Development and characterization of a high yield transportable pulsed neutron source with efficient and compact pulsed power system

The results of characterization experiments carried out on a newly developed dense plasma focus device based intense pulsed neutron source with efficient and compact pulsed power system are reported. Its high current sealed pseudospark switch based low inductance capacitor bank with maximum stored energy of ∼10 kJ is segregated into four modules of ∼2.5 kJ each and it cumulatively delivers peak current in the range of 400 kA–600 kA (corresponding to charging voltage range of 14 kV–18 kV) in a quarter time period of ∼2 μs. The neutron yield performance of this device has been optimized by discretely varying deuterium filling gas pressure in the range of 6 mbar–11 mbar at ∼17 kV/550 kA discharge. At ∼7 kJ/8.5 mbar operation, the average neutron yield has been measured to be in the order of ∼4 × 10{sup 9} neutrons/pulse which is the highest ever reported neutron yield from a plasma focus device with the same stored energy. The average forward to radial anisotropy in neutron yield is found to be ∼2. The entire system is contained on a moveable trolley having dimensions 1.5 m × 1 m × 0.7 m and its operation and control (up to the distance of 25 m) are facilitated through optically isolated handheld remote console. The overall compactness of this system provides minimum proximity to small as well as large samples for irradiation. The major intended application objective of this high neutron yield dense plasma focus device development is to explore the feasibility of active neutron interrogation experiments by utilization of intense pulsed neutron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neodymium glass laser with a pulse energy of 220 J and a pulse repetition rate of 0.02 Hz

A compact neodymium glass laser with a pulse energy of 220 J and a record-high pulse repetition rate of 0.02 Hz (pulse duration 30 ns) is developed. Thermally induced phase distortions are compensated using wave phase conjugation. The integral depolarisation of radiation is decreased to 0.4% by using linear compensation schemes. The second harmonic of laser radiation can be used for pumping Ti : sapphire multipetawatt complexes. (letters)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation and regulation of electromagnetic pulses induced by hybrid laser pulses interacting with solid targets

In inertial confinement fusion, electromagnetic pulses (EMPs) can be produced during high-power laser interacting with solid targets, which are intimately related to laser intensity and laser energy. In this study, EMPs generated by hybrid laser pulses coupling with targets are recorded and analyzed. The results indicate that a single picosecond laser gives birth to the most intense EMPs, but they are remarkably suppressed when a nanosecond laser-shooting target is triggered before the picosecond and femtosecond laser. One possible hypothesis is proposed based on x-rays inducing pre-ablation that generates pre-plasma at the surfaces of the picosecond target and femtosecond target, leading to a sharp drop both in the energy and number of the emitting hot electrons and protons. Here, the findings will deepen our understanding of the mechanism of EMPs' generation and will also open a new avenue to regulate EMPs by hybrid laser pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Small phase-space structures and their relevance to pulsed quantum evolution: Stepwise ionization of the excited hydrogen atom in a microwave pulse

Experiments have shown that the microwave ionization probability of a highly excited, almost monodimensional, hydrogen atom subjected to a microwave pulse sometimes grows in steps when the peak electric field of the pulse is increased. Classical pulsed simulations display the same steps, which have been traced to phase-space metamorphoses. Quantum numerical calculations again exhibit the same ionization steps. I show that the time sequence of two-level interactions, responsible for the observed steps in the quantum picture, is strictly related to the classical phase-space structures generated by the above-mentioned metamorphoses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation of circularly polarized attosecond pulses by intense ultrashort laser pulses from extended asymmetric molecular ions

We present a method for generation of single circularly polarized attosecond pulses in extended asymmetric HHe{sup 2+} molecular ions. By employing an intense ultrashort circularly polarized laser pulse with intensity 4.0x10{sup 14} W/cm{sup 2}, wavelength 400 nm, and duration 10 optical cycles, molecular high-order-harmonic generation (MHOHG) spectra with multiple plateaus exhibit characters of circular polarization. Using a classical laser-induced collision model, double collisions of continuum electrons first with neighboring ions and then second with parent ions are presented at a particular internuclear distance and confirmed from numerical solutions of a time-dependent Schroedinger equation. We analyze the MHOHG spectra with a Gabor time window and find that, due to the asymmetry of HHe{sup 2+}, a single collision trajectory of continuum electrons with ions can produce circularly polarized harmonics, leading to single circularly polarized attosecond pulses for specific internuclear distances.

