned to NASA Goddard Space Flight Center (GSFC) during the second Servicing Mission (SM2). At the time of removal, FGS-1 had nearly 7 years of service and the bearings in the Star Selector Servos (SSS) had accumulated approximately 25 million Coarse Track (CT) cycles. The main reason for its replacement was due to a bearing torque anomaly leading to stalling of the B Star Selector Servo (SSS-B) when reversing direction during a vehicle offset maneuver, referred to herein as a Reversal Bump (RB). The returned HST FGS SSS bearings were disassembled for post-service condition assessment to better understand the actual cause of the torque spikes, identify potential process/design improvements, and provide information for remedial on-orbit operation modifications. The methods and technology utilized for this inspection are not unique to this system and can be adapted to most investigations at varying stages of the mechanism life from development, through testing, to post flight evaluation. The systematic methods used for the HST Fine Guidance Sensor (FGS) SSS and specific findings are the subjects presented in this paper. The lessons learned include the importance of cleanliness and handling for precision instrument bearings and the potential effects from contamination. The paper describes in detail, the analytical techniques used for the SSS and their importance in this investigation. Inspection analytical data and photographs are included throughout the paper.

Pellicciotti, J.↗

Contrasting Trivalent Lanthanide and Actinide Complexation by Polyoxometalates via Solution-State NMR

Deciphering the solution chemistry and speciation of actinides is inherently difficult due to radioactivity, rarity, and cost constraints, especially for transplutonium elements. In this context, the development of new chelating platforms for actinides and associated spectroscopic techniques is particularly important. In this study, we investigate a relatively overlooked class of chelators for actinide binding, namely, polyoxometalates (POMs). We provide the first NMR measurements on americium–POM and curium–POM complexes, using one-dimensional (1D) 31 P NMR, variable-temperature NMR, and spin-lattice relaxation time (T 1 ) experiments. The proposed POM–NMR approach allows for the study of trivalent f-elements even when only microgram amounts are available and in phosphate-containing solutions where f-elements are typically insoluble. The solution-state speciation of trivalent americium, curium, plus multiple lanthanide ions (La 3+ , Nd 3+ , Sm 3+ , Eu 3+ , Yb 3+ , and Lu 3+ ), in the presence of the model POM ligand PW 11 O 39 7– was elucidated and revealed the concurrent formation of two stable complexes, [M III (PW 11 O 39 )(H 2 O) x ] 4– and [M III (PW 11 O 39 ) 2 ] 11– . Interconversion reaction constants, reaction enthalpies, and reaction entropies were derived from the NMR data. The NMR results also provide experimental evidence of the weakly paramagnetic nature of the Am 3+ and Cm 3+ ions in solution. Furthermore, the study reveals a previously unnoticed periodicity break along the f-element series with the reversal of T 1 relaxation times of the 1:1 and 1:2 complexes and the preferential formation of the long T 1 species for the early lanthanides versus the short T 1 species for the late lanthanides, americium, and curium. Furthermore, given the broad variety of POM ligands that exist, with many of them containing NMR-active nuclei, the combined POM–NMR approach reported here opens a new avenue to investigate difficult-to-study elements such as heavy actinides and other radionuclides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chain Dynamics in Magnetorheological Suspensions

Magnetorheological (MR) suspensions are composed of colloidal particles which acquire dipole moments when subjected to an external magnetic field. At sufficient field strengths and concentrations, the dipolar particles rapidly aggregate to form long chains. Subsequent lateral cross-linking of the dipolar chains is responsible for a rapid liquid-to-solid-like rheological transition. The unique, magnetically-activated rheological properties of MR suspensions make them ideal for interfacing mechanical systems to electronic controls. Additionally, the ability to experimentally probe colloidal suspensions interacting through tunable anisotropic potentials is of fundamental interest. Our current experimental work has focused on understanding the fluctuations of dipolar chains. It has been proposed by Halsey and Toor (HT) that the strong Landau-Peierls thermal fluctuations of dipolar chains could be responsible for long-range attractions between chains. Such interactions will govern the long-time relaxation of MR suspensions. We have synthesized monodisperse neutrally buoyant MR suspensions by density matching stabilized ferrofluid emulsion droplets with D2O. This allows us to probe the dynamics of the dipolar chains using light scattering without gravitational, interfacial, and polydispersity effects to resolve the short-wavelength dynamics of the dipolar chains. We used diffusing wave spectroscopy to measure these dynamics. The particle displacements at short times that show an independence to the field strength, but at long times exhibit a constrained, sub-diffusive motion that slows as the dipole strength is increased. The experiments are in good qualitative agreement with Brownian dynamics simulations of dipolar chains. Although there have been several important and detailed studies of the structure and interactions in MR suspensions, there has not been conclusive evidence that supports or contradicts the HT model prediction that long-range interactions exist between fluctuating chains of dipolar particles. Resolving this issue would contribute greatly to the understanding of these interesting and important materials. We have begun to test the predictions of the HT model by both examining the dynamics of individual chains and by measuring the forces between dipolar chains directly to accurately and quantitatively assess the interactions that they experience. To do so, we employ optical trapping techniques and video-microscopy to manipulate and observe our samples on the microscopic level. With these techniques, it is possible to observe chains that are fluctuating freely in three-dimensions, independent of interfacial effects. More importantly, we are able to controllably observe the interactions of two chains at various separations to measure the force-distance profile. The techniques also allow us to study the mechanical properties of individual chains and chain clusters. Our work to this point has focused on reversibly-formed dipolar chains due to field induced dipoles where the combination of this chaining, the dipolar forces, and the hydrodynamic interactions that dictate the rheology of the suspensions. One can envision, however, many situations where optical, electronic, or rheological behavior may be optimized with magneto-responsive anisotropic particles. Chains of polarizable particles may have the best properties as they can coil and flex in the absence of a field and stiffen and orient when a field is applied. We have recently demonstrated a synthesis of stable, permanent paramagnetic chains by both covalently and physically linking paramagnetic colloidal particles. The method employed allows us to create monodisperse chains of controlled length. We observed the stability, field-alignment, and rigidity of this new class of materials. The chains may exhibit unique rheological properties in an applied magnetic field over isotropic suspensions of paramagnetic particles. They are also useful rheological models as bead-spring systems. These chains form the basis for our current experiments with optical traps.

Gast, A. P.↗