74 ATOMIC AND MOLECULAR PHYSICS↗

Generation of an isolated sub-40-as pulse using two-color laser pulses: Combined chirp effects

In this paper, we theoretically discuss the combined chirp effects on the isolated attosecond generation when a model Ar is exposed to an intense 5-fs, 800-nm fundamental chirped pulse combined with a weak 10-fs, 1200-nm controlling chirped pulse. It shows that for the case of the chirp parameters {beta}{sub 1} = 6.1 (corresponding to the 800-nm field) and {beta}{sub 2} = 4.0 (corresponding to the 1200-nm field), both the harmonic cutoff energy and the supercontinuum can be remarkably extended resulting in a 663-eV bandwidth. Moreover, due to the introduction of the chirps, the short quantum path is selected to contribute to the harmonic spectrum. Finally, by superposing a properly selected harmonic spectrum in the supercontinuum region, an isolated pulse as short as 31 as (5 as) is generated without (with) phase compensation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Control of Electron Localization in Deuterium Molecular Ions using an Attosecond Pulse Train and a Many-Cycle Infrared Pulse

We demonstrate an experimental control of electron localization in deuterium molecular ions created and dissociated by the combined action of an attosecond pulse train and a many-cycle infrared (IR) pulse. The attosecond pulse train is synthesized using both even and odd high order harmonics of the driving IR frequency so that it can strobe the IR field once per IR cycle. An asymmetric ejection of the deuterium ions oscillates with the full IR period when the APT-IR time-delay is scanned. The observed control is due to the creation of a coherent superposition of 1s {sigma}{sub g} and 2p {sigma}{sub u} states via interference between one-photon and two-photon dissociation channels.

74 ATOMIC AND MOLECULAR PHYSICS↗

Status and Development of Pulsed Magnets at the NHMFL Pulsed Field Facility

The National High Magnetic Field Laboratory's Pulsed Field Facility at Los Alamos National Laboratory is one of few research centers in the world that can create and use ultrahigh pulsed magnetic field for scientific research. The facility houses several types of nondestructive pulsed magnets which can provide the peak fields ranging from 60 to 100 T for users. This study will report the status of the user magnets and recent magnet developments to improve the quality and magnetic fields of our user magnets. In particular, this paper will present a new cooling technique that significantly reduces the cooling time without affecting the mechanical performance of the magnets. A possible upgrade of our facility with a new duplex magnet that is powered by a 4-MJ capacitor bank to deliver 80 T for users will be also reported. Finally, in addition, we will discuss some valuable lessons learned from magnet failures at our facility and possible further magnet design improvements to increase the magnet longevity or peak magnetic fields.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of Ar/Kr ratio and pulse parameters in a Cr-N high power pulse magnetron sputtering process on plasma and coating properties

Krypton is sometimes used in physical vapor deposition processes due to its greater atomic mass and size compared to argon, which leads to a lower gas incorporation and may have beneficial effects on kinetics of the coating growth. In this paper, the authors investigate the plasma composition and properties of deposited high power pulse magnetron sputtering Cr-N coatings for discharges with various Ar/Kr ratios and for various pulse lengths of 40 μs, 80 μs, and 200 μs, keeping the average discharge power constant. The results show that an addition of Kr influences the discharge process by altering the ignition and peak values of the discharge current. This influences the metal ion generation and growth conditions on the substrate by reducing the nucleation site densities, leading to a predominantly columnar grow. However, the deposition rate is highest for an Ar/Kr ratio of 120/80. The integral of the metal ion and atom emission exhibits the same trend, having a maximum for Ar/Kr ratio of 120/80. By decreasing the pulse length, the deposition rate of coatings decreases, while the hardness increases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dependence of the Two-Photon Absorption Coefficient of Steel on the Pulse Duration During Its Ablation by Femto- and Picosecond Laser Pulses

The dependences of the depth of single-pulse ablation of the steel surface on the energy density of ultrashort laser pulses (0.3–12 ps) with a wavelength of 515 nm have the form different from the usual logarithmic one for linear absorption of radiation. Since the density of states of free conduction electrons in the s band is low, and the d band of strongly bound electrons with a high density of states is located around the Fermi level, these dependences have been approximated within the two-photon absorption model. The two-photon absorption coefficient increases almost linearly with the duration of laser pulses, which indicates the saturation of absorption and allows estimating the corresponding parameters of the electronic subsystem. © 2019, Pleiades Publishing, Inc.

60 APPLIED LIFE SCIENCES↗

Single pulse laser-induced breakdown spectroscopy of bulk aqueous solutions at oceanic pressures: interrelationship of gate delay and pulse energy

The ability of oceanographers to make sustained measurements of ocean processes is limited by the number of available sensors for long-term in situ analysis. In recent years, laser-induced breakdown spectroscopy (LIBS) has been identified as a viable technique to develop into an oceanic chemical sensor. We performed single pulse laser-induced breakdown spectroscopy of high pressure bulk aqueous solutions to detect three analytes (sodium, manganese, and calcium) that are of key importance in hydrothermal vent fluids, an ocean environment that would greatly benefit from the development of an oceanic LIBS sensor. The interrelationship of the key experimental parameters, pulse energy and gate delay, for a range of pressures up to 2.76x10{sup 7} Pa, is studied. A minimal effect of pressure on the peak intensity is observed. A short gate delay (less than 200 ns) must be used at all pressures. The ability to use a relatively low laser pulse energy (less than approx. 60 mJ) for detection of analytes at high pressure is also established. Na, Mn, and Ca are detectable at pressures up to 2.76x10{sup 7} Pa at 50, 500, and 50 ppm, respectively, using an Echelle spectrometer.

54 ENVIRONMENTAL SCIENCES↗

Determining the transient electric field and the effect of pulse repetition frequency on the field in a repetitive 10-ns pulsed discharge in a quiescent CH 4 -air mixture

The goal of this research is to understand the underlying physics enabled by nanosecond pulsed power in a discharge initiation and the following physicochemical processes that favor lean-fuel plasma ignition for combustion. The hypothesis of this project is that pulsed power waveforms such as the pulse repetition frequency (PRF), voltage amplitude, and dielectric surface alter the reduced electric field during the initiation of the discharge, resulting in different plasma properties, which will vary the physicochemical processes for efficient and selective radical productions. This is especially important for lean-burn combustion and reducing emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mitigation of Electromagnetic Pulse (EMP) Effects from Short-Pulse Lasers and Fusion Neutrons

Our research focused on obtaining a fundamental understanding of the source and properties of EMP at the Titan PW(petawatt)-class laser facility. The project was motivated by data loss and damage to components due to EMP, which can limit diagnostic techniques that can be used reliably at short-pulse PW-class laser facilities. Our measurements of the electromagnetic fields, using a variety of probes, provide information on the strength, time duration, and frequency dependence of the EMP. We measure electric field strengths in the 100's of kV/m range, durations up to 100 ns, and very broad frequency response extending out to 5 GHz and possibly beyond. This information is being used to design shielding to mitigate the effects of EMP on components at various laser facilities. We showed the need for well-shielded cables and oscilloscopes to obtain high quality data. Significant work was invested in data analysis techniques to process this data. This work is now being transferred to data analysis procedures for the EMP diagnostics being fielded on the National Ignition Facility (NIF). In addition to electromagnetic field measurements, we measured the spatial and energy distribution of electrons escaping from targets. This information is used as input into the 3D electromagnetic code, EMSolve, which calculates time dependent electromagnetic fields. The simulation results compare reasonably well with data for both the strength and broad frequency bandwidth of the EMP. This modeling work required significant improvements in EMSolve to model the fields in the Titan chamber generated by electrons escaping the target. During dedicated Titan shots, we studied the effects of varying laser energy, target size, and pulse duration on EMP properties. We also studied the effect of surrounding the target with a thick conducting sphere and cube as a potential mitigation approach. System generated EMP (SGEMP) in coaxial cables does not appear to be a significant at Titan. Our results are directly relevant to planned short-pulse ARC (advanced radiographic capability) operation on NIF.

36 MATERIALS SCIENCE↗

Assessment and Mitigation of Electromagnetic Pulse (EMP) Impacts at Short-pulse Laser Facilities

The National Ignition Facility (NIF) will be impacted by electromagnetic pulse (EMP) during normal long-pulse operation, but the largest impacts are expected during short-pulse operation utilizing the Advanced Radiographic Capability (ARC). Without mitigation these impacts could range from data corruption to hardware damage. We describe our EMP measurement systems on Titan and NIF and present some preliminary results and thoughts on mitigation.

36 MATERIALS SCIENCE↗

Assessment and Mitigation of Electromagnetic Pulse (EMP) Impacts at Short-pulse Laser Facilities

The National Ignition Facility (NIF) will be impacted by electromagnetic pulse (EMP) during normal long-pulse operation, but the largest impacts are expected during short-pulse operation utilizing the Advanced Radiographic Capability (ARC). Without mitigation these impacts could range from data corruption to hardware damage. We describe our EMP measurement systems on Titan and NIF and present some preliminary results and thoughts on mitigation.

36 MATERIALS SCIENCE↗

Pulse dilation gas Cherenkov detector for ultra-fast gamma reaction history at the National Ignition Facility (invited)

The Cherenkov mechanism used in Gas Cherenkov Detectors (GCDs) is exceptionally fast. However, the temporal resolution of GCDs, such as the Gamma Reaction History diagnostic at the National Ignition Facility (NIF), has been limited by the current state-of-the-art photomultiplier tube technology to ~100 ps. The soon-to-be deployed Pulse Dilation Photomultiplier Tube (PD-PMT) at NIF will allow for temporal resolution comparable to that of the gas cell or ~10 ps. Enhanced resolution will contribute to the quest for ignition in a crucial way through precision measurements of reaction history and ablator areal density (ρR) history, leading to better constrained models. Features such as onset of alpha heating, shock reverberations, and burn truncation due to dynamically evolving failure modes may become visible for the first time. Test measurements of the PD-PMT at Atomic Weapons Establishment confirmed that design goals have been met. The PD-PMT provides dilation factors of 2 to 40× in 6 increments. The GCD-3 recently deployed at the NIF has been modified for coupling to a PD-PMT and will soon be making ultrafast measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved RIXS experiment with pulse-by-pulse parallel readout data collection using X-ray free electron laser

Abstract Time-resolved resonant inelastic X-ray scattering (RIXS) is one of the developing techniques enabled by the advent of X-ray free electron laser (FEL). It is important to evaluate how the FEL jitter, which is inherent in the self-amplified spontaneous emission process, influences the RIXS measurement. Here, we use a microchannel plate (MCP) based Timepix soft X-ray detector to conduct a time-resolved RIXS measurement at the Ti L 3 -edge on a charge-density-wave material TiSe 2 . The fast parallel Timepix readout and single photon sensitivity enable pulse-by-pulse data acquisition and analysis. Due to the FEL jitter, low detection efficiency of spectrometer, and low quantum yield of RIXS process, we find that less than 2% of the X-ray FEL pulses produce signals, preventing acquiring sufficient data statistics while maintaining temporal and energy resolution in this measurement. These limitations can be mitigated by using future X-ray FELs with high repetition rates, approaching MHz such as the European XFEL in Germany and LCLS-II in the USA, as well as by utilizing advanced detectors, such as the prototype used in this study.

36 MATERIALS SCIENCE↗

Optimal generation of spatially coherent soft X-ray isolated attosecond pulses in a gas-filled waveguide using two-color synthesized laser pulses

Here, we numerically demonstrate the generation of intense, low-divergence soft X-ray isolated attosecond pulses in a gas-filled hollow waveguide using synthesized few-cycle two-color laser waveforms. The waveform is a superposition of a fundamental and its second harmonic optimized such that highest harmonic yields are emitted from each atom. We then optimize the gas pressure and the length and radius of the waveguide such that bright coherent high-order harmonics with angular divergence smaller than 1 mrad are generated, for photon energy from the extreme ultraviolet to soft X-rays. By selecting a proper spectral range enhanced isolated attosecond pulses are generated. We study how dynamic phase matching caused by the interplay among waveguide mode, neutral atomic dispersion, and plasma effect is achieved at the optimal macroscopic conditions, by performing time-frequency analysis and by analyzing the evolution of the driving laser’s electric field during the propagation. Our results, when combined with the on-going push of high-repetition-rate lasers (sub- to few MHz’s) may eventually lead to the generation of high-flux, low-divergence soft X-ray tabletop isolated attosecond pulses for applications